Installation Instructions
Power Terminal Block
(Catalog Number 2711-TBDC, 2711P-RVAC)
These document provides instructions on how to remove and install
the DC or AC Power Terminal Block in the following devices:
Cat. No. Power Type Terminal Type
2711-TBDC DC PanelView 300 Micro
PanelView 600 Touch only
PanelView Plus 400-600
2711P-RVAC AC PanelView Plus 400-600
Removing and Installing the
Power Terminal Block
You can remove and re-install the power terminal block for ease of
installation, wiring and maintenance. A terminal block is pre-installed
on each device when shipped.
WARNING
!
ATTENTION
Explosion Hazard
• Substitution of components may impair suitability
for hazardous locations.
• Do not disconnect equipment unless power has
been switched off and area is known to be
non-hazardous.
• Do not connect or disconnect components unless
power has been switched off.
• All wiring must comply with N.E.C. articles
501-4(b), 502-4(b), 503-3(b) as appropriate.
• Peripheral equipment must be suitable for the
location it is used in.
AC and DC terminal blocks are keyed and marked
differently so be sure to follow the markings. Do not
force terminal blocks into connectors to prevent
potential damage to terminal.
!
The procedure for removing and installing the power terminal block is
similar for all terminals. Orientation of the power terminal block may
vary between the terminals.
1 Publication 2711-IN021B-EN-P
To remove and install power terminal block:
ATTENTION
Disconnect all power before removing or installing
components. Failure to disconnect power may result
in electrical shock and/or damage to the terminal.
!
PanelView 300 Micro & 600 Touch Only
To remove terminal block:
1. Insert tip of small,
flat-blade, screw driver into
terminal block access slot.
2. Gently pry terminal block
away from terminal to release
locking mechanism
To install terminal block:
1. Press terminal block base in
first with block leaning outward.
2. Genty push top of terminal block back to
vertical position to snap in locking tab.
The location of the power terminal block on
the PV600 Touch terminal is different
but the procedure for removing and
installing the terminal block is the same.
PanelView Plus 400 - 600 Terminals
To remove terminal block:
1. Insert tip of small,
flat-blade, screw driver into
terminal block access slot.
2. Gently pry terminal block
away from terminal to release
locking mechanism
To install terminal block:
1. Press terminal block base in
first with block leaning outward.
2. Genty push top of terminal block back to
vertical position to snap in locking tab.
Publication 2711-IN021B-EN-P - July 2003 2 PN 41061-173-01(2)