Rockwell Automation 42JT-C2LAT1-A2, 42JT-C2LAT1-P4, 42JT-C2LAT1-F4, 42JT-C2LAT1-Y4 Installation Instructions Manual

Page 1
Installation Instructions
IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.
Yel low LED
Pushbutton
Green LED
42JT VisiSight™ Photoelectric Clear Object Sensors with IO-Link
Default Settings:
Output Mode: Dark Operate (Output ON when the light between
sensor and reflector is blocked) Output Type: Auto PNP/NPN or IO-Link. In Auto PNP/NPN mode, the sensor continuously monitors the load connection and automatically configures the output to PNP or NPN.
Sensor User Interface
LED Status
The table below provides LED status in the RUN mode. During operation, the sensor is always in RUN mode, except when being taught.
Auto PNP/NPN Operation
OFF Power is OFF
Green
Yel l ow
IO-Link Operation
ON Power is ON
Flashing (6 Hz) Unstable light level (0.5 < margin < 2)
Flashing (1.5 Hz) Output short circuit protection active
OFF Output de-energized
ON Output energized
General Specifications
42JT-C2LAT1-
Environmental
Certifications cULus and CE Marked for all applicable directives Operating Environment IP67, IP69K, ECOLAB Operating Temperature [C (F)] -20…+60° (-4…+140°) Storage Temperature [C (F)] -20…+80° (-4…+179°)
Optical
Light Source Visible red 660 nm Sensing Range 0…2 m (0…6.6 ft) Adjustments Push button
Electrical
Voltage 10…30V DC Current Cons umption 30 mA max . Sensor Protection Reverse polarity, short circuit protection
Outputs
Response Time 0.5 ms Output Type Auto NPN or PNP Output Function Selectable light operate or dark operate Output Current 100 mA max. Output Leakage Current 10 μA max.
Mechanical
Housing Material ABS Lens Material PMMA Cover Material PMMA Optional Accessories Mounting brackets, cordsets
See Connection Types table.ECOLAB on P4 and A2 models onlyUL: -20…+50°C (-4…122°F)
UL: Class 2 source
Green
Yel l ow
OFF Power is OFF
Flashing (1 Hz) Power is ON
OFF Output de-energized
ON Output energized
Connection Types
Cat. No. Suffix Description
-A2 2 m cable (PUR)
-P4 Integral 4-pin pico (M8) QD
-F4 4-pin DC micro (M12) QD on 150 mm (6in.) pigtail
-Y4 4-pin pico (M8) QD on 150 mm (6 in.) pigtail
Page 2
Mounting the Sensor
t > 3 s
Reflector
Reflector
t > 6 s
Securely mount the sensor on a firm, stable surface or support. An application which is subject to excessive vibration or shifting may cause intermittent operation. For installation convenience, Rockwell Automation offers a wide range of mounting brackets (see the Accessories section for more details).
Alignment Indication
For short range applications the visible light beam of the sensor suffices as alignment aid.
The alignment feature may be used for longer range applications. Alignment of the sensor is indicated by a change in intensity of the green LED in the Alignment Mode, as follows:
1. Press and release the push button twice within three seconds. After three seconds, the green LED turns OFF for 0.5 second, indicating that the sensor is in the alignment mode.
2. Align the sensor to the reflector. The intensity of green LED increases with better alignment. Secure it in the position that yields the highest intensity of the green LED. Press and release the button once to return to the RUN mode—or the sensor returns to the RUN mode automatically in two minutes.
VisiSight™ Configuration
The 42JT VisiSight is configured using the push button, Remote Teach, or via IO-Link and the LED indicators on the sensor. The five following features can be configured:
• Static Teach: Standard or Precision Teach for sensitivity/
sensing range
• Dynamic Teach (running process)
• Light operate (LO) or dark operate (DO) output
• Auto PNP/NPN, dedicated NPN or dedicated PNP
• Push button lock/unlock
The sensor output is disabled during Teach.
Teach Sensitivity/Sensing Range
The default setting is the maximum range.
Static Teach:
Teaching the sensitivity/sensing range is a two step process: teach the reflector (first condition) and teach “target” (second condition.
Standard Teach:
1. Teach the reflector (first condition)
2. Teach target (second condition):
t < 0.5 s
Position the clearest target to be detected between the sensor and the reflector. Press and release the button. The teach process is complete.
If the push button is not pressed within 30 seconds, the sensor exits the teaching mode and returns to RUN mode without learning a new setting.
The sensor can also be taught by teaching the target as the first condition and the reflector as the second condition.
Precision Teach:
A precision teach can be performed by teaching the reflector as both the first and second condition, i.e. clear target is not taught. This sets the sensor to its highest sensitivity to detect very clear targets. Under this setting, a small change in signal received will switch the output.
Restore to factory default setting of maximum range:
Perform steps 1 and 2 with no reflector and no target in the sensor field of view.
Dynamic Teach (Running Process):
If the targets to be detected are moving with the sensor aimed at the running process, press and hold the button for three seconds until the yellow LED starts flashing. The sensitivity will automatically be taught in the next 30 seconds, provided the sensor sees two cycles of “target” and “no target.”
Teach Light Operate (LO) or Dark Operate (DO)
The default setting of the output is Dark Operate (DO). DO setting means that the output turns ON when the target is
detected. If the application requires the output to turn OFF when the target is detected, the setting may be changed to Light Operate (LO).
1. To access the teach output mode setting:
Press and hold button for six seconds until green LED starts flashing. Release the button. The current setting is indicated by the yellow LED: LO: Yell ow LED ON DO: Yellow LED OFF
Align the sensor to the reflector. Press and hold button for three seconds until the yellow LED starts flashing. Release the button. The first condition has now been taught.
2
2. To change the sensor output mode setting:
t < 0.5 s
Press and release the button within ten seconds to toggle—from LO to DO—the selection indicated by the yellow LED.
The sensor retains the setting configured by the last button activation and returns to the RUN mode ten seconds after the last button is depressed.
Page 3
Output Type Selection:
4
3
1
2
3
2
1
4
M12 Male M8 Male
Brown (1) White (2) Black (4) Blue (3)
+V Remote Teach/Lock Output (Auto PNP/NPN or IO-Link)
-V
LO DO
Clearance for
M3 or #4-40 screw
(2 places)
Clearance for
M3 or #4-40 screw
(2 places)
Auto PNP/NPN, Dedicated NPN, Dedicated PNP)
The default setting is Auto PNP/NPN. This means the sensor monitors the load connection and automatically configures for the proper operation, namely PNP or NPN. If no load is connected, the sensor defaults to PNP.
The following applications are covered with dedicated PNP or dedicated NPN selection:
a. Parallel wiring of multiple sensor outputs: select dedicated
PNP or dedicated NPN setting, as needed.
b. If the load is connected for NPN configuration but to a
different power supply than the power to the sensor or via a load enabling contact (e.g., a relay contact in series with the load): select dedicated NPN.
Perform a selection as follows:
1. To access output type: Press and hold the push button for 12 seconds (until both LEDs start flashing synchronously). Upon button release, the current setting of output type is indicated by the slow flashing of the LED (or LEDs) as follows:
• Auto PNP/NPN: both LEDs flashing
• Dedicated NPN: green LED flashing
• Dedicated PNP: yellow LED flashing
2. To change output type: Press and release the push button within ten seconds to select desired type. Each activation of the button will cycle to the next output setting. The type selected is indicated by the LEDs. The sensor retains the setting configured by the last button activation and returns to the RUN mode ten seconds after the last button is pressed.
Push Button Lock/Unlock
The push button or remote teach (RT) can be used to prevent unauthorized users from changing teach settings.
To lock the push button: press and release the button three times within three seconds. Both LEDs flash synchronously for three seconds, indicating that the push button is now locked.
To unlock the push button: press and release the button three times within three seconds. Both LEDs flash asynchronously for three seconds, indicating that the push button is now unlocked.
Permanent Lock: The push button may be permanently locked by connecting the white wire (pin 2) to –V.
Remote Teach (RT)
The sensor can be taught remotely via the white wire (pin 2). Connection to +V produces the same result as a button activation, while no connection is equivalent to not pressing the button. The sensor can be taught by following the same teach/timing sequence as used in the push button teach. For example, connect to the +V for more than three seconds to align and install the reflector, disconnect from the +V; while the reflector is in the sensor field of view and there is no target, connect to the +V for less than one second to complete the teach process. All push button functions can also be carried out via RT.
IO-Link
See instructions for IO-Link on www.ab.com/literature. Remote Teach (pin 2) is disabled in IO-Link operation. If output is selected as dedicated NPN, IO-Link communication is unavailable.
3
Wiring Diagrams
The following diagrams show the quick-disconnect connector. The pin numbers correspond to male connectors on the sensor.
Micro (M12) Male QD on Pigtail and Integral Pico (M8) Male QD
Output Wiring
Normal operation: no connection (disabled in IO-Link operation).
Remote Teach: connect to +V. Refer to the Remote Teach section. Push Button Lock: connect to -V. Refer to the Push Button Lock/
Unlock section.
Approximate Dimensions [mm (in.)]
12
(0.47)
34
(1.34)
2.8
(0.11)
12
(0.47)
34
(1.34)
M8 x 1
20
(0.79)
22.9
(0.90)
25.4 (1.0)
2.6
(0.10)
20
(0.79)
22.9
(0.90)
25.4 (1.0)
2.6
(0.10)
Page 4
Rockwell Automation maintains current product enviro nmental informatio n on its website at
http: //www. rockwell automation .com/ro ckwe ll automation/ab out- us/susta inab il ity-ethi cs /produc t- environmental- compli ance.page
.
Spot Size
0 0.2
(0.66)
0.4
(1.31)
0.6
(1.97)
0.8
(2.62)
1.0
(3.28)
0
10
20
30
40
Size [mm]*
Distance [m (ft)]
12
(0.47)
18.6
(0.73)
33
(1.3)
14
(0.55)
24
(0.95)
8 (0.32)
15
°
R 25.4 (R 1.0)
30°
20°
63.5 (2.5)
8
(0.32)
14
(0.55)
R 25.4
(1.0)
12
(0.47)
18.6
(0.73)
33
(1.3)
10°
3.8
(0.1496)
20
(0.79)
20
(0.79)
26
(1.02)
32
(1.26)
3
(0.118)
3.7
(0.146) dia.
Reflectors
92-118 Micro cube reflector
7.0
(0.28)
51.0 (2.01)
38.0 (1.50)
* The spot size is square in shape with one side dimension per the graph.
Linear increase in spot size to 2 meters.
Accessories
Stainless Steel Mounting Brackets
60-BJS-L1
40.0
(1.58)
51.0
(2.01)
60.7
(2.39)
4.3 (0.17)
10 (0.39)
3.5
20 (0.79)
(0.14)
92-134 Micro cube reflector
This reflector can be used if a smaller size reflector is preferred and the reflector is mounted within 1 m (3.28 ft) of the sensor.
60-BJT-L2
60-2619 VisiSight-compatible swivel/tilt mounting bracket