Rockwell Automation PowerFlex 1203-USB User Manual

Page 1
Chapter 1
Getting Started
The 1203-USB converter provides a communications interface between a computer and any Allen-Bradley product supporting these drive communication interfaces:
®
DSI (Drive Serial Interface) for PowerFlex 4-Class drives, PowerFlex 520-Series drives, and Kinetix 3 drives
SCANport for legacy 1305 drives, 1336 drives, and so forth
7-Class drives and
The 1203-USB converter uses the full-duplex, RS-232 DF1 protocol
Topic Page
Components
Features
Compatible Products 1-3
Required Equipment 1-4
Safety Precautions 1-6
Quick Start 1-6
1-2
1-2
.
PowerFlex 1203-USB Converter User Manual
Publication DRIVES-UM001D-EN-P
Page 2
1-2 Getting Started
➍➎➏
Cables Supplied with 1203-USB Converter
Cable Required for
Kinetix 3 Drive
(ordered separately)
1203-USB Converter
Components
Item Part Description
Computer Cable Port Plug the USB cable into this port.
Status Indicators LEDs that indicate converter operation, data being received from
Drive Cable Port DPI Drives or SCANport Legacy Drives:
20-HIM-H10 Cable DPI or SCANport drive cable (1 m length) with male
22-HIM-H10 Cable
USB Cable USB cable (2 m length) with a Type B connector on one end to
2090-CCMUSDS-48AA0x
Cable (ordered separately)
the computer, and data being sent to the computer. For more information, see Chapter 4, Troubleshooting.
Plug the 20-HIM-H10 cable into this port.
DSI Drives: Plug the 22-HIM-H10 cable (for PowerFlex drives) or the 2090-CCMUSDS-48AA0x cable (for Kinetix 3 drives) into this port.
26-pin-to-male 8-pin circular mini-DIN connectors.
DSI drive cable (1 m length) with male 26-pin-to-male RJ45 connectors for use with PowerFlex drives.
connect to the 1203-USB converter, and a Type A connector on the other end of the cable to connect to a computer.
DSI drive cable (1 m or 3 m length) with male 26-pin-to-male 6-pin IEEE 1394 connectors for use with Kinetix 3 drives.
Features
The features of the 1203-USB converter include the following:
Connects to, and is compatible with, products that support the Allen-Bradley DPI, DSI, and SCANport dri v e communicatio n interfaces (see Compatible Products
The 1203-USB converter autobauds to the appropriate communication data rate that is used by the drive.
Provides a means for configuration software tools to access parameters in supported drives.
PowerFlex 1203-USB Converter User Manual
Publication DRIVES-UM001D-EN-P
on page 1-3).
Page 3
Getting Started 1-3
Compatibility with various drive configuration tools to configure the 1203-USB converter and connected drive as shown below.
Configuration Tool 1203-USB DPI Drive DSI Drive SCANport Drive
Connected Components Workbench Software, version 1.02 or later
DriveExplorer Lite or Full software, version 4.04 or later
DriveExecutive software, version 1.01 or later
Terminal emulation software, such as HyperTerminal
(1)
Except PowerFlex 520-Series drives and Kinetix 3 drives.
Status indicators to report the operating status of the converter.
Fixed baud rate of 115.2 kbps.
Receives po wer from the connected host dri v e, eliminating the need for a
dedicated power source.
Ye s Ye s Ye s N o
(1)
Ye s Ye s Ye s
Ye s Ye s Ye s
Yes not recommended
Ye s
(1)
Ye s
Compatible Products
Upgradable firmware to get new features as they become available.
At the time of publication, the 1203-USB converter is compatible with the following products.
TIP: Also check the supported products by the various drive software tools. For example, the PowerFlex 520-Series drives and Kinetix 3 drives are only supported by Connected Components Workbench software and not DriveExplorer or DriveExecutive software.
DPI Products
PowerFlex 70/70EC drives
PowerFlex 700/700VC drives
PowerFlex 700 Series B drives
PowerFlex 700H drives
PowerFlex 700S drives
PowerFlex 700L
PowerFlex 753 drives
PowerFlex 755 drives
PowerFlex Digital DC drives
PowerFlex 7000 drives
SMC
SMC-50 Smart Motor Controllers
MSR57 Speed Monitoring Safety Relays
Flex Smart Motor Controllers
PowerFlex 1203-USB Converter User Manual
Publication DRIVES-UM001D-EN-P
Page 4
1-4 Getting Started
DSI Products
PowerFlex 4 drives
PowerFlex 4M drives
PowerFlex 40 drives
PowerFlex 40P drives
PowerFlex 400 drives
PowerFlex 520-Series drives (Some limitations of use - Custom groups
and Application groups are not supported)
Kinetix 3 drives (Only point-to-point connection supported)
SCANport Products
1305 AC drives, firmware 2.01 or later
1336 FORCE
1336 IMPACT
1336 PLUS drives
1336 PLUS II drives
1336 REGEN Line Regeneration Packag es
1336 SPIDER drives
1394 Motion systems
1397 DC drives
1557 Medium Voltage drives
2364 Regenerative DC Bus Supply Units
SMC Dialog Plus
SMP-3 Smart Motor Protectors
drives
drives
Smart Motor Controllers
Required Equipment
Most of the equipment that is required to use the 1203-USB converter is shipped with the converter, but some equipment you must supply yourself.
Equipment Shipped with the Converter
When you unpack the converter, verify that the package includes the following:
One 1203-USB converterOne USB cable, 2 m (6.6 ft.) longOne 20-HIM-H10 cable, 1 m (3.3 ft.) longOne 22-HIM-H10 cable, 1 m (3.3 ft.) long
PowerFlex 1203-USB Converter User Manual
Publication DRIVES-UM001D-EN-P
Page 5
Getting Started 1-5
User-Supplied Equipment
To configure the 1203-USB converter and connected Allen-Bradley drives, you must supply one of the following drive configuration software tools on your computer:
Connected Components Workbench software, version 1.02 or later
Connected Components Workbench is the recommended stand-alone software tool for use with PowerFlex driv es. You can obtain a free copy by:
Internet download at http://www.ab.com/support/abdrives/
webupdate/software.html
Requesting a DVD at http://www.ab.com/onecontact/controllers/
micro800/
Your local distributor may also have copies of the DVD available. Connected Components Workbench software cannot be used to
configure SCANport-based drives or Bulletin 160 drives. Use one of the other drive software tools listed below for this specific purpose.
DriveExplorer software, version 4.04 or later
This software tool has been discontinued and is now available as freeware at http://www.ab.com/support/abdrives/webupdate/
software.html. There are no plans to provide future updates to this tool
and the download is being provided ‘as-is’ for users that lost their DriveExplorer CD, or need to configure legacy products not supported by Connected Components Workbench software.
DriveExecutive software, version 1.01 or later
A Lite version of DriveExecutive software ships with RSLogix 5000, RSNetWorx MD, FactoryTalk AssetCentre, and IntelliCENTER software. All other versions are purchasable items:
9303-4DTE01ENE DriveExecutive software
9303-4DTS01ENE DriveTools SP Suite (includes DriveExecutive
and DriveObserver software)
9303-4DTE2S01ENE DriveExecutive software upgrade to DriveTools SP Suite (adds DriveObserver software)
DriveExecutive software updates (patches, and so forth) can be obtained at http://www.ab.com/support/abdrives/webupdate/
software.html. It is highly recommended that you periodically check
for and install the latest update.
Terminal emulation software, such as HyperTerminal
PowerFlex 1203-USB Converter User Manual
Publication DRIVES-UM001D-EN-P
Page 6
1-6 Getting Started
!
!
Safety Precautions
Quick Start
Please read the following safety precautions carefully.
ATTENTION: Risk of injury or equipment damage exists. Only personnel familiar with drive and power products and the associated machinery should plan or implement the installation, startup, configuration, and subsequent maintenance of the product using the converter. Failure to comply may result in injury and/or equipment damage.
ATTENTION: Risk of injury or equipment damage exists. If the converter is transmitt ing control I/O to the drive (indicated by a steady green Diamond status indicator), the drive may fault when you remove or reset the converter. Determine how your drive will respond before removing or resetting a connected converter.
This section is provided to help experienced users quickly start using the 1203-USB converter. If you are unsure how to complete a step, refer to the referenced chapter.
Step Action See
1 Review the safety precautions for the converter. Throughout this manual
2 Install the converter.
When used with DPI drives or SCANport drives:
a. Connect the 1203-USB converter to the drive with a
20-HIM-H10 cable (see Figure 1.1).
b. Connect the 1203-USB converter to a computer with a USB
cable.
Make sure that power has been applied to the drive.
When used with DSI drives:
a. Connect the 1203-USB converter to the PowerFlex drive
with a 22-HIM-H10 cable, or to the Kinetix 3 drive with a 2090-CCMUSDS-48AA0x cable (see Figure 1.2
b. Connect the 1203-USB converter to a computer with a USB
cable.
Make sure that power has been applied to the drive.
3 Install the 1203-USB driver and USB serial port driver. Installing the USB Drivers on
).
4 Configure the converter for your application.
Use one of the following tools to configure parameters in the converter:
Connected Components Workbench software, version 1.02 or later
DriveExplorer software, version 4.04 or later
DriveExecutive software, version 1.01 or later
Terminal emulation software, such as HyperTerminal
Chapter 2 Converter
page 2-4
Chapter 3 Converter, or
Appendix DriveExplorer Software, or
Appendix DriveExecutive Software, or
Appendix E, Use with HyperTerminal Software
C, Use with
D, Use with
, Installing the
, Configuring the
PowerFlex 1203-USB Converter User Manual
Publication DRIVES-UM001D-EN-P
Page 7
Getting Started 1-7
DPI or SCANport Drive
(PowerFlex 70 shown)
1203-USB
Converter
Computer
(Laptop or Desktop)
20-HIM-H10
Cable
USB Cable
DSI Drive
(PowerFlex 40 shown)
1203-USB
Converter
Computer
(Laptop or Desktop)
USB Cable
22-HIM-H10
Cable
Kinetix 3 Drive
2090-CCMUSDS-48AA0x
Cable (ordered separately)
or
Figure 1.1 Connecting the Converter Between a DPI or SCANport Drive and
Computer
Figure 1.2 Connecting the Converter Between a DSI Drive and Computer
PowerFlex 1203-USB Converter User Manual
Publication DRIVES-UM001D-EN-P
Loading...