Robertshaw 9710 User Manual

0 (0)
Maple Chase Company
2820 Thatcher Road
Downers Grove, Illinois 60515
United States of America
User’s Manual
Quick Start Installation and Programming
110-664
W
R
R
A
N
T
Y
7 Day Programmable 3 Heat / 2 Cool
INTEGRATED COMFORT SOLUTIONS
DELUXE PROGRAMMABLE THERMOSTAT
9710
®
ELECTRIC
E
GAS
G
110-664B
PRODUCT FEATURES
2
•Attractive, Styleline™ design
•4-pre-programmed set-points
• Energy Star compliant
•7-day programming; 4 setpoints per day
• QuickSet™ programming mode
• Autochangeover mode automatically switches system from heat to cool
•Programmable fan control
• Detachable sub-base allows you to remove mounted thermostat for easy, convenient programming.
• Energy Efficient Recovery (EER™) mode for maximum savings.
• Filter monitor notifies when to change or clean furnace filter
•Programmable keypad lock prevents unauthorized re-programming
• NiteView™ LCD display backlight
•Programmable residual cooling fan delay for increased air conditioning efficiency
•Allows for up to 3 remote temperature sensors
•Visual and audible low battery signal
• High temperature protection
39
FIVE YEAR LIMITED WARRANTY
Maple Chase Company warrants to the original contractor installer or to the original consumer user, each new Robert Shaw thermostat to be free from defects in materials and workmanship under normal use and service for a period of five (5) years from the date of purchase.
This warranty does not cover batteries, damage caused by batteries, damage resulting from improper installation, alteration, misuse or abuse of the thermostat occurring after the date of purchase.
Maple Chase Company agrees to repair or replace at its option any thermostat under warranty provided it is returned within the warranty period, postage prepaid, with proof of the date of purchase. Cost of thermostat removal or reinstallation is not the responsibility of Maple Chase Company.
Repair or replacement as provided under this warranty is the exclusive remedy of the consumer. This warranty and our liability does not apply to batteries on the merchandise that has been damaged caused by misuse, neglect, mishandling, alterations, improper installation, or use in a way other than in accordance with Maple Chase Company’s recommendations and instructions. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose on this product is limited to the duration of this warranty.
Some states do not allow the exclusion or limitation of incidental or consequential damages, or allow limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Instructions for return:
Pack the thermostat carefully in a well-padded carton. Be sure to include a note describing, in detail, what is wrong with the product. Return, postage prepaid, to:
Uni-Line North America 515 South Promenade Ave., Corona, CA 91719, Attn: Warranty Department
As an EnergyStar Partner, Maple Chase has determined that this product meets the EnergyStar guidelines for energy efficiency.
T
E
S
MON
F
HEAT
PM
AUTO FAN
MANUAL
PROG/MAN
QUICKSET
LOCK
FILTER
M
E
T
S
Y
S
N
A
F
INSTALL
BYPASS
KEYPAD QUICK REFERENCE
3
SET - Begins, saves, and advances programming inputs
PROG/MAN - Sets thermostat to either program or manual mode. Provides quick return to normal operating mode from any menu
QUICKSET - Allows quick programming by enabling user to program all seven days at once
LOCK - Accesses keypad “lock” and “unlock” feature
FILTER - Accesses filter monitor and status
SYSTEM - Accesses 4 modes of operation: HEAT, COOL, AUTO (changeover), or system OFF
FAN -Accesses two modes of fan operation: auto and on
Decreases or reverses setting on display.
MAIN DISPLAY (OFF MODE)
A few seconds after power up or RESET, the display shown above will appear. The thermostat will be in OFF mode.
1. Press SYSTEM button to enter HEAT, COOL, or AUTO* (changeover) modes of operation.
2. Press PROG/MAN button to enter program or manual modes. Pressing PROG/MAN returns thermostat to main display from any menu.
*AUTO may only be entered if "AUTO CHG" was enabled during installation and you are in PROGRAM mode. (See "CHANGING DIP SWITCH SETTINGS.")
V
V
Increases or advances setting on display.
Symptom Remedy
Thermostat does not automatically Verify that thermostat is in PROGRAM mode and AUTO is indicated switch from HEAT to COOL mode of in the display for proper AUTO (changeover) operation. operation.
Auto (changeover) may have been disabled during installation. (See "SELECTING AUTO CHANGEOVER".)
Fan runs continuously for hours at Review programmable fan settings entered during programming. different times of the day (See "PROGRAMMING".)
Filter monitor indicates "CHECK FILTER" Check with your filter supplier and modify Filter Monitor settings to match too soon for proper filter servicing interval. your servicing intervals. (See "PROGRAMMING FILTER MONITOR".)
If problems with thermostat cannot be solved, call:
Te chnical Support: (800) 445-8299
Monday-Friday 7:30 - 5:30 Central Standard Time
If calling after hours, a 24-hour automated help line is available.
38
AUTO FAN
SET
PROG/MAN
QUICKSET
LOCK
FILTER
SYSTEM
FAN
The Robertshaw Model 9710 is compatible with 24V AC multi-stage gas, oil, or electric heating/cooling systems with up to 3 stage heat/2 stage cool. It will operate with multi-stage heating/cooling systems that are automatic or manual changeover.
This thermostat will automatically control the heating and/or air conditioning system. Once programmed, it will automatically adjust the temperature setting and fan operation at your programmed times. When used properly, this thermostat can reduce heating and cooling costs throughout the year.
TABLE OF CONTENTS
Product Features....................................2
KeyPad Quick Reference ......................3
Important Safety Information ..............5
Helpful Programming Tips ....................6
NiteView™ LCD Display Backlight ......8 Removing Thermostat from Wiring
Subbase ................................................9
Programming ......................................11
Set or Change Time, Day, etc............11
Selecting ˚F/˚C ....................................13
Program Overview ............................13
Programming with Quickset ............15
Review, Change, or Personalize ......17
Review or Modify Program ..............20 Energy Efficient Recovery (EER™) ..21
4
Programming Filter Monitor ............22
Checking Filter Monitor ....................22
Resetting Filter Monitor ....................22
Programming Keypad Lock ..............23
Unlocking Keypad ............................24
Operation ............................................25
Beginning Programmed
Operation. ..........................................25
Resetting Thermostat ........................26
Compressor Protection ....................26
Selecting Auto Changeover..............27
24V AC Circuit Power Monitor..........29
LED Indicator ....................................29
Changing Dip Switch Settings..........30
Replacing The Back-Up Batteries......31
Cleaning and Repair..............................33
Troubleshooting ....................................34
Warranty ................................................39
37
Symptom Remedy
System will not enter AUTO Thermostat must be in PROGRAM mode to run AUTO system operation. (Auto Changeover) mode. Press PROG/MAN button until PROGRAM is indicated in display. Then,
press SYSTEM button until AUTO is indicated in display.
Room temperature reading is If you have attached remote sensors, the thermostat will display the inaccurate. average temperature of the activated sensors. See "INSTALLATION
INSTRUCTIONS" and "CHANGING DIP SWITCH SETTINGS".
If there are no remote sensors attached, make sure that the remote sensor dip switch settings on the rear of the thermostat body are turned off and the MAIN thermostat dip switch is turned on. See "CHANGING DIP SWITCH SETTINGS."
Thermostat will not let me change AUTO (changeover) mode may be active. See OPERATION - Selecting setpoint temperature above or below Changeover). AUTO will be indicated in display. a certain point.
Thermostat turns on system before my Energy Efficient Recovery (EER™) is in effect. This optional feature turns programmed setpoint time. on the system prior to the next setpoint time to reach the temperature you have programmed. See "PROGRAMMING" and “ENERGY EFFICIENT RECOVERY.”
"CHECK FILTER" is indicated in main display. See "PROGRAMMING - Programming Filter Monitor".
IMPORTANT SAFETY INFORMATION
WARNING:
Always turn off power at the main power source by unscrewing fuse or switching circuit breaker to the off position
before installing, removing, or cleaning this thermostat.
Read all of the information in this manual before programming this thermostat.This is a 24V AC low-voltage thermostat. Do not install on voltages higher than 30V AC.If you experience a loss of power this thermostat will indicate “-AC” in the time field of the LCD display. This
means that your system’s 24V AC circuit is not receiving power or is not functioning correctly. The back-up batteries provided in this thermostat will maintain the programming during the loss of power, however, the thermostat requires 24V AC power and a functioning system for proper control.
All wiring must conform to local and national building and electrical codes and ordinances.Do not short (jumper) across terminals on the gas valve or at the system control to test installation. This will
damage the thermostat and void the warranty.
This thermostat is equipped with automatic compressor protection to prevent potential damage due to short
cycling or extended power outages. The short cycle protection provides a 5-minute delay between heating or cooling cycles to prevent the compressor from being damaged.
Do not switch system to cool if the temperature is below 50°F (10°C). This can damage the cooling system and may
cause personal injury.
!
5
36
Symptom Remedy
Thermostat does not follow program. Check AM/PM indicators at time of day and programmed time changes.
(See “PROGRAMMING.”)
Thermostat may be OFF. Select HEAT or COOL mode by pressing SYSTEM button.
Program may not have been done in HEAT or COOL modes. (See "PROGRAMMING".)
Both HEAT and COOL programs utilize the same setpoint time and programmable fan settings. Only setpoint temperatures can be different. (See "PROGRAMMING".)
Check compatibility guide and system specifications. Thermostat in MANUAL mode. (See “OPERATION.”)
Thermostat may not have been programmed in HEAT or COOL position. Verify program. (See “PROGRAMMING – To Review or Change Program.”)
System runs too long. Temperature differential may be set too high. Decrease temperature
differential to lower setting, see "PROGRAMMING".
This thermostat is 24V AC powered and requires connection to both sides of the transformer for proper operation. It also
requires four charged “AA” ENERGIZER®brand batteries or equivalent alkaline batteries as a back-up source of power should the 24V AC circuit be interrupted temporarily due to a power outage. The battery back-up will maintain all program information during power outage.
Replace back-up batteries every year or when “LO BATT” indicator appears on the thermostat display.Use this thermostat only as described in this manual.
6
HELPFUL PROGRAMMING TIPS
Make sure the SYSTEM switch is in the HEAT or COOL position before programming.
The thermostat will not allow programming in AUTO or OFF modes.
Make sure you set the time of day (note AM/PM indicator) and day of week
accurately to ensure correct operation.
The program schedule has a winter (HEAT) and a summer (COOL) program. Both
schedules will use the same time and programmable fan settings, but can have different temperature settings. If you change the time or programmable fan setting in one program, the opposite program will change also.
Symptom Remedy
Heat turns on instead of cool and Check wiring and system specifications. vice versa.
Thermostat turns on and off too much. Increase temperature differential setting. (See “PROGRAMMING.”)
Display is indicating “LO BATT.” Replace back-up batteries soon. Be sure battery installation is correct.
(See “REPLACING THE BACK-UP BATTERIES.”)
Thermostat beeps once per minute Back-up batteries low. Change batteries immediately. (See "REPLACING and "LO BATT" is indicated in display. THE BACK-UP BATTERIES".)
LCD display is blank. Replace batteries to control system. (See "REPLACING THE BACK-UP
BATTERIES".)
Thermostat does not change when SYSTEM button is in OFF or is in AUTO (changeover) position. the ∨or ∧buttons are pressed.
Thermostat beeps and does not allow Autochangeover "deadband" conflict (See "SELECTING AUTO temperature changes when ∨or
CHANGEOVER".) or thermostat is locked.
buttons are pressed.
35
SYSTEM
Loading...