Rinnai HINRA35M, HINRA50M, HINRA70M, HINRA26M, HINRA80 Operation Manual

...
This appliance shall be installed in accordance with:
• Manufacturer’s Installation Instructions
• Current AS/NZS 3000
• Local Regulations and Municipal Building Codes including local OH&S requirements This appliance must be installed, maintained and removed by an Authorised Person. For continued safety of this appliance it must be installed and maintained accordance with the manufacturer’s instructions.
Remote Control Operation Manual
Australia Pty. Ltd.
ABN 74 005 138 769
Rinnai has a Service and Spare P arts network with personnel who are fu lly trained
and equipped to giv e the best service on your Rin nai appliance. If you r appliance
requires serv ice, please call our Nati onal Help Line. Rinnai r ecommends that this
appliance be serviced once a year.
Head Office
100 Atlantic Drive, Keysborough VIC 3173
P.O. Box 460 Braeside, Victoria 3195
Product Sales and Service - National Phone: 1300 555 545* Fax: 1300 555 655* Technical Helpline and Spare Parts National (Mon-Fri 8am - 5.30pm EST) Phone: 1300 555 545* Fax: 1300 300 141*
*Cost of a local call higher from mobile or public phones.
E-mail: enquiry@rinnai.com.au
For further information visit: www.rinnai.com.au
Part Number: B063803
December 2016
EQPL38586755
Issue A
cool
SET TEMP.
MODE
SWING
SWING
TURBO
SLEEP
SHORT
CUT
TIMER
ON
FAN
SPEED
LED
TIMER
OFF
LOCK RESET
ON/OFF
TEMP
- +
HINRA26M
HINRA35M
HINRA50M
HINRA70M
HINRA80
CIN050A
Wall Mounted Cassette
CIN070A
CIN100A
CIN120A
To Suit Models
CIN140A
1
CONTENTS
Use the remote control within a distance of 8 meters from the appliance, pointing it towards the receiver. Reception is confirmed by a beep.
Location of the remote contr ol.
8m
The remote control is powered by two AAA batteries housed under the removable rear cover. (1) Remove the cover by pressing and sliding off. (2) Remove the old batteries and insert the new batteries, placing the (+) and (-) ends correctly. (3) Reattach the cover by sliding it back into position.
NOTE: When the batteries are removed, the remote control erases all progra­mming. After inserting new batteries, the remote control must be reprogrammed.
Replacing Batteries
Handling the Remot e Control
CAUTIONS
The air conditioner will not operate if curtains, doors or other materials block the signals from the remote control to the indoor unit. Prevent any liquid from falling into the remote control. Do not expose the remote control to direct sunlight or heat. If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from falling on the receiver. If other electrical appliances react to the remote control, either move these appliances or consult your local dealer.
2
CAUTIONS
Do not mix old and new batteries or batteries of different types. Do not leave the batteries in the remote control if they are not going to be used for 2 or 3 months. Do not dispose batteries as unsorted municipal waste. Batteries can be taken to specialist waste transfer stations.
MODE
SWING
TEMP
SHORTCUT
FAN SPEED
TIMER OFF
RESET
LOCK
LED FOLLOW ME
TIMER ON
TURBO SELF CLEAN
DIRECT
SLEEP FRESH
2
3
5
7
8
8
8
9
9
10
Handling the Remote Control .........................................................
Remote Control Specifications......................................................
Function Buttons .................. .........................................................
Indicators on LCD ..........................................................................
System Operation ............................................................................
Auto Operation.................................................................................
Cooling/Heating/Fan Operation......................................................
Dehumidifying (DRY) Operation ......................................................
Adjusting Air Flow Direction ..........................................................
Timer Operation...............................................................................
Model
Rated Voltage
8m
3.0V( 2x AAA 1.5 Volt Batteries)
Remote Control Specifications
1. Operating Modes: AUTO, COOL, DRY, HEAT and FAN.
2. Timer Setting Function in 24 hours.
3. Indoor Setting Temperature Range : 17 C~30 C.
4. Full function LCD (Liquid Crystal Display).
Environment
Signal Receiving Range
Performance Features
3 4
RG36F5/BGEF
-5 C ~ 60 C
NOTE:
Remo te c on tr ol b utton d es ig n ma y be s light ly d if fe re nt from t he o ne
supp li ed d ep en ding on t he i nd iv id ual mod el
All th e fu nc ti on s descr ib ed a re a ss ociat ed w it h th e re lativ e in do or u ni t.
If the i nd oo r un it d oes not h av e a pa rt ic ular fe at ur e, t he re is no corr es po nd in g opera ti on p er fo rmed by t he i nd oo r un it.
1
2
4
5
3
9
10
8
6
7
11
12
13
14
15
TURBO SELF CLEAN
SLEEP
TIMER ON
TIMER OFF
LOCK
RESET
LED FOLLOW ME
FAN SPEED
SWING
MODE
TEMP
ON/OF F
SWING
Function Buttons
1
2
Each time the button is pressed, the operation mode is selected in a sequence as follows:
3
MODE Button
4
ON/OFF Button
Operation starts when this button is pressed and stops when this button is pressed again.
AUTO
COOL
DRY
HEAT FAN
Swing Button
Swing Button
Used to stop or start horizontal louver move­ment or set the desired up/down air flow direction. The louver changes 6 degree in angle for each press. If pressed for more than 2 seconds, the louver will swing up and down automatically.
Used to stop or start vertical louver movement and set the desired left/right air flow direction. The vertical louver changes 6 degree in angle for each press. And the temperature display area of indoor unit displays for one second. If pressed for more than 2 seconds, the vertical louver swing feature is activated. And the display area of indoor unit displays IIII , flashes four times, then the tempera­ture setting reverts back. If the vertical louver swing feature is stopped, it displays LC and remains on for 3 seconds.
,
,
,
,
,
,
SHORT CUT
5
SLEEP Button
NOTE: While in SLEEP mode, the SLEEP mode
is cancelled when the FAN or ON/OFF buttons are pressed.
Active/Disable sleep function. It maintains the most comfortable temperature and saves energy.
For details, see SLEEP operation in USER’S MANUAL.
6
Press this button to initiate the LED function. Press and hold this button for more than 2 seconds and the FOLLOW ME function is initiated. When the Follow Me function is activated, the remote display is actual temperature at its location. The remote control will send this signal to the air conditioner at 3 minute intervals until you press the FOLLOW ME button again. The Follow Me function is not available under DRY and FAN mode. Switching the operational mode or turning off the unit will cancel the FOLLOW ME function.
TURBO/SELF CLEAN Button:
5 6
Function Buttons
8
Press this button to decrease setting temper­ature or to decrease Hours during Timer setting.
UP Button ( ) Press this button to increase setting temper­ature or to increase Hours during Timer setting.
DOWN Button ( )
9
-
+
10
11
Used to select the fan speed in four steps: AUTO LOW MED HIGH
FAN SPEED Button
TIMER ON Button
12
Press this button to initiate the auto-on time sequence. Each press will increase the auto-timer setting in 30 minutes increments. When the setting time displays 10H, each press will increase the auto-timer setting 60 minutes increments. To cancel the auto-timer program, simply adjust the auto-on time to 0.0.
TIMER OFF Button
13
Press this button to initiate the auto-off time sequence. Each press will increase the auto-timed setting in 30 minutes increments. When the setting time displays 10H, each press will increase the auto-timer setting 60 minutes increments. To cancel the auto-timer program, simply adjust the auto-off time to 0.0.
1
1
2
2
4
4
5
5
3
3
9
9
10
10
8
8
6
6
7
7
11
11
12
12
13
13
14
14
15
15
TURBO SELF CLEAN
TURBO SELF CLEAN
SLEEP
SLEEP
SHORT CUT
SHORT CUT
TIMER ON
TIMER ON
TIMER OFF
TIMER OFF
LOCK
LOCK
RESET
RESET
LED FOLLOW ME
LED FOLLOW ME
FAN SPEED
FAN SPEED
SWING
SWING
MODE
MODE
TEMP
TEMP
ON/OF F
ON/OF F
SWING
SWING
14
15
LOCK Button
When you press the recessed LOCK button, all current settings are locked in and the remote control does not accept any operation except that of the LOCK. Press again to cancel the LOCK mode.
,
,
7
When you press the recessed RESET button, all current settings are cancelled and the control will return to the initial settings.
RESET Button:
SHORTCUT Button
Used to restore the current settings or resume previous settings. When first connected to power, pressing the SHORTCUT button will activate the AUTO
O
mode, 24 C, and fan speed is Auto. Pressing this button when unit is on, the system will automatically revert back to the previous settings including operating mode, setting temperature, fan speed level and sleep feature (if activated). If pressed and held for more than 2 seconds, the system will automatically restore the current operation settings including operating mode, setting temperature, fan speed level and sleep feature (if activated).
LED/FOLLOW ME function
Press this button to initiate the LED function. Press and hold this button for more than 2 seconds and the FOLLOW ME function is initiated. When the Follow Me function is activated, the remote display is actual temperature at its location. The remote control will send this signal to the air conditioner at 3 minute intervals until you press the FOLLOW ME button again. The Follow Me function is not available under DRY and FAN mode. Switching the operational mode or turning off the unit will cancel the FOLLOW ME function.
7 8
Indicators on LCD
Transmission Indicator
Temp./Timer Display
Fan Speed Display
Silence Display (where fitted)
Sleep Display
Mode Display
ON/OFF Display
This transmission indicator lights when remote control transmits signals to the indoor unit.
Displays the current operation mode. Including auto( ), cool( ), dry( ), heat( ), fan ( ) and back to auto ( ).
O O
Displays the temperature setting(17 C~30 C). When you set the operating mode to FAN, no temperature setting is displayed. If in TIMER mode, shows the ON and OFF settings of the TIMER.
Displayed by pressing the ON/OFF button. Press the ON/OFF button again to change.
Displays the selected fan speed, AUTO (no display) and three fan speed levels " " (LOW) " " (MED) " " (HIGH) can be indicated. The fan speed is AUTO when the operating mode is either AUTO or DRY.
Displayed when SILENCE function is activated.
Displayed during SLEEP mode. Press the SLEEP button again to exit SLEEP mode.
Note:
All indicators shown in the figure are for the purpose of presentation. During the actual operation of the remote control only the relative functional signs are shown in the display window.
Lock Display
Displayed when LOCK mode is activated.
FOLLOW ME Display
Displayed when FOLLOW ME function is activated.
F
auto cool dry heat fan
silen ce sle ep fol low me l ock run
SET TEMP. TIMER ONOFF
System Operation
Cooling /Heating/Fan Operation
Ensu re t he u ni t is p lugge d in a nd p ow er i s avai la bl e.
1. Pre ss t he M OD E bu tton to s el ec t CO OL , HEAT or FAN m od e.
2. Pre ss t he U P/ DO WN butt on s to s et t he desi re d te mp er ature . Th e te mp er ature c an
O O O
be set w it hi n a ra ng e of 17 C~ 30 C in 1 C incr em en ts .
3. Pre ss t he FA N bu tt on to sel ec t th e fa n sp eed in fou r st ep s- Auto, L ow, M ed ,o r Hi gh.
4. Pre ss t he O N/ OF F butto n to s ta rt t he a ir cond it io ne r.
In the FAN mode, the temperature setting is not displayed on the remote control, and you are unable to control the room temperature. In FAN mode, only steps 1, 3 and 4 may be performed.
NOTE
Auto Operation
Ensu re t he u ni t is p lugge d in a nd p ow er i s avai la bl e. T he O PERATIO N ind ic at or o n th e disp la y pa ne l of t he indo or u ni t wi ll s tart flas hi ng .
1. Pre ss t he M OD E bu tton to s el ec t Auto.
2. Pre ss t he U P/ DO WN butt on t o se t th e desi re d te mp er ature . Th e te mp er ature c an
O O O
be set w it hi n a ra ng e of 17 C~ 30 C in 1 C incr em en ts .
3. Pre ss t he O N/ OF Fbutt on t o st ar t th e air cond it io ne r.
1. In the Auto mode, the air conditioner will logically choose Cooling, Fan, or Heating mode by sensing the difference between the actual ambient room temperature and the set point temperature on the remote control.
2. In the Auto mode, you can not control the fan speed. It is automatically controlled by the unit.
3. If the Auto mode is not comfortable for you , set the desired mode manually.
NOTE
3
1
2
4
1
2
3
2
2
TURBO SELF CLEAN
SLEEP
SLEEP
SHORT CUT
SHORT CUT
TIMER ON
TIMER OFF
LOCK
RESET
LED FOLLOW ME
FAN SPEED
SWING
MODE
TEMP
ON/OFF
ON/OFF
SWING
TURBO SELF CLEAN
TIMER ON
TIMER OFF
LOCK
RESET
LED FOLLOW ME
FAN SPEED
SWING
MODE
TEMP
SWING
9 10
Dehumidifying (DRY) Operation
Ensu re t he u ni t is p lugge d in a nd p ow er i s avai la bl e. T he O PERATIO N ind ic at or o n th e disp la y pa ne l of t he indo or u ni t st ar ts flas hi ng .
1. Pre ss t he M OD E bu tton to s el ec t DRY mod e.
2. Pre ss t he U P/ DO WN butt on s to s et t he desi re d te mp er ature . Th e te mp er ature
O O
can be s et w it hi n a ra nge of 17 C~ 3 0 C
O
in 1 C incr em en ts .
3. Pre ss t he O N/ OF F butto n to s ta rt t he a ir cond it io ne r.
In Dehumidifying mode, you can not control the fan speed. It is automatically controlled by the unit.
NOTE
Adjusting Air Flow Direction
TURBO SELF CLEAN
TIMER ON
TIMER OFF
LOCK
RESET
LED FOLLOW ME
FAN SPEED
SWING
MODE
TEMP
SWING
Use the SWING and SWING buttons to adjust the desired airflow direction.
1. Press the SWING button, and the horizontal louver changes 6 degree in angle for each push. Press and hold for more than 2 seconds, and the louver will automatically swing up and down.
2. Press the SWING button, and the vertical louver changes 6 degree in angle for each push. Press and hold for more than 2 seconds, and the louver will automatically swing left and right.
NOTE: When the horizontal/vertical louver swing moves to a position which may affect the cooling or heating effect of the air conditioner, it may automatically change the horizontal or vertical position.
Timer operation
Press the TIMER ON button to set the auto-on time of the unit. Press the TIMER OFF button to set the auto-off time of the unit.
1. Press the TIMER ON button. The remote control shows TIMER ON, the last Auto-on setting time and the signal "H" will be shown in the LCD display area. Now it is ready to reset the Auto-on time to the START time.
2. Press the TIMER ON button again to set desired Auto-on time. Each time you press the button, the time increases by half an hour between 0 and 10 hours and by one hour between 10 and 24 hours.
3. After setting the TIMER ON function, there will be a one second delay before the remote control transmits the signal to the air conditioner. Then, after approximately another 2 seconds, the signal "H" will disappear and the set temperature will re-appear in the LCD display window.
To set the Auto-on time.
To set the Auto-off time.
1. Press the TIMER OFF button. The remote control shows TIMER OFF, the last Auto-off setting time and the signal "H" will be shown in the LCD display area. Now it is ready to reset the Auto-off time to stop time.
2. Press the TIMER OFF button again to set desired Auto-off time. Each time you press the button, the time increases by half an hour between 0 and 10 hours and by one hour between 10 and 24 hours.
3. After setting the TIMER OFF function, there will be a one second delay before the remote control transmits the signal to the air conditioner. Then, after approximately another 2 seconds, the signal "H" will disappear and the set temperature will re-appear in the LCD display window.
1
2
ON/OFF
SLEEP
SHORT CUT
3
1
2
2
TURBO SELF CLEAN
TIMER ON
TIMER OFF
LOCK
RESET
LED FOLLOW ME
FAN SPEED
SWING
MODE
TEMP
SWING
ON/OFF
SLEEP
SHORT CUT
11
12
The effective operation time set by the remote control for the timer function is limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0,
5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10, 11, 12, 13, 14, 15,16,17, 18, 19, 20, 21, 22, 23 and 24.
CAUTION
!
Example of timer setti ng
Start
Off
6 hours later
(Auto-on Operation)
The TIMER ON feature is useful when you want the unit to turn on automatically before you return home. The air conditioner will automatically start operating at the set time.
To start the air conditioner in 6 hours.
1. Press the TIMER ON button, the last setting of starting operation time and the signal "H" will show in the display area.
2. Press the TIMER ON button to display "6.0h" on the TIMER ON display of the remote control.
3. Wait for 3 seconds and the digital display area will show the temperature again. The "TIMER ON" indicator remains on and this function is activated.
TIMER ON
Example:
Set
TIMER ON
Stop
On
Set 10 hours later
(Auto-off Operation)
The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed. The air conditioner will stop automatically at the set time.
To stop the air conditioner in 10 hours.
1. Press the TIMER OFF button, the last setting of stopping operation time and the signal "H" will show in the display area.
2. Press the TIMER OFF button to display "10h" on the TIMER OFF display of the remote control.
3. Wait for 3 seconds and the digital display area will show the temperature again. The "TIMER OFF" indicator remains on and this function is activated.
TIMER OFF
Example:
On
Stop
2 hours later after setting
Set
To stop the air conditioner 2 hours after setting and start it again 10 hours after setting.
1. Press the TIMER OFF button.
2. Press the TIMER OFF button again to display
2.0h on the TIMER OFF display.
3. Press the TIMER ON button.
4. Press the TIMER ON button again to display 10h on the TIMER ON display .
5. Wait for 3 seconds and the digital display area will show the temperature again. The "TIMER ON OFF" indicator remains on and this function is activated.
TIMER OFF TIMER ON (On Stop Start operation) This feature is useful when you want to stop the air conditioner after you go to bed, and start it again in the morning when you wake up or when you return home.
Example:
COMBINED TIMER
(Setting both ON and OFF timers simultaneously)
Start
10 hours later after setting
TIMER OF F
TIMER ON O FF
13
14
Example:
TIMER ON TIMER OFF (Off Start Stop operation) This feature is useful when you want to start the air conditioner before you wake up and stop it after you leave the house.
To start the air conditioner 2 hours after setting, and stop it 5 hours after setting.
1. Press the TIMER ON button.
2. Press the TIMER ON button again to display
2.0h on the TIMER ON display.
3. Press the TIMER OFF button.
4. Press the TIMER OFF button again to display
5.0h on the TIMER OFF display .
5. Wait for 3 seconds and the digital display area will show the temperature again. The "TIMER ON OFF" indicator remains on and this function is activated.
Off
Stop
Start
2 hours later after setting
5 hours later after setting
Set
NOTE: The timer setting (TIMER ON or TIMER OFF) that occurs directly after the set time will be activated first.
TIMER ON OFF
This page is intentionally blank