RuggedCom RuggedSwitch RS900G Installation Manual

RuggedSwitch RS900G
10-Port Managed Ethernet Switch with Gigabit Uplink Ports
RuggedCom Inc. I 300 Applewood Crescent, Concord, Ontario, Canada L4K 5C7
Installation Guide
www.ruggedcom.com
Copyright
COPYRIGHT © 2010 RuggedCom Inc. ALL RIGHTS RESERVED Dissemination or reproduction of this document, or evaluation and communication of its contents, is
not authorized except where expressly permitted. Violations are liable for damages. All rights reserved, particularly for the purposes of patent application or trademark registration.
This document contains proprietary information, which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced or translated to another language without the prior written consent of RuggedCom Inc.
Disclaimer of liability
We have checked the contents of this manual against the hardware and software described. However, deviations from the description cannot be completely ruled out.
RuggedCom shall not be liable for any errors or omissions contained herein or for consequential damages in connection with the furnishing, performance, or use of this material.
The information given in this document is reviewed regularly and any necessary corrections will be included in subsequent editions. We appreciate any suggested improvements. We reserve the right to make technical improvements without notice.
Registered Trademarks
RuggedSwitch
®
and ROS® are registered trademarks of RuggedCom Inc. RuggedRated, ROS and eRSTP are trademarks of RuggedCom Inc. Ethernet is a trademark of Xerox Corporation. Other designations in this manual might be trademarks whose use by third parties for their own purposes would infringe the rights of the owner.
Contacting RuggedCom
Corporate Headquarters US Headquarters Europe Headquarters
RuggedCom Inc. 300 Applewood Crescent Concord, Ontario Canada, L4K 5C7
Tel: +1 905 856 5288 Fax: +1 905 856 1995 Toll-free: 1 888 264 0006
RuggedCom 1930 Harrison St., Suite 209 Hollywood, Florida USA, 33020
Tel: +1 954 922 7938 ext. 103 Fax: +1 954 922 7984 Toll-free: 1 888 264 0006
RuggedCom Unit 41, Aztec Centre, Aztec West, Almondsbury, Bristol United Kingdom BS32 4TD
Tel: +44 1454 203 404 Fax: +44 1454 203 403
Email: RuggedSales@RuggedCom.com
Technical Support
Toll Free (North America): 1 866 922 7975 International: +1 905 856 5288 Email: Support@RuggedCom.com
Web: www.RuggedCom.com
2010 RuggedCom Inc. All rights reserved Rev105
2
Federal Communications Commission
Radio Frequency Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his expense.
Caution
This product contains a laser system and is classified as a “CLASS 1 LASER PRODUCT”. Use of controls or adjustments or performance of procedures other than those specified herein
may result in hazardous radiation exposure. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Should this device require service see the “Warranty” section of this installation guide.
Important
This unit should be installed in a restricted access location where access can only be gained by service personnel or users who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken; and access is through the use of a tool or lock and key, or other means of security, and is controlled by the authority responsible for the location.
2010 RuggedCom Inc. All rights reserved Rev105
3
Table of Contents
1 Product Overview.....................................................................................................................5
1.1 RS900G Family Front Panel Description........................................................................ 6
1.2 RS900G Family Bottom View......................................................................................... 7
2 Installation................................................................................................................................8
2.1 DIN Rail Mounting........................................................................................................... 8
2.2 Power Supply Wiring and Grounding..............................................................................9
2.2.1 HI Power Supply Wiring and Grounding.....................................................................9
2.2.2 DC Power Supply Wiring and Grounding..................................................................10
2.3 HIPOT (Dielectric Strength) Testing ..............................................................................11
2.4 Failsafe Output Wiring and Specifications.....................................................................12
2.5 RS232 Port Wiring.........................................................................................................13
2.6 RJ45 Ports – Signal Description....................................................................................14
3 Technical Specifications.........................................................................................................15
3.1 Operating Environment..................................................................................................15
3.2 Power Supply Specifications..........................................................................................15
3.3 Failsafe Relay Specifications.........................................................................................15
3.4 Twisted Pair Data Port Specifications............................................................................16
3.5 Fiber Optical Port Specifications....................................................................................16
3.6 Physical Dimensions......................................................................................................17
4 Type Tests .............................................................................................................................18
4.1 IEC 61850-3 Type Tests................................................................................................18
4.2 IEEE 1613 Type Tests...................................................................................................19
4.3 IEC Environmental Type Tests......................................................................................19
4.4 Agency Approvals..........................................................................................................20
5 Warranty.................................................................................................................................20
2010 RuggedCom Inc. All rights reserved Rev105
4
1 Product Overview
The RuggedSwitch™ RS900G is an industrially hardened, fully managed Ethernet switch providing dual fiber optical Gigabit Ethernet ports and eight Fast Ethernet copper ports. Designed to operate reliably in harsh industrial environments, the RS900G provides a high level of immunity to electromagnetic interference and heavy electrical surges typical of environments found in electric utility substations, factory floors or in curb side traffic control cabinets. An operating temperature range of -40°C to +85°C coupled with hazardous location certification, a galvanized steel enclosure and optional conformal coating allows the RS900G to be placed in almost any location.
The embedded Rugged Operating System (ROS as Enhanced Rapid Spanning Tree (eRSTP functionality for high network availability and manageability.
Ethernet Ports
2 - Fiber Optic Gigabit-Ethernet Ports 8 - Fast Ethernet Ports (10/100BaseTX) Full compliance with IEEE: 802.3, 802.3u
and 802.3z
Non-blocking, store and forward switching Full duplex operation and flow control (IEEE
802.3x) Industry standard fiber optical connectors: LC, SC, SFP
Bi-Directional simplex fiber support Long haul optics allow Gigabit distances up
to 70km
RuggedRated
for Reliability in Harsh
Environments
Meets IEEE 1613 (electric utility substations) Exceeds IEC 61850-3
(electric utility substations) Exceeds IEEE 61800-3 (variable speed drive systems) Exceeds IEC 61000-6-2 (generic industrial environment) Exceeds NEMA TS-2 (traffic control equipment) Hazardous Location Certification: Class 1 Division 2
-40 to +85°C operating temperature (no fans) Conformal coated circuit boards (optional) 20 AWG galvanized steel enclosure
) provides advanced networking features such
), Port Rate Limiting and a full array of intelligent
Universal Power Supply Options
Fully integrated power supply Universal high-voltage range: 88-300VDC or
85-264VAC Dual low-voltage DC inputs (12, 24 or 48 VDC) CSA/UL 60950 safety approved to +85°C
Simple Plug and Play Operation
Automatic learning of up to 8192 MAC addresses
Auto-negotiation on all 10/100BaseTX ports Auto-MDI/MDIX (crossover) on all
10/100BaseTX ports LED indicators for link, activity and speed
ROS™
Enhanced Rapid Spanning Tree (eRSTP
Advanced Network Management
TM
) Quality of Service (802.1p) for real-time traffic
Port rate limiting: 128kbps to 8Mbps VLAN (802.1q) with double tagging IGMP Snooping for multicast filtering Port configuration, status, statistics,
mirroring, security
Loss of link management on fiber ports Web-based, Telnet, CLI management
interfaces
SNMP v2 and RMON Rich set of diagnostics with logging and
alarms
2010 RuggedCom Inc. All rights reserved Rev105
5
1.1 RS900G Family Front Panel Description
Figure 1.1.1 RS900G Front Panel View
ITEM Activity Comments
Solid Link Established LINK LED (Yellow)
Blinking Tx/Rx Activity
Power LED Solid Power On
Alarm LED Solid Alarm condition exists
6
2010 RuggedCom Inc. All rights reserved Rev105