RuggedCom MediaConverter, RMC-100-MM, RMC-10-MM, Rugged MediaConverter Series Installation Manual

Rugged MediaConverter
Installation Guide
RuggedCom Inc. 300 Applewood Crescent Concord, Ontario Canada L4K 5C7
Web: http://www.ruggedcom.com/ Tel: +1 905 856 5288 Fax: +1 905 856 1995 Toll Free: 1 888 264 0006
Copyright
COPYRIGHT © 2010 RuggedCom Inc. ALL RIGHTS RESERVED Dissemination or reproduction of this document, or evaluation and communication of its contents, is
not authorized except where expressly permitted. Violations are liable for damages. All rights reserved, particularly for the purposes of patent application or trademark registration.
This document contains proprietary information, which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced or translated to another language without the prior written consent of RuggedCom Inc.
Disclaimer of liability
We have checked the contents of this manual against the hardware and software described. However, deviations from the description cannot be completely ruled out.
RuggedCom shall not be liable for any errors or omissions contained herein or for consequential damages in connection with the furnishing, performance, or use of this material.
The information given in this document is reviewed regularly and any necessary corrections will be included in subsequent editions. We appreciate any suggested improvements. We reserve the right to make technical improvements without notice.
Registered Trademarks
Rugged MediaConverter™, ROS™ and RuggedMC™ are trademarks of RuggedCom Inc. Other designations in this manual might be trademarks whose use by third parties for their own purposes would infringe the rights of the owner.
Important:
The Rugged MediaConverterTM (RuggedMCTM) contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Warning: Changes or modifications not expressly approved by RuggedCom Inc. could void the user’s authority to operate the equipment.
TM
The RuggedMC gained by service personnel or users who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken; and access is through the use of a tool or lock and key, or other means of security, and is controlled by the authority responsible for the location.
should be installed in a restricted access location where access can only be
RuggedCom
®
2
RuggedMC™ RMC Installation Guide rev105
Contacting RuggedCom
Corporate Headquarters US Headquarters Europe Headquarters
RuggedCom Inc. 300 Applewood Crescent Concord, Ontario Canada, L4K 5C7
Tel: +1 905 856 5288 Fax: +1 905 856 1995 Toll-free: 1 888 264 0006
Technical Support
Toll Free (North America): 1 866 922 7975 International: +1 905 856 5288 Email: Support@RuggedCom.com
RuggedCom 1930 Harrison St., Suite 209 Hollywood, Florida USA, 33020
Tel: +1 954 922 7938 ext. 103 Fax: +1 954 922 7984 Toll-free: 1 888 264 0006
RuggedCom Unit 41, Aztec Centre, Aztec West, Almondsbury, Bristol United Kingdom BS32 4TD
Tel: +44 1454 203 404 Fax: +44 1454 203 403
Email: RuggedSales@RuggedCom.com
Web: www.RuggedCom.com
Rug
ged
Com
®
3
RuggedMC™ RMC Installation Guide rev105
Table of Contents
Table of Contents
1 Product Overview.................................................................................................................... 5
1.1 Functional Overview....................................................................................................... 5
1.2 Feature Highlights........................................................................................................... 5
1.3 RuggedMC
1.4 RuggedMC
2 Installation............................................................................................................................... 8
2.1 DIN Rail Mounting........................................................................................................... 8
2.2 Power Supply Wiring and Grounding..............................................................................9
2.3 RJ45 Ports – Signal Description....................................................................................10
2.4 Fiber Optical Port Configuration.....................................................................................12
3 Technical Specifications.........................................................................................................14
3.1 Power Supply Specifications..........................................................................................14
3.2 Networking Standards Supported..................................................................................14
3.3 Copper Port Specifications............................................................................................15
3.4 Fiber Optical Specifications...........................................................................................15
3.5 Networking Specifications..............................................................................................15
3.6 Operating Environment..................................................................................................15
3.7 Physical Dimensions......................................................................................................16
4 Type Tests..............................................................................................................................17
4.1 IEC 61850-3 Type Tests................................................................................................17
4.2 IEEE 1613 Type Tests...................................................................................................18
4.3 IEC Environmental Type Tests......................................................................................18
5 Agency Approvals ..................................................................................................................19
6 Warranty.................................................................................................................................19
TM
Front Panel Description............................................................................ 6
TM
Side and Bottom View.............................................................................. 7
Rug
ged
Com
®
4
RuggedMC™ RMC Installation Guide rev105
Product Overview
1 Product Overview
1.1 Functional Overview
The Rugged MediaConverterTM is an industrially hardened fiber optical media converter specifically designed to operate in harsh environments such as those found in electric utility substations and factory floors. The RuggedMCTM family provides industrial strength Ethernet copper-to-fiber media conversion, allowing for 10BaseT-to-10BaseFL or 100BaseTX-100BaseFX over multi-mode or optional single-mode fiber optical media.
Specifically tested to the same standards as mission critical protective relaying equipment (i.e. ANSI/IEEE C37.90 and IEC 60255), and the newly issued IEC 61850-3 “Communications Systems and Networks in Substations” standard, the RuggedMCTM is ideally suited for substation or industrial environments. The reliability of the Rugged MediaConverterTM family exceeds that of commercial media converters by having no rotating mechanical parts (i.e. no cooling fans), utilizing high-temperature solid state components and incorporating the necessary transient and surge suppression circuitry required for substation and harsh industrial environments.
1.2 Feature Highlights
Utility Grade (i.e. substation hardened) per ANSI/IEEE C37.90, IEC 60255, and the new IEC
61850-3 (2002), IEC 61000-6-5 standards
Operating temperature: -40 to 85C (no fan) Radiated RF Immunity: 35V/m per ANSI/IEEE C37.90.2 Power supply options: 24 (18-36VDC), 48 (36-72) or HI (88-300VDC / 85-264VAC) Choice of two fiber optical modules:
1 – 100BaseFX (100Mbps) multimode or optional single-mode fiber optical port
1 - 10BaseFL (10Mbps) multimode or optional single-mode fiber optical port 1 – 10/100BaseTX Auto-Negotiating RJ45 port Configurable Full-Duplex, Half-Duplex or Fiber-side negotiation supportLink Pass Through supportTIA/EIA-785 100BaseSX support (10FL module only)
RuggedCom
®
5
RuggedMC™ RMC Installation Guide rev105
Product Overview
1.3 RuggedMC
TM
Front Panel Description
Figure 1: RuggedMCTM Front Panel Detail
ITEM Activity Comments
Copper Side: Link Solid (Yellow) Link Established Copper Side: Activity Blinking (Yellow) Tx, Rx Activity Fiber Side: Link Solid (Yellow) Link Established Fiber Side: Activity Blinking (Yellow) Tx, Rx Activity Power LED Solid (Green) Power On
RuggedCom
®
6
RuggedMC™ RMC Installation Guide rev105
Loading...