(y1) ACCESSORIES
Resistrox security fixing screws (2 x M5)
Security screwdriver
Replacement Resistorx security key
Catch and retainer kit
Flexible/adjustable actuator and guide
Semi flexible actuator and guide
Replacement actuators are available by arrangement.
Note: Access to spare actuators should be restricted to
authorised personnel to prevent bypassing of the safety function
(z1) MAINTENANCE
Every Week
Check alignment of actuator to switch and the correct operation of
the switching circuit. Also check for signs of abuse or tampering.
Inspect the switch casing & actuator for damage. Of particular
importance is damage which causes loss of sealing at the lid or
conduit entry, distortion of the actuator & damage to catch/entry
point and cam mechanism. Replace if apparent.
At least every 6 months
Isolate all power! Remove the lid & end cover with the security bit
provided. Inspect all terminals for tightness. Clean out any
accumulation of fine dirt etc. Check for any sign of wear or damage,
e.g. actuator wear, cam assembly wear, contact oxidisation etc. and
replace if apparent. Replace covers & fully tighten the security screws.
Reinstate the power & check for correct operation. Re-apply tamper
evident varnish or similar compound to fixings.
ZUBEHÖR
Resistorx Sicherheitsschrauben (2 x M5)
TORX-Bit-Handhalter
TORX-Bit
Verschluß- und Halterungssatz
Flexibler/einstellb. Betätiger und Führung
Semi-Flexibler Betätiger
Ersatzbetätiger auf Anfrage
Anmerkung: Ersatzbetätiger dürfen nur autorisierten Personen
zugänglich sein, um ein Umgehen der Sicherheitsfunktion zu verhindern.
WARTUNG
Wöchentlich
Ausrichtung des Betätigers auf Schalter sowie korrekten Betrieb des
Schaltkreises überprüfen. Nach Zeichen für Mißbrauch oder unbefugte
Eingriffe suchen. Schaltergehäuse und Betätiger auf Beschädigungen
überprüfen. Besonders wichtig sind Überprüfungen auf Schäden, die
Dichtungsverluste am Deckel oder am Leitungsrohreingang,
Verformung des Betätigers & Beschädigung am Verschluß/Eingangspunkt und am Nockenmechanismus auslösen. Ggf.
ersetzen.
Mind. Alle 6 Monate
Strom abschalten! Deckel und Endkappe mit dem mitgelieferten
TORX-Bit abnehmen. Alle Anschlüsse auf festen Sitz überprüfen.
Jeglichen feinen Schmutz usw. entfernen. Auf Verschleiß oder
Schäden z.B. am Betätiger und der Nockenanordnung sowie auf
Kontaktoxidation usw. untersuchen und ggf. ersetzen. Deckel wieder
aufsetzen und Sicherheitsschrauben anziehen. Maschine wieder
anschalten & auf korrekten Betrieb prüfen. Neubehandlung der
Halterungen mit Lack oder ähnlichem Material, um Eingriffe
aufzuzeigen.
ACCESSOIRES
Vis de fixation de sécurité Resistrox (2xM5)
Tournevis de sécurité
Remplacement enbout tournevis
Kit de maintien
Broche flexible/réglable et dispositif de guidage
Broche semi-flexible et guide
Broche de remplacement
Note : L’accès à l’appareil doit être restreint au personnel autorisé pour
éviter toute fraude de la fonction de sécurité.
MAINTENANCE
Chaque semaine
Contrôler l'alignement de broche avec l'interrupteur, et le fonctionnement
correct du circuit de commutation. Vérifiez s'il y a des traces de
manipulation frauduleuse ou d'abus. Assurez-vous que ni le boîtier de
l'interrupteur ni l'actionneur ne soient endommagés. De nombreuses
pannes sont provoquées par la perte de l’étanchéité du couvercle et du
presse-étoupe, par la déformation de la broche, par la dégradation du kit
de maintien ou du point d’entrée de la broche, par la dégradation du
mécanisme à came. Dans ce cas, remplacez l'appareil.
Tous les 6 mois au moins
Coupez l'alimentation de la machine. Retirez le couvercle d'extrémité et
le capot à l'aide de l'accessoire de sécurité fourni. Vérifiez les connexions
aux bornes. Enlevez toute poussière accumulée, etc. Vérifiez s'il y a des
traces d'usure ou de dommages, e.g. usure de la broche, du mécanisme
à came, oxydation des contacts, etc. Dans ce cas, remplacez le dispositif.
Remettez les couvercles en place et serrez à fond les vis de sécurité.
Enclenchez l'alimentation et contrôlez le bon fonctionnement de
l'ensemble. Appliquez une couche de vernis ou autre produit semblable
aux fixations.
TROJAN T15
(a) Description
The Trojan T15 is a positive mode, tongue operated interlock switch. It interlocks
the guard to the machine control system.
(b) Installation Instructions
RETAIN THESE INSTRUCTIONS
Installation must be in accordance with the following steps and must be
carried out by suitably competent personnel.
This device is intended to be part of the safety related control system of a
machine. Before installation, a risk assessment should be performed to
determine whether the specifications of this device are suitable for all
foreseeable operational and environmental characteristics of the machine to
which it is to be fitted.
At regular intervals during the life of the machine check whether these
characteristics foreseen remain valid and inspect this device for evidence of
accelerated wear, material degradation or tampering. If necessary the device
should be replaced . Guardmaster cannot accept responsibility for a failure of
this device if the procedures given in this sheet are not implemented or if it
is used outside the recommended specifications in this sheet.
The interlock is not to be used as a mechanical stop.
Guard stops and guides must be fitted.
Exposure to shock and/or vibration in excess of those stated in
IEC 68 part: 2-6/7 should be prevented.
Adherence to the recommended maintenance instructions forms part of the
warranty.
TONGUE OPERATED GUARD INTERLOCK SWITCH
ZUNGENBETRIEBENER SCHUTZGITTER-SICHERHEITSSCHALTER
INTERRUPTEUR DE SECURITE UNIVERSEL A BROCHE POUR PROTECTEUR
Beschreibung
Der Trojan T15 ist ein zwangsgeführter, zungenbetriebener Verriegelungsschalter. Er
verriegelt das Schutzgitter um das Maschinensteuerungssystem.
Einbauanleitung
DIESE ANLEITUNG AUFBEWAHREN
Der Einbau muß durch einen entsprechend qualifizierten Mitarbeiter
erfolgen, und folgende Schritte müssen hierbei beachtet werden.
Dieses Gerät ist für den Einsatz als Teil des sicherheitsbezogenen
Steuerungssystems einer Maschine gedacht. Vor dem Einbau sollte eine
Risikoanalyse durchgeführt werden, um festzustellen, ob sich dieses
Geräts technisch für alle voraussehbaren Betriebs- und
Umweltsbedingungen der Maschine, für die es bestimmt ist, eignet.
Prüfen Sie in regelmäßigen Abständen während der Lebensdauer der
Maschine, ob diese voraussehbaren Bedingungen auch weiterhin gelten,
und überprüfen sie dieses Gerät auf vorschnellen Verschleiß,
Qualitätsverlust des Materials oder unbefugte Eingriffe. Ggf. sollte das Gerät
ausgewechselt werden. Guardmaster kann keine Haftung für ein Versagen
dieses Geräts übernehmen, wenn die auf diesen Seiten aufgeführten
Verfahren nicht angewandt werden oder wenn das Gerät nicht laut der
empfohlenen Spezifikationen verwendet wird. Der Sicherheitsschalter darf
nicht als mechanische Sperre verwendet werden. Schutzgittersperren und leitvorrichtungen müssen angebracht werden.
Das Gerät sollte keinen Stößen und/oder Erschütterungen ausgesetzt
werden, die stärker sind als die in IEC68 Teil: 2-6/7 beschriebenen.
Die Einhaltung der empfohlenen Wartungsanweisungen ist Teil der Garantie.
Description
Le Trojan T15 est un interrupteur de verrouillage de porte actionné par une broche. Il
contrôle en fermeture la porte de la machine.
Notice d'installation
INSTRUCTIONS A RETENIR
L'installation doit être menée conformément aux étapes suivantes et doit
être effectuée par un personnel expérimenté.
Cet appareil est destiné à faire partie du système de contrôle de sécurité
d'une machine. Avant l'installation, on doit procéder à une estimation de
risque afin de déterminer si les spécifications de l'appareil conviennent à
toutes les caractéristiques prévisibles de fonctionnement et d'environnement
de la machine à laquelle il doit être fixé.
A intervalles réguliers durant la vie de la machine, vérifiez si les
caractéristiques prévues sont toujours valables et inspectez de l'appareil afin
de détecter toute détérioration accélérée, toute dégradation du matériel ou
manipulation frauduleuse. Si nécessaire, remplacez l'appareil. Guardmaster
n'est pas responsable d'un défaut de l'appareil si la procédure décrite dans
cette notice n'a pas été appliquée ou si le l'appareil est utilisé sans tenir
compte des recommandations.
L'interrupteur ne doit pas être utilisé comme un arrêt mécanique.
Les butées de porte et les dispositifs de guidage doivent être fixés.
Evitez l'exposition aux chocs et/ou aux vibrations dépassant les limites
données dans la norme CEI 68 paragraphe 2-6/8.
Suivre rigoureusement les instructions de maintenance pour valider la
garantie constructeur.
(a2) REPAIR
If there is any malfunction or damage, no attempts should be made
to repair it. The switch should be replaced before machine operation
is allowed.
DO NOT DISMANTLE THE UNIT.
Falls Fehlfunktionen oder Schäden auftreten, keine Versuche zur
Reparatur unternehmen. Der Schalter muß ersetzt werden, bevor die
Maschine wieder gestartet wird.
GERÄT DARF NIEMALS GEÖFFNEN WERDEN!
REPARATUR
Declaration of Conformity / Konformitätserklärung / Déclaration de conformité (b2)
This is to declare that the Guardmaster Trojan T15 conforms with the Essential Health & Safety Requirements (EHSR's) of the European Machinery Directive
(98/37/EC), the relevant requirements of the Low Voltage Directive (73/23/EEC as amended by 93/68 EEC). The Trojan T15 also conforms to EN 1088, EN
60947-5-1, EN 292, EN 60204-1 and is Third Party Approved by U.L. and TUV.
Signed for EJA Limited (Guardmaster)
S. F. Mitchell
Deputy Managing Director
RÉPARATION
En cas de dysfonctionnement ou de dégradation, ne pas attendre
pour réparer. L'interrupteur doit être remplacé immédiatement avant
le démarrage de la machine.
DANS TOUS LES CAS, NE DISLOQUEZ PAS L'APPAREIL.
ISO 9001
FM 21701
EJA Ltd. (Guardmaster)
Hindley Green Ind. Est. Wigan, England WN2 4HR
Tel: 01942 255166 (Int: +441942 255166)
Fax: 01942 523259 (Int: +44 1942 523259)
Web site: www.guardmaster.co.uk
Guardmaster Sicherheitstechnik GMBH.
Am Stadion 15, 42897 Remscheid, Germany
Telefon: (02191) 96850 Telefax: (02191) 968520
Guardmaster Sarl
EUROCAP/COURTIMMO, 62231 COQUELLES, France
Téléphone : 03 21 00 73 74 - Télécopie : 03 21 00 12 34
Site internet France : http://www.guardmaster.fr
E-mail : directinfo@guardmaster.fr
Drg No: 11849 / Issue No:2
Deutch / Français
DEUTSCH
(c)
Konfigurieren Sie die Verschlußkappe
entsprechend der erforderlichen Einbaulage
des Betätigereingangs. Stellen Sie sicher,
daß der Betätiger vor dem Drehen der
Verschlußkappe entfernt wird.
(d) Resistorx Sicherheitsschrauben
(e) Führen Sie den Staubschutzkappe in den
unbenutzten Schlitz ein.
(f) Schutzgittersperre
(g) Mindestbetriebsradius R 175 mm mit dem
Standardbetätiger (60 mm mit dem
flexiblen/einstellbaren Betätiger)
(g1) Legen Sie zur Verhinderung einer
Schalterbewegung während des Betriebs
den Paßstift ein.
(h) Beachtung: Beilegscheiben müssen unter
die Schalterhalteschrauben gelegt werden
FRANCAIS
(c) Configurez l’entrée de la broche. Assurez
vous du retrait de la broche avant de faire
pivoter la tête de sécurité.
(d) Vis de sécurité Resistorx
(e) Boucher la fente non utilisée.
(f) Butée de porte
(g) Rayon minimum de fonctionnement
175mm avec une broche standard
(60 mm avec une broche flexible/réglable)
(g1)Fixez des chevilles pour éviter que
l'interrupteur ne bouge pendant le
fonctionnement.
(h) Note: Les boulons de fixation du
commutateur doivent être munis d'une
rondelle
1
(c)
Configure end cap for required actuator entry. Ensure actuator is removed before rotating end cap.
3
2
A
1
C
(h)
2
Note: The switch mounting bolts must be fitted with washers
4
(d)
Resistorx security screws
2mm
(f) GUARD STOP
2 x M5 - 2 Nm
(e)
Fit plug into
unused slot
0.55 Nm
5
180°
(g1)
Fit dowel pins to
prevent switch movement
during service
7
D
6
B
R
R
R
R
(g) Minimum Operating radius R
175mm with standard actuator
(60 mm with Flexible/Adjustable Actuator)
DEUTSCH
(j) Anschlußdetails
(k) HINWEIS: Die Verwendung von
Kabelstutzen zur Beibehaltung der IP
Schutzart wird empfohlen.
(m) Hilfsstromkreis (Schließer)
(n) Sicherheitsstromkreis (Öffner)
(p) Sicherheitsstromkreis (Öffner)
( r) Schwarz/Schwarz
N/C Sicherheitsstromkreis 2
(s) Blau/Braun
N/C Sicherheitsstromkreis 1
(t) Anwendungsbeispiele
(u) Start Druckknopftaster
(v) Stop Druckknopftaster
(w) Schutzgitter geschlossen
(x) Trojan Verriegelungsschalter
(y) Minotaur MSR6R/T eingestellt auf D
Kanal, eingestellt auf Betriebsart R
(z) Druckknopftaster für Neueinstellung
(a1) Kontaktschutz d.h. Wärmeausschaltung
(b1) Sicherungen
(c1) Hilfskreis (Alarm oder Anzeige)
(d1) Jedes Mal wenn die verriegelte
Schutzgittertür offen ist, prüfen, ob
Maschine isoliert und abgeschaltet ist.
WICHTIG: Nach Montage und
Inbetriebnahme sollten Betätiger,
Schalter u. Befestigungsschrauben für
Schalterdeckel zum Aufzeigen von
Eingriffen mit Lack oder ähnlichem
Material beschichtet werden.
(e1) Wahlweise Verschluß und Halterung,
Bestellnr. 11094
(g1) Wahlweise flexibler/einstellbarer
Betätiger und Führung,
Bestellnr. 27010
FRANCAIS
(j) Détail des connexions
(k) NOTE : Il faut utiliser des presse-
étoupes afin de maintenir l’indice de
protection
(m) Circuit auxiliaire (N/O) = 23/24
(n) Circuit de sécurité 2 (N/C) = 21/22
(p) Circuit de sécurité 1 (N/C)
(r ) Noir/ noir, circuit de sécurité 2 N/C
(s) Bleu/marron. circuit de sécurité 1 N/C
(t) Exemples d'application
(u) Bouton poussoir de marche
(v) Bouton poussoir d'arrêt
(w) Porte fermée
(x) Commutateur de verrouillage Trojan
(y) Minotaur MSR6R/T réglé sur le canal D
et réglé sur le mode R
(z) Bouton poussoir de remise à zéro
(a1) Protection de contact e.g. coupe-circuit
thermique
(b1) Fusibles
(c1) Circuit auxiliaire (alarme ou indication)
(d1) Vérifiez que la machine soit arrêtée et
coupée lorsque la porte est ouverte.
IMPORTANT : Après l'installation et les
essais de mise en service, recouvrir de
vernis de blocage les vis de fixation de
la broche, de l’interrupteur et les vis du
couvercle.
(e1) Kit de maintien en option
Pièce No: 11094
(f1) Force de fixation = 5ON
(g1) Broche flexible / réglable et dispositif
de guidage en option
Pièce No: 27010
3
(j) Connection details Brad Harrison connection
4 pole male, Type: BG 16881-008
M20 / Pg 11
(k)
NOTE: Cable glands
should be used to
maintain IP rating.
24VAC/DC, 110VAC, 230VAC
GUARD
CLOSED (w)
(m)
2324
Auxiliary
Circuit (N/O)
(p)
1112
Safety
Circuit 1 (N/C)
1 N/C + 1 N/O version 2 N/C version
(t) Application examples
2221
1211
2221
1211
MINOTAUR
Guardmaster
(u) START
K1 (AUX)
MOMENTARY
PUSH
BUTTON
K2 (AUX)
(v) STOP
MOMENTARY
PUSH
BUTTON
(x )TROJAN
21
11
INTERLOCK
SWITCH
22
12
(y) MINOTAUR
SET TO D CHANNEL
MSR6R/T
SET TO R MODE
A1 S13 S23 33X1 41 13 23
A2 S14 S24 34X2 42 14 24
(b1) FUSES
(z) RESET
MOMENTARY
PUSH
BUTTON
22
K1
K2
21
1112
L1 L2 L3
M
(a1) CONTACT
PROTECTION
E.G. THERMAL
CUT OUT
(n)
Safety
Circuit 2 (N/C)
(p)
Safety
Circuit 1 (N/C)
1211
4
(d1) Check the machine is isolated and stopped
whenever the interlocked guard door is open.
IMPORTANT: After installation and commissioning,
(p) Safety Circuit 1 (N/C)
12 11
1
2
3
4
(m) Auxiliary Circuit (N/O) = 23/24
(n) Safety Circuit 2 (N/C) = 21/22
2423
1211
2423
Relay
N/O, N/C
monitoring
MINOTAUR
unit
the actuator, switch and switch lid fixing screws
K1 K2
should be coated with tamper evident varnish or
similar compound.
(ALARM OR INDICATION)
(c1) AUXILIARY CIRCUIT
5
(e1) Optional catch and retainer
Part No: 11094
(f1) HOLDING
FORCE = 50N
6
(g1) Optional flexible/adjustable actuator and guide
Part No: 27010
M12
7.25
1.5
(s1) CATCH RETAINER
55.5
40
MIN.R 175mm
52
40
14.5
25.5
46.5
8.5
14
15.5
M5
Deutsch / Français
(h1) Endeingang / Entrée arrière
(j1) Betätiger / Broche
(k1) Vordereingang / Entrée avant
(m1) Befestigungslöcher für M5 Csk Schrauben /
Trous de fixation pour les vis M5 CSK
(n1) Befestigungslöcher für M5 Schrauben /
Trous de fixation pour les vis M5
(p1) Betätiger-Ausziehabstand vom kompletten Einschieben:
Typ ÖVS (Öffner-vor-Schließer Kontakte)
Kontakt offen, Kontakt geschlossen /
Distance de retrait de la broche à partir d'une insertion
totale : type ouvrir avant de fermer les contacts
Contact ouvert, Contact fermé
21/2322/24
(q1) Betätiger-Ausziehabstand vom kompletten Einschieben:
Typ SVÖ (Schließer-vor-Öffner Kontakte)
Kontakt offen, Kontakt geschlossen /
Distance de retrait de broche à partir d'une insertion totale
: type fermer avant d'ouvrir les contacts
Contact ouvert, Contact fermé
(r1) Verschlußgehäuse / Boîtier de maintien
(s1) Verschlußhalterung / rochet de maintien
(t1) Flexibler/ Einstellbarer Betätiger & Führung / Actionneur
flexible/réglable et dispositif de guidage
Mindestbetriebsradius Vordereingang (Standardbetätiger)
/ Rayon de fonctionnement minimum de l'entrée avant
(broche standard)
Mindestbetriebsradius Endeingang (Standardbetätiger) /
Rayon de fonctionnement minimum de l'entrée arrière
(broche standard)
Flexibler Betätiger / broche flexible
MIN.R 60mm
(w1)
Technical Specifications
Approvals TUV, cULus
Conforming to standards EN 60947-5-1, EN 1088, EN 292, EN
60204-1
Safety contacts 2N/C or 1N/C direct opening
Utilisation category AC 15
AC (Ue) 500 V 250 V 100 V
(le) 1 A 2 A 5 A
DC 250 V 0.5 A, 24 V 2 A
Max. switched current/voltage/load 500 V/500 VA
Thermal current (lth) 10 A
Minimum current 5 V, 5 mA DC
Safety contact gap >2 x 2mm
Rtd insulation voltage (Ui) 500 V
Rtd impulse withstand voltage (Uimp) 2500 V
Auxiliary contacts 1N/O (only with 1N/C safety version)
Pollution degree 3
Actuator travel for positive opening 6 mm
Minimum operating radius 175 mm (60 mm with flexible actuator)
Break contact min. force 30 N
Max. actuation speed 160 mm/s
Max. actuation frequency 2 cycle/s
Case material UL approved glass-filled polybutylene
terephthalate (PBT)
Actuator material Stainless steel
Protection IP67
Conduit entry 3 x M20 or 3 x Pg 11
Operating temperature -20°C to +80°C
Fixing 2 x M5
Mounting Any position
Mechanical life 1 x 10
Electrical life 1 x 10
Weight 120 g
Colour Red
Cleaning May be steam cleaned
Note: The safety contacts of the Guardmaster switches are described as
normally closed (N/C) i.e. with the guard closed, actuator in place (where
relevant) and the machine able to be started.
32
14.5
(q1)
Actuator withdrawal distance
from full insertion
11/12
21/22
Contact Open
6
6
15
3.5
15 10 6
16
FIXING HOLES FOR
(m1)
M5 CSK SCREWS
Contact Closed
13
33.4
41
75
17.5
(j1) ACTUATOR
31.2
5
40
52
0mm20
(n1) FIXING HOLES
FOR M5 SCREWS
(p1)
Actuator withdrawal distance
from full insertion: type BBM
(Break Before Make Contacts)
15 10 6
11/12
23/24
Contact Open
6.5
Contact Closed
Technische Daten
Zulassungen TUV, cULus
Entspricht Normen: EN 60947-5-1, EN 1088, EN 292, EN
Sicherheitskontakt 2N/C or 1N/C direkt öffnender
Verwendungskategorie AC 15
AC (Ue) 500 V 250 V 100 V
(le) 1 A 2 A 5 A
DC 250 V 0.5 A, 24 V 2 A
Max.Einschaltstrom/Sp./Belstg. 500 V/500 VA
Thermischer Strom (lth) 10 A
Mindeststrom 5 V, 5 mA DC
Sicherheitskontaktlücke >2 x 2mm
Nennisolationsspannung (Ui) 500 N
Nennsteh-Stoßspannung (Uimp) 2500 N
Hilfskontakte 1N/O (nur mit 1 Öffner, Schutzversion)
Verunreinigungsgrad 3
Zwangsöffnungsweg d. Betätigers 6 mm
Min. Betriebsradius 175 mm (60 mm mit flexiblem Betätiger)
Min.kraft zur Kontaktunterbr. 30 N
Max. Betätigergeschwindigkeit 160 mm/s
Max. Betätigerfrequenz 2 Zyklen/Sek.
Gehäusematerial UL-zugelassenes Glasfaserpolybutylen-
Betätigermaterial Edelstahl
Schutzart IP67
Rohrleitungseingang 3 x M20 or 3 x Pg 11
Betriebstemperatur -20°C to +80°C
Befestigung 2 x M5
Montage jede Stellung
Mech. Lebensdauer 1 x 10
Elektr. Lebensdauer 1 x 10
Gewicht 120 g
Farbe rot
Reinigung mögl. Reinigung mit Hochdruckdampf
Hinweis: Die Sicherheitskontakte der Guardmaster Schalter werden als Öffner
beschrieben, d.h. das Schutzgitter ist geschlossen, der Betätiger angebracht (wo
erforderlich) und die Maschine kann gestartet werden.
(h1) END ENTRY
5
31
5.5
0mm20
20.5 15.75
(k1)
FRONT ENTRY
2 x M3
20.5 40
5.5
5
Minimum Operating Radius Front-Entry (Standard Actuator)
MIN.R 175mm
Flexible Actuator MIN.R 60mm
Semi flexible actuator MIN.R 175mm
CTRS
52
6.8
(t1) FLEXIBLE/ADJUSTABLE ACTUATOR & GUIDE SEMI FLEXIBLE ACTUATOR & GUIDE
MIN.R 175mm
Flexible Actuator MIN.R 60mm
Semi flexible actuator MIN.R 60mm
18
4 x Ø5.5
31
40
52
52
(r1) CATCH CASE
51
19
13
8
20
29
184
11.2
35
29.0
20.7
32.7
52.0
20.7
32.7
Minimum Operating Radius End-Entry (Standard Actuator)
MIN.R 175mm
Flexible Actuator MIN.R 60mm
Semi flexible actuator MIN.R 60mm
Flexible Actuator MIN.R 60mm
Semi flexible actuator MIN.R 175mm
Specifications techniques
Homologations TUV, cULus
60204-1
Terephthalat (PBT)
6
6
Conforme aux normes EN 60947-5-1, EN 1088, EN 292, EN
Contact de sécurité 2N/C or 1N/C ouverture directe
Utilisation category a.c. 15
a.c (Ue) 500 V 250 V 100 V
(le) 1 A 2 A 5 A
d.c 250 V 0.5 A, 24 V 2 A
Courant/tension/charge max. 500 V/500 VA
Courant thermique (lth) 10 A
Courant min. 5 V, 5 mA DC
Espace contact de sécurité >2 x 2mm
Tension d'isolement (Ui) 500 V
Tension de tenue aux ondes de choc (Uimp) 2500 V
Contacts auxiliaires 1N/O (uniquement avec 1 N/C version sécurité)
Degré de pollution 3
Parcours de l'actionneur pour
ouverture positive 6 mm
Rayon minimum de fonctionnement 175 mm (60 mm avec actionneur flexible)
Force minimum rupture contact 30 N
Vitesse max de la commande 160 mm/s
Fréquence max de la commande 2 cycles/seconde
Boîtier Polybutylène-téréphtalate armé à la fibre
Matériel de l'actionneur acier inoxydable
Protection IP67
Presse-étoupe 3 x M20 ou 3 x Pg 11
Température -20°C á +80°C
Fixation 2 x M5
Montage N'importe quelle position
Vie mécanique 1 x 10
Vie électrique 1 x 10
Poids 120 g
Couleur Rouge
Nettoyage
Note : Les contacts de sécurité des interrupteurs Guardmaster sont décrits
comme étant normalement fermés (N/C) i.e. avec la porte fermée,
60204-1
de verre homologué UL
6
6
Peut être nettoyé à la vapeur haute pression
l'actionneur en place (où il a lieu d'être) et la machine prête à fonctionner.
INFORMATION IN REGARD TO UL508
When used in elevated ambients, temperature rating of field wiring shall
not be less than ambient.
Electrical spec of rating code A600.
Max current: 120V AC - make 60A, break 6A.
240V AC - make 30A, break 3A.
Max. V/A: make 7200, break 720.
Use copper conductors only.
Use polymeric conduit only.
End of line device.
Terminal tightening torque 9in/lbs.
INFORMATION ZU UL508
Beim Einsatz bei hoher Umgebungstemperatur dürfen die Temperaturwerte der
Feldleitung nicht geringer als die der Umgebungstemperatur sein.
Elektrischer Bemessungscode A600
Max. Spannung: 120 V AC - Einschaltstrom 60 A, Ausschaltstrom 6A
240 V AC - Einschaltstrom 30A, Ausschaltstrom 3A
Max. V/A: Einschaltleistung 7200, Ausschaltleistung 720
Verwenden Sie nur Kupferdrähte
Verwenden Sie nur Polymerleitungsdrähte
Zeilenendgerät
Einrastdrehmoment für Klemmen
9in/lbs.
INFORMATION RELATIVE A UL508
En cas d'utilisation dans des températures élevées, veillez à ce que la
température des conducteurs électriques ne soit pas inférieure à la
température ambiante.
Produits électriques spéciaux de code de classement A 600.
Courant max : 120V AC - pour fermer 60A, pour ouvrir 6A.
240V AC - pour fermer 30A, pour ouvrir 3A.
V/A max. : pour fermer 7200, pour ouvrir 720.
N'utilisez que des conducteurs en cuivre.
N'utilisez qu'un conduit polymère.
Fin du dispositif de ligne.
Force de torsion terminale 9in/Ibs.