3 Disassembly and Reassembly
This section of the service manual describes the disassembly and reassembly procedures for the
LE17IS/LE19IS/LE19IT TFT-LCD monitors.
WARNING: This monitor contains electrostatically sensitive devices. Use caution when handling
these components.
3-1 Disassembly
Cautions:1. Disconnect the monitor from the power source before disassembly.
2. Follow these directions carefully; never use any metal instrument except provided jig to
separate the cabinet.
3. R/Cover opening jig : BH81-00001A
1. Release the snaps on the rear stand and pull
the stand backwards from the monitor and
remove 2 screws from the rear top shield.
2. Insert the opening jig into the grooves at each
side and press unill it cilcks and lift up the
rear cover.
3. Remove 2 screws from the shield and lift up
the shield.
4. Disconnect 2 ground from the shield video
and release the 1 screw to remove the CDT
from the CDT socketboard.
5. High voltage may be present.
Caution : Remove the high voltage cap
from the CDT.
LE17IS/LE19IS/LE19IT 3-1
3 Disassembly and Reassembly
6. Disconnect DY cable, D-COIL cable from the
CDT socket. Using the jig, release the snaps
connecting the front cover and the PCB. Lift
up the bottom to separate the two shields.
7. Disconnect function wire connecter from the
MAIN board. Remove 4 screws from the front
cover.
8. Remove CDT from the front cover.
3-2 Reassembly
Reassembly procedures are in the reverse order of disassembly procedures.
3-2 LE17IS/LE19IS/LE19IT