Samsung AQV09J user manual

ENGLISH
INSTALLATION MANUAL
AQV09J AQV12J Series AQV18J Series AQV24J Series
ESPAÑOLFRANÇAIS
DB98-27556A(1)
SE F
Split - type Air Conditioner
(Cooling and Heating)
E-2
Contents
PREPARING FOR INSTALLATION
 
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
 
Choosing the Installation Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
 
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
INSTALLING THE AIR CONDITIONER
 
Fixing the Installation Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
 
Purging the Indoor Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
 
Installing and Connecting the Assembly Pipe of the Indoor Unit . . . . 8
 
Cutting or Extending the Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
 
Installing and Connecting the Drain Hose of the Indoor Unit . . . . . . 10
 
Changing Direction of the Drain Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
 
Installing and Connecting the Drain Hose of the Outdoor Unit . . . . . 11
 
Connecting the Assembly Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
COMPLETING THE INSTALLATION
 
Purging the Connected Pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
 
Performing the Gas Leak Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
 
Fixing the Indoor Unit in Place . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
 
Fixing the Outdoor Unit in Place . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
 
Final Check and Trial Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
 
Providing Information for User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
E-3
ENGLISH
Safety Precautions
Keep this installation manual together with the user’s manual in a handy place so that you can find it whenever you need to see it after reading this manual thoroughly.
Make sure to read the following safety precautions carefully before installation. Make sure to observe the cautions specified in this manual. Conduct a test run of the unit after installation and then explain all system functions to the owner. The indications and meanings are as shown below.
WARNING
Installation must be carried out by a qualified installer.
Installers are required to read the general information carefully for safety.
Do not put the unit near dangerous substances to prevent fire, explosion or injury and do not expose the unit to direct sunlight.
Do not install the unit by yourself (owners). Incorrect installation of the unit could cause injury due to fire, electric shock and water leakage or from the unit falling. Consult a dealer or a qualified installer.
Install the unit in a place where it is strong enough to hold the product weight. When installed in place where it is not strong enough to withhold the product weight, the unit could fall and cause injury.
This indicates the possibility of serious injury or death.
Use the specified wires to connect the indoor and outdoor units securely and attach the wires firmly to the terminal block connecting sections so that the pressure is not applied to the sections. Inappropriate connection and fixing could cause fire.
Avoid the use of an extension cord and do not share the power outlet with other appliances. Incomplete connection, defective insulation or exceeding the permissible current may cause electric shock or fire.
Make sure that the refrigerant gas does not leak after completing the installation.
If the refrigerant gas of the indoor unit leaks and comes into contact with the fan heater, space heater or stove, harmful substances will be generated.
Perform the installation securely referring to the installation manual. Incomplete installation could cause personal injury due to fire, electric shock and water leakage or from the unit falling.
Attach the electrical cover to the indoor and outdoor unit securely. If not, it could result in fire or electric shock due to dust or water.
Make sure to use the part provided or specified parts for the installation work. The use of defective parts could cause an injury or leakage of water due to a fire, an electric shock, the unit falling, etc.
Make sure to turn off the main power when setting up the indoor unit electrical circuit or power cords. There is a risk of electric shock.
E-4
WARNING
This indicates the possibility of serious injury or death.
The unit should be installed in accordance with the National Electrical regulations.
Ensure that the national safety code requirements have been followed for the main supply circuit. Ensure that a properly sized and connected ground wire is in place.
CAUTION
Check the unit for damage
This indicates the possibility of serious injury or damage to environments when
that may have taken place during transportation and do not install or use damaged equipment.
All of the manufacturing and packaging material used for your new appliance are compatible with the environment and can be recycled.
Dispose of the packaging material in accordance with the local requirements.
This product is an air conditioning system and contains a coolant that must be recovered and disposed of in an appropriate way by qualified personnel. At the end of the life cycle, take it to a proper recycling or disposal center or return it to the dealer so that it can be disposed correctly.
Check if the voltage and the frequency of the main power supply are those required for the unit to be installed and check the connection.
Make sure that properly sized disconnecting and safety switches are installed.
operated incorrectly
Grounding the unit. Do not connect the ground to a gas pipe, water pipe, lightning rod or telephone grounding. Defective grounding could cause electric shock.
Do not install the unit in a place where it is exposed to inflammable gas leakage. There is a risk of explosion.
Install a ground leakage breaker depending on the installation place (where it is humid). If not, it may cause electric shock.
Perform the drainage/piping work securely according to the installation manual. If not, water could drop from the unit and household goods could get wet and damaged.
Do not attempt to repair, move, modify or reinstall the unit on your own. Make sure that these installations are carried out by qualified personnel to avoid electric shock or fire.
Use the unit on a single outlet circuit. Do not share the power outlet with other appliances. Obtain the consent by a qualified installer before connecting the unit to the power supply system.
.
Fasten a flare nut with a torque wrench as specified in this installation manual.
When fastened too tight, a flare nut may break after a long period of time and cause refrigerant leakage.
To prevent injury when accidentally touching the indoor unit fan, install the indoor unit on a place higher than 8.2ft (2.5m).
The air conditioner must be installed according to the national electrical regulations.
The maximum input power & current is measured according to the IEC standard and the input power & current is measured according to the ISO standard.
E-5
ENGLISH
Choosing the Installation Location
Indoor Unit Outdoor Unit
Where airflow is not blocked Where cool air can be distributed throughout the room Install the refrigerant piping length and the height
difference of both indoor and outdoor units as indicated in the installation diagram
Wall that prevents vibration and is strong enough to hold the
product weight
Out of the direct sunlight 3.3ft (1m) or more away from the TV or radio
(to prevent the screen from being distorted or noise from being generated)
As far away as possible from fluorescent and incandescent lights
(so that the remote control can be operated well)
A place where the air filter can be replaced easily
CAUTION
 Avoid the following places to prevent malfunction of the unit
- Where there is machine oil - Salty environment such as the seaside areas
- Where sulfide gas exists - Other special atmosphere areas
Where it is not exposed to strong wind Well ventilated and dustless places Out of the direct sunlight and rain Where neighbors are not annoyed by operation sound or hot air Solid wall or support that prevents vibration and is strong
enough to hold the product weight
Where there is no risk of flammable gas leakage When installing the unit at a high place be sure to fix the unit
legs
9.9ft (3m) or more away from the TV or radio (to prevent the
screen from being distorted or noise from being generated)
Install the unit horizontally
PREPARING FOR INSTALLATION
Observe the clearances and maximum lengths as seen in the picture below when installing the air conditioner.
11.8 inch (300mm) or more
Wrap the refrigerant pipes and the drain hose with the absorbent pad and vinyl tape. Refer to page 15 for further details.
11.8 inch (300mm) minimum
23.6 inch (600mm) minimum
4.9 inch (125mm) or more
23.6 inch (600mm) minimum
“A” maximum total pipe length
11.8 inch (300mm) minimum
You can select the direction of draining. (left or right)
4.9 inch (125mm) or more
“B” maximum total pipe Height
Model “A” “B”
AQV09J
49.2ft(15m) 26.2ft(8m)
 
98.4ft(30m) 49.2ft(15m)
The appearance of the unit may be different from the diagram depending on the model.
AQV12J AQV18J AQV24J
E-6
PREPARING FOR INSTALLATION
Accessories
The following accessories are supplied with the air conditioner:
The number of each accessory is indicated in parentheses.
Accessories in the Indoor Unit Case
Installation Plate (1) Remote Control (1)
Batteries for
Remote Control (2)
User’s Manual (1) Installation Manual (1)
Service Manual (1)
Accessories in the Outdoor Unit Case
Drain Plug (1) Rubber Leg (4)
The flare nuts are attached to the end of each pipe of an evaporator or a service port.
Use the nuts when connecting the pipes.