Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator, Magnetic Flow Meter Simulator - 8712D, 8700 Series Quick Start Guide

Quick Start Guide
00825-0100-4764, Rev DA
Rosemount® 8714D (Calibration Standard) Magnetic Flowtube Simulator
March 2014
March 2014
NOTICE
This document provides basic guidelines for the Rosemount 8714D. It does not provide instructions for detailed configuration, diagnostics, maintenance, service, troubleshooting. This QSG is also available electronically on www.rosemount.com.
Explosions could result in death or serious injury.
Installation of this device in an explosive environment must be in accordance with the appropriate local, national, and international standards, codes, and practices. Please review the Product Certifications section for any restrictions associated with a safe installation.
Before connecting a Field Communicator in an explosive atmosphere, ensure the instruments are installed
in accordance with intrinsically safe or non-incendive field wiring practices.
Electrical shock can result in death or serious injury.
Avoid contact with the leads and terminals. High voltage that may be present on leads can cause electrical shock.
Contents
8714D introduction . . . . . . . . . . . . . . . . . page 3
Step 1: Change transmitter parameters page 3
Step 2: Connect wiring and power-up . . page 3
2
Step 3: Perform electronics trim . . . . . . .page 4
Step 4: Verify Rosemount 8714D flowtube
simulator . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
March 2014
Quick Start Guide

8714D introduction

The Rosemount 8714D is a high-precision instrument that can be used to recalibrate the following transmitters 8712 C/D/E, 8732 C/E, and the 8742C. The 8714D supplies an exact voltage, precisely simulating flow rates of 0.00 ft/s, 3.00 ft/s, 10.00 ft/s, and 30.00 ft/s. The precise 30.00 ft/s voltage signal may be used to recalibrate or verify operation of the transmitter. Perform this procedure only if
you believe that the transmitter is no longer accurate.

Step 1: Change transmitter parameters

1. Use a Field Communicator or Local Operator Interface (LOI) to change the parameters of the transmitter to the following:
Tube Calibration Number: 1000015010000000Units: ft/sAnalog Output Range: 20mA = 30.00 ft/sAnalog Output Zero: 4mA = 0 ft/sCoil Pulse Mode: 5 Hz (6Hz 8712C only)
2. Set the loop to manual (if necessary).
3. Power down the transmitter.

Step 2: Connect wiring and power-up

1. Insert the metal end of the wiring assembly into the 8714D Calibration Standard.
2. Connect the transmitter.
For 8712, see Figure 1.For 8732/8742, see Figure 2.

Rosemount 8712 (Figure 1)

Use the six contact pin terminal plug-style wiring assembly. Follow the numeric convention for the 8712 so the plugs match the terminal block.
Figure 1. 8712 Terminal Block
3

Rosemount 8732/8742 (Figure 2)

Use the two black connector-style wiring assembly (one connector has four contacts, the other has three.) Remove the electronics side cover (furthest away from the conduit plugs). If you do not have a LOI, the connectors will be clearly visible on the bottom side of the board. If you have a LOI, remove the three mounting screws from the LOI assembly and pull the display assembly away from the connector assembly until the connector assembly on the back of the board is fully released. Then, plug the calibrator connectors into the appropriate receptacles.
Figure 2. Rosemount 8732E Electronics
March 2014
Attempting an electronics trim without a Rosemount 8714D may result in an inaccurate transmitter. It may also generate a DIGITAL TRIM FAILURE message. If this message appears, no values were changed in the transmitter. Simply power down the transmitter to clear the message. If the trim was completed, or no error message was generated, correction requires a Rosemount 8714D.

Step 3: Perform electronics trim

1. Set the Rosemount 8714D to simulate a flow rate of 30 ft/s.
2. Power up the transmitter with the Rosemount 8714D connected. Allow the electronics 30 minutes to warm-up before reading the flow rate.
3. Read the flow rate. It should be between 29.97 and 30.03 ft/s. If the reading is within this range, return the transmitter to the original configuration. If the reading is not within this range, continue to
flowtube simulator page 5
.
4. Initiate an electronics trim with the LOI or Field communicator. The electronics trim takes about six minutes to complete. No transmitter adjustments are required.
HART Fast Keys 1.5
LOI Auxiliary Function
4
Step 4: Verify Rosemount 8714D
March 2014
Test setup for method 1
Front panel connections
Quick Start Guide

Step 4: Verify Rosemount 8714D flowtube simulator

Procedure for verifying the Model 8714D flowtube simulator

The Rosemount model 8714D Flowtube Simulator is a “Calibration Standard” made to operate specifically with the Rosemount models 8712 C/D/E, 8732 C/E, and the 8742C Magnetic Flowmeter Transmitters. The 8714D simulates a sensor coil load. It accurately produces a simulated flow signal for the purpose of transmitter calibration.
Note
Rosemount strongly encourages the 8714D be sent back to the factory to be calibrated. Typically on a yearly basis.

Method 1 verification: required equipment

NIST* traceable DC current source capable of sourcing 500mA. Accuracy
should be +/- 0.1%.
NIST traceable DMM (voltmeter). For example the Agilent 34401A or
equivalent.
*NIST stands for “National Institute of Standards and Technology”
Limitations
Current thru terminals 1 and 2 should not exceed 600mA. Limit the output voltage on the current source to 12 VDC max. This is to
protect the 8714D input at pins 1 and 2 and also for operator safety.
Calibration shall occur with the 8714D standard set at 30 per feet per second.
Figure 3. Test setup for method 1 and the front panel connection
5
Tes t se tup for met ho d 1
March 2014
Method 1 - verification procedure
1. Set the output voltage limit on the current source to 12VDC max.
2. Set the current source output to 500mA dc.
3. Connect the current source to the 8714D input terminals 1 and 2 as shown in the test setup diagram.
4. Allow the 8714D to stabilize for 30 minutes.
5. Measure and record the average voltage at pins 18 and 19 over a 5 minute span.
6. The value should equate to 1.078mV ±.05%.
Note
If your device does not operate within this specification, return the Rosemount 8714D to the Rosemount factory for calibration.

Method 2 verification: required equipment

DC voltage source. Set current limit to 600mA NIST traceable 1 ohm, 1 watt precision resistor; 10ppm, measurable to 5 digits
(for example the Tegam SR1-1)
NIST traceable DMM(s) (voltmeter); (for example, the Agilent 33401A or
equivalent)
Limitations
Current through terminals 1 and 2 should not exceed 600mA. Calibration shall occur with the 8714D standard set at 30 per feet per second.
Figure 4. Test setup for method 2
Method 2 - verification procedure:
1. Verify the DC power supply is at 0 volts.
2. Connect the supply as shown in the above diagram.
3. Gradually increase the DC power supply voltage until 0.5V is measured across the 1 ohm sense resistor (R
6
).
in
March 2014
Quick Start Guide
4. Allow the 8714D to stabilize for 30 minutes.
5. Re-verify the voltage across R
= 0.5V.
in
6. Measure and record the average voltage at pins 18 and 19 over a 5 minute span. Also, measure and record the average voltage across Rin over the same 5 minute span. This will be VRin.
7. Calculate IRin as (VRin / 1).
8. Due to the possible variation of IR
over the 5 minute time period, the
in
expected value at pins 18 and 19 can be calculated as:
/0.500)*1.078mV] = expected value across pins 18 and 19 ± 0.05%.
[(IR
in
9. For example:
If the measured current through R
is 499mA, then:
in
[(0.499)/(0.500)]*1.078mV=1.075mV ± 0.05% at pins 18 and 19
If the measured current through R
is 501mA, then:
in
[(0.501)/(0.500)]*1.078mV=1.080mV ± 0.05% at pins 18 and 19
If the measured current through R
is 500mA, then:
in
[(0.500)/(0.500)]*1.078mV=1.078mV ± 0.05% at pins 18 and 19
Note
If your device does not operate within this specification, return the Rosemount 8714D to the Rosemount factory for calibration.
Within the United States, Rosemount Inc. has two toll-free assistance numbers.
Tel (USA) 800 522 6277
Customer Support Center:
North American Response Center:
(7:00 a.m. to 7:00 p.m. CST) Technical support, quoting, and order-related questions.
1-800-654-7768 (24 hours a day - Includes Canada) Equipment service needs.
7
?00825-0100-4764I?
Quick Start Guide
00825-0100-4764, Rev DA
March 2014
Emerson Process Management Rosemou nt Inc.
8200 Market Boulevard Chanhassen, MN 55317 USA www.rosemount.com T (USA) +1 800 522 6277 T (International) +1 (303) 527 5200 F +1 (303) 530 8459
Emerson Process Management Asia Pacific Priva te Limited
1 Pandan Crescent Singapore 128461 T (65) 6777 8211 F (65) 6777 0947 Enquiries@AP.EmersonProcess.com
Emerson Process Management Flow B. V.
Neonstraat 1 6718 WX Ede The Netherlands T +31 (0) 318 495555 F +31 (0) 318 495556
Emerson FZE
P.O. Box 17033 Jebel Ali Free Zone Dubai UAE T +971 4 811 8100 F +971 4 886 5465 FlowCustomerCare.MEA@Emerson.com
Emerson Process Management Latin America
Multipark Office Center Turrubares Building, 3rd & 4th floor Guachipelin de Escazu, Costa Rica T+(506) 2505-6962 international.mmicam@emersonprocess.com
© 2014 Rosemount Inc. All rights reserved. All marks property of owner. The Emerson logo is a trade mark and service mark of Emerson Electric Co Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc.
Loading...