Salter Brecknell SP100 User Manual

Page 1

Digital Bench Scale

Revision 8.93
August 12, 1993
Salter Brecknell Weighing Products
1000 Armstrong Drive
Tel (800) 637-0529 Tel (507) 238-8702
Fax (507) 238-8271
E-mail: sales@salterbrecknell.com
Web: www.salterbrecknell.com
02/18/04 1
Page 2
Table of Contents
Introduction.........................................................................................1
Installation and Wiring ........................................................................ 1
Keyboard Functions............................................................................1
Configuration ...................................................................................... 2
User Menu Descriptions...................................................................... 2
Calibration .......................................................................................... 3
Specifications ..................................................................................... 4
Warranty and Service Information ...................................................... 5
02/18/04 2
Page 3
Introduction
The SP Series Digital Bench Scale is a compact, legal for trade scale with remote digital indicator. Housed in a standard black polymer case, the indicator displays its numerals on a bright VFD screen. The base unit features a removable stainless steel platform, an RS-232 serial communication port, and adjustable feet for leveling.
The SP Series uses full duplex RS-232 serial format for communication with many types of attached support equipment. The unit can trans­mit data on demand, or continuously in several
Installation and Wiring
Unless you wish to interface to a device other than a PC, no wiring is necessary. Simply con­nect the indicator to the scale platform, plug in the AC adapter, and turn the unit on. If the swivel indicator option was ordered, the stainless steel post may be mounted to the bottom of the base with the hardware provided. Alternately, it may be mounted to a table or bench. In general, please allow a 20 minute warm up period before
popular data protocols to match a wide variety of printers, remote displays, or personal computers. If you plan to use your scale with equipment other than a PC, you may have to alter the serial communication parameters which are embed­ded in the User Menu.
The User Menu is accessed through the front panel keys. Complete directions, including a graphical road map, are found in the Configura­tion section of the manual.
using the scale. If interfacing to a PC, simply connect the optional
null modem cable to a serial port (e.g. COM 1) on your PC. If your computer has a 25-pin serial port, a standard 9-pin to 25-pin adapter, such as the type used for a mouse, may be used and is readily available at your local computer supply retailer.
If interfacing to a serial device other than a PC, you may have to wire your own cable to communicate with that device. If so, refer to the 9­pin connector pinout shown at right.
Keyboard Functions
Pin No. Pin Name
2
Receive Data
3
Transmit Data
5
Signal Ground
9-Pin Connector Pinout
02/18/04 3
Page 4
lb kg
ZERO
NET
GROSS
Toggles between lb and kg units if this key is enabled in the User Menu.
Sets indicator to display "0" when in Gross mode, and within zero band range.
Toggles between Gross and Net weight display.
n
max=3000
CLASS
MODEL
SPD100
Zero Gr Net lb kg Motion
Tare
Zero
Net
Gross
Tare Print
TRANSTRONIC SCALE CO.
lb
kg
SP SERIES FRONT PANEL
CAPACITY : 100x0.05 lb
50x0.02 kg
TARE
PRINT
Used to zero a weight indication in Net mode.
Sends "Print" data to printer if scale is stable and not in overload. Not active when "Continuous" option is selected in User Menu.
02/18/04 4
Page 5
Configuration
1200
2400
4800
9600
All Serial Communication parameters are em­bedded in a user menu consisting of 5 separate menu selections, each with its own sub-menu of choices. If your scale is connected by RS-232 serial communication lines to other equipment, or you wish to disable the lb/kg key, you may have to modify some or all of these parame-
To place the unit in USER MENU mode:
Turn the scale off.
While holding down the lb/kg
key, turn the scale back on.
When the display shows "A1",
the unit is in USER MENU mode, and you can release the lb/kg key. Shown at right are the directional and SET key assign­ments.
MODEL
SPD100
ters. To modify these parameters, you must first enter the USER MENU mode. Once there, four of the front panel keys become directional navi­gators to move around in the menus, and one key is used to save or SET the selections. Com­plete directions are found below.
n
max=3000
CLASS
Zero Gr Net lb kg MotionTare
SET
CAPACITY : 100x0.05 lb
50x0.02 kg
TRANSTRONIC SCALE CO.
USER MENU CHART
A2 A3 A4 A5A1
Baud Rate
8 7O 7E 7 0 1 2 3 4
Data Bits,
Parity
Transmission
Mode
c d 0 1
Serial Data Format Disable Lb/kg
Key
To place the unit back into the NORMAL OPERATING mode, turn off the power to the unit. With no keys held down, turn the power back on. All front panel keys will now return to their normal mode of operation.
SETTINGS FOR USE WITH UPS ONLINE AND ONLINE OFFICE SOFTWARE
A1 = 9600 A2 = 7 o
A4 = 4 A5 = 0
A3 = don’t care
02/18/04 5
Page 6
User Menu Descriptions
√√√√
√√√√
√√√√
√√√√
NAME/CODE DESCRIPTION CODE/VALUE
A1
Baud Rate
A2
Data Bits and Parity
A3
Mode of Serial Transmission
A4
Serial Data Format
A5
Disable the LB/KG Key
Selects the baud rate for data transmission through the serial port.
Selects the number of data bits and parity of serial transmission.
"8" = 8 data bits with no parity bit and one stop bit
"7O" = 7 data bits with odd parity bit and one stop bit
"7E" = 7 data bits with even parity bit and one stop bit
"7" = 7 data bits with no parity bit and two stop bits
Selects when data will be sent out of the serial port to a printer or computer:
"C" = Continuous mode; send data continuously
"d" = Demand mode; send data when a PRINT command is issued
from the printer, computer, or indicator.
Selects the data format to be transmitted via the serial port to a printer or computer.
"0" = Consolidated Controls Format
"1" = Toledo 8213 Format "2" = NCI 3825Format
"3" = Transcell Technology Format
"4" = Fairbanks 70-2453-4 Format
Allows the LB/KG key to be disabled so that an operator cannot accidentally press the key and change the displayed units.
"0" = Disable the LB/Kg key "1" = Enable the LB/KG key
1200 2400 4800 9600
8√√√
7O 7E 7
C
d
0 1 2
3
4
0
1
F13 to the Setup Menu Chart which restores all parameters in the User (“A”) Menu and Setup (“F”) Menu to the factory default settings. PLEASE USE CAREFULLY AS YOU MAY LOOSE VITAL SETUP PARAMETERS!!!
F13
Factory Reset
This sub-menu will reset all parameters in the “F” and “A” menus to the default settings. USE WITH CAUTION!!!!!
Press the ZERO key to execute.
REV 8.93
Page 7
Calibration
All SP Series scales may be calibrated with any precision test weight from 10 lb to 100 lb. The recom-
mended test weight is about 2/3 of the full scale capacity, but in general, the larger the test weight, the more accurate the scale will be. The only restriction is that the test weight must be in pounds.
To calibrate the scale:
Turn the scale off. Locate the hidden switch on the base panel and set it at the rightmost position. Turn the unit back on. The message "C 0" appears on the display briefly, followed by a value which remains on the screen. Allow a 20 minute warm-up period for the load cell and indicator to become thermally stable.
Press ZERO to zero the value, then press the NET/GROSS key to save the zero point value.
The display will momentarily prompt "C 1" for the span calibration, followed by "0.00" with one digit flashing. Place the test weight on the platform.
Use the four directional keys to adjust the displayed value to the actual test weight value in pounds. Increase the flashing digit by pressing the lb/kg key. Decrease the flashing digit by pressing the
ZERO key. The position of the flashing digit may be changed by pressing the PRINT key or the TARE key.
After setting the exact value, press the NET/GROSS key to save the value.
If the calibration was successful, the display will show "ECAL" momentarily, then freeze. Exit the Calibration mode and enter the Normal Operating Mode by turning off the scale, positioning the calibration switch back to the leftmost position, and turning the scale back on.
If the calibration was not successful, one of the error messages below will appear. Take the indi- cated action to correct the problem, then perform a new calibration.
"Err0" - The calibration test weight or the adjusted keyed-in weight is larger than full scale. Change the calibration test weight or check the keyed-in weight.
"Err1" - The calibration test weight or the adjusted keyed-in weight is smaller than 10% of full scale. Change the calibration test weight or check the keyed-in weight.
"Err2" - Check keyed-in weight with the actual weight placed on platform.
Page 8
Specifications
CONSTRUCTION:
Indicator: Black ABS with steel
back plate. Base: Steel and ABS with stainless
steel platform.
DISPLAY:
7 Digit, 0.5", 7-Segment Vacuum Fluorescent
NIST CLASSIFICATION:
Meets H-44 Class III at 3,000 divisions
OVER CAPACITY ANNUNCIATION:
103% of Full Scale Capacity
OPERATING TEMPERATURE RANGE:
32°F to 104°F (0°C to 40°C)
OPTIONAL SWIVEL POST:
12" (30mm) Tall Stainless Steel Construction
POWER SOURCE:
AC Adapter, 12VDC, 650mA, included
WEIGHT:
Net Weight: 19.4 lb (8.8 kg) Shipping Weight: 21.6 lb (9.8 kg)
Certificate of conformance
#93-059
PHYSICAL DIMENSIONS:
n
max=3000
CLASS
Zero Gr Net lb kg Motion
Tare
lb
MODEL
Zero
kg
SPD100
6.8 in [173 mm]
Net
Gross
REMOTE INDICATOR
Tare Print
TRANSTRONIC SCALE CO.
CAPACITY : 100x0.05 lb
50x0.02 kg
1.4 in [35 mm]
3.2 in [81 mm]
Page 9
13.2in [336.00mm] 10.2in [258.00mm]
3.8in [97.50mm]
DC POWER
ON/OFF
SWITCH
JACK
CALIBRATION
SWITCH COVER
ID TAG
RS-232
PORT
INDICATOR
CONNECTOR
BASE
Loading...