5-1-1 Cabinet Disassembly
1. With a pad beneath it, stand the monitor on its
front with the screen facing downward and
the base close to you. Make sure nothing will
damage the screen.
2. Working from the back of the monitor remove
the 2 screws.
3. To uncover the 2 uppermost screws, press in
the end of each screw cover cap and pull it
away from the cabinet. Remove the Rear
cover.
4. Using pinch-nosed pliers or long-nosed pliers,
carefully disconnect the Anode Cap from the
CRT.
Caution: Do not touch the anode contact on
the CRT.
5-1-2 Removing the Video PCB
1. Complete all previous steps.
2. Remove the screw on the Main PCB which
secures the braided ground wire on the Video
Shield. Remove all other ground wires.
3. Unsolder the center tabs on the underside of
the Video PCB Shield and remove the Video
PCB Shield.
4. Using a knife, cut the silicone bond and lift off
the CRT Socket PCB.
5. Lift off the Video PCB Ass’y.
6. Disconnect connectors CN101 and CN102 on
the Video PCB.
7. Disconnect the red screen (G2) wire on the
Video PCB.
8. Hold the Video PCB while you lift the cap on
the CRT Socket. Disconnect the red Focus wire
(G3).
5-1-3 Removing the Main PCB
1. Complete all previous steps.
2. Disconnect the Degaussing Coil at CN600 on
the Main PCB.
3. Disconnect all easily accessible ground wires
from the CRT GND Assembly and Bottom
Chassis.
4. Disconnect the DY connector between the DY
and the CN300, CN301, CN401, CN402 and
CN403 connectors on the Main PCB.
5. Remove the 2 screws on the left and right
sides of the PCB Bracket.
6. Carefully lift the Main PCB Ass’y.
7. Carefully lift off the Power Shaft from the
Main PCB.
8. Disconnect the adjustment control connector
CN201 on the Main PCB.
9. Remove the 6 screws on the top side of the
Main PCB.
10. Lift the Main PCB and place it on a flat, level
surface that is protected from static electricity.
CKF5607L 5-1
5 Disassembly and Reassembly
This section of the service manual describes the disassembly and reassembly procedures for the
CKF5607L monitor.
WARNING: This monitor contains electrostatically sensitive devices. Use caution when handling
these components.
5-1 Disassembly
Cautions:1. Disconnect the monitor from the power source before disassembly.
2. Follow these directions carefully; never use metal instruments to pry apart the cabinet.

5-2-1 Replacing the CRT
1. Loop the CRT Ground Assembly around the
back of the CRT and under the 4 corner, metal
ears. Position the corner with the spring last.
2. With the Front Cover Assembly lying face
down on a protective pad, position the CRT so
that the corner metal ears fit properly in the
Front Cover Assembly.
3. Replace the 4 corner screws.
4. Replace the Degaussing Coil Assembly and
wrap the coil with the plastic coated matal ties
to hold the coil in place.
5. Replace the CRT Ground Assembly.
6. Replace the Unit Bracket Assembly.
5-2-2 Replacing the Main PCB
1. Stand the monitor on its front with the screen
facing downward.
2. Replace the Power Shaft on the Main PCB.
3. Replace the 6 screws on the top side of the
Main PCB.
4. Replace connector CN201 on the Main PCB.
5. Position the Main PCB Ass’y in the Front
Cabinet and secure it on both sides with the
screws between the Bottom Chassis and CRT
Unit Bracket.
6. Replace the DY connector at the CN300,
CN301, CN401, CN402 and CN403 connectors
on the Main PCB.
7. Replace all easily accessible ground wires on
the CRT GND Assembly and Bottom Chassis.
8. Replace the Degaussing Coil at CN600 on the
Main PCB.
9. Replace the Anode Cap.
5-2-3 Replacing the Video PCB
1. Replacing the Focus (G3) wire on the CRT
Socket and the screen (G2) wire on the Video
PCB.
2. Replace connectors CN101 and CN102 on the
Video PCB.
3. Reconnector the CRT Socket on the Video
PCB.
4. Solder the center tab on the underside of the
Video PCB Shield and replace the Video PCB
Shield.
5. Replace the screw on the Main PCB which
secures the braided ground wire from the
Video Shield and replace all other ground
wires.
5-2-4 Cabinet Reassembly
1. Complete all previous steps.
2. Position the Rear Cover making sure that the
tabs along the front edge are properly
snapped in place. Replace the 4 screws.
3. Set the monitor on its Base and make sure that
the CRT faceplate was not scratched or
otherwise damaged.
5 Disassembly and Reassembly
5-2 CKF5607L
5-2 Reassembly
With the CRT facing downward on a protective pad, use the steps that follow to reassemble the monitor.