Specification and selection of product materials, options, or components must be made by the purchaser of the equipment. See page 9
for more information on material selection.
Table 1. Rosemount 2088 Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to
additional delivery lead time.
ModelProduct description
2088Pressure Transmitter
Measurement type
AAbsolute
GGage
★
★
★
Pressure ranges
Rosemount 2088GRosemount2088A
1–14.7 to 30 psi (–1,01 to 2,1 bar)0 to 30 psi (0 to 2,1 bar)
2–14.7 to 150 psi (–1,01 to 10,3 bar)0 to 150 psi (0 to 10,3 bar)
3–14.7 to 800 psi (–1,01 to 55,2 bar)0 to 800 psi (0 to 55,2 bar)
4–14.7 to 4,000 psi (–1,01 to 275,8 bar)0 to 4,000 psi (0 to 275,8 bar)
Transmitter ou tput
S4–20 mA dc/Digital HART Protocol
N1–5 Vdc Low Power/Digital HART Protocol
Materials of construction
Process connectionIsolating diaphragmFill fluid
22316L SST316L SSTSilicone
33Alloy C-276Alloy C-276Silicone
2B316L SST316L SSTInert
(1)
(2)
Emerson.com/Rosemount
★
★
★
★
★
★
★
★
3
Rosemount 2088
September 2017
Table 1. Rosemount 2088 Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to
additional delivery lead time.
Process connection
A
B
D
C
(3)
(3)(4)
(3)(4)
1
/2–14 NPT female
DIN 16288 G 1/2 male
M20 1.5 male
RC 1/2 female
Conduit entry
1
2
4
(3)
(3)(5)
1
/2–14 NPT
M20 1.5
G 1/2
Options (Include with selected model number)
Extended product warranty
★
★
★
★
★
WR33-year limited warranty
WR55-year limited warranty
Diaphragm seal assemblies
(6)(7)
S1Assemble to one Rosemount 1199 Diaphragm Seal
Display and interface
M4LCD display with local operator interface
M5LCD display, configured for engineering units
Configuration buttons
D4Analog zero and span
DZdigital zero trim
Mounting brackets
B4SST mounting bracket with SST bolts
Product certifications
C6Canada Explosionproof, Intrinsic Safety, Division 2, and Dust-Ignitionproof
E2INMETRO Flameproof
E3China Flameproof
(3)(8)
E4
E5USA Explosionproof (XP) and Dust-Ignitionproof (DIP)
E7IECEx Flameproof
EDAT EX Fla meproof
EMTechnical Regulations Customs Union (EAC) Flameproof
(3)
I1
I2INMETRO Intrinsic Safety
Japan Flameproof
ATEX Intrinsic Safety
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
★
4
Emerson.com/Rosemount
September 2017
Rosemount 2088
Table 1. Rosemount 2088 Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to
additional delivery lead time.
I3China Intrinsic Safety
I5USA Intrinsic Safety (IS) and Nonincendive (NI)
I7IECEx Intrinsic Safety
IMTechnical Regulation Customs Union (EAC) Intrinsic Safety
K1ATEX Flameproof, Intrinsic Safety, Type n, Dust
K2INMETRO Flameproof, Intrinsic Safety
K5USA Explosionproof, Dust-Ignitionproof, Intrinsic Safety, and Nonincendive
(3)
K6
K7IECEx Flameproof, Intrinsic Safety, Type n, Dust
Q8Material traceability certification per EN 10204 3.1
Q15Certificate of compliance to NACE® MR0175/ISO 15156 for wetted materials
Q25Certificate of compliance to NACE MR0103 for wetted materials
Emerson.com/Rosemount
★
★
★
★
★
5
Rosemount 2088
September 2017
Table 1. Rosemount 2088 Pressure Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to
additional delivery lead time.
Digital signal
(3)
C4
CN
C5
(9)(10)
C7
(10)
C8
Conduit plug
NAMUR alarm and saturation levels, high alarm
(3)
NAMUR alarm and saturation levels, low alarm
(9)(10)
Custom alarm and saturation levels, high alarm (requires C9 and Configuration Data Sheet)
Custom alarm and saturation levels, low alarm (requires C9 and Configuration Data Sheet)
Low alarm (Standard Rosemount alarm and saturation levels)
(11)
★
★
★
★
★
DO316 SST conduit plug
Configuration
C9Software configuration
Manifold assemblies
(6)(7)
S5Assemble to Rosemount 306 Integral Manifold
Calibration accuracy
(12)
P80.065% accuracy to 10:1 turndown
Water approval
(13)
DWNSF drinking water approval
Surface finish
Q16Surface finish certification for sanitary remote seals
Toolkit total system performance reports
QZRemote seal system performance calculation report
HART Revision configuration
(14)
HR 5
HR7
Configured for HART Revision 5
(15)
Configured for HART Revision 7
(10)
★
★
★
★
★
★
★
★
★
Typical model number: 2088 G 2 S 22 A 1 B4 M5
1.HART Revision 5 is the default HART output. The Rosemount2088 with selectable HART can be factory or field configured to HART Revision 7. To order HART Revision 7
factory configured, add option code HR7.
2.Materials of construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain
materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
3.Not available with Low Power transmitter output code N.
4.Not available with Alloy C-276, materials of construction code 33.
5.Consists of a
6.Use
7.“Assemble-to” items are specified separately and require a completed model number.
8.Only available with conduit thread code 4.
9.Only available with 4–20 mA HART output (output code A).
10.Select configuratio n buttons (option code D4 or DZ) or local operator interface (option code M4) if local configuration buttons are required.
11.Transmitter shipped with 316SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
12.Requires transmitter output code S with either materials of construction code 22 or 23.
13.Requires materials of construction code 22 with process connection code A.
14.Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
15.Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
6
1
/2–14 NPT housing with a G1/2 adapter.
1
/2–14 NPT female process connection code A.
Emerson.com/Rosemount
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.