IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.
ENGLISH:
GERMAN:
FRENCH:
ITALIAN:
SPANISH:
PORTUGUESE:
POLISH:
This instruction sheet is available in multiple languages at www.rockwellautomation.com/literature. Se lect
publication language and type "SensaGuard" in the search field.
Dieses Instruktio nsblatt kann in mehreren Sprachen unter ww w.rockwellautomation. com/literature gelesen
werden. Bitte Ihre Sprache anwähl en und "SensaGuard" im Suchfeld eintippen.
Ces instructions sont disponibles dans différentes langues à l'adresse suivante
www.rockwellautomation.com/literature. Sélectionner la langue puis taper “SensaGuard” dans le champ de
recherche.
La presente scheda d'istruzione è disponibile in varie lingue sul sito www.rockwellautomation.com/literature.
Selezionare la lingua desiderata e digitare "SensaGuard" nel campo di ri cerca.
Puede encontrar esta hoja de i nstrucciones en varios idiomas en www.rockwel lautomation.com/literature.
Seleccione el idioma de pu blicación y escriba "SensaGuard" en el campo de búsque da.
Esta folha de instruções está disponível em várias línguas em www.rockwell automation.com/literature.
Seleccione a língua de publicação e entre com "SensaGuard" no espaço de busca.
Ta kartka z instrukcjami jest dostepna w wielu jezykach na stronie: www.rockwellautomation.com/literature
Wybierz jezyk publikacji i wpisz w polu poszukiwania "SensaGuard".
Installation Instructions
Installation must be in accordance with the following steps and
stated specifications and should be carried out by suitable
competent personnel. The unit is not to be used as a mechanical
stop. Guard stops and guides must be fitted. Adherence to the
recommended maintenance instructions forms part of the
warranty.
This device is intended to be part of the safety related control
system of a machine. Before installation, a risk assessment should
be performed to determine whether the specifications of this
device are suitable for all foreseeable operational and
environmental characteristics of the machine to which it is to be
fitted. Refer to Technical Specifications below for certification
information and ratings.
The presence of spare actuators compromise the
ATTENTION
integrity of the safety systems. Personal injury or
death, property damage or economic loss can
result. Appropriate management controls,
working procedures and alternative protective
measures should be introduced to control their
use and availability.
Do not defeat, tamper, remove or bypass this unit.
Severe injury to personnel could result. The sensor
MUST be connected to a Class 2 SELV 24V DC,
+10%/-15% power supply.
Operating Characteristics
Sensing Distance
Assured Make15 mm
Assured OFF35 mm
Typical Misalignment(±7 mm in both axes)
Repeat Accuracy10% of sensing range
Max. output current (all outputs)200 mA
Input Current50 mA (no load supply current)
Operational Current, Min.≥1 mA DC
Off-state Current<0.5 mA DC
Max. no. of switches, connected in series
Operating Voltage
Unlimited. See Unit Response Time
section on page 5.
24V DC +10%/-15%
Class 2 SELV power supply
Frequency of operating cycle1 Hz
Response Time (Off)
54 ms first switch,
18 ms for each additional switch
Case MaterialValox® DR 48
Actuator Materia lValox® DR 48
Outputs
(guard door closed, actuator in place)
OutputsDescriptionStatus
Safety2 x PNP, 0.2 A max.ON (+24V DC)
Auxiliary1 x PNP, 0.2 A max.OFF (0V DC)
Environmental
Technical Specifications
Type 4 Interlocking Device per ISO 14119 (Low Coding)
Safety Classification
Standards
CertificationsTÜV, CE Marked for all applicable directives, cULus
Functional Safety Data
PLe, Cat 4 per ISO 13849-1
SIL CL3 per IEC 62061 and IEC 61508
CSA 22.2 No. 14, ISO13849-1, ISO 14119, IEC 60947-5-3,
IEC 61508, IEC 62061, and UL508
-9
: 1.12 - 10
PFH
D
Operating Temperature [C (F)]-10…+55° (14…131°)
Operating Humidity5…95% relative
Washdown RatingNEMA 3, 4X, 12, 13, IP69k
Shock & Vibration
Radio Frequency
IEC 68-2-27 30 g, 11 ms/IEC 68-2-6
10…55 Hz
IEC 61000-4-3
IEC 61000-4-6
Page 2
Protection
24.99
(0.984)
88.14
(3.47)
10.66
(0.42)
7.11
(0.28)
6.78
(0.267)
4.57
(0.18)
Ø5.08
(Ø0.2)
4.57
(0.18)
68.31
(2.689)
18.54
(0.73)
72.9
(2.87)
77.98
(3.07)
20.65
(0.813)
24.99
(0.984)
88.14
(3.47)
20.65
(0.813)
4.57
(0.18)
18.54
(0.73)
10.67
(0.42)
13.41
(0.528)
9.96
(0.392)
QD
CONNECTOR
VERSION
M12 x 1
¯ 9.7
(¯ 0.38)
4.57
(0.18)
Ø5.08
(Ø0.2)
4.57
(0.18)
77.98
(3.07)
62.53
(2.462)
57.96
(2.282)
82.55
(3.25)
Short-circuit Incorporated
Current LimitationIncorporated
OverloadIncorporated
False PulseIncorporated
Tra nsi ent Noi seIn cor por ated
Reverse PolarityIncorporated
OvervoltageIncorporated
Thermal Shutdown/RestartIncorporated
Electrical Life
10 x 10
Dimensions [mm (in.)]
6
Mode of Operation
Status indicators:
• “Status/Diag” LED illuminates green: Door/guard closed,
safety outputs active.
• “Status/Diag” LED illuminates red: Door/guard open,
safety outputs off.
• “Status/Diag” LED flashes red: Unit failure. See Diagnostic
section on page 4.
• “Status/Diag” LED flashes green: Safety inputs off.
• “Status/Diag” LED flashes amber: Sensor is approaching
max. sensing distance. (-N and -N9 models only)
2
Mounting Information
Use non-removable screws, bolts, or nuts to mount the switch and
actuator. Do not over torque the mounting hardware.
Position the switch and actuator so they are aligned with each
other.
Mount the switch and actuator to removable guard, door, or gate.
Keep the switch and actuator within the sensing range shown in
the sensing/misalignment curve.
Nut Torque Specification
Switch/Actuator: 2.26 N•m (20 in•lb)
Page 3
Minimum Distance Between Sensors
200.00 mm
5
10
15
20
25
30
35
SIDE
LOBES
Sensing Distance* (mm)
0
SIDE
LOBES
ASSURED
SENSING
DIS TANC E
* when the actuator approaches the sensor in the x-direction or
from above (z-direction) and is misaligned in the y-direction
SensorActuator
Misalignment (mm)
Assured Make: 15 mm
Assured OFF: 35 mm
x
z
y
Sensor
Actuator
Actuator
IMPORTANT
5
10
15
20
25
30
35
Sensing Distance** (mm)
0
23
23
50
40
30
20
30
0
10
20
10
40
50
50
40
30
20
30
0
10
20
10
40
50
Misalignment (mm)
** when the actuator approaches the sensor in the
x-direction and is misaligned in the z-direction.
SensorActuator
ASSURED
SENSING
DISTANCE
Assured Make: 15 mm
Assured OFF: 35 mm
x
SensorActuator
zz
Misalignment Curve
Wiring Diagram
Allow a minimum spacing of 9 mm (0.35 in.) if the
actuator and sensor faces approach laterally (from
the y-direction). This will prevent false triggering
due to the side lobe areas.
To ensure proper functioning of margin indication
(non-safety), z-direction approach is not
recommended for -N and -N9 models.
3
8-Pin Unit
Pin NumberWire ColorSignal
1WhiteAux. Outputs
2Brown+24V
3GreenNA
4YellowOSSD 2, +24V Input
5GreyOSSD 1
6PinkOSSD 2
7Blue0V
8RedOSSD 1, +24V Input
Recommended mating cable, 2 m (6.5 ft)—889D-F8AB-2.
Replace the 2 with 5 (5 m) or 10 (10 m) for standard cable lengths.
Green
1
2
3
8
476
Red
Yellow
5
Brown
White
Blue
Pink
Grey
Page 4
5-Pin Unit
15
2
4
3
IMPORTANT
Pin NumberSignal
1+24V
2OSSD 1
30V
4OSSD 2
5Aux.
Recommended cordset, 2m (6.5 ft) - 889D-F5AC-2. Replace the
2 with 5 (5 m) or 10 (10 m) for standard cable lengths.
Note: If the user does not require the Auxiliary signal, a 4-pin
cordset (889D-F4AC-2) can be used.
Recommended patchcord for use with ArmorBlock® Guard
Safety I/O, 2 m (6.5 ft) - 889D-F4ACDM-2. Replace the 2 with
0M3 (0.3 m), 1 (1 m), 5 (5 m), or 10 (10 m) for standard cable
lengths.
Note: Do not use a 5-pin patchcord with the ArmorBlock.
Diagnostic
Unit Indicators (per IEC 60073)
StateStatusTroubleshooting
OffNot PoweredNA
RedNot Safe, OSSD not activeNA
GreenSafe, OSSD activeNA
Device
Output
LED
Green Flash
Red Flash
Amber Flash
(-N & -N9
models only)
Refer to Technical Specifications (page 1) for
certification information and ratings.
Power up test or OSSD
inputs not valid
1 Hz Flash Recoverable Fault
4 Hz Flash Non-recoverable
Fau lt
1 Hz Flash margin indicator
Safe, OSSD active
Check 24V DC or OSSD
inputs (yellow and red wire)
Recoverable fault —check
OSSD outputs are not
shorted to GND, 24V DC or
each other. Cycle power.
Sensor is reaching max.
sensing distance; realign
sensor with actuator
4
Page 5
Troubleshooting
Yel
Red
Brown
Gray
Pink
Blue
24VDC
Power
Supply
1606
-XL120D
Switch 1
+24
RTN
Switch 2
White
White
Yel
Red
Brown
Gray
Pink
Blue
Actuator 1
Actuator 2
Switch 3
White
Yel
Red
Brown
Gray
Pink
Blue
Actuator 3
Switch 4
White
Yel
Red
Brown
Gray
Pink
Blue
Actuator 4
Switch 5
White
Yel
Red
Brown
Gray
Pink
Blue
Actuator 5
+24 V
+24 V
+24 V
+24 V
+0 V
+0 V
+0 V
+0 V
+0 V
+0 V
Actuator 2 is in sensing range.
Switch
2 is functioning properly
OSSDs are energize to 24 V
Green LED is ON.
Actuator 3 is in sensing range.
Switch
3 has fault.
See Table Above—Red LED is flashing
Actuator 1 is in sensing range.
Switch
1 is functioning properly
OSSDs are energize to 24 V
Green LED is ON.
Actuator 4 is in sensing range.
Switch
4 is functioning properly.
Series inputs are 0 V.
OSSDs are de-energized to 0V .
Green LED is Flashing to indicate
Series inputs are not 24V.
Actuator 5 is in sensing range.
Switch
5 is functioning properly .
Series inputs are 0V .
OSSDs are de-energized to 0V.
Green LED is Flashing to indicate
Series inputs are not 24V.
OSSD’s are OFF
Recoverable fault
IMPORTANT
Yel
Red
White
Gray
Pink
Blue
24V DC
Power
Supply
1606
Sensor 1
+24
RT
Sensor 2
Brown
Brown
Gray
Pink
White
Yel
Red
Blue
Sensor 3
Brown
Yel
Red
White
Gray
Pink
Blue
A1
S21
S1141332313S12S52
42342414A2S34S22
MSR127TP
Actuator 1
Actuator 2
Actuator 3
Initial Conditions:
All actuators are in sensing
distance.
Actuator 1 is moved out of
sensing range.
Sensor 2 drops the 24 volts
(red and yellow) from Sensor 1
OSSD outputs.
Green LED flashes.
Sensor 3 drops the 24 volts
(red and yellow) from Sensor 2
OSSD outputs.
Green LED flashes.
0 ms
54 ms72 ms90 ms
Actuator 1 is out of sensing
range.
Actuator 2 and 3 are in
sensing range.
Actuator 1 is moved into sensing
range.
Sensor 1 OSSD outputs are
energized.
Sensor 2 OSSD inputs (red and yellow)
transition to 24V DC from Sensor 1
OSSD outputs.
Sensor 2 OSSD outputs are energized
Sensor 3 OSSD inputs (red and
yellow) transition to 24V DC from
Sensor 2 OSSD outputs.
Sensor 3 OSSD outputs are
energized.
0 ms
360 ms378 ms396 ms
OFF
ON
IMPORTANT
Series Circuit
Refer to Technical Specifications (page 1) for
certification information and ratings.
Unit Response Time (does not include safety control system response time)
5
Refer to Technical Specifications (page 1) for
certification information and ratings.
Page 6
Application Wiring Examples
K1
+24V DC
MSR127RP with 1 sensor, monitored manual reset, driving 100S or 700S safety controllers.
A1 S11
S52 S121323 33
41
S21
S22
S34A214 24 34 42
MSR127RP
Reset
GND
Blue
Gray
Pink
Yellow
Red
Brown
SensaGuard
Unit 1
K2
+24V DC
GND
MSR127RP with 3 sensors in series, monitored manual reset, driving 100S or 700S safety controllers
Blue
Gray
Pink
Yellow
Red
Brown
SensaGuard
Unit 1
SensaGuard
Unit 2
SensaGuard
Unit 3
K1
A1 S11
S52 S121323 33
41
S21 S22 S34 A2 14 24 34 42
MSR127RP
Reset
K2
Blue
Gray
Pink
Yellow
Red
Brown
Blue
Gray
Pink
Yellow
Red
Brown
MSR127RP with 3 sensors and 1 440L light curtain in series, monitored manual reset, driving 100S or 700S safety relays.
Note: Light curtain must be last (farthest from MSR127).
GND
A1 S11
S52 S121323 33
41
S21 S22 S34 A2 14 24 34 42
MSR127RP
Reset
K1
K2
+24V DC
Blue
Gray
Pink
Yellow
Red
Brown
SensaGuard
Unit 1
SensaGuard
Unit 2
SensaGuard
Unit 3
GuardShield
Blue
Gray
Pink
Yellow
Red
Brown
Blue
Gray
Pink
Yellow
Red
Brown
Blue
Gray
Pink
Brown
A1 S11
S52 S121323 33
41
S21
S22
S34A214 24 34 42
MSR127TP
GND
MSR127RP with 1 sensor, automatic reset, driving 100S or 700S safety controllers
+24V DC
SensaGuard
Unit 1
K1
K2
Blue
Gray
Pink
Yellow
Red
Brown
MSR127TP with 3 sensors in series, automatic reset, driving 100S or 700S relays.
MSR127TP
+24V DC
GND
Blue
Gray
Pink
Yellow
Red
Brown
SensaGuard
Unit 1
K1
A1 S11
S52 S121323 33
41
S21 S22 S34 A2 14 24 34 42
K2
Blue
Gray
Pink
Yellow
Red
Brown
Blue
Gray
Pink
Yellow
Red
Brown
SensaGuard
Unit 3
SensaGuard
Unit 2
MSR127TP with 3 sensors and 1 440L light curtain in series, automatic reset, driving 100S or 700S safety contactors.
Note: Light curtain must be last (farthest from MSR127)
MSR127TP
GND
A1 S11
S52 S121323 33
41
S21 S22 S34 A2 14 24 34 42
K1
K2
+24V DC
Blue
Gray
Pink
Yellow
Red
Brown
Blue
Gray
Pink
Yellow
Red
Brown
Blue
Gray
Pink
Yellow
Red
Brown
Blue
Gray
Pink
Brown
GuardShield
SensaGuard
Unit 1
SensaGuard
Unit 3
SensaGuard
Unit 2
IMPORTANT
Refer to Technical Specifications (page 1) for
certification information and ratings.
6
Page 7
Application Wiring Examples
A1
S11
S21
S12
S22
S32
L11Y32L121314
S42
2324S34
A2
DI
440R-D22R2
0
1
2
3
4
56
7
8
LOGIC
K1
K2
SensaGuard
SensaGuard
+24V DC
K1
K2
Reset
889D-F4AC-*
889D-F5AC-*
24V Com
Brown
Blue
Black
White
Brown
Blue
Grey
Black
White
Gate
Open
889D-F5AC-*
K1
K2
S11
S12
S21
S22
S34A1 13
L11A2 142324Y32
SI
440R-S12R2
RESET
0
MM
AM
24V DC
24V DC Com
Brown
Blue
White
Black
SensaGuard Integrated Latch
Reset
Gate
Open
Grey
IMPORTANT
889D-F8AB-*
A1
S11
S21
S12
S22
S32
L11Y32L121314
S42
2324S34
A2
DI
440R-D22R2
0
1
2
3
4
56
7
8
LOGIC
K1
K2
K1
K2
S11
S12
S21
S22
S34A1 13
L11A2 142324Y32
SI
440R-S12R2
RESET
0
MM
AM
SensaGuard
SensaGuard
+24V DC
K1
K2
Reset
889D-F8AB-*
889D-F8AB-*
24V Com
Note: The Green wire is connected to the housing of the Stainless Steel
SensaGuard only; it has no connection for plastic SensaGuard.
Brown
Yel lo w
Yel lo w
Red
Red
Blue
Pink
Grey
Pink
Grey
Brown
Blue
Green
White
Green
White
Gates
Open
24V DC
24V DC Com
Brown
Yellow
Red
Blue
White
Pink
SensaGuard Integrated Latch
Reset
Gate
Open
Grey
Green
Refer to Technical Specifications (page 1) for
certification information and ratings.
Check the machine is
isolated and stopped
whenever the interlocked
guard door is open.
IMPORTANT: After
installation and
commissioning, the
actuator, switch and switch
lid fixing screws should be
coated with tamper evident
varnish or similar compound.
Maintenance
Monthly
Check the correct operation of the switching circuit. Also check for signs of abuse or tampering. Inspect the switch casing for damage.
Repair
If there is any malfunction or damage, no attempts at repair should be made. The unit should be replaced before machine operation is
allowed.
Declaration of Conformity
This is to declare that the products shown in this document conform with the Essential Health and Safety Requirements (EHSRs) of the
European Machinery Directive. These products also conform to EN60947-5-3, EN ISO 14119, and have Third Party Approval.
For a comprehensive certificate please visit: www.ab.com/safety.
Allen-Bradley, CompactBlock, Rockwell Software, and SensaGuard are trademarks of Rockwell Automation, Inc.
Rockwell Automation maintains current product environmental information on its website at