Rinnai COMMON VENTING Miscellaneous Information

COMMON VENTING
Selection Guide
CVENT ACCESSORIES
Tankless Rack System
Configuraton
Type WH Qty. Rack Config. CV8IL3 CV8IL4 CV8IL5 CV8IL6 CV8IL7 CV8IL8 780037 790004 790001 790002 790003
3 03 1 1 2 1 1 1
4 02 + 02 1 1 2 1 1 1
Wall Mount
(TRW )
Type WH Qty. Rack Config. CV8IL3 CV8IL4 CV8IL5 CV8IL6 CV8IL7 CV8IL8 780037 790004 790001
Tankless
Rack System
Inline
(Freestanding)
TRS-IL
5 02 + 03 1 1 2 1 1 1
6 03 + 03 1 1 2 1 1 1
7 03 + 02 + 02 1 1 2 1 1 1
8 02 + 02 + 02 + 02
3 03 1 1 2 1 1 1
4 02 + 02 1 1 2 1 1 1
5 02 + 03 1 1 2 1 1 1
6 03 + 03 1 1 2 1 1 1
7 02 + 02 + 03 1 1 2 1 1 1
8 02 + 03 + 03
1 1 2 4 2 2 2
Cvent Header Kit
2 2 4 2 2 2
1* 1 2 1 1 1
1* 1 2 1 1 1
PVC
Adaptor
CVent Termination CVent Roof Flashing
Kits Required for up to 100 ft Equivalent
Type WH Qty. Rack Config. CV8BB3 CV8BB4 CV8BB5 CV8BB6 CV8BB7 CV8BB8 780037 790004 790001
3 03 1 1 2 1 1 1
4 04 1 1 2 1 1 1
Tankless Rack
System
Back to Back
IL = inline B to B = back to back
CVent Elbows Equivalent Lengths
45° = 3ft 90° = 6ft
5 05 1 1 2 1 1 1
6 06 1 1 2 1 1 1
7 03 + 04 1 1 2 1 1 1
8 04 + 04
* Option restricted to 41 ft. equivalent.
NOTE: All intake parts except the intake termination and PVC adapter are to be field supplied and are not provided by Rinnai. Order extensions and elbows as needed.
If spacing between water heaters is GREATER than 20.5” (center line to center line), the installer must purchase a vent extension and cut to the appropriate length. Refer to the manual for further instructions.
The length of each additional vent extension must be considered in the maximum allowable vent length.
2 2 4 2 2 2
1* 1 2 1 1 1
VENTING OPTIONS FOR THE TANKLESS RACK SYSTEM
Venting Options Exhaust Vent Material Intake Vent Material
Common Venting System PPtl (CVent) PPtl or PVC (eld-supplied) 8 8
Concentric PPs PVC 5 1 65 (NG) / 41 (LP)
Dual Pipe* (Centrotherm) PPs* PPs* or PVC 3 1 41
3 “ PVC / CPVC PVC or CPVC PVC or CPVC 3 1 65 (NG) / 41 (LP)
4 “ PVC / CPVC PVC or CPVC PVC or CPVC 4 1 100 (NG) / 65 (LP)
Diameter
(in)
Max
Units
Max Equivalent Vent Length (ft)
100 (with 7 TWH units or less)
41 (with 8 TWH units)