PRO
EXPANDER/GATE
COMPRESSOR / LIMITER
GAIN REDUCTION dB INPUT / OUTPUT LEVEL dB
30 24 2127 18 15 9 612 4 2 1 -30 -18 -12-24 -6 -3 +3 +60 +9 +12 +18
DE-ESSER LEVEL dB
-3 -60 -9 -12
LIMIT
CH 1
RELEASE AUTO I/O METER IN/OUT
dB
OFF +10
050
20
TRIGGER
GATE
10
-30
+20-40
+10
-10
THRESHOLD
dB
ENHANCER
62
1
RATIO
dB
4:1
KEY
ATTACK
mSec
.3
300
20015
50
.05 5
3.15
1
RELEASE
Sec
-10
+20-20
+10
0
OUTPUT
dB
0 10
73
LEVEL
dB
5
0 OFF
16
+5
LIMITER
dB
+12
IN/OUT 1
STEREO LIN
K
IN/OUT
2
EXPANDER/GATE
COMPRESSOR / LIMITER
GAIN REDUCTION dB INPUT / OUTPUT LEVEL dB
30 24 2127 18 15 9 612 4 2 1 -30
-18 -12-24 -6 -3 +3 +60 +9 +12 +18
DE-ESSER LEVEL dB
-3 -60 -9 -12
LIMIT
CH 2
RELEASE AUTO I/O METER IN/OUT
dB
OFF
+10
050
20
TRIGGER
GATE
10
-30
+20-40
+10
-10
THRESHOLD
dB
ENHANCER
62
1
RATIO
dB
4:
1
KEY
ATTACK
mSec
.3 300
20
015
50
.05 5
3.15
1
RELEASE
Sec
-10
+20-20
+10
0
OUTPUT
dB
0 10
73
LEVEL
dB
5
0 OFF
16
+5
LIMITER
dB
+12
POWER
STEREO
COMPRESSOR
LIMITER
DE-ESSER
DE-ESSER
BALANCED
OUTPU
T
BALANCE
D
INPU
T
INPUT OUTPU
T
KE
Y
CHANNEL 2
LEVEL
+4
-10
BALANCED
OUTPUT
BALANCED
INPU
T
INPUT OUTPUT
KEY
CHANNEL 1
LEVEL
+4
-10
STEREO
COMPRESSOR
LIMITER
PROCESSORS
TYPE:
SIGNAL
PROCESSO RS
PRODU CT DESCR IPTI ON
STEREO COMPRESSOR/LIMITER
S•COM PLUS
SERIE S
S•CLASS SIGNAL PROCESSING
PRODUCT SPECIFICATION SHEET
GENERAL DESCRIPTION
The Samson S•Com plus is a one rack space, dual
channel dynamics processor optimized for recording,
live sound reinforcement systems, DJ set-ups and
commercial installations. The S•Com plus is a complete
dynamics processing solution offering two channels
of full function Compressor, Expander/Gate, Limiter
and De-Esser. S•Com plus’ convenient meters provide
instant status of important gain management settings.
FEATURES
> Full featured, dual channel dynamics processor
including Compressor/Limiter, Expander/Gate, DeEsser and Peak Limiter.
> SKD (Smart Knee Detector) switches from soft to
hard knee based on the level of input signal.
> AEG (Automatic Envelope Generator) mode constantly
adjusts the Compressor’s Attack and Release times
based on input signal. Manual adjustment of Attack
and Release time is also facilitated.
> 12 Segment LED Input/Output Meter, plus 12
Segment LED Gain Reduction Meter.
> External Keying with Key Switch available on front panel.
> Adjustable De-Esser with independent LED meter for
reducing sibilance from recorded tracks.
> Expander/Gate with variable Trigger control and
switchable Fast and Slow Release time.
CATEGO RY
> Gate function can be switched from hard off to light
Downward Expander.
> Gate Open and Closed LED's.
> Peak Limiter with independent threshold control and Limit LED.
> Advanced circuit design, utilizing low noise operational
amplifiers and high quality VCAs.
> Stereo Link Switch.
> Servo balanced inputs and outputs on XLR and 1/4” connectors.
> Switchable +4 and –10 operating levels.
> High quality, 41 position detent pots and backlit switches.
> Three-year extended warranty.
ARCHITECT’S & ENGINEER’S SPECIFICATIONS
The S•Com plus shall be a 2 channel compressor/limiter. It
shall have XLR and 1/4 inch inputs and outputs with a +4 /
-10 operation output level switch. Each channel shall have
a 1/4 inch key input and 1/4 inch key output. A Key enable
switch will also be available on the front panel. Each channel
shall have an expander/gate with a switchable Release time,
variable Trigger control, and gate open/close indicator.
The compressor controls shall be Threshold, Ratio, Attack,
Release, and Output level. An Auto switch will be available
for automatic automatic attack and release time settings on
the
compressor. An independant limiter circuit and variable
continues»
FRONT PA NEL
BACK PAN EL
©2006 Samson v1.0 5/06
430mm
430mm
44mm
482.6mm
188.1mm
TOP
FRON
T
PRODUCT SPECIFICATION SHEET
SERI ES DES CRIPT ION CATE GORY
S•CLASS MULTI-ZONE STEREO MIXER SIGNAL PROCESSING
S•COM PLUS SPECIFICATIONS
S•COM PLUS
System Specifications
Frequency Response ........... <10Hz to 20kHz +0 / -0.1 dB
effect out, -0.4 @ 100kHz,
<10Hz to 20kHz +0 / -0.1 dB
effect in, -3dB @ >100kHz
Dynamic range .................... 116 dB, un-weighted, 22 Hz
to 22 kHz
THD .................................. 0.008 % typ. @ +4 dBu, 1 kHz
Effect out, 0.016% effect in
Crosstalk ............................ >100dB, 22 Hz to 22 kHz
Operating Level .................. Selectable +4dBu / -10 dBV
Max. Input Level ................. +21dBu, balanced
CMRR ................................ Min. 40dB, >50dB @ 1kHz
Max. Output Level ............... +21dBu, balanced
Signal Input
Connectors ......................... XLR and 1/4" TRS jack
Impedance ......................... >20K Ohms balanced or
>10K unbalanced
Signal Output
Connectors ......................... XLR and 1/4" TRS jack
Impedance ......................... 60 Ohms balanced or 30
unbalanced
Key Input
Connector .......................... 1/4" jack
Impedance ......................... 10 k Ohm
Max. Input Level ................. +21 dBu
Key Output
Connector .......................... 1/4" jack
Impedance ......................... 47 Ohms
Max. Output Level ............... +21 dBu
Expander/Gate
Trigger range ...................... Variable (Off to +10 dB)
Attack ................................ <1 ms per 50 dB
Release .............................. Variable (Slow:100 ms / 1dB,
Fast:100 ms / 100 dB)
Ratio .................................Expander 2:1, Gate 16:1
Compressor Section
Detector ............................. RMS
Threshold ........................... -40 dB to +20 dB
Ratio .................................Variable (1:1 to infinity : 1)
Manual Attack Time ............ Variable (0.3 ms / 20 dB to
300 ms / 20dB)
Manual Release Time .......... Variable (0.05 to 5 Sec)
Output gain ........................ Variable (-20 to +20 dB)
Peak Limiter Section
Threshold ........................... Variable 0dB to Off
Ratio .................................Preset
Limiter ............................... Ceiling type
Attack ................................ <5 ms
Release .............................. Typ. 20dB/s
De-Esser
Level range ........................ variable (0 to 10dB)
Maximum ........................... 12dB Gain Reduction mid /
Function Switches
Gate ..................................Gate or Expander
Release .............................. Fast/slow
Enhancer ...........................In/Out
In/Out (1,2) ........................ Bypass
Key .................................... Switches the detector section
Auto .................................. Sets automatic attack and
I/O Meter ........................... Switches the Input/Output meter
In/Out ................................ De-Esser
Stereo Link ......................... Links both channels for
Level (Rear Panel) ................. Changes the internal reference
Meters & LED's
Gain Reduction ................... 12 segment LED display: 30 /
Input/Output level ............... 12 segment LED display: -30 /
Expander/Gate Threshold ..... 2 LED'S Gate open, Gate closed
Peak Limiter Threshold ........ 1 LED for Indication of
Function switch .................. LED indicator in each (except
Power Supply
Mains Voltages USA/Canada ... 105 - 125 VAC ~, 60 Hz
Mains Voltages Europe ........ 215 - 254 VAC~,50 / 60Hz
Power Consumption ............ 10 Watts
Power inlet ......................... Standard IEC receptacle/with fuse
Physical
Dimensions ........................ 1 3/4 (44.5 mm) x 19
Net Weight ......................... 5 lbs., (2.3 kg)
Shipping Weight ................. 7.5 lbs., (3.4 kg)
high band
to external key input
release times - program
dependent
to read input or output level
stereo operation. Channel 1
becomes Master.
level from +4dBu to -10dBV
27 / 24 / 21 / 18 / 15 / 12 / 9 /
6 / 4 / 2 / 1dB
-24 / -18 / -12 / -6 / -3 / 0 /
+3 / +6 / +9 / +12 / +18dB
Limiter function
Level switch)
(482.6 mm) x 7 3/4 (188 mm)
ARCHITECT’S & ENGINEER’S SPECIFICATIONS (continued)
Level control shall be on the front panel. A variable de-esser
with an In and Out switch for removing sibilance shall on the
front panel. Each channel shall have a switchable enhancer to
bring back the high frequencies lost do to heavy compression.
Full LED Gain Reduction and Input/Output metering will be
on both channels with a I/O meter switch to select input or
output viewing on the meter. The unit shall have front panel
bypass switches and a Stereo Link switch. A standard IEC
power cable shall be provided to connect to AC power.