Roland Picza PIX-4, Picza PIX-30 User Manual

Thank you very much for purchasing the PIX-4.
To ensure correct and safe usage with a full understanding of this product's performance, please be sure to read through this manual completely and store it in a safe location.
Unauthorized copying or transferral, in whole or in part, of this manual is prohibited.
The contents of this operation manual and the specifications of this product are subject to change without notice.
The operation manual and the product have been prepared and tested as much as possible. If you find any misprint or error, please inform us.
USER'S MANUAL
For the USA
FEDERAL COMMUNICATIONS COMMISSION
RADIO FREQUENCY INTERFERENCE
STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Unauthorized changes or modification to this system can void the users authority to operate this equipment.
The I/O cables between this equipment and the computing device must be shielded.
For Canada
CLASS A NOTICE
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
CLASSE A AVIS
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
ROLAND DG CORPORATION 1-6-4 Shinmiyakoda, Hamamatsu-shi, Shizuoka-ken, JAPAN 431-2103 MODEL NAME : See the MODEL given on the rating plate. RELEVANT DIRECTIVE : EC MACHINERY DIRECTIVE (98/37/EC)
EC LOW VOLTAGE DIRECTIVE (73/23/EEC) EC ELECTROMAGNETIC COMPATIBILITY DIRECTIVE (89/336/EEC)
1
Windows® and Windows NT® are registered trademark or trademark of Microsoft® Corporation in the United States and/or other countries. i486 and Pentium are registered trademarks of Intel Corporation in the United States. AutoCAD® is registered trademark of Autodesk, Inc. Mac OS, Macintosh, Power Macintosh, PowerBook, and AppleTalk are registered trademarks or trademarks of Apple Computer, Inc. in the USA and other countries. PowerPC is trademark of International Business Machines Corporation.
Copyright © 1999 ROLAND DG CORPORATION
Table of Contents
To Ensure Safe Use .......................................... 2
About the Labels Affixed to the AC
Adapter and Unit ..................................... 4
Pour utiliser en toute sécurité ................... 5
À propos des étiquettes collées sur l’adaptateur AC et sur
l’appareil.......................................................7
Using PICZA (Some Examples of Actual Use) ............8
Creating elements for 3D computer graphics
software .............................................................. 8
Adding 3D graphics to an internet web page ..... 9
Cutting a three-dimensional object with a
modeling machine ............................................ 10
1 Check the included items ....................................... 11
2 Part names.............................................................. 11
3 Setting up and connection...................................... 12
4 Installing the Dr.PICZA......................................... 14
Symbols used in the section on software ......... 14
Overview of Dr. PICZA ................................... 14
Installing........................................................... 15
5 Starting Dr. PICZA ................................................ 17
About Help ................................................. 17
6 Selecting a communication port ............................ 18
7 Powering ON ......................................................... 19
8 Load the object to be scanned on the PIX-4 .......... 19
Maximum scanning area of the PIX-4 .............19
Load the object to be scanned on the PIX-4 .... 20
9 Starting scanning....................................................22
About scanning conditions
and the scanning area ...................22
Setting scanning conditions
and starting scanning.................... 22
Setting the scanning area ............................ 24
Rescanning a particular portion.................. 25
Cancels scanning/Pauses scanning ............. 25
10 Saving scanned data .............................................. 26
Edit the scanned data .................................. 26
11 Powering OFF........................................................26
When not in use .......................................... 26
12 Ending Dr. PICZA................................................. 27
13 Items that may not be copied................................. 27
14 What to do if... ....................................................... 27
15 Specifications ........................................................ 28
2
To Ensure Safe Use
Used for instructions intended to alert the user to the risk of death or severe injury should the unit be used improperly.
About and Notices
Used for instructions intended to alert the user to the risk of injury or material damage should the unit be used improperly.
* Material damage refers to damage or other adverse effects caused with
respect to the home and all its furnishings, as well to domestic animals or pets.
About the Symbols
The symbol alerts the user to important instructions or warnings. The specific meaning of the symbol is determined by the design contained within the triangle. The symbol at left means "danger of electrocution."
The symbol alerts the user to items that must never be carried out (are forbidden). The specific thing that must not be done is indicated by the design contained within the circle. The symbol at left means the unit must never be disassembled.
The symbol alerts the user to things that must be carried out. The specific thing that must be done is indicated by the design contained within the circle. The symbol at left means the power-cord plug must be unplugged from the outlet.
Do not disassemble, repair, or modify.
Doing so may lead to fire or abnormal operation resulting in injury.
Do not use with any electrical power supply that does not meet the ratings displayed on the AC adapter.
Use with any other power supply may lead to fire or electrocution.
Do not use with any power supply other than the dedicated AC adapter.
Use with any other power supply may lead to fire or electrocution.
Do not use with a damaged AC adapter, power cord, or power-cord plug or with a loose electrical outlet.
Use with any other power supply may lead to fire or electrocution.
When not in use for extended periods, unplug the AC adapter from the electrical outlet.
Failure to do so may result in danger of shock, electrocution, or fire due to deterioration of the electrical insulation.
Do not use while in an abnormal state (i.e., emitting smoke, burning odor, unusual noise, or the like).
Doing so may result in fire or electrical shock. Immediately unplug the AC adapter from the electrical outlet, and contact your authorized Roland DG Corp. dealer or service center.
3
Install on a stable surface.
Failure to do so may result in falling of the unit, leading to injury.
Do not place hands near the main unit while in operation.
Doing so may result in injury.
Do not injure or modify the electrical power cord, nor subject it to excessive bends, twists, pulls, binding, or pinching, nor place any object of weight on it.
Doing so may damage the electrical power cord, leading to electrocution or fire.
Do not allow liquids, metal objects or flammables inside the machine.
Such materials can cause fire.
Do not allow children to operate without adult supervision or operate within reach of young children.
Doing so may result in injury.
When unplugging the AC adapter from the power outlet, grasp the adapter unit or the plug, not the cord.
Unplugging by pulling the cord may damage it, leading to fire or electrocution.
Store clay out of the reach of children.
Do not attempt to unplug the AC adapter with wet hands.
Doing so may result in electrical shock.
4
: Indicates information to prevent machine breakdown or malfunction and ensure correct use.
: Indicates a handy tip or advice regarding use.
In addition to the and symbols, the symbols shown below are also used.
NOTICE
About the Labels Affixed to the AC Adapter and Unit
These labels are affixed to the body of this product and the AC adapter. The following figure describes the location. The configuration of the AC adapter varies according to regional differences in voltage. Please note that the descriptions in this manual are for the 117 V adapter.
Rating label
Do not use with any electrical power supply that does not meet the ratings displayed on the AC adapter.
When not in use for prolonged periods, unplug the AC adapter from the electrical outlet.
Front
Rear
Do not place hands near the main unit while in operation.
Model label
5
Utilisé pour avertir l'utilisateur d'un risque de décès ou de blessure grave en cas de mauvaise utilisation de l'appareil.
Avis sur les avertissements
Utilisé pour avertir l'utilisateur d'un risque de blessure ou de dommage matériel en cas de mauvaise utilisation de l'appareil.
* Par dommage matériel, il est entendu dommage ou tout autre effet
indésirable sur la maison, tous les meubles et même les animaux domestiques.
À propos des symboles
Le symbole attire l'attention de l'utilisateur sur les instructions importantes ou les avertissements. Le sens précis du symbole est déterminé par le dessin à l'intérieur du triangle. Le symbole à gauche signifie "danger d'électrocution".
Le symbole avertit l'utilisateur de ce qu'il ne doit pas faire, ce qui est interdit. La chose spécifique à ne pas faire est indiquée par le dessin à l'intérieur du cercle. Le symbole à gauche signifie que l'appareil ne doit jamais être démonté.
Le symbole prévient l'utilisateur sur ce qu'il doit faire. La chose spécifique à faire est indiquée par le dessin à l'intérieur du cercle. Le symbole à gauche signifie que le fil électrique doit être débranché de la prise.
Pour utiliser en toute sécurité
Ne pas démonter, réparer ou modifier.
Le non-respect de cette consigne pourrait causer un incendie ou provoquer des opérations anormales entraînant des blessures.
Ne pas utiliser avec une alimentation électrique autre que l’adaptateur AC conçu à cet effet.
Une utilisation avec toute autre alimentation électrique pourrait provoquer un incendie ou une électrocution.
Ne pas utiliser avec une alimentation électrique ne respectant pas les caractéristiques indiquées sur l’adaptateur AC.
Une utilisation avec toute autre alimentation électrique pourrait provoquer un incendie ou une électrocution.
Ne pas utiliser si l'appareil est dans un état anormal (c'est-à-dire s'il y a émission de fumée, odeur de brûlé, bruit inhabituel etc.).
Le non-respect de cette consigne pourrait provoquer un incendie ou des décharges électriques. Débrancher immédiatement l’adaptateur AC et contacter votre agent agréé de la compagnie Roland DG ou votre centre de service.
6
Ne pas utiliser avec un adaptateur AC ou un fil électrique endommagé ou avec une prise électrique qui a du jeu.
Une utilisation avec toute autre alimentation électrique pourrait provoquer un incendie ou une électrocution.
Quand l’appareil reste inutilisé pendant plusieurs heures, débrancher l’adaptateur AC.
Le non respect de cette consigne pourrait causer des risques de décharges électriques, d’électrocution, ou d’incendie dus à la détérioration de l’isolation électrique.
Ne pas endommager ou modifier le fil électrique. Ne pas le plier, le tordre, l'étirer, l'attacher ou le serrer de façon excessive. Ne pas mettre d'objet ou de poids dessus.
Une négligence à ce niveau pourrait endommager le fil électrique ce qui risquerait de provoquer une électrocution ou un incendie.
Lorsque vous débranchez l’adaptateur AC, saisir et tirer le bloc adaptateur et non le fil électrique.
Débrancher en tirant sur le fil pourrait l'endommager et risquer de provoquer un incendie ou une électrocution.
Ne pas débrancher l’adaptateur AC avec des mains mouillées.
Une négligence à ce niveau pourrait provoquer des décharges électriques.
Ne pas introduire de liquide, d'objet métallique ou inflammable dans l'appareil.
Ce genre de matériel peut provoquer un incendie.
Installer l’appareil sur une surface stable.
Une négligence à ce niveau pourrait provoquer la chute de l’appareil et entraîner des blessures.
Ne pas placer vos mains près de l’unité principale pendant son fonctionnement.
Le non respect de cette consigne pourrait causer des blessures.
Ne pas laisser des enfants faire fonctionner l’appareil sans la surveillance d’un adulte ni laisser l’appareil en fonctionnement à la portée d’enfants en bas âge.
Une négligence à ce niveau pourrait provoquer des blessures.
Ranger la pâte hors de la portée des enfants.
7
Nom du modèle
À propos des étiquettes collées sur l’adaptateur AC et sur l’appareil
Ces étiquettes sont collées sur le corps de l’appareil et sur l’adaptateur AC. Le dessin suivant indique leur emplacement. La configuration de l’adaptateur AC varie selon les différences de voltage régionales. Veuillez noter que les descriptions dans ce manuel correspondent à un adaptateur de 117 volts.
Étiquette des caractéristiques électriques
Ne pas utiliser avec une alimentation électrique ne respectant pas les caractéristiques indiquées sur l’adaptateur.
Quand l’appareil reste inutilisé pendant une longue période, débrancher l’adaptateur AC.
Avant
Arrière
Ne pas placer vos mains près de l’unité principale pendant son fonctionnement.
8
Using PICZA (Some Examples of Actual Use)
This section presents some actual examples of how PICZA can be put to use.
Creating elements for 3D computer graphics software
Dr. PICZA offers a function for exporting files in three-dimensional DXF format (AutoCAD® Release 12 format). This section explains how to use a commercially available 3D computer-graphics software application that can import DXF-format files to create your own original illustrations. (This product does not include 3D computer-graphics software, which must be obtained from another source.)
1
Visualize in detail the design illustration you wish to create. In this example, we'll make the illustration shown below.
2
Create the elements that make up the illustration. In this example, we'll use the clay included with the product to make the face, and the graphics software to make the other element (the pyramid).
3
Scan the clay face and export the data in DXF format.
4
Launch the 3D graphics application and import the DXF file. Make the pyramid and arrange the face and the pyramid using the layout shown below.
Use the 3D graphics software to color the illustration, then print it out.
5
DXF-format file
9
Adding 3D graphics to an internet web page
Dr. PICZA comes with a function for exporting files in VRML format (Ver.1.0). VRML (Virtual Reality Modeling Language) is a language used to display 3D graphics on the World Wide Web, where they can be viewed using a web browser capable of displaying VRML files. Color data from Dr. PICZA is also preserved in these VRML files. In this example, we'll add the image of a original fishing lure scanned with the PIX-4 to a web page. (This product does not include a web browser or web-page authoring software, which must be obtained from another source.)
1
Set the lure in place on the workpiece table and scan it with the PIX-4. In this example, we'll scan only one side of the lure, and use Dr. PICZA's [Add Backside Faces] function to make a complete three­dimensional representation.
2
Use Dr. PICZA to color the scanned data. (For details on adding color, please refer to the help screens for Dr. PICZA.)
3
Under [File] - [Preferences...], click [Add Backside Faces] to turn it on, then export the data in VRML format.
4
VRML files can be opened and viewed with a web browser that supports the VRML format. By adding a link to a VRML file from a web page, you can also display the VRML file on the World Wide Web. (For details on how to do this, please refer to the documentation for your web-page authoring software or a third­party guide to HTML.)
VRML-format file
10
1
Get a suitable leaf from a tree, and press it into a piece of clay to transfer the image of the leaf to the clay.
2
Set the piece of clay on the workpiece table and scan it with the PIX-4.
3
Use [Edit] - [Invert] to invert the scanned shape, then export the data to MODELA PLAYER.
4
Use MODELA PLAYER to cut the shape on the MODELA.
5
Color the cut object.
Before inversion
After inversion
Export to MODELA PLAYER
Cutting a three-dimensional object with a modeling machine
Dr. PICZA has a function for exporting data to MODELA PLAYER. MODELA PLAYER is software for cutting three-dimensional objects on the MODELA, CAMM-3, or CAMM-2, three-dimensional modeling machines made by Roland DG Corp. Dr. PICZA can output 3D data directly to MODELA PLAYER. In this example, we'll use the MODELA in combination with Dr. PICZA to make a paperweight in the shape of a leaf. The explanation assumes that you already have the MODELA installed and set up.
11
Dr.PICZA for Windows
disks: 2
1 Check the included items
AC adapter: 1
The configuration of the AC adapter varies according to regional differences in voltage. Please note that the descriptions in this manual are for the 117 V adapter.
Dr.PICZA for Mac OS
disk: 1
Do not attempt to move the table by hand.
Do not put the hands inside the unit. Doing so may result in breakdown of the unit.
NOTICE
2 Part names
Sensor
This remains inside the cover except during scanning.
Serial connector
AC adapter jack
Table
The grid on the table serves as a guide for mounting the object to scan. It does not indicate the scanning area for Dr. PICZA. The scale is in 10-mm (about 3/8 in.) units.
Clay: 1 PIX-4 User's manual: 1
Do not put hands inside.
STANDBY key
STANDBY
LED
12
3 Setting up and connection
Do not use with any power supply other than the dedicated AC adapter.
Use with any other power supply may lead to fire or electrocution.
Do not use with any electrical power supply that does not meet the ratings displayed on the AC adapter.
Use with any other power supply may lead to fire or electrocution.
Install on a stable surface.
Failure to do so may result in falling of the unit, leading to injury.
Use within a temperature range of 5 to 40°C (41 to 104°F) and within a humidity range of 35 to 80%.
Securely connect the power cord, computer I/O cable and so on so that they will not be unplugged and cause failure during operation. Doing so may lead to faulty operation or breakdown.
NOTICE
When you carry the PIX-4, use two hands to securely grip this area on the left and right sides.
Never install this unit in any of the following situations, as it could result in damage:
Places where the installation surface is unstable or not level. Places with excessive electrical noise. Places with excessive humidity or dust. Places with poor ventilation, because the PIX-4 generates considerable heat during operation. Places with excessive vibration.
13
AC adapter jack
For IBM PC or PC compatible For Macintosh
Serial connector
Use a commercially available Phillips screwdriver to tighten the screws at either end of the serial cable.
Crossover serial
cable
Included AC adapter
Printer port Modem port
Connect to either port.
Serial connector
Crossover serial cable (for Macintosh)
Screw Screw
• During scanning, the table moves forward and backward. If the mounted scan object (the three-dimensional object to be scanned) is larger than the table size, it may extend beyond the front and rear of the unit. Do not place any objects in the area.
• For the cable, use a commercially available crossover serial cable (RS-232C rating). A straight serial cable such as is commonly used to connect a modem cannot be used. For more on how to connect a serial cable for Macintosh, see "15 Specifications -- Serial Cable for Macintosh."
• Make sure the power to the computer and the PIX-4 is switched off before attempting to connect the cables.
Freeing the table
Before using the unit, remove the screw and the retainer shown in the figure. The table does not move if it remains secured in place by the retainer.
1
Attach the retainer in the orientation shown in the figure, and tighten the screws.
* The screws and retainer are necessary
when repacking the unit. Do not discard them.
2
1)
2)
Screw
Retainer
Screw
14
4 Installing the Dr.PICZA
Symbols used in the section on software
When the procedures for Windows and for the Mac OS are different, both are described. When the procedures are similar, the explana­tions use the screens for the Windows version. In such cases, the screen images may differ from those for the Mac OS version, but the procedures do not change.
Overview of Dr. PICZA
A Quick Overview of Available Functions Toolbar button
View scanned 3D data from various angles
Zoom in or out on the on-screen view of scanned data
Make settings for how scanned 3D data is displayed
Color the faces of scanned 3D data
Adjust the slant of scanned 3D data
Specify the data format and save the scanned 3D data
Launch the MODELA PLAYER
Set scanning conditions and perform scanning
Edit scanned 3D data
Displays the coordinates of the scanned object
* For details, please refer to the help screens for Dr. PICZA.
15
Installing
Dr.PICZA for Windows
Personal computer running Windows 95, Windows 98, or Windows NT 4.0 If you're using Windows 95: i486SX or better (Pentium 100 MHz recommended)
If you're using Windows 98 or Windows NT 4.0: i486DX or better (Pentium 100 MHz recom­mended)
If you're using Windows 95: 8 MB or more (10 MB or more recommended) If you're using Windows 98 or Windows NT 4.0: 16 MB or more (32 MB or more recommended)
3 MB or more of free space
Setting Up the Windows Version of the Program
Operating environment
Computer CPU
System Memory
Hard Disk
Setup
* When setting up the software under Windows NT 4.0, log on as the member of a group other than [Guest].
Hard disk : C Floppy-disk drive : A
* If your drive-name assignments differ from the ones shown at left, make the appropriate changes.
Switch on the computer and start Windows.
1
2 Insert the Dr. PICZA for Windows disk 1/2 included with the unit.
Double-click on the [My Computer] icon on screen.
3
Double-click on the [3-1/2 Floppy] icon.
4
16
Double-click on the [setup.exe] icon.5
This starts the setup program. Follow the messages to carry out setup. For MODELA PLAYER, at the screen for selecting the machine, make the setting for the Roland DG Corp.'s modeling machine you're using.
Setting Up the Mac OS Version of the Program
Operating environment
Dr.PICZA for Mac OS
A Power Macintosh, or PowerBook with a PowerPC processor. Mac OS 7.5 or higher 20 MB or more (40 MB or more recommended) 3 MB or more of free space
Computer System System Memory Hard Disk
Setup
Double-click the disk icon.3 Double-click the [Read Me] icon and read the file.
When you're finished reading, open the [File] menu and choose [Quit].
4
Turn off any virus-detection software.
1
2 Insert the Dr. PICZA for Mac OS disk in the disk drive.
Double-click the Installer icon.
5
When the Installer's start screen appears, click [Con­tinue...].
6
Choose where to install the program and click [Install]. Installation starts.
7 When installation finishes, click [Quit].8
17
5 Starting Dr. PICZA
About Help
If you're unsure how perform an operation while you're working, taking a look at Help can find the answer. If you're using Dr. PICZA for the first time, please be sure to read the Help screens. You can call up Help from the software menus.
For Dr. PICZA for Windows OS
Press the Start button and select [Dr. PICZA].
For Dr. PICZA for Mac OS
For Dr. PICZA for Windows OS For Dr. PICZA for Mac OS
18
Select the port where the cable is connected, then click [OK].
2
For Dr. PICZA for Mac OS
Press the File button and select [Preferences...].1
Click either one or the other
If Dr. PICZA selects the same communication port as AppleTalk, the scanning cannot be processed. In this case, please change the setting of Dr. PICZA so as to use another port. Or, disable the AppleTalk.
6 Selecting a communication port
From the [File] menu, click [Settings].
1
Select the port where the cable is connected, then click [OK].
2
For Dr. PICZA for Windows OS
If You're Using Windows NT 4.0
If the printer port for Windows driver and the communication port for Dr. PICZA are set to the same port, you cannot use Dr. PICZA. To perform scanning, specify an unused port for the Dr. PICZA communication port.
19
8
Load the object to be scanned on the PIX-4
The sensors for the PIX-4 are highly sensitive, and can even scan three-dimensional objects made out of clay. You can usually perform scanning if the three-dimensional object is of a composition and configuration that can retain its shape. However, the pressures that the sensors detect are from several grams to several tens of grams, so you cannot scan objects whose shape changes when touched by the sensors. (Pressure may fluctuate, depending on the composition of the object being scanned.) For instance, it may not be possible to scan something like a fuzzy stuffed animal.
Maximum scanning area of the PIX-4
The maximum scanning area is shown in the figure.
The grid on the table serves as a guide for mounting the object to scan. It does not indicate the scanning area for Dr. PICZA. The scale is in 10-mm (3/8 in.) units.
152.4 mm (6 in.)
Maximum scanning area
101.6 mm (4 in.)
60.5 mm (2-3/8 in.)
Upper surface
Front surface
Table surface
* This space cannot be scanned.
10 mm (3/8 in.)
7 Powering ON
Press the STANDBY key. The STANDBY LED lights up.
1 The unit performs its initialization routine, then stops.
The sound that occurs during initial operation is not abnormal.
* When the unit is in its initialized state immediately
switching on the power, an error may be displayed if some object touches the sensor. (When an error has occurred, the STANDBY LED intermittently flashes twice.) If this happens, switch off the power, remove the object touching the sensor, then switch the power back on.
2
Before switching on the power to the PIX-4, turn on the computer.
NOTICE
20
2) Use the spacers to adjust the height so that the portion you want to scan lies within the scanning area.
Scanning cannot be performed in the area up to 10 mm (3/8 in.) above the table surface. Mount so that the portion you want to scan is at a height of 10 mm (3/8 in.) or more above the table surface. If the height is still not enough even when using the included spacers, place a book or the like of suitable thickness underneath. The maximum load weight of the table is 500 g (1.1 lb.).
Maximum scanning area
Table surface
Clay
Scannable portion (Scan object)
10 mm (3/8 in.)
60.5 mm
(2-3/8 in.)
Load the object to be scanned on the PIX-4
When securing the scan object in place, be sure to use the included clay or adhesive sheet. Do not use double-sided tape or other strongly adhesive materials. Such materials may cause the table surface to peel.
During scanning, the table moves forward and backward. Mount the object to be scanned so that it does not touch the inner wall of the PIX-4.
NOTICE
1) Decide on which surface of the scan object to scan.
When mounting the object, secure it in place with the surface to scan facing up.
Scan face Scan face
21
3) Secure the scan object in place.
Make a base on the table using clay.
1
Press the scan object into the clay to hold it in place.
2
Clay
Table
Scan object
Clay
Table
22
9 Starting scanning
About scanning conditions and the scanning area
For information about the setting items for Dr. PICZA, refer to the figures below. The grid on the table serves as a guide for mounting the object to scan. It does not indicate the scanning area for Dr. PICZA. The scale is in 10-mm (3/8 in.) units.
Do not place hands near the main unit while in operation.
Doing so may result in injury. Doing so may lead to faulty operation or breakdown.
Setting scanning conditions and starting scanning
Y SCAN PITCH
(Spacing of adjacent scan points along the Y axis)
Scanning Area
: Scan path (Draft scanning)
: Scan points
Scanning area
Maximum scanning area
Maximum scanning area
The explanations here and after are based on samples like those shown in the figures.
(Height of the scanning area's bottom plane)
Z BOTTOM
Table surface
Scan object
Z Upper
Limit
X SCAN PITCH
(Spacing of adjacent scan points along the X axis)
23
Click on the Dr. PICZA. The Controller window opens.
When Dr. PICZA is started, the Controller window is already open.
1
2
2
Make the settings for scanning resolution, the minimum height of the surface to be scanned, and the scanning quality.
Make the settings for X scan pitch and Y scan pitch. The setting in this example is for 0.50 mm (0.020 in.).
2
Make the setting for Z bottom. The setting in this example is for 13 mm (0.512 in.).
3
Make the selection for scanning quality. Here, click [Fine] to activate this setting.
4
5
Here, click [Smart Scan] to activate the setting. When the [Smart Scan] setting is on, clicking [Scan] makes the PIX-4 automatically restrict the scanning area (on the X-Y plane only) before scanning is performed. To specify the scanning area, turn off [Smart Scan] and refer to "Setting the scanning area" to make the desired settings.
6
Click [SCAN] . Scanning starts. (During scanning, the sensor may emit a transmission sound, but this is normal.)
3
6
5
4
For Dr. PICZA for Mac OS
Open the [File] menu and choose [New].
()
For detailed description of the available Controller buttons, please refer to the help screens for Dr. PICZA.
Use the following examples as a guide to determine the amount of computer memory required to perform scanning. * The figures shown below are the amounts used by Dr. PICZA alone. They do not take into account the amounts used by the operating
system or other programs.
Example: Required memory when scanning a 100 mm x 100 mm (3-15/16 in. x 3-15/16 in.) area
- Scanning at a pitch of 0.05 mm x 0.05 mm (0.002 in. x 0.002 in.) : Approx. 2 GB
- Scanning at a pitch of 0.1 mm x 0.1 mm (0.004 in. x 0.004 in.) : Approx. 500 MB
- Scanning at a pitch of 0.5 mm x 0.5 mm (0.020 in. x 0.020 in.) : Approx. 20 MB
If You're Using Windows NT 4.0
If the printer port for Windows driver and the communication port for Dr. PICZA are set to the same port, you cannot use Dr. PICZA. To perform scanning, specify an unused port for the Dr. PICZA communication port.
24
6
Setting the scanning area
If you wish to limit the scanning area, such as in cases where you wish to scan only a portion of an object, make the settings as described below.
Click [Scanning Area] in the Controller window. The [Scanning Area] dialog box appears.1
Make the settings for the scanning area. Make the settings to match the location where the scan object is secured in place. Either of the following two methods can be used to make the settings.
- Use the mouse to move the blue frame on screen. - Enter the numerical values for the upper-right and lower-left points. The size of the on-screen scanning area (shown in blue) changes to match the values that are entered.
2
After determining the scanning area, click [OK].
5
• For the scanning area and Z upper limit, please refer to "About scanning conditions and the scanning area".
• For details about the buttons on the scanning-region setting screen, please refer to the help screens for Dr. PICZA.
Check the scanning conditions in the Controller window one more time, then click [SCAN] . Scanning starts. (During scanning, the sensor may emit a transmission sound, but this is normal.)
Click [Begin Area Test]. The sensor moves to a position above an outer point on the scanning area that has been set. Make sure the scan object that has been secured in place lies within the area.
3
Click [Z Upper Limit].
The cursor
is displayed on the Z upper-limit setting on screen.
Specify the highest position of the scan object. Clicking [Apply] or double-clicking on the target lowers the sensors to the target's center position. If the target is displaced, redo the settings.
* Set the Z upper limit to the highest position on the object to be scanned.
During scanning, if the sensor detects a position higher than the Z upper-limit setting, the setting is cleared and scanning continues with the greatest scan height of Dr. PICZA as the Z upper limit.
4
4
3
2
4
4
5
25
Cancels scanning/Pauses scanning
Cancels scanning. Any data scanned before being canceled remains in memory.
Rescanning a particular portion
After you’ve scanned an object, you can rescan a particular portion of the object. After performing coarse scanning for the entire object, respecifying only an included portion and performing fine scanning can shorten the scanning time. However, if the scan object has been moved or removed from the table, or if the power to the PIX-4 has been switched off and back on, then you cannot scan the same portion.
Scanning pauses and the sensor moves to the VIEW position (the inner-right area). Click [VIEW] again to resume scanning.
Click , and from the scanning data shown on the screen, select a portion to rescan.
You can specify a number of noncontinuous portions.
1
Click on the Dr. PICZA. The Control­ler window opens.
Specify area for rescanning
Make the setting for scanning conditions.
3
Click [SCAN]. Rescanning of the specified portion starts.
4
Results of rescanning
26
10 Saving scanned data
Click and choose [Save] . The [Save As] dialog box appears.
1
For information on how to save a file, please refer to the help screens for Dr. PICZA.
Choose the desired location for saving the file, enter a file name, and click [SAVE]. The extension ".pix" is appended to the file name.
2
11 Powering OFF
Press the STANDBY key. The STANDBY LED goes out.
When not in use for extended periods, unplug the AC adapter from the electrical outlet.
Failure to do so may result in danger of shock, electrocution, or fire due to deterioration of the electrical insulation.
Edit the scanned data
The shape of an object can be edited. It is possible to vary the height, adjust the slant, or perform concave/convex inversion (height inversion) for a desired surface. You can use the toolbar button or select [Edit] on the menu bar. Please refer to the help screens for Dr. PICZA for detailed explanations of the various functions that are available. Be sure to save the scanned data before starting to edit. When you're done editing, be sure to save your file.
When not in use
- Remove the scan object from the table.
- Remove any clay from table, and store the clay so that it will not dry out.
- Unplug the AC adapter from the electrical outlet.
For Dr. PICZA for Mac OS
Click and choose [Save]. The dialog appears.
()
27
12 Ending Dr. PICZA
Crick the button.
13 Items that may not be copied
Unauthorized reproduction of a copyrighted item for any purpose other than personal use may be a violation of copyright. Roland DG Corp. will not be responsible for any violation of third-party copyright by any article made through use of this product.
14 What to do if...
If you want to completely stop the operation of the PIX-4, detach the AC adapter from AC outlet.
The PIX-4 doesn't operate
Check the following.
- Is the STANDBY key on (with the STANDBY LED lit up)?
- Are the settings for the computer and software correct?
- Are the cable connected correctly?
- Have the retaining screws and the retainer for the table been removed? (Refer to "3 Setting up and connec­tion".)
The STANDBY LEDs repeatedly flashes once
This indicates a communications error. Switch off the power and check the following.
- Are the communications port settings made for Dr. PICZA correct?
- Are the connections for the AC adapter and the cable connecting the unit to the computer secure?
- Are the AC adapter and the cable connecting the unit to the computer free of any internal broken wires?
- Is the operation of the computer correct?
- Was the power to the computer switched on before the PIX-4 was turned on? (Be sure to power up the computer first, then switch on the power to the PIX-4.)
- Was the computer restarted? When the computer has been restarted, switch the power to the PIX-4 off, wait a few seconds, then switch it back on.
The STANDBY LEDs repeatedly flashes twice
Something touched the sensor during initial operation immediately after switching on the power, or a hardware error occurred. If there is an obstruction, then switch off the power, remove the obstruction, and switch the power back on. If there was a hardware error, then switch the power off and back on and repeat the same operation. If the same error display occurs, consult your authorized Roland dealer or service center.
Pressing the ST ANDBY key does not switch off the power.
Unplug the AC adapter from the unit.
The tip of the sensor was inadvertently bent
Please contact your authorized Roland DG Corp. dealer or service center.
28
15 Specifications
Main unit specifications
Max. scanning area : 152.4 mm (6 in.) [X] x 101.6 mm (4 in.) [Y] x 60.5 mm (2-3/8 in.) [Z] Max. table load weight : 500 g (1.1 lb.) Sensor : Roland Active Piezo Sensor (R.A.P.S.)
Probe length 64 mm (2-1/2
in.
), tip bulb diameter 0.08 mm
(0.00315 in.)
Scanning method : Contacting, mesh-point height-sensing Scanning pitch : X/Y-axis directions -- 0.05 to 5.00 mm (0.002
in.
to 0.20
in.
) (settable in steps of 0.05 mm (0.002
in.
))
(Dr. PICZA) Z-axis direction -- 0.025 mm (0.000984
in.
)
Scanning speed : X/Y-axis -- 30 mm/sec. (1-1/8 in./sec.) Z-axis -- 9 mm/sec. (5/16 in./sec.) Exportable file formats : DXF, VRML, STL, 3DMF, Grayscale, PICT (for Mac OS), BMP (for Windows), and Vertex Interface : Serial (RS-232C) Control keys : STANDBY key LED : STANDBY LED Power consumption : Exclusive AC adapter (DC+12V 1.5 A) Acoustic noise level : Standby mode: under 31 dB (A)
Scanning mode: under 41 dB (A) (According to ISO 7779)
External dimensions : 313 mm (W) x 304 mm (D) x 276 mm (H) (12-3/8 in. (W) x 12 in. (D)) x 10-7/8 in. (H)) Weight (unit only) : 4.9 kg (10.8 lb.) Operation temperature : 5—40°C (41—104°F) Operation humidity : 35—80 % (no condensation) Accessories :
Dr.PICZA for Windows disks: 2, Dr.PICZA for Mac OS disk: 1, AC adapter: 1, clay: 1, PIX-4 user's manual: 1
Interface Specification
[Serial]
Standard : RS-232C specifications Transmission method : Asynchronous, duplex data transmission Transmission speed : 9600 bps Parity Check : None Data Bits : 8 bits (fixed) Stop Bits : 1 bits (fixed) Handshake : Hardwire
Serial connector (RS-232C)
Serial Cable for Macintosh
Prepare a crossover cable with the following specifications to connect the Macintosh and the PIX-4.
Crossover serial cable
Mini-DIN 8-pin male connector - D-sub 25-pin male connector Apple crossover cable (JCRC01 compliant)
Mini-Din
8P
GND
D-sub25P
25P
GND
2 3 4 5
2 3 4 5 6 7 8
20
NC NC NC NC NC
DTR
NC NC NC NC NC NC
NC NC NC NC NC NC
SG DSR CTS
RTS RXD TXD
FG
Terminal
number
25 24 23 22 21 20 19 18 17 16 15 14
13 12 11 10
9 8 7 6 5 4 3 2 1
Pin connection
Signal
number
Signal
number
R2-990707
Please read this agreement carefully before opening the sealed
package or the sealed disk package
Roland License Agreement
Roland DG Corporation ("Roland") grants you a non-assignable and non-exclusive right to use the COMPUTER PROGRAMS in this package ("Software") under this agreement with the following terms and conditions.
1. Coming into Force This agreement comes into force when you purchase and open the sealed package
or sealed disk package. The effective date of this agreement is the date when you open the sealed package or sealed disk package.
2. Property Copyright and property of this Software, logo, name, manual and all literature
for this Software belong to Roland and its licenser.
The followings are prohibited :
(1) Unauthorized copying the Software or any of its support file, program module
or literature.
(2) Reverse engineering, disassembling, decompiling or any other attempt to
discover the source code of the Software.
3. Bounds of License Roland does not grant you to sub-license, rent, assign or transfer the right granted
under this agreement nor the Software itself (including the accompanying items) to any third party. You may not provide use of the Software through time-sharing service and/or network system to any third party who is not individually licensed to use this Software.
You may use the Software by one person with using a single computer in which the Software is installed.
4. Reproduction Y ou may make one copy of the Software only for back-up purpose. The property
of the copied Software belongs to Roland. You may install the Software into the hard disk of a single computer.
5. Cancellation Roland retains the right to terminate this agreement without notice immediately
when any of followings occurs : (1) When you violate any article of this agreement. (2) When you make any serious breach of faith regarding this agreement.
6. Limitations on Liability Roland may change the specifications of this Software or its material without
notice.
Roland shall not be liable for any damage that may caused by the use of the Software or by exercise of the right licensed by this agreement.
7. Governing Law This agreement is governed by the laws of Japan, and the parties shall submit to
the exclusive jurisdiction of the Japanese Court.
Opening the sealed package or sealed disk package implies your acceptance of the terms and conditions of this agreement. If you do NOT accept this agreement, retain the package UNOPENED. (This product is just one of included items. Please be aware that any amount of the purchase price will not be refunded for return of this product as a single item, regardless of whether the package is opened or unopened.) The enclosed Roland product is a single user version.
Loading...