Rinnai Continuum HV Series 1, Continuum CONHV 330 I, Continuum CONHV 250E, Continuum CONHV 250 I, Continuum CONHV 330E Installation Instructions Manual

Page 1
Continuum
HV SERIES 1
Page 2
Important
This appliance shall be fitted in accordance with:
Local Gas fitting regulations.
Municipal Building codes.
AGA Gas installation Code AG601 – NZ 5261.
Any other relevant statutory regulation.
This appliance must only be installed, serviced and removed by an authorised
licensed person.
For service please contact 0800 RINNAI (0800 746624) for your closest service Centre.
This appliance must always have seismic restraints.
Installation
Positioning
The Rinnai Continuum should be positioned so there is access to any parts that may need servicing. It should be possible to remove the appliance at a later stage without altering the structure of the building. If the water heater is remotely fitted then it should be positioned as close to the unit as practicable to ensure minimum heat loss. The tank must always be restrained with seismic restraints as per NZ5261 and the local building codes. The Appliance should always be installed to the applicable codes and suggested siting positions can be found on the next page.
Temperature & pressure relief valves
The appliance is fitted with temperature and pressure relief valves that are rated for the Rinnai continuum (external model only). For remote usage the pressure and temperature relief valves should be sized and fitted according to the heat input of the Infinity water heaters. The relief should be as short as possible and grade continually to drain without restriction.
Cold water supply
The cold water inlet to the Rinnai Continuum should be a minimum of 150kPa and not exceed 500kPa. If the water pressure is in excess of 500kPa then a pressure reducing valve should be fitted. A stopcock, pressure limiting valve, line strainer, cold water expansion valve and non-return valve are required for all installations of the continuum.
Appliance connections
Primary flow and returns are 20mm-bsp female connections and the secondary flow and returns are 50mm-bsp female connections, which can be bushed down or capped as required. Both the hot water outlet on the top of the cylinder and cold water inlet are 50mm-bsp female connections.
Page 3
C
Positioning your Rinnai Continuum
A
B
Window
Door
D
A
F
E
A - 500mm minimum horizontally from an operable window, door, non-mechanical air inlet or any other opening into a building. B - 500mm minimum from any other flue terminal or combustion air intake. C - 300mm minimum below eaves, balconies or other projections. D - 1500mm minimum vertically below an operable window, non-mechanical air inlet or any other opening into a building. E - 500mm minimum from a return or external corner. F - 150mm minimum from a drain or soil pipe. G - 500mm minimum from an electricity meter or fuse box. H - 1000mm minimum from a gas meter, 1500mm from LPG gas bottles I - 500mm minimum from a neighbouring structure or obstruction facing the terminal
G
Flue
E
H
Meter
I
Power
3
Page 4
Pipe sizing
Cylinder location
External
Internal
External
Internal
Storage Capacity (litres)
250
250
330
330
Infinity model
Infinity 22 NG/LPG
Infinity 24 Input MJ
188
Infinity 24 Input kW
52
1st hour delivery at 50 degree rise
945
1017
2nd hour delivery at 50 degree rise
720
Continuous delivery at 50 degree rise
720
Cylinder recovery time at 50 Degree rise
2128Pump supplied
Yes
Thermostat supplied
Yes
Thermostat range
60-85 degrees
Water flow rates
1st Hour
Continuous
1st Hour
Continuous
Water flow at 40 degree rise
1125
900
1197
900
Water flow at 45 degree rise
1025
800
1097
800
Water flow at 50 degree rise
945
720
1017
720
Water flow at 55 degree rise
880
655
952
655
Water flow at 60 degree rise
825
600
897
600
Cylinder Construction
2205 Duplex Stainless Steel
Weight of Tank - dry (kg)
6576Weight of Tank - full (kg)
315
406
Diameter of Cylinder
560
610
Height of Cylinder
1540
1715
Maximum Cylinder Pressure (kPa)
850
Cold Water Pressure - min kPa
150
Cold Water Pressure - max kPa
500
TPR valves included
Yes
(external model only)
Power Supply (volts / amps)
230/10
Gas supply pressure
1.5 - 5.0 kPa
Gas connection to the Infinity
R3/4 20mm
water inlet to the cylinder
50mm
water outlet from the cylinder
50mm
Pipe sizing for both gas and water should be in accordance with NZ 5261
Power connection
The Rinnai Continuum requires a 230 volt 10 amp supply. This will be in the form of an approved external fitted waterproof electrical socket. This appliance must not be hard wired. The socket must be located not more than one metre from the appliance.
RINNAI CONTINUUM HV SERIES HOT WATER HEATING SYSTEMS
Model CONHV
250E
CONHV
250 I
CONHV
330E
CONHV
330 I
Options: Larger size cylinders can be supplied for specific applications
4
Page 5
Rinnai Continuum
Temperature / Pressure
Heater
Thermostat
Relief valve
Secondary Flow
Hot Water Outlet
Infinity Water
Infinity Flow
Secondary Return
Cold Water
Inlet
Gas Connection
Pump
Cylinder
Wiring Junction
Box
Page 6
560 mm (250L)
mm
610 mm (330L)
900 mm
1510 mm
1405
900 mm
mm
180mm270mm865
mm180
1715 mm (330)
1540 mm (250)
Page 7
L
NELNELLNE
Pump
Infinity
Junction box
Wiring diagram for Rinnai
Schematic diagram for Rinnai Continuum
N
ENE
Thermostat
L
Pump
Pump
Infinity
Thermostat
L
7
Page 8
Internal Rinnai
Continuum
Thermostat
Temperature / Pressure
Relief valve
Hot Water Outlet
Secondary Flow
Secondary Return
Cold Water
Inlet
Flow from external
Infinity
Cylinder
Return pipe to
external Infinity
Page 9
Warranty for the Rinnai Continuum Water Heating Systems.
The benefits conferred by this are in addition to all other rights and remedies in respect of the product, which you have under the Consumer guarantees Act or any other legislation. Given installation is in accordance with the manufactures specification, this appliance is warranted by Rinnai New Zealand for the cost of labour and components in the event of defects arising from faulty materials /or workmanship with the ensuing warranty conditions.
Installation
Your water heater installation must be in compliance with the Building Regulations and the Gas Appliance Installation Code NZS 5261.
Maintained in accordance with the instructions. Water quality remains within the quality standards listed in the Installation instructions.
Warranty Exclusions
The warranty does not cover damages caused by excess water pressure or any water damages caused by water leaks in the installation.
Warranty covers only the direct replacement of the faulty parts and excludes any part of the installation not supplied by Rinnai New Zealand.
Water Quality
Water that is outside the maximum recommended limits will void the warranty. If you are unsure of you water quality you need to consult your local water quality specialist.
Water Quality Table
pH 6.5 to 8.5 Totally dissolved solids up to 500 mg/litre Total hardness up to 150 mg/litre Chlorides up to 150 mg/litre Magnesium up to 7 mg/litre Calcium up to 15 mg/litre Sodium up to 125 mg/litre Iron up to 0.2 mg/litre
Item Domestic Commercial
Parts Labour Parts Labour
Cylinder 5 years 1 years 5 years 1 year Ancillary parts 1 year 1 year 1 year 1 year Infinity parts 3 years 3 year 1 year 1 year Infinity Heat Exchanger 10 years pro rata 3 years 1 year 1 year