This Mounting Guide provides step-by-step instructions on how to field-install the Ruckus Wireless ZoneDirector SC8800-S access point (AP), part number 9x1-8800-xxxx. For detailed information on planning the installation, pointing the internal GPS antenna, performing a site survey, preparing the SC8800-S at the depot, and shipping to the field, refer to the ZoneFlex SmartCell SC8800-S Outdoor Access Point Installation Guide. For information on operating the SC8800-S, refer to the ZoneFlex Outdoor Access Point User Guide. Both documents are available at https://
support.ruckuswireless.com.
WARNING: Only trained and qualified personnel should be allowed to
install, replace, or service this equipment.
WARNING: Installation of this equipment must comply with local and
national electrical codes.
CAUTION: Make sure that you form a 80mm - 130mm (3”-5”) drip
loop in any cable that is attached to the AP or the building. This will prevent water from running along the cable and entering the AP or the building where the cable terminates.
CAUTION: Be sure that grounding is available and that it meets local
and national electrical codes. For additional lightning protection, use lightning rods and lightning arrestors.
CAUTION: Make sure that proper lightning surge protection
precautions are taken according to local electrical code.
WARNING: Ruckus Wireless strongly recommends that you wear eye
protection before mounting the SC8800-S.
THIS GUIDE IN OTHER LANGUAGES
请从以下网站获得该指南的简体中文版
https://support.ruckuswireless.com
.
Vous trouverez la version française de ce guide à l'adresse suivante
https://support.ruckuswireless.com
.
こ のガ イ ド の 日本語版 は https://support.ruckuswireless.com
でご覧くだ さい。
가이드의 한국어 버전은 사이트 (https://support.ruckuswireless.com
) 에서 확인하시기 바랍니다 .
Veja a versão em português (Brasil) deste guia em
https://support.ruckuswireless.com.
Puede ver la versión en español (América Latina) de esta guía en
https://support.ruckuswireless.com.
BEFORE YOU BEGIN
Before deploying your Ruckus Wireless SC8800-S, verify that all items listed in Package Contents
are included in the package. If any item is damaged or missing, notify your authorized Ruckus Wireless sales representative. Also, make sure that you have the required hardware and tools.
REQUIRED HARDWARE AND TOOLS
• Customer-supplied outdoor-rated three-wire (1-2mm2 or 14-
18AWG) AC cable
• Customer-supplied earth-ground wire (3-5mm
2
or 10-12 AWG)
• 1/2” (13mm) flat-blade screwdriver or equivalent
• No. 2 Phillips screwdriver
• Small flat-blade screwdriver
• Torque wrench or torque screwdriver with sockets
• Long-nose pliers
• Electrical wire stripping and terminal crimping pliers
• Pipe or pole --OR-- a sturdy flat surface
• Electric drill with drill bits and customer-supplied wall anchors, flat
washers, and hex nuts for flat-surface mount
• Two customer-supplied M16 (5/8”) carriage bolts for main
mounting bracket on a wooden pole
• Four customer-supplied 6mm (1/4“) bolts or screws for main
mounting bracket --OR-­Four customer-supplied 14mm (1/2“) bolts or screws for main mounting bracket --OR--
Four factory-supplied 1/2” (12.7mm) wide stainless steel adjust­able clamps, 2.5” (63.5mm) diameter, for main mounting bracket on smaller poles --OR--
Two 7/8” customer-supplied (22mm) wide stainless steel adjust­able clamps for main mounting bracket on larger poles
•Ruler
PACKAGE CONTENTS
A complete SC8800-S field installation package includes all of the items listed below:
• SC8800-S Access Point (A in Figure 1), includes crimp-type earth-
ground ring terminal
• Two M25 data cable glands (B in Figure 1)
• One main mounting bracket (C in Figure 1)
• One U-joint bracket (D in Figure 1)
• Nine sets 12mm M6 x 1 hex bolt with lock and flat washers
(E in Figure 1)
• One hook bracket (F in Figure 1)
• One set 70mm M8x1.25 hex bolt with spring lock and flat washers (G in Figure 1)
• One AP attachment bracket (H in Figure 1)
• Four SAE32 steel clamps, 2.5-inch diameter (I in Figure 1)
• One AC power cable input end connector and cap (J in Figure 1)
• One safety cable (K in Figure 1)
•This Mounting Guide
Figure 1: SC8800-S field-installation package contents
The field installation package can also include:
• Service Level Agreement/Limited Warranty Statement
• Regulatory Statement
• Registration card
• Declaration of Conformity, if required
NOTE: This kit can include extra screws, nuts and washers. You may use the extras wherever required.
STEP 1: CONNECTING AND SEALING THE RJ-45 C
ABLES
The SC8800-S may use zero, or one or two RJ-45 cables, one for Ethernet when configured as a Root AP (RAP), and one when the SC8800-S is supplying PoE out to a peripheral device, such as a small cell or micro cell radio. When the SC8800-S uses RJ-45 cables, connect and seal the cables using the M25 data cable glands (B in Figure 1). 1 Feed the end of the cable through the sealing nut, rubber O-ring,
clamping ring assembly and cable gland base as shown in Figure
2.
CAUTION! THE MINIMUM SOFTWARE REVISION FOR
THE SC8800-S IS ZONEFLEX (ZF) 9.6.1 OR LATER.
DO NOT CONNECT THE SC8800-S TO A RUCKUS WIRELESS CONTROLLER WITH ZF 9.6.0 OR EARLIER.
F G
H
E
A C
B
D
I
J K
Copyright © 2014 Ruckus Wireless, Inc. Published January 2014, Part Number 800-70548-001 Rev C
Page 2 of 4
Figure 2: RJ-45 cable and cable gland assembly
2 Use a wide flat-blade screwdriver to remove the required (RESET/
PoE OUT or PoE IN) blanking cap from the SC8800-S.
3 Connect the cable to the Ethernet port in the SC8800-S. 4 Tighten the cable gland base into the SC8800-S chassis to 7 N.m
or 62 in-lbs.
5 Wrap the clamping ring assembly around the rubber O-ring. Make
sure that the clamping ring assembly fully encloses the rubber O­ring.
6 Seat the clamping ring assembly and rubber O-ring in the cable
gland base.
7 Hand-tighten the sealing nut.
STEP 2: MOUNTING THE U-JOINT BRACKET TO THE M
AIN MOUNTING BRACKET
1 Position the U-joint bracket on the main mounting bracket. (Note
the orientation; generally horizontal to allow altitude adjustments.)
Figure 3: U-joint bracket attached horizontally to the main mounting bracket
2 Use four M6 bolt and washer sets (A) to mount the U-joint bracket
(B) to the main mounting bracket (C). Tighten the bolts to 9.5 N.m (7 ft-lbs).
3 Continue with Step 3a, 3b or 3c.
STEP 3A: ATTACHING THE MAIN MOUNTING B
RACKET TO A FLAT SURFACE
1 Place the main mounting bracket at the location on the mounting
surface where you want to mount the AP. Use the holes on the main mounting bracket as a template to mark the locations of the mounting holes, A for large bolts or B for small bolts.
Figure 4: Main mounting bracket flat surface holes
2 Remove the main mounting bracket from the mounting surface. 3 Drill holes required for the mounting hardware. 4 Attach the main mounting bracket to the flat surface using the
mounting hardware. Note the UP direction.
5 Using the mounting hardware instructions, tighten the hardware to
secure the main mounting bracket.
6 Continue with Step 4.
STEP 3B: ATTACHING THE MAIN MOUNTING B
RACKET TO A WOODEN POLE
1 Place the main mounting bracket at the location on the mounting
surface where you want to mount the AP. Use the square holes on the main mounting bracket as a template to mark the locations of the mounting holes.
Figure 5: Wooden pole mounting hole locations
2 Remove the main mounting bracket from the pole. 3 Drill holes for the M16 (5/8”) carriage bolts as required by the local
pole owner.
4 Attach the main mounting bracket to the flat surface using the
carriage bolts. Note the UP direction.
5 Using carriage bolt nuts, tighten the carriage bolts as required by
the local pole owner to secure the main mounting bracket.
6 Continue with Step 4.
STEP 3C: ATTACHING THE MAIN MOUNTING B
RACKET TO A METAL POLE
1 Insert the open end of one steel clamp into the upper two slots on
the main mounting bracket, narrow slots (A) for smaller poles or wide slots (B) for larger poles.
Figure 6: Adjustable clamp slots for a vertical pole
2 Take the other steel clamp and insert it into the lower two slots on
the main mounting bracket.
3 Use the clamps to attach the main mounting bracket to the pole.
Note the UP direction. Tighten the clamps to 3 N.m or 27 in-lbs, or per manufacturer’s specifications.
Figure 7: Attaching the main mounting bracket to a vertical pole
4 Continue with Step 4.
STEP 4: MOUNTING THE HOOK BRACKET TO THE U-J
OINT BRACKET
The hook bracket attaches to the U-joint bracket using the M8 bolt and washer set.
NOTE: The AP can be mounted outdoors in any orientation, as long
as the internal GPS antenna is pointed up or toward a mostly­unobstructed view of the sky.
Figure 8: Preferred GPS antenna position
Cable gland base
Clamping ring assembly
Rubber O-ring
Sealing nut
C
A
B
UP
A
B
UP
A
UP
A
B
UP
A B
Keep Clear
Sky View
Loading...
+ 2 hidden pages