Before using this unit, carefully read the sections entitled: “IMPORTANT SAFETY
INSTRUCTIONS” (Owner’s manual p. 2), “USING THE UNIT SAFELY” (Owner’s manual p.
3), and “IMPORTANT NOTES” (Owner’s manual p. 5). These sections provide important
information concerning the proper operation of the unit. Additionally, in order to feel
assured that you have gained a good grasp of every feature provided by your new unit,
Owner’s manual should be read in its entirety. The manual should be saved and kept on
hand as a convenient reference.
No part of this publication may be reproduced in any form
without the written permission of ROLAND CORPORATION.
http://www.roland.co.jp/
Page 2
2
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
ATTENTION: RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK).
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightning flash with arrowhead symbol, within an
equilateral triangle, is intended to alert the user to the
presence of uninsulated “dangerous voltage” within the
product’s enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is
intended to alert the user to the presence of important
operating and maintenance (servicing) instructions in the
literature accompanying the product.
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS.
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
WARNING - When using electric products, basic precautions should always be followed, including the following:
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any of the ventilation openings. Install in
accordance with the manufacturers instructions.
8. Do not install near any heat sources such as radiators,
heat registers, stoves, or other apparatus (including
amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades with
one wider than the other. A grounding type plug has two
blades and a third grounding prong. The wide blade or the
third prong are provided for your safety. When the provided
plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched
particularly at plugs, convenience receptacles, and the
point where they exit from the apparatus.
11. Only use attachments/accessories specified by the
manufacturer.
12. Never use with a cart, stand, tripod, bracket,
or table except as specified by the
manufacturer, or sold with the apparatus.
When a cart is used, use caution when
moving the cart/apparatus combination to
avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when
unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing
is required when the apparatus has been damaged in any
way, such as power-supply cord or plug is damaged, liquid
has been spilled or objects have fallen into the apparatus,
the apparatus has been exposed to rain or moisture, does
not operate normally, or has been dropped.
For the U.K.
WARNING:
IMPORTANT:
As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured markings identifying
the terminals in your plug, proceed as follows:
The wire which is coloured GREEN-AND-YELLOW must be connected to the terminal in the plug which is marked by the
letter E or by the safety earth symbol or coloured GREEN or GREEN-AND-YELLOW.
The wire which is coloured BLUE must be connected to the terminal which is marked with the letter N or coloured BLACK.
The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured RED.
204
THIS APPARATUS MUST BE EARTHED
THE WIRES IN THIS MAINS LEAD ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE.
GREEN-AND-YELLOW: EARTH, BLUE: NEUTRAL, BROWN: LIVE
* Microsoft and Windows are registered trademarks of Microsoft Corporation.
206c
* Windows® 98 is known officially as: “Microsoft® Windows® 98 operating system.”
206f
* Windows® 2000 is known officially as: “Microsoft® Windows® 2000 operating system.”
206g
* Windows® Me is known officially as: “Microsoft® Windows® Millennium Edition operating system.”
206h
* Windows® XP is known officially as: “Microsoft® Windows® XP operating system.”
207
* Apple and Macintosh are registered trademark of Apple Computer, Inc.
209
* MacOS is a trademark of Apple Computer, Inc.
233+
* VST and ASIO are trademark of Steinberg Media Technologies AG.
220
* All product names mentioned in this document are trademarks or registered trademarks of their respective owners.
Page 3
USING THE UNIT SAFELY
Used for instructions intended to alert
the user to the risk of death or severe
injury should the unit be used
improperly.
Used for instructions intended to alert
the user to the risk of injury or material
damage should the unit be used
improperly.
* Material damage refers to damage or
other adverse effects caused with
respect to the home and all its
furnishings, as well to domestic
animals or pets.
001
• Before using this unit, make sure to read the
instructions below, and the Owner’s Manual.
• Do not attempt to repair the unit, or replace parts
within it (except when this manual provides
specific instructions directing you to do so). Refer
all servicing to your retailer, the nearest Roland
Service Center, or an authorized Roland
distributor, as listed on the “Information” page.
• Make sure you always have the unit placed so it is
level and sure to remain stable. Never place it on
stands that could wobble, or on inclined surfaces.
The symbol alerts the user to important instructions
or warnings.The specific meaning of the symbol is
determined by the design contained within the
triangle. In the case of the symbol at left, it is used for
general cautions, warnings, or alerts to danger.
The symbol alerts the user to items that must never
be carried out (are forbidden). The specific thing that
must not be done is indicated by the design contained
within the circle. In the case of the symbol at left, it
means that the unit must never be disassembled.
The ● symbol alerts the user to things that must be
carried out. The specific thing that must be done is
indicated by the design contained within the circle. In
the case of the symbol at left, it means that the powercord plug must be unplugged from the outlet.
009
• Do not excessively twist or bend the power cord,
nor place heavy objects on it. Doing so can
damage the cord, producing severed elements and
short circuits. Damaged cords are fire and shock
hazards!
• This unit, either alone or in combination with an
amplifier and headphones or speakers, may be
capable of producing sound levels that could
cause permanent hearing loss. Do not operate for
a long period of time at a high volume level, or at
a level that is uncomfortable. If you experience
any hearing loss or ringing in the ears, you should
immediately stop using the unit, and consult an
audiologist.
• Immediately turn the power off, remove the
power cord from the outlet, and request servicing
by your retailer, the nearest Roland Service
Center, or an authorized Roland distributor, as
listed on the “Information” page when:
• In households with small children, an adult
should provide supervision until the child is
capable of following all the rules essential for the
safe operation of the unit.
• Do not force the unit’s power-supply cord to share
an outlet with an unreasonable number of other
devices. Be especially careful when using
extension cords—the total power used by all
devices you have connected to the extension
cord’s outlet must never exceed the power rating
(watts/amperes) for the extension cord. Excessive
loads can cause the insulation on the cord to heat
up and eventually melt through.
• Before using the unit in a foreign country, consult
with your retailer, the nearest Roland Service
Center, or an authorized Roland distributor, as
listed on the “Information” page.
• DO NOT play a CD-ROM disc on a conventional
audio CD player. The resulting sound may be of a
level that could cause permanent hearing loss.
Damage to speakers or other system components
may result.
• Any accumulation of dust between the power
plug and the power outlet can result in poor
insulation and lead to fire. Periodically wipe away
such dust with a dry cloth. Also, disconnect the
power plug from the power outlet whenever the
unit is to remain unused for an extended period of
time.
• Should you remove rubber feet or screws of rack
mount angles, make sure to put them in a safe
place out of children's reach, so there is no chance
of them being swallowed accidentally.
In addition to the items listed under “IMPORTANT
SAFETY INSTRUCTIONS” and “USING THE UNIT
SAFELY” on p. 2 and p. 3, please read and observe the
following:
Power Supply
301
• Do not use this unit on the same power circuit with any
device that will generate line noise (such as an electric
motor or variable lighting system).
307
• Before connecting this unit to other devices, turn off the
power to all units. This will help prevent malfunctions
and/or damage to speakers or other devices.
Placement
351
• Using the unit near power amplifiers (or other equipment
containing large power transformers) may induce hum.
To alleviate the problem, change the orientation of this
unit; or move it farther away from the source of interference.
352a
• This device may interfere with radio and television
reception. Do not use this device in the vicinity of such
receivers.
352b
• Noise may be produced if wireless communications
devices, such as cell phones, are operated in the vicinity of
this unit. Such noise could occur when receiving or initiating a call, or while conversing. Should you experience
such problems, you should relocate such wireless devices
so they are at a greater distance from this unit, or switch
them off.
355b
• When moved from one location to another where the
temperature and/or humidity is very different, water
droplets (condensation) may form inside the unit. Damage
or malfunction may result if you attempt to use the unit in
this condition. Therefore, before using the unit, you must
allow it to stand for several hours, until the condensation
has completely evaporated.
Maintenance
401a
• For everyday cleaning wipe the unit with a soft, dry cloth
or one that has been slightly dampened with water. To
remove stubborn dirt, use a cloth impregnated with a
mild, non-abrasive detergent. Afterwards, be sure to wipe
the unit thoroughly with a soft, dry cloth.
402
• Never use benzine, thinners, alcohol or solvents of any
kind, to avoid the possibility of discoloration and/or
deformation.
Additional Precautions
553
• Use a reasonable amount of care when using the unit’s
buttons, sliders, or other controls; and when using its jacks
and connectors. Rough handling can lead to malfunctions.
556
• When connecting / disconnecting all cables, grasp the
connector itself—never pull on the cable. This way you
will avoid causing shorts, or damage to the cable’s
internal elements.
557
•A small amount of heat will radiate from the unit during
normal operation.
558a
• To avoid disturbing your neighbors, try to keep the unit’s
volume at reasonable levels. You may prefer to use
headphones, so you do not need to be concerned about
those around you (especially when it is late at night).
559a
• When you need to transport the unit, package it in the box
(including padding) that it came in, if possible. Otherwise,
you will need to use equivalent packaging materials.
562
• Use a cable from Roland to make the connection. If using
some other make of connection cable, please note the
following precautions.
• Some connection cables contain resistors. Do not use
cables that incorporate resistors for connecting to this
unit. The use of such cables can cause the sound level
to be extremely low, or impossible to hear. For information on cable specifications, contact the manufacturer of the cable.
Handling CD-ROMs
801
• Avoid touching or scratching the shiny underside
(encoded surface) of the disc. Damaged or dirty CD-ROM
discs may not be read properly. Keep your discs clean
using a commercially available CD cleaner.
Copyright
852a’
• As this product is designed as professional equipment,
this unit can perform recording without being subject to
the restrictions of the Serial Copy Management System
(SCMS) even in case of exchanging audio signals through
a digital connection with an external instrument. This is
because the unit is intended solely for musical production,
and is designed not to be subject to restrictions as long as
it is used to record works (such as your own compositions) that do not infringe on the copyrights of others.
(SCMS is a feature that prohibits second-generation and
later copying through a digital connection. It is built into
MD recorders and other consumer digital-audio
equipment as a copyright-protection feature.)
853
• Do not use this unit for purposes that could infringe on a
copyright held by a third party. We assume no responsibility whatsoever with regard to any infringements of
third-party copyrights arising through your use of this
unit.
5
Page 6
Contents
USING THE UNIT SAFELY......................................................................3
IMPORTANT NOTES ...............................................................................5
Main Features.............................................................................................................................................. 7
Standard Driver Mode .................................................................................................................13
Installing the Drivers ...............................................................................................................................14
Digital Connections..................................................................................................................................16
Other Points...............................................................................................................................................17
Other Features ......................................................................................18
Initializing the Settings
---Restoring the M-1000 to Its Original Factory Conditions............................................................... 18
Changing the Signal Path for the Analog Output (MIX OUT)
- If the audio in the inputs is doubled in the output when using the USB connection -............... 18
About SCMS..............................................................................................................................................20
Disclaimer of liability...............................................................................................................................20
About the License Agreement................................................................................................................20
• Features four pairs of stereo (eight-channels) digital audio input plus one
pair of stereo (two-channels) analog audio input.
• Connects to computers via USB for input and output of digital audio signals.
• Each digital audio signal input is equipped with a sample rate converter,
thus allowing you to mix even inputs with different sampling frequencies
and phases.
Accessories
The following additional items are shipped with the M-1000. Please take a moment
to confirm that all of the following items have been included in the box.
• Owner's Manual (this volume)
• “Functions and Operations of Each Section” chart
• CD-ROM (Driver)
• USB cable
• Rubber feet (4)
• Power cable
■
Basic Operation
Preparation
Attaching the rubber feet
If necessary, attach the rubber feet on the
bottom panel as shown in the figure.
Setup
Mount the M-1000 in rack mount, set it on a table or desk, or in another suitable
location.
* If the M-1000 is placed directly above a power amp, the heat generated by the amp may
adversely affect the M-1000.
Connecting the Power Source
Use the included power cable to
connect the unit with a power source.
M-1000
rear panel
The pin assignment for the XLR type connectors
* The pin assignment for the XLR type connectors is as shown below.
Before making any connections, make sure that this pin assignment
is compatible with that of all your other devices.
power cable
7
Page 8
Introduction
Turning On the Power
* Once the connections have been completed (p. 7, p. 9, p. 10), turn on power to your
various devices in the order specified. By turning on devices in the wrong order, you risk
causing malfunction and/or damage to speakers and other devices.
■
1.
2.
■
1.
2.
Turn down the volume completely on all devices.
Press the POWER switch on the M-1000's front panel to turn on the power.
If the M-1000 is operating properly, the indicators should show the current
settings. If set to the default factory settings, the [INT] and [44.1kHz]
indicators light if no input or output device is connected. In other cases,
indicators show the current settings or connections.
* This unit is equipped with a protection circuit. A brief interval of a few seconds is
required after power up before the unit will operate normally.
Turning Off the Power
Turn down the volume completely on all devices.
Press the POWER switch on the M-1000's front panel to turn off the power.
Functions and Operation of
“Examples of Use” (p. 9)
Each Section
For a look at the features found in each section and how to use them,
refer to the A3-size chart “Functions and Operations of Each Section.”
8
Page 9
Examples of Use
* To prevent malfunction and/or damage to speakers or other devices, always turn down
the volume, and turn off the power on all devices before making any connections.
Mixing Analog and Digital Inputs
As shown in the following figure, you can connect synthesizers and audio sources,
and then mix these inputs.
* For instructions on what to do in each section, refer to the separate “Functions and
Operations of Each Section” chart.
Analog Input
Try inputting signals with the
ANALOG INPUT SENS (sensitivity)
switch set to [-10 dB].
If the PEAK indicator lights, switch
this to [+4 dB].
Digital Input
If using one digital input, set the
DIGITAL INPUT SELECT switch to
match the input (coaxial or optical)
connector being used.
Confirm that the LOCK indicator for
the input being used is lit.
Adjust the volume with the LEVEL
Amp/Digital Recorder
The sampling frequency of the
connected digital recorder is
synchronized to the M-1000.
Adjust the output volume with the
LEVEL (inner) knob.
Adjust the left-right volume balance
with the BALANCE (outer) knob.
Adjust the volume
to a comfortable level.
Headphones
DIGITAL IN
Digital Recorder
LINE IN
Amp
DIGITAL OUT
Digital
DIGITAL OUT
Digital
MASTER
OUT
Analog
9
Page 10
Examples of Use
b
Using the M-1000 with a Computer Connected Via USB
You can use the M-1000 with computers by connecting as shown in the following figure.
• Mixing the input from digital inputs 1--3 and the analog input with sounds
played back from the computer
• Mixing the input from digital inputs 1--3 and the analog input, and recording
this to the computer
• Recording the mixed input from digital inputs 1--3 and the analog input to the
computer while playing back previously recorded sounds with the computer.
To record or play audio on computers, application software is necessary. (The
application software pre-installed to MacOS or Windows can be used for such purpose.)
* For instructions on what to do in each section, refer to the separate “Functions and
Operations of Each Section” chart.
The M-1000 mix output can be
sent to the USB port, and then
the USB port can return this
signal along with its own
audio as the USB input to the
M-1000. However, signals
played back with the computer
cannot be returned and used
y the computer via USB
(computer → USB → M-1000
→ USB → computer).
Analog Input
Try inputting signals with the
ANALOG INPUT SENS (sensitivity)
switch set to [-10 dB].
If the PEAK indicator lights, switch
this to [+4 dB].
Inputting from the Computer
The LOCK indicator lights up when the M-1000 is
connected to a computer with a USB cable.
Adjust the volume of the sound from the computer.
Digital Input
If using one digital input, set the
DIGITAL INPUT SELECT switch to
match the input (coaxial or optical)
connector being used.
Confirm that the LOCK indicator for
the input being used is lit.
Adjust the volume with the LEVEL
knob.
Four digital inputs accept sounds from
computers.
Outputting to the
Computer (and MASTER
Output)
Adjust the volume level input to the
computer with the LEVEL (inner)
knob.
Adjust the left-right balance of the
sound input to the computer with the
BALANCE (outer) knob.
Adjust the volume
to a comfortable level.
Headphones
DIGITAL OUT
MASTER
Digital
USB
When connecting with USB,
you cannot input signals
Computer
Install the USB audio driver
and make the appropriate settings.
through input 4.
DIGITAL OUT
Digital
10
OUT
Analog
Page 11
Installing the USB Audio Driver
To connect a computer via USB, you first need to install the USB audio driver. Read
the section “Installing the Drivers” (p. 14), then perform the installation as
instructed. For better sound, we strongly recommend using the M-1000 in
“Advanced Mode” (p. 12).
■ Matching the Sampling Frequency
When exchanging audio signals between the M-1000 and a computer via a USB
connection, set both the software and the M-1000 to the same sampling frequency.
Although there are applications capable of exchanging audio signals with differing
sampling frequencies, this may reduce the sound quality.
■ Procedure for Changing the Settings
You need to switch off the M-1000, then turn it on again after you've changed the
driver or sampling frequency settings when the M-1000 is connected to a computer
via USB.
Examples of Use
■
1.Quit all applications that make use of USB audio.
2.Press the USB driver select button/sampling frequency select buttons a
number of times until the desired indicators flash (reserved status).
3.Turn off the M-1000, then turn it on again.
4.Start up your application or applications.
■ Indicator Status and Settings Status
Lit
Off
Standard Driver Mode
44.1 kHz
Standard Driver Mode
48 kHz
Advanced Mode
48 kHz
Advanced Mode
96 kHz
Input from Computer
The flashing light indicates
the “reserved” setting;
when the M-1000 is turned
off, then on again, that
setting is enabled, and the
indicator then remains lit.
Advanced Mode
44.1 kHz
Advanced Mode
96 kHz
Output to Computer
11
Page 12
USB Audio
If using the M-1000 with a computer connected, you will need to install the USB
audio driver on the computer.
* For latest information about driver etc., please refer to Roland web site.
http://www.roland.co.jp/
■ What is a Driver?
Drivers are software programs that allow data to be
exchanged between computer applications and the
M-1000 when the M-1000 is connected to the
computer with a USB cable.
The driver transmits data from applications to the
M-1000 and also relays data from the M-1000 back to the applications.
■ Types of Drivers
The following chart shows the drivers that can be used according to your operating
system (such as Windows XP or Mac OS).
application
software
driver
computer
USB:
Universal Serial Bus
USB cable
M-1000
WindowsXP/2000
WindowsMe/98
MacOS
M-1000 Special WDM Driver
M-1000 Special MME Driver
Windows Standard Driver
M-1000 Special Driver
Windows Standard Driver
M-1000 Special Driver
(under MacOS 8.6: not supported)
MacOS Standard Driver
(under MacOS 9.0.4: not supported)
cc
ADVANCED
44.1kHz/48kHz/96kHz:fromPC/96kHz:toPC
cc
ADVANCED
44.1kHz/48kHz/96kHz:fromPC/96kHz:toPC
44.1kHz/48kHz
cc
cc
ADVANCED
44.1kHz/48kHz/96kHz:fromPC/96kHz:toPC
cc
44.1kHz/48kHz
cc
ADVANCED
44.1kHz/48kHz/96kHz:fromPC/96kHz:toPC
cc
44.1kHz/48kHz
Advanced Mode and Standard Driver Mode
The M-1000 features two operational modes, Advanced mode and Standard Driver
mode, each of which uses different drivers.
The special driver supports
ASIO.
■ Advanced Mode
This mode is operational when the [ADVANCED] USB indicator is lit. Using the
special drivers provided on the M-1000 Driver CD-ROM, you can input and output
high-quality audio data with great stability in timing.
In Advanced mode, audio signals are exchanged between the M-1000 and the
computer using 24-bit resolution, with sampling frequencies of 44.1 kHz, 48 kHz,
and 96 kHz supported. Set the M-1000 to Advanced mode when using software
capable of handling input and output of high-quality audio, including programs by
Cakewalk, Cool Edit, and other 24-bit compatible software, and applications that
support ASIO, such as Cubase VST, Logic Audio, SingerSongWriter, and Metro.
You cannot play back audio data (audio CDs, alert sounds, etc.) from Macintosh's
Sound Manager in Advanced mode.
12
ASIO:
Steinberg Audio Stream In/
Out Interface
Page 13
When Using Windows XP/2000 (WDM Driver/MME Driver)
The M-1000 Driver CD-ROM includes two different drivers for use with Windows
XP and Windows 2000, the WDM driver and the MME driver.
You cannot have both installed; select one according to the software you are using.
WDM Driver
Use this driver if you have SONAR or a similar application set to WDM Driver
mode. This will allow you to obtain very good audio performance.
* 24-bit resolution is not available with Cool Edit, Media Player, and other applications
that have no WDM Driver mode.
MME Driver
Cool Edit and similar programs that have no WDM Driver mode cannot be used
with 24-bit resolution.
* The MME driver cannot be used with SONAR or similar applications while in WDM
Driver mode.
You cannot have both the WDM Driver and MME Driver installed at the
same time. Select one, then install that driver. If after installing one of the
drivers you want to change it, always be sure to delete the installed driver
before installing the new driver.
→ “Deleting the Special Drivers (Uninstall)” (p. 15)
USB Audio
WDM:
Win32 Driver Model
MME:
Microsoft Multimedia
Extensions
■ Standard Driver Mode
This mode is operational when the [ADVANCED] USB indicator is off.
This mode uses the standard USB drivers included with Windows and Macintosh.
In Standard Driver mode, audio signals exchanged between the M-1000 and the
computer feature 16-bit resolution, with sampling frequencies of 44.1 kHz and 48
kHz supported. Set the M-1000 to this mode when using applications in which audio
CDs are played back with the computer's built-in CD-ROM drive, that involve the
use software synthesizers included with Windows and Macintosh, or that utilize
functions specific to the Windows or Macintosh systems themselves.
* Drivers included with Windows and Macintosh do not support ASIO.
* The use of MacOS under MacOS 9.0.4 is not supported (standard driver mode).
Using the M-1000 After Switching Between Advanced Mode and
Standard Driver Mode
If you have both a special driver and the standard drivers installed, you
can then use the M-1000's USB driver select button (the CLOCK SOURCE
select button) to switch between Advanced mode and Standard Driver
mode.
* To enable the setting, quit all applications using the M-1000, including the
sequencer software, then turn the M-1000's power off, then on again.
→ “Procedure for Changing the Settings” (p. 11)
13
Page 14
USB Audio
Installing the Drivers
■ Installation Overview
Although you can install the necessary drivers separately, to avoid the complications
involved with repeating installation and switching settings, we recommend starting
out by installing both the standard and special drivers.
The suggested procedure is described below.
* In case you are not familiar with software installation, please refer to the document on the
CD-ROM included with the M-1000 for more detailed instruction.
Windows
for standard driver: CD-ROM →
for special driver:CD-ROM →
you are using →(“WDM”/”MME”→) “ReadMe_E.htm”
Macintosh
for special driver:CD-ROM →
English” folder → “ReadMe_E.htm”
“
for standard driver: CD-ROM →“WinGenericDriver_E.htm”
“WinGenericDriver_E.htm”“Driver” folder → operating system version
“Driver” folder → “ReadMe” folder →
“WDM Driver” (p. 13)
“MME Driver” (p. 13)
With Windows
1.With the M-1000 disconnected, start up your computer.
If the setting is not default factory setting
2.Initialize the M-1000.
3.Turn the M-1000 off temporarily.
4.Connect the M-1000 and the computer with a USB cable.
5.Turn on the M-1000.
6.Follow the instructions displayed to install the standard drivers. The M-
1000's USB indicator lights.
The instructions are not displayed if the drivers have already been installed; in this case, proceed to step 8.
7.Re-boot the computer.
8.Press the CLOCK SOURCE button to switch the M-1000 to Advanced mode
(the light flashes).
9.Turn off the M-1000 (do not turn it on again just yet).
10. Open the folder on the included CD-ROM corresponding to the operating
system version you are using, then run “Setupinf.exe” in the “Driver”
folder.
Initialize:
Set the [SELECT] switch to the
optical setting, then hold down
the CLOCK SOURCE button
while turning on the M-1000
(p. 18).
During the re-boot procedure,
USB indicator or internal
indicator (INT) of M-1000
irregulary blinks. But this is
not malfunction.
Please confirm USB indicator
lits after re-booting.
11. Turn the M-1000 back on.
12. Follow the instructions displayed to install the special driver. The M-1000's
USB and ADVANCED indicators light.
13. Go to “Start” → (“Settings” →) “Control Panels” → “Sound and Audio
Device” (, “Sound and Multimedia” or “Multimedia”); specify the M-1000
(or the USB audio device) as the priority device for audio.
14
You can choose any sampling
rate.
Page 15
With Macintosh
1.With the M-1000 disconnected, start up your computer.
2.Run “M-1000 USB Installer J” on the included CD-ROM.
USB Audio
3.Follow the instructions displayed to install the special driver.
4.Re-boot your computer.
5.Connect the M-1000 and the computer with a USB cable.
6.Turn on the M-1000. If in Advanced mode (ADVANCED indicator lit),
press the CLOCK SOURCE button to switch to Standard Driver mode
(ADVANCED indicator off), and turn the M-1000 off and then on again.
7.Wait five seconds for the standard drivers to be recognized automatically,
then go to Control Panels in the Apple menu and open the “Sound” control
panel. For “Input,” specify “USB Audio” (required when using the
standard driver).
8.Uncheck the “Play sound through output device” option.
9.Switch the M-1000 to Advanced mode (the ADVANCED indicator should
flash; turn the M-1000 off and then on again).
10. On the included CD-ROM, go to “Driver” → “ASIO” → “M-1000 ASIO1.0
16bit” and “M-1000 ASIO1.0 24bit.” Copy all of the drivers in the folder for
the ASIO-supported software you will be using to the “ASIO Drivers”
folder.
During the re-boot procedure,
USB indicator or internal
indicator (INT) of M-1000
irregulary blinks. But this is
not malfunction.
Please confirm USB indicator
lits after re-booting.
You can choose any sampling
rate.
11. Specify “M-1000 ASIO1.0 16bit” or “M-1000 ASIO1.0 24bit” in the settings
screen in each ASIO application.
Deleting the Special Drivers (Uninstall)
If the special driver is not installed according to the prescribed procedure, or if there
is some other problem, the computer may fail to recognize the M-1000. If this occurs,
first delete then reinstall the special driver.
For the exact procedure, refer to the document on the CD-ROM included with the M-
1000.
Windows
CD-ROM → “Driver” folder →
ReadMe_E.htm”
“
Macintosh
CD-ROM → “Driver” folder → “
ReadMe_E.htm”
“
operating system version you are using →
ReadMe” folder → “English” folder →
15
Page 16
Explanations
Digital Connections
Standards for Digital Input/Output
The M-1000 conforms to the “IEC60958,” “IEC 958" (input and output using a fixed
consumer format), and “EIAJ-CP-1201” (consumer format) standards for digital
input and output.
Word Clock and Sampling Frequency
When analog audio signals are converted into digital audio signals, the analog
signals are sampled at extremely short intervals of time, and those samples are
converted into a digital signal. The sampling frequency indicates how many times
this process is performed each second. The finer the divisions of time, the more
precise the conversion becomes.
In order to attain a high level of precision in the processing of digital audio signals
between multiple devices, these time segments must be synchronized. The signal
transmitted to achieve this is known as “word clock.”
When synchronizing, all the connected devices shall be specified as Word Clock
Master or Word Clock Slave (to control or to be controlled). In case you are using M1000 as Word Clock Slave (to be controlled), you need to specify the CLOCK SOURCE.
Word clock is transmitted via a different route (the [WORD CLOCK] connector) than
the audio signals, and all of the devices are synchronized to a single word clock. This
is used when synchronizing three or more devices.
IEC:
International Electrotechnical
Commission
EIAJ:
Electronic Industries
Association of Japan
WORD CLOCK [75Ω] and [THRU]
Example of synchronizing 3 units of M-1000
CB
termination
Clock signal passes through
The units A, B and C will be
synchronized in exact timing.
C
termination
[75Ω] ON/OFF (Termination ON/OFF)
When the M-1000 is connected as the terminus of a word clock connection,
termination is used (75Ω:ON). The resistance is 75 ohms, the same as that of the word
clock cable, and the signals are terminated.
If termination is not done correctly, it can disrupt the word clock signal's waveform,
causing distortion and noise in the sound. You only need to terminate the last device
in the chain.
BA
Re-create clock signal
The clock signal used for
syncronizaton of B unit will come
out to C unit. The lag between AC will be greater but the decline
of signal to C unit will be smaller.
masterslaveslave
A
masterslaveslave
The word clock signal
includes a high-frequency
component. When relaying
such signals, a measure
known as “termination”
needs to be used, in order
to prevent signals from
being reflected by both
ends of the cable.
16
Page 17
SRC
Normally, when transmitting digital audio signals between devices, including
digital sources sent to digital mixers, the sampling frequencies (SAMPLING FREQ)
of each device must be the same. If the different devices use differing rates, they
must be converted to the same master rate. In addition, the clocking or timing of the
clock signals of each signals of each signal must be exactly the same. This is usually
achieved by having one master clock and then slaving each digital device to that one
Master or Word Clock.
With the M-1000, each digital input 1--4 features its own sample rate converter
(SRC). This allows you to use devices that are set to different digital clock rates and
also that are not synchronized with each other by use of a master Word Clock. Each
input in the M-1000 is able to receive the following rates.
DIGITAL INPUT 1:Rate can be set to any frequency from 32 kHz to 96 kHz
DIGITAL INPUT 2--4:Rate can be set to 32 kHz, 44.1 kHz, 48 kHz, 88.2 kHz,
or 96 kHz
The appropriate sample rate conversion is performed internally in the M-1000 and
the signals are all synchronized to the master clock signal according to the clock
source and sample frequency settings on the M-1000. This conversion and clock
synchronization is done automatically, making it very easy to mix multiple digital
devices.
Explanations
SRC:
Sample Rate Converter
SCMS
→“About SCMS” (p. 20)
Other Points
Input Sensitivity Select Switch (SENS) and LEVEL Knobs
The input sensitivity select switch adjusts the input gain.
If the input volume level is set too low when converting an analog signal to digital,
the conversion accuracy suffers. Setting the input volume too high ends up
distorting the sound. Ideally, the input level prior to conversion should be as high as
possible without causing distortion. First, try a high input level with the input
sensitivity select switch set to [-10 dB]. If the PEAK indicator does not light, then use
the signal as is. If the PEAK indicator does light, it means the sound is going to be
distorted, so slide the switch to [+4 dB].
The LEVEL knobs work like channel faders on a digital recorder or similar device.
These adjust the volume level for each input. These affect the signals after they are
digitally converted.
MASTER Output and MONITOR Output
Both of these channel contain the mixed output of the M-1000. Normally, the
MASTER output is connected to house speakers or recording devices, and the
MONITOR output is connected to headphones or monitor speakers.
Although the output to the MONITOR bus is the same as the MASTER output,
changing the MONITOR output volume does not affect the volume of the MASTER
output.
SCMS:
Serial Copy Management
System
17
Page 18
Other Features
Initializing the Settings
---Restoring the M-1000 to Its Original Factory Conditions
You can use the following procedure to reset the settings to the default factory
condition.
1.Set the SELECT switch to OPTICAL.
2.Hold down the CLOCK SOURCE button and switch on the power to the
M-1000.
This resets the settings to their factory values.
Clock Source:INT (Internal Clock)
Internal Clock Sampling Frequency:44.1 kHz
USB Driver Mode:Standard Driver Mode
Sampling Frequency w/USB Connection:44.1 kHz
Changing the Signal Path for the Analog Output (MIX OUT)
- If the audio in the inputs is doubled in the output when using the USB connection -
The M-1000's internal signal
routing incorporates a switch
called [MIX OUT].
Normally, sounds input to the M1000 are output both through the
USB connection and the MASTER
output, but you can change the
[MIX OUT] setting to block the path from the analog input to the MASTER output.
When using the M-1000 in combination with another mixer, the way the connections
are made and the mixer is structured can cause sounds to be output twice. This
occurs in the following cases.
When connected via USB, the [MIX OUT] setting (Connect/Disconnect) is enabled.
When not connected via USB, [MIX OUT] remains connected at all times.
* Settings are saved even when the power is turned off.
ANALOG INMASTER OUT
USB
MIX OUT
Disconnecting the Path from ANALOG INPUT to MASTER OUT ([MIX OUT] off)
The analog input is transmitted only though USB.
Hold down the SAMPLING FREQ button for at least one second.
→The [96kHz], [48kHz], and [44.1kHz] indicators light for one second, indicating that the
path from ANALOG INPUT to MASTER OUT is disconnected.
Connecting the Path from ANALOG INPUT to MASTER OUT ([MIX OUT] on)
This is the normal setting. The analog input is sent both to the USB connector and
MASTER OUT.
18
Hold down the CLOCK SOURCE button for at least one second.
→The [ADVANCE], [96kHz:fromPC], and [96kHz:toPC] indicators light for one second,
indicating that the path from ANALOG INPUT to MASTER OUT is connected.
Page 19
Troubleshooting
If the M-1000 does not operate as you expect, check the problems and solutions listed below first. If this does not solve
the problem, consult with your retailer, the nearest Roland Service Center, or an authorized Roland distributor, as listed
on the “Information” (p. 26) page.
There is no sound.
This may be due to one or more of the following.
• The digital signals being input have a sampling rate that is not compatible with the M-1000.
→ Input signals that are compatible.
• The M-1000 is set to a sampling rate not compatible with the connected device.
→ Select a compatible sampling rate.
• The volume or level knob on the audio device is turned down too low.
→ Adjust to an appropriate level.
• The input sensitivity select switch is not at the right setting.
→ Try setting this to [-10dBu].
The volume level of the instrument connected to [ANALOG INPUT] is too low.
Could you be using a connection cable that contains a resistor?
→ Use a connection cable that does not contain a resistor.
The CLOCK SOURCE indicator is flashing.
This indicates that synchronization with the specified clock source could not be accomplished. In this case, the M-1000
switches to using its internal clock (INT).
This may be due to one or more of the following.
• The right signals are not reaching their corresponding connectors (such as when incompatible sampling rates are used).
• The M-1000 is not properly connected to the corresponding device.
→ Check the settings for the connected device, and make sure it is connected properly.
When connecting via USB, the indicators showing the driver and sampling rate are flashing.
These flash when you change USB-related settings. The flashing light indicates the “reserved” setting; when the M-1000
is turned off, then on again, that setting is enabled, and the indicator then remains lit.
→ When connecting via USB, turn the power off, then on again whenever you change the settings.
DIGITAL INPUT 1 is connected with a coaxial cable, but won't lock.
Is the digital input SELECT switch on the front panel set to OPTICAL?
→ Switch to match the connection.
Sounds cannot be exchanged with the PC after a change in the USB settings.
When changing settings, you need to exit all computer applications and restart the computer.
The volume levels for the device connected to the output connector is too low.
Could you be using a connection cable that contains a resistor?
→ Use a connection cable that doesn't incorporate a resistor (such as one from the Roland PCS Series).
Installation of the driver is requested when attempting to switch to USB Advanced mode.
If no M-1000 special driver has been installed, installation of the driver begins automatically if you try to switch to
Advanced mode.
→ Follow the instructions given to install the driver.
→ You can also follow the instructions in “Initializing the Settings ---Restoring the M-1000 to Its Original Factory
Conditions” (p. 18) to return to Standard Driver mode.
Sounds are doubled (played twice).
→ If using USB, try the procedure in “Disconnecting the Path from ANALOG INPUT to MASTER OUT ([MIX OUT]
off)” (p. 18).
19
Page 20
Concerning Copyright
The law prohibits the unauthorized recording, public performance, broadcast, sale, or distribution etc. of a
work (CD recording, video recording, broadcast, etc.) whose copyright is owned by a third party.
Roland will take no responsibility for any infringement of copyright that you may commit in using the M-
1000.
About SCMS
SCMS (Serial Copy Management System) is a function that protects the rights of the copyright owner by
prohibiting second-generation or later copying via a digital connection to a consumer digital audio device
such as a DAT recorder or MD recorder. When a recording is made via a digital connection on a digital
recorder that has this function, SCMS data will be recorded along with the digital audio signal. A digital audio
signal containing this SCMS data cannot be recorded again via a digital connection.
Disclaimer of liability
Roland will take no responsibility for any “direct damages,” “consequential damages,” or “any other
damages” which may result from your use of the M-1000. These damages may include but are not limited to
the following events which can occur when using the M-1000.
• Any loss of profit that may occur to you
• Permanent loss of your music or data
• Inability to continue using the M-1000 itself or a connected device
About the License Agreement
The M-1000 is designed to allow you to reproduce material to which you have copyright, or material which
the copyrighted material without permission of the copyright owner avoiding technical prohibiting feature of
second-generation and later copying like SCMS or others constitutes copyright infringement and may incur
penalties even in case such reproduction is for your own personal use and enjoyment (private use). Consult a
copyright specialist or special publications for more detailed information on obtaining such permission from
copyright holders.
20
Page 21
Specifications
Signal Processing
AD Conversion:24bits,64times oversampling
DA Conversion:24bits,128times oversampling
Internal Processing:56bits
Sampling Frequency:96kHz,48kHz,44.1kHz
Analog Input
Connector:1/4 inch phone type (unbalanced)
Input Level:-10dBu, +4dBu (switchable)
Maximum Input Level: +22 dBu (Input Level:+4dBu)
5100 S. Eastern Avenue
Los Angeles, CA 90040-2938,
U. S. A.
TEL: (323) 890 3700
As of August 1, 2002 (Roland)
Page 27
For EU Countries
This product complies with the requirements of European Directives EMC 89/336/EEC and LVD 73/23/EEC.
For the USA
FEDERAL COMMUNICATIONS COMMISSION
RADIO FREQUENCY INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Unauthorized changes or modification to this system can void the users authority to operate this equipment.
This equipment requires shielded interface cables in order to meet FCC class B Limit.
For Canada
NOTICE
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.
AVIS
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.