RIDGID micro LM-100 Operator's Manual

micro LM-100 Laser Distance Meter
micro LM-100 Operator’s Manual
Français – 13
Castellano – pág. 27
Türkçe – 41
Русский язык – 55
WARNING!
Read this Operator’s Man ­ual carefully before using this tool. Failure to under­stand and follow the con­tents of this manual may result in electrical shock, fire and/or serious person ­al injury.
micro LM-100 Laser Distance Meter
Ridge Tool Company
II
Clearing Data From Memory ..................................................9
Backlighting The Display ........................................................9
Measurements
Single Distance Measurement................................................9
Continuous Measurement, Max. and Min. Measurement.......9
Adding/Subtracting Measurements ........................................9
Area Measurement.................................................................9
Volume Measurement...........................................................10
Indirect Measurements
Using Two Points..................................................................10
Using Three Points ...............................................................11
Cleaning ..................................................................................11
Storage ....................................................................................11
Service and Repair .................................................................11
Disposal ..................................................................................12
Troubleshooting .....................................................................12
Lifetime Warranty.....................................................Back Cover
*Original Instructions - English
Table of Contents
Recording Form for Machine Serial Number.........................1
Safety Symbols.........................................................................2
General Safety Rules
Work Area Safety ...................................................................3
Electrical Safety......................................................................3
Personal Safety ......................................................................3
Equipment Use and Care .......................................................3
Service....................................................................................4
Specific Safety Information
Laser Distance Meter Safety ..................................................4
Description, Specifications and Standard Equipment
Description..............................................................................4
Specifications .........................................................................4
Controls ..................................................................................5
LCD Display Icons..................................................................6
Standard Equipment...............................................................6
Laser Classification .................................................................6
FCC Statement..........................................................................6
Electromagnetic Compatibility (EMC) ....................................7
Installing Wrist Strap................................................................7
Changing/Installing Batteries..................................................7
Pre-Operation Inspection ........................................................7
Set-Up and Operation ..............................................................8
LM-100 Controls and Settings
Turning ON and OFF..............................................................8
Setting Measurement Reference Point...................................8
Changing Display Units ..........................................................8
Clearing Displayed Detail/Last Action.....................................8
Reviewing The Last 20 Measurements ..................................8
micro LM-100 Laser Distance Meter
micro LM-100 Laser Distance Meter
Record Serial Number below and retain product serial number which is located on nameplate.
Serial No.
micro LM-100
micro LM-100 Laser Distance Meter
Ridge Tool Company
2
Safety Symbols
In this operator’s manual and on the product, safety symbols and signal words are used to communicate important safety information. This section is provided to improve understanding of these signal words and symbols.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE indicates information that relates to the protection of property.
This symbol means read the operator’s manual carefully before using the equipment. The operator’s manual contains important information on the safe and proper operation of the equipment.
NOTICE
DANGER
WARNING
CAUTION
This symbol means this device contains a Class 2 Laser.
This symbol means do not stare into the laser beam.
This symbol warns of the presence and hazard of a laser beam.
DO NOT STARE INTO BEAM
LASER RADIATION
MAXIMUM OUTPUT < 1mW
WAVELENGTH 630-670nm
CLASS 2 LASER PRODUCT
EN 60825-1:1994/A11:1996/A2:2001/A1:2002
CAUTION
micro LM-100 Laser Distance Meter
Ridge Tool Company
3
shoes, hard hat, or hearing protection used for appropriate con­ditions will reduce personal injuries.
Do not overreach. Keep proper footing and balance at all times. This enables better control of the power tool in unex­pected situations.
Equipment Use and Care
Do not force equipment. Use the correct equipment for your application. The correct equipment will do the job better and
safer at the rate for which it is designed
Do not use equipment if the switch does not turn it ON and OFF. Any tool that cannot be controlled with the switch is danger­ous and must be repaired.
Disconnect the batteries from the equipment before making any adjustments, changing accessories, or storing. Such preventive safety measures reduce the risk of injury.
Store idle equipment out of the reach of children and do not
allow persons unfamiliar with the equipment or these in­structions to operate the equipment. Equipment can be dan-
gerous in the hands of untrained users.
Maintain equipment. Check for misalignment or binding of mov- ing parts, missing parts, breakage of parts and any other condi­tion that may affect the equipment’s operation. If damaged, have the equipment repaired before use. Many accidents are caused by poorly maintained equipment
Use the equipment and accessories in accordance with
these instructions, taking into account the working condi­tions and the work to be performed. Use of the equipment for
operations different from those intended could result in a haz­ardous situation
Use only accessories that are recommended by the manu- facturer for your equipment. Accessories that may be suitable
General Safety Rules
WARNING
Read all safety warnings and instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury.
SAVE THESE INSTRUCTIONS!
Work Area Safety
Keep your work area clean and well lit. Cluttered or dark areas invite accidents.
Do not operate equipment in explosive atmospheres, such
as in the presence of flammable liquids, gases, or dust.
Equipment can create sparks which may ignite the dust or fumes
Keep children and by-standers away while operating equip- ment. Distractions can cause you to lose control.
Electrical Safety
Avoid body contact with earthed or grounded surfaces such as pipes, radiators, ranges and refrigerators. There is an in-
creased risk of electrical shock if your body is earthed or grounded.
Do not expose equipment to rain or wet conditions. Water entering equipment will increase the risk of electrical shock.
Personal Safety
Stay alert, watch what you are doing and use common sense when operating equipment. Do not use equipment while you are tired or under the influence of drugs, alcohol or medica­tion. Amoment of inattention while operating equipment may re-
sult in serious personal injury.
Use personal protective equipment. Always wear eye protec­tion. Protective equipment such as dust mask, non-skid safety
micro LM-100 Laser Distance Meter
Ridge Tool Company
4
• Visit www.RIDGID.com or www.RIDGID.eu to find your local Ridge Tool contact point.
• Contact Ridge Tool Technical Services Department at rtctechser­vices@emerson.com, or in the U.S. and Canada call (800) 519-
3456.
Description, Specifications And Standard Equipment
Description
The RIDGID®micro LM-100 provides simple, quick, and accurate distance readings at the push of a button. You simply push the measurement button to turn on the class II laser and point at the re­mote or difficult to reach place to be measured to, then push the measurement button again. The micro LM-100 provides a quick measurement on a clear easy to read backlit LCD display.
Specifications
Range ...........................................0.05 to 50m*
(0.16 ft to 164 ft*)
Measuring Accuracy Up To 10m
(2, Standard Deviation).................Typically: ±1.5mm**
(± 0.06 in**)
Measuring Units............................m, in, ft
Laser Class...................................Class II
Laser Type....................................635 nm, <1 mW
Ingress Protection.........................IP 54 Dust Proof, Splash Proof
Memory.........................................20 Measurements
Operating Temperature.................0°C to 40°C (32°F to 104°F)
Storage Temperature....................-10°C to 60°C (14°F to 140°F)
Battery Life ...................................Up to 4,000 Measurements
for one piece of equipment may become hazardous when used with other equipment
Keep handles dry and clean; free from oil and grease. Allows for better control of the equipment.
Service
Have your equipment serviced by a qualified repair person using only identical replacement parts. This will ensure that
the safety of the tool is maintained.
Specific Safety Information
WARNING
This section contains important safety information that is specific to this tool.
Read these precautions carefully before using the micro LM­100 Laser Distance Meter to reduce the risk of eye injury or other serious personal injury.
SAVE THESE INSTRUCTIONS!
Keep this manual with the tool for use by the operator.
Laser Distance Meter Safety
Do not look into the laser beam. Looking into the laser beam may be hazardous to the eyes. Do not look at the laser beam with optical aids (such as binoculars or telescopes).
Do not direct the laser beam towards other people. Make sure the laser is aimed above or below eye level. Laser beams may be hazardous to the eyes.
If you have any question concerning this Ridge Tool product:
• Contact your local RIDGID distributor.
Batteries .......................................(2) AAA
Auto. Laser Switch-Off..................After 30 Seconds
Auto. Shut-Off...............................After 3 Minutes of Inactivity
Dimension ......................................115 x 48 x 28mm
(4
1
/2" x 17/8x 11/8")
Weight...........................................0.2kg (7oz)
Features
• Area, Volume Calculations
• Indirect Measurement
• Addition/Subtraction
• Display Illumination and Multi-line Display
* Range is limited to 50m (164 ft.) Use a commercially available target plate to
improve measurement ability during daylight or if the target has poor reflec­tion properties.
**In favorable conditions (good target surface properties, room temperature) up
to 10m (33 ft). In unfavorable conditions, such as intense sunshine, poorly re­flecting target surface or high temperature variations, the deviation over dis­tances above 10m (33 ft) can increase by ±0.15mm/m (±0.0018 in/ft).
micro LM-100 Laser Distance Meter
Ridge Tool Company
5
• Continuous Measurement
• Min/Max Distance Tracking
• Beep Indication
Figure 1 – micro LM-100 Laser Distance Meter
Controls
ON/Measurement
Button
Clear/Power
OFF Button
Backlight/Unit
Change Button
Subtraction
Button
Indirect
Measurement
Button
Continuous
Measurement
Button
Area/Volume
Button
Measurement
Reference Point
Button
Memory
Button
Addition
Button
Figure 2 – micro LM-100 Buttons
micro LM-100 Laser Distance Meter
Ridge Tool Company
6
This equipment is used to make distance measure­ments. Incorrect use or improper application may result in incorrect or inaccurate measurements. Selection of appropriate measure­ment methods for the conditions is the responsibility of the user.
Laser Classification
The RIDGID micro LM-100 generates a visible laser beam that is emitted from the top of the device.
The device complies with class 2 lasers according to: EN 60825­1:1994/A11:1996/A2:2001/A1:2002
FCC Statement
This equipment has been tested and found to comply with the lim­its for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruc­tions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or tele­vision reception, which can be determined by turning the equip­ment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Consult the dealer or an experienced radio/TV technician for help.
Standard Equipment
• micro LM-100
• Carrying Case
• Wrist Strap
Laser
Active
Reference
Bottom
Reference
Top
Device Malfunction
Measuring
Functions
First Prior
Measurement
Second
Prior
Measurement
Min Max
(Continuous)
Memory
Location
Single
Measurement
Single
Measure-
ment/Calcula-
tion Result
Figure 3 – micro LM-100 LCD Display
LCD Display Icons
Battery
Indicator
• Batteries (2 AAA)
• Operator's Manual
NOTICE
micro LM-100 Laser Distance Meter
Ridge Tool Company
7
2. Remove existing batteries.
3. Install two AAAalkaline batteries (LR03), observing the correct polarity as indicated in the battery compartment.
Use batteries that are of the same type. Do not mix bat­tery types. Do not mix new and used batteries. Mixing batteries can cause overheating and battery damage.
4. Replace cover and tighten screw.
Pre-Operation Inspection
WARNING
Before each use, inspect your distance meter and correct any problems to reduce the risk of injury or incorrect measure­ments.
Do not look into the laser beam. Looking into the laser beam may be hazardous to the eyes.
1. Clean any oil, grease or dirt from equipment. This aids inspec­tion.
2. Inspect the distance meter for any broken, worn, missing, mis­aligned or binding parts, or any other condition which may pre­vent safe and normal operation.
3. Check that the warning labels are present, firmly attached and readable.
(See Figure 6.)
4. If any issues are found during the inspection, do not use the distance meter until it has been properly serviced.
5. Following the Operation Instructions, turn the distance meter on, make a measurement and confirm the same measurement with another instrument (tape measure, etc.). If the correlation between the measurements is not acceptable, do not use the distance meter until it has been properly serviced.
Electromagnetic Compatibility (EMC)
The term electromagnetic compatibility is taken to mean the capa­bility of the product to function smoothly in an environment where electromagnetic radiation and electrostatic discharges are present and without causing electromagnet interference to other equipment.
The RIDGID micro LM-100 conforms to all applicable ECM standards. However, the possibility of it causing interference in other devices cannot be precluded.
Installing Wrist Strap
Route small end of wrist strap through loop on micro LM-100 hous­ing. Thread strap end through loop of small end and pull tight.
Figure 4 – Installing Lanyard
Changing/Installing Batteries
The micro LM-100 is supplied with batteries installed. If the battery indicator is flashing, the batteries need to be replaced. Remove the batteries prior to long term storage to avoid battery leakage.
(Fig-
ure 5)
1. Use a Phillips head screw driver to loosen the battery compart­ment cover screw and remove the cover.
NOTICE
Figure 5 – Changing Batteries
NOTICE
Figure 6 – Warning Labels
Set-Up and Operation
WARNING
Do not look into the laser beam. Looking into the laser beam may be hazardous to the eyes. Do not look at the laser beam with optical aids (such as binoculars or telescopes).
Do not direct the laser beam towards other people. Make sure the laser is aimed above or below eye level. Laser beams may be hazardous to the eyes.
Set up and operate the distance meter according to these pro­cedures to reduce the risk of injury or incorrect measurements.
1. Check for an appropriate work area as indicated in the
General
Safety Section
.
2. Inspect the object being measured to and confirm that you have correct equipment for the application. The micro LM-100 Laser Distance Meter is designed to measure distances up to 50m
micro LM-100 Laser Distance Meter
Ridge Tool Company
8
(164 feet).
See the Specifications section
for range, accuracy
and other information.
3. Make sure that all equipment has been properly inspected.
micro LM-100 Controls and Settings
Turning ON and OFF
Press the ON/Measurement Button to turn ON the distance meter and the laser. Make sure that the laser is pointed in a safe direction before turning ON.
Press and Hold the Clear/Power OFF Button to turn the Dis­tance meter OFF. The laser distance meter will turn OFF automat­ically after three minutes of inactivity.
Setting Measurement Reference Point
When the distance meter is turned ON, the default measurement reference point is the back edge of the meter . Press the Measure­ment Reference Point Button to change the measurement ref­erence point to the front edge (laser end) of the meter. The meter will beep and the display will show the reference point front symbol
.
Changing Display Units
Press and Hold the Backlight/Unit Change Button to change the display units. Available Units: Feet, Meters, Inches.
Clearing Displayed Data/Last Action
Press the Clear/Power OFF Button to clear the displayed data or cancel the last action.
Reviewing the Last 20 Measurements
Press the Memory Button to review the last twenty measure-
micro LM-100 Laser Distance Meter
Ridge Tool Company
9
Continuous Measurement, Max and Min Measurement
1. Press and Hold Continuous Measurement Button to enter the continuous measurement mode. In continuous measure­ment mode, the measured value is updated approximately every 0.5 seconds in the third line. The corresponding mini­mum and maximum values are displayed dynamically in the first and second line.
2. Press and Hold either ON/Measurement Button or Clear/­Power OFF Button to stop taking continuous measure­ments. The device automatically stops after 100 continuous measurements.
Adding/Subtracting Measurements
1. Press Addition Button to add the next measurement to the previous one.
2. Press Subtraction Button to subtract the next measurement the previous one.
3. Press Clear/Power OFF Button to cancel the last action.
4. Press Clear/Power OFF Button again to return to taking single measurements.
Area Measurement
1. Press Area/Volume Button . The symbol appears in the display. The distance to be measured will flash in the symbol.
2. Press ON/Measurement Button to take the first measure­ment (e.g. length).
3. Press ON/Measurement Button again to take the second measurement (e.g. width).
4. The result of the area calculation is displayed in the third line; the individually measured values are displayed in lines 1 and 2.
ments or calculated results, shown in reverse order. Use the Addi­tion or Subtraction Buttons to move through these records.
Clearing Data From Memory
Press and Hold the Memory Button and Press and Hold the Clear/Power Button Key at the same time to clear all data in the memory.
Backlighting the Display
Press the Backlight/Unit Change Button to turn the display back­light ON or OFF.
Measurements
The RIDGID micro LM-100 Laser Distance Meter has a measuring range of 50m (164') maximum. Use in bright sunlight may decrease the range of the meter. The reflective properties of the surface may also decrease the range of the meter.
Measurement errors can occur when measuring to clear, semi-per­meable or high gloss/reflective surfaces such as colorless liquids (e.g. water), glass, Styrofoam, mirrors, etc. Applying a commercially available laser target plate to the surface may allow more accurate measurements.
Do not aim the laser at the sun. This can damage the
meter.
Single Distance Measurement
1. Press ON/Measurement Button to activate the laser. Press ON/Measurement Button again to take a measurement.
2. The measured value is displayed immediately.
NOTICE
micro LM-100 Laser Distance Meter
Ridge Tool Company
10
triangle. All measurements need to be to points on a single straight line.
Using Two Points
Figure 7 – Indirect Measurement Using Two Points
1. Press Indirect Measurement Button once. The symbol will show in the display. The distance to be measured will flash in the symbol.
2. Press ON/Measurement Button to turn ON the laser, aim the laser at the upper point (1) and trigger the measurement. The measurement will be displayed in the first line.
3. The next distance to be measured will flash.
4. Press ON/Measurement Button to turn on the laser, keep­ing the instrument as perpendicular to the line between the measurements as possible, Press ON/Measurement Button
again to measure the distance result of the horizontal point (2). The measurement will be displayed in the second line.
5. The result of the calculation is displayed in third line.
Volume Measurement
1. Press Area/Volume button . The symbol appears in the display. The distance to be measured will flash in the symbol.
2. Press Area/Volume button again, the symbol for vol­ume measurement appears in the display. The distance to be measured will flash in the symbol
3. Press ON/Measurement Button to take the first measure­ment (e.g. length).
4. Press ON/Measurement Button again, to take the second measurement (e.g. width).
5. The result of the area calculation is displayed in the third line; the individually measured values are displayed in lines 1 and 2.
6. Press ON/Measurement Button again, take the third dis­tance measurement (e.g. height). The value is displayed in the second line.
The result of the volume calculation is displayed in the third line.
Indirect Measurements
Indirect measurements are used when a direct measurement is not possible. Indirect measurements are calculated from measurements of the hypotenuse and one side of a right triangle (triangle with a 90 degree angle). For instance, if calculating the height of a wall from the ground, measurements would be taken to the top of the wall (hypo­tenuse), and perpendicular to the line between the two measurement points at the wall base (side). From these two measurements, the distance between the two measurement points is calculated.
Indirect measurements are less accurate than direct measurements. For greatest accuracy with Indirect Measurements, hold the micro LM-100 in the same position (only changing angle) for all measure­ments. Make sure that the laser beam is perpendicular to the line be­tween the measurement points when measuring the side of the
micro LM-100 Laser Distance Meter
Ridge Tool Company
11
to take the measurement. The measurement will be displayed in the second line.
7. The result of the calculation is displayed in third line.
Cleaning
Do not immerse the RIDGID micro LM-100 in water. Wipe off dirt with a damp soft cloth. Do not use aggressive cleaning agents or solutions. Treat the instrument as you would a telescope or camera.
Storage
The RIDGID micro LM-100 laser distance meter must be stored in a dry secure area between -10°C (14°F) and 60°C (158°F).
Store the tool in a locked area out of the reach of children and peo­ple unfamiliar with the laser distance meter.
Remove the batteries before any long period of storage or shipping to avoid battery leakage.
Service and Repair
WARNING
Improper service or repair can make the RIDGID micro LM-100 unsafe to operate.
Service and repair of the RIDGID micro LM-100 must be performed by a RIDGID Independent Authorized Service Center.
For information on your nearest RIDGID Independent Service Cen­ter or any service or repair questions:
• Contact your local RIDGID distributor.
• Visit www.RIDGID.com or www.RIDGID.eu to find your local Ridge Tool contact point.
• Contact Ridge Tool Technical Services Department at rtctechser-
Using Three Points
Figure 8 – Indirect Measurement Using Three Points
1. Press Indirect Measurement Button once, the sym­bol will show in the display. The distance to be measured will flash in the symbol.
2. Press Indirect Measurement Button again, the sym­bol will show in the display. The distance to be measured will flash in the symbol.
3. Aim the laser at the lower point (1) and press button 1 to take the measurement. The measurement will be displayed in first line.
4. The next distance to be measured will flash.
5. Press ON/Measurement Button to turn on the laser, keep­ing the instrument as perpendicular to the line between the measurements as possible, Press ON/Measurement Button
again to measure the distance result of the horizontal point
(2). The measurement will be displayed in the second line.
6. Press ON/Measurement Button to turn on the laser, aim the laser at the top point, press ON/Measurement Button
micro LM-100 Laser Distance Meter
Ridge Tool Company
12
For EC Countries: Do not dispose of electrical equip­ment with household waste!
According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment and its
implementation into national legislation, electrical equip­ment that is no longer usable must be collected separately and dis­posed of in an environmentally correct manner.
Battery Disposal
For EC countries: Defective or used batteries must be recycled ac­cording to the guideline 2006/66/EEC.
vices@emerson.com, or in the U.S. and Canada call (800) 519-
3456.
For troubleshooting suggestions, please refer to the trouble-shoot­ing guide on
page 12
.
Disposal
Parts of the micro LM-100 Laser Distance Meter contain valuable materials and can be recycled. There are companies that special­ize in recycling that may be found locally. Dispose of the com­ponents in compliance with all applicable regulations. Contact your local waste management authority for more information.
204
208
209
252
253
255
Calculation error.
Received signal too weak, measurement time too long, Distance >50m.
Received signal too strong. Target too reflective. Temperature too high. Temperature too low. Hardware error.
Repeat procedure. Use target plate.
Use a commercially available target plate. Cool down instrument. Warm up instrument. Power the unit OFF then ON, if the symbol still ap-
pears, please contact technical support.
CODE CAUSE CORRECTIVE MEASURE
Troubleshooting - Error Codes
Télémètre laser micro LM-100
Télémètre laser micro LM-100
Notez ci-dessous le numéro de série indiqué sur la plaque signalétique de l’instrument pour future référence.
Nº de série
micro LM-100
AVERTISSEMENT
Familiarisez-vous bien avec le mode d’emploi avant d’utiliser l’appareil. L’incompréhension ou le non-respect des consignes ci-après augmenter ­aient les risques de choc électrique, d’incendie et/ou d’accident grave.
Télémètre laser micro LM-100
Ridge Tool Company
14
Effacement des détails et dernières mesures ......................22
Révision des 20 dernières mesures prises...........................22
Effacement de la mémoire....................................................22
Eclairage de fond..................................................................22
Prise de mesures
Prise de mesures de distance simple...................................23
Prise de mesures maxi et mini en continu............................23
Addition et soustraction des mesures prises........................23
Mesures de superficie ..........................................................23
Mesures de volume ..............................................................23
Mesures indirectes
A l’aide de deux points .........................................................24
A l’aide de trois points ..........................................................24
Nettoyage................................................................................25
Stockage .................................................................................25
Révisions et réparations........................................................25
Recyclage de l’instrument.....................................................25
Dépannage..............................................................................26
Garantie à vie ......................................................Page de garde
*Traduction de la notice originale
Table des matière
Fiche d’enregistrement du numéro
de série de l’instrument ............................................................13
Symboles de sécurité ............................................................15
Consignes générales de sécurité
Sécurité des lieux .................................................................16
Sécurité électrique................................................................16
Sécurité individuelle..............................................................16
Utilisation et entretien de l’instrument...................................16
Révisions..............................................................................17
Consignes de sécurité spécifiques
Sécurité du télémètre laser...................................................17
Description, caractéristiques techniques et équipements de base
Description............................................................................17
Caractéristiques techniques .................................................18
Commandes .........................................................................19
Icônes d’affichage LCD ........................................................19
Equipements de base...........................................................19
Classification du laser ...........................................................20
Avertissement FCC ................................................................20
Compatibilité électromagnétique..........................................20
Montage du bracelet ..............................................................20
Remplacement des piles .......................................................20
Examen préalable...................................................................21
Préparation et utilisation de l’instrument ............................21
Commandes et paramètres du LM-100
Activation/désactivation........................................................22
Etablissement d’un point de départ ......................................22
Changement d’unités de mesure..........................................22
Télémètre laser micro LM-100
Symboles de sécurité
Des symboles et mots clés spécifiques, utilisés à la fois dans ce mode d’emploi et sur l’instrument lui-même, servent à signaler d’impor­tants risques de sécurité. Ce qui suit permettra de mieux comprendre la signification de ces mots clés et symboles.
Ce symbole sert à vous avertir aux dangers physiques potentiels. Le respect des consignes qui le suivent vous permettra d’éviter les risques de blessures graves ou mortelles.
Le terme DANGER signifie une situation dangereuse potentielle qui, faute d’être évitée, provoquerait la mort ou de graves blessures corporelles.
Le terme AVERTISSEMENT signifie une situation dangereuse potentielle qui, faute d’être évitée, serait susceptible d’entraîner la mort ou de graves blessures corporelles.
Le terme ATTENTION signifie une situation dangereuse potentielle qui, faute d’être évitée, serait susceptible d’entraîner des blessures corporelles légères ou modérées.
Le terme NOTA signifie des informations concernant la protection des biens.
Ce symbole indique la nécessité de lire le manuel soigneusement avant d’utiliser le matériel. Le mode d’emploi renferme d’importantes informations concernant la sécurité d’utilisation du matériel.
NOTA
DANGER
AVERTISSEMENT
ATTENTION
Ce symbole indique la présence d’un laser Classe 2.
Ce symbole indique qu’il ne faut pas regarder dans le faisceau du laser.
Ce symbole indique la présence d’un faisceau laser dangereux.
DO NOT STARE INTO BEAM
LASER RADIATION
MAXIMUM OUTPUT < 1mW
WAVELENGTH 630-670nm
CLASS 2 LASER PRODUCT
EN 60825-1:1994/A11:1996/A2:2001/A1:2002
CAUTION
Ridge Tool Company
15
* ATTENTION
Faisceau laser. Ne pas regarder dans le faisceau. Puissance maxi < 1mW. Longueur d’onde : 630 à 670 nm. Laser Classe 2
*
Télémètre laser micro LM-100
Ridge Tool Company
16
vous êtes sous l’influence de drogues, de l’alcool ou de médica­ments. Lors de l’utilisation d’un appareil électrique, un instant d’i­nattention risque d’entraîner de graves lésions corporelles.
Prévoyez les équipements de protection individuelle néces- saires. Portez systématiquement une protection oculaire. Le port d’un masque à poussière, de chaussures de sécurité antidéra­pantes, d’un casque de chantier ou de protecteurs d’oreilles s’im­pose lorsque les conditions l’exigent.
Evitez les démarrages accidentels. S’assurer que l’interrup-
teur est en position arrêt avant de brancher l’appareil, d’y in­troduire son bloc-piles ou de le transporter. Transporter un
appareil électrique avec son doigt sur la gâchette ou le brancher lorsque l’interrupteur marche/arrêt se trouve en position marche serait inviter les accidents.
Ne vous mettez pas en porte-à-faux. Maintenez une bonne po- sition de travail et un bon équilibre à tout moment. Cela vous per­mettra de mieux contrôler l’appareil en cas d’imprévu.
Utilisation et entretien des appareils électriques
Ne forcez pas l’appareil. Prévoyez un appareil adapté aux travaux envisagés. L’appareil approprié fera le travail plus effi-
cacement et avec un plus grand niveau de sécurité lorsqu’il tourne au régime prévu.
N’utilisez pas l’appareil si son interrupteur marche/arrêt ne fonctionne pas correctement. Tout appareil qui ne peut pas être contrôlé par son interrupteur est dangereux et doit être réparé.
Retirez le bloc-piles de l’appareil avant de le régler, de changer ses accessoires ou de le ranger. De telles mesures préventives limiteront les risques de blessure.
Rangez tout appareil non utilisé hors de la portée des en-
fants et des individus qui n’ont pas été familiarisés avec ce type de matériel ou son mode d’emploi. Les appareils élec-
Consignes générales de sécurité
AVERTISSEMENT
Familiarisez-vous avec l’ensemble du mode d’emploi. Le non­respect des consignes d’utilisation et de sécurité ci-après aug­menterait les risques de choc électrique, d’incendie et/ou de grave blessure corporelle.
CONSERVEZ CES INSTRUCTIONS !
Sécurité des lieux
Assurez-vous de la propreté et du bon éclairage des lieux. Les zones encombrées ou mal éclairées sont une invitation aux accidents.
N’utilisez pas d’instruments électriques en présence de mat -
ières explosives telles que liquides, gaz ou poussières com­bustibles. Les appareils électriques produisent des étincelles
susceptibles d’enflammer les poussières et émanations com­bustibles.
Eloignez les enfants et les curieux lors de l’utilisation d’un appareil électrique. Les distractions risquent de vous faire per­dre le contrôle de l’appareil.
Sécurité électrique
Evitez tout contact physique avec les objets reliés à la terre tels que canalisations, radiateurs, cuisinières et réfrigéra­teurs. Tout contact avec la terre augmenterait les risques de choc
électrique.
N’exposez pas l’appareil à la pluie ou aux intempéries. Toute pénétration d’eau à l’intérieur d’un appareil électrique aug­menterait les risques de choc électrique.
Sécurité individuelle
Soyez attentif, faites attention à ce que vous faites et faites preuve de bon sens. N’utilisez pas d’appareil électrique lorsque
Télémètre laser micro LM-100
Ridge Tool Company
17
CONSERVEZ CES INSTRUCTIONS !
Gardez le présent manuel à portée de main de l’utilisateur.
Sécurité du télémètre micro LM-100
Ne pas regarder dans le faisceau laser de l’instrument. Le faisceau laser est capable d’endommager la vue. Ne pas regarder vers le faisceau laser avec des jumelles, un télescope ou autres aides oculaires.
Ne jamais orienter le faisceau laser vers autrui. S’assurer que le laser est orienté plus haut ou plus bas que le niveau des yeux. Tout faisceau laser est capable d’endommager la vue.
En cas de questions concernant ce produit Ridge Tool :
• Consultez votre distributeur RIDGID.
• Consultez les sites www.RIDGID.com ou www.RIDGID.eu pour localiser le représentant Ridge Tool le plus proche.
• Consultez les services techniques de Ridge Tool par mail adressé à rtctechservices@emerson.com, ou, à partir des Etats­Unis et du Canada, en composant le (800)519-3456.
Description, caractéristiques techniques et équipements de base.
Description
Le RIDGID®micro LM-100 assure des prises de mesure linéaires faciles, rapides et précises par le simple appui d’une touche. Ap­puyez une première fois sur la touche de mesure pour activer le laser Classe II, visez le point lointain ou difficile d’accès, puis ap­puyez à nouveau sur la touche mesure. La mesure correspondante s’affiche alors clairement sur l’écran LCD éclairé du micro LM-100.
triques peuvent devenir dangereux s’ils tombent entre les mains d’utilisateurs non initiés.
Veillez à l’entretien de l’appareil. Examinez-le pour signes de
désalignement, de grippage, d’absence ou de bris de ces compo sants, et de toute autre anomalie qui risquerait de nuire à son bon fonctionnement. Le cas échéant, faire répar ­er l’appareil avant de l’utiliser. De nombreux accidents sont
provoqués par des appareils mal entretenus.
Servez-vous de l’appareil et de ses accessoires selon les
consignes ci-présentes en tenant compte des conditions de travail et des travaux envisagés. L’utilisation de ce matériel à
des fins autres que celles prévues pourrait s’avérer dangereux.
Utilisez exclusivement les accessoires prévus par le fabri- cant pour votre type d’appareil particulier. L’utilisation d’acces ­soires adaptés à d’autres types d’appareil risque de s’avérer dangereuse.
Assurez la parfaite propreté de l’appareil. Cela permettra de mieux le contrôler.
Révisions
Confiez les révisions de ce matériel a un réparateur quali­fié utilisant exclusivement des pièces de rechange iden­tiques à celles d’origine. Cela assurera la sécurité intrinsèque
du matériel.
Consignes de sécurité spécifiques
WARNING
La section suivante contient d’importantes consignes de sécu­rité qui s’adressent spécifiquement à ce type d’instrument.
Afin de limiter les risques d’incendie et de choc électrique ou autres blessures graves, lisez le mode d’emploi soigneusement avant d’utiliser le télémètre micro LM-100.
Télémètre laser micro LM-100
Ridge Tool Company
18
* Portée limitée à 50 m. Utiliser une cible réfléchissante du commerce pour
améliorer la portée en plein jour ou lorsque le point ciblé réfléchit mal la lu­mière.
**Maximum de 10 m (33 pieds) sous conditions favorables (surfaces ré-
fléchissantes, bonne température ambiante). Sous conditions défavorables (soleil intense, surfaces absorbantes, variations de température extrêmes), la déviation à des distances supérieures à 10 m (33 pieds) peut atteindre ± 0,15 mm/m (± 0,0018 po/pied).
Caractéristiques techniques
Portée ...........................................0,05 à 50 m*
(0,16 à 164 pieds*) Précision jusqu’à 10 m
(2, déviation standard)..................typiquement ± 1,5 mm
(± 0,06 po**)
Unités de mesure .........................m, pouces, pieds
Catégorie de laser ........................Classe II
Type de laser ................................635 nm < 1 mW
Etanchéité.....................................IP 54 (poussière,
éclaboussure)
Mémoire........................................20 prises de mesure
Températures de fonctionnement...0°C à 40°C (32°F à 104°F)
Températures de stockage ...........-10°C à 60°C (14°F à 140°F)
Longévité des piles.......................jusqu’à 4000 prises de
mesure
Piles..............................................2 type AAA
Arrêt auto du laser ........................après 30 secondes
Arrêt auto du télémètre.................après 3 minutes d’inactivité
Dimensions.....................................115 x 48 x 28mm
(4
1
/2" x 17/8x 11/8")
Poids.............................................200 g (7 oz.)
Caractéristiques
• Calculs de superficie et volume
• Prise de mesure indirecte
• Addition/soustraction
• Eclairage d’écran et affichage multi lignes
• Prise de mesure en continu
• Relevés de distance mini/maxi
• Indicateur sonore
Figure 1 – Télémètre laser micro LM-100
Equipements de base
• micro LM-100
• Housse
• Bracelet Cet instrument est destiné aux mesures linéaires. Toute
utilisation incorrecte ou mal appropriée pourrait entraîner des ré­sultats incorrects et des manques de précision. Le choix des méth­odes de mesure appropriées reste la seule responsabilité de l’utilisateur.
Télémètre laser micro LM-100
Ridge Tool Company
19
Laser
activé
Référence
(basse)
Référence
(haute)
Anomalie
Paramètres
de mesure
Mesure
primaire
précédente
Deuxième
mesure
précédente
Mini/Maxi
(en continu)
Fichier
mémoire
Mesure
linéaire simple
Résultat de
calcul de
mesure
simple
Figure 3 – Ecran du micro LM-100
Icônes de l’écran LCD
Indicateur de charge
• Piles (2 AAA)
• Mode d’emploi
NOTA
Commandes
Marche/Mesure
Effacer/
Eteindre
Eclairage de
fond/Changeme
nt d’unités de
mesure
Soustraction
Mesure
indirecte
Prise de
mesure en
continu
Superficie/
Volume
Point de
départ
Mémoire
Addition
Figure 2 – Touches du micro LM-100
Télémètre laser micro LM-100
Ridge Tool Company
20
provoquer de parasites électromagnétiques nuisibles aux autres appareils environnants.
Le RIDGID micro LM-100 est conforme aux normes ECM applicables. Cependant, la possibilité du parasitage des appareils environnants ne peut pas être exclue.
Montage du bracelet
Enfilez la petite extrémité du bracelet à travers l’?illet du boîtier du micro LM-100, l’autre extrémité du bracelet à travers la boucle de la petite extrémité, puis serrez-le en tirant.
Figure 4 – Montage du bracelet
Remplacement des piles
Le micro LM-100 est fournie avec des piles déjà installées. Ces piles devront être remplacées dès que le témoin de charge com­mence à clignoter. Retirez les piles avant le stockage prolongé de l’instrument pour éviter les fuites d’électrolyte
(Figure 5).
1. Servez-vous d’un tournevis cruciforme pour desserrer la vis du logement de piles et retirer son couvercle.
2. Retirez les piles existantes.
3. Installez deux piles AAA (LR03) dans le compartiment selon l’orientation indiquée.
Classification du laser
Le RIDGID micro LM-100 produit un faisceau laser émis depuis le haut de l’instrument.
Cet instrument est conforme aux normes suivantes visant les lasers Classe 2 : EN 60825 – 1 :1994/A11. 1996/A2, 2001/A1, 2002.
Avertissement FCC
Cet instrument a été testé et trouvé conforme aux limites applica­bles aux appareils numériques Classe B selon l’article 15 de la ré­glementation FCC. Ces limites assurer u minimum de protection contre les parasites dans les installations domestiques.
Ce matériel produit, utilise et risque de rayonner des fréquences radio et, s’il n’est pas installer et utilisé conformément aux instruc­tions, risque de provoquer des parasites nuisibles aux communi­cations radio.
Il n’y a cependant aucune garantie que des parasites n’auront pas lieu dans une installation particulière.
Au cas où ce matériel provoquerait des parasites nuisibles à la ré­ception radio ou télévision, chose vérifiable par la mise en marche et l’arrêt de l’instrument, l’utilisateur serait conseillé d’entreprendre l’une ou plusieurs des mesures suivantes afin d’éliminer le prob­lème :
• Réorienter ou déplacer l’antenne de réception.
• Accroître la distance entre le matériel et le récepteur.
• Demander conseil au concessionnaire ou à un réparateur radio/ télé compétent.
Compatibilité électromagnétique (EMC)
Le terme « compatibilité électromagnétique » se traduit par la ca­pacité de fonctionnement normal d’un appareil en présence de ra­diations électromagnétiques et décharges électrostatiques sans
Figure 5 – Remplacement des piles
NOTA
Télémètre laser micro LM-100
Ridge Tool Company
21
Utilisez le même type de piles. Ne mélangez pas deux types de piles. N’installez pas une pile neuve avec une pile usée. Un mélange de piles risque de provoquer la surchauffe et la détéri­oration des piles.
4. Réinstallez le couvercle et serrez la vis.
Examen préalable
AVERTISSEMENT
Examinez le télémètre avant chaque utilisation et corrigez toute anomalie éventuelle afin de limiter les risques de bles­sure et de prises de mesure incorrectes.
Ne pas regarder dans le faisceau laser. Le faisceau laser risque d’endommager la vue.
1. Nettoyez l’instrument afin d’en faciliter l’inspection.
2. Examinez le télémètre pour signes de composants brisés, usés, manquants mal alignés ou grippés, ainsi que pour toute autre anomalie qui pourrait nuire au bon fonctionnement et à la sécurité de l’instrument.
3. Assurez-vous de la présence et de la lisibilité des étiquettes d’avertissement
(Figure 6).
4. N’utilisez pas l’instrument avant d’avoir corrigé toute anomalie éventuelle.
5. Allumez le télémètre selon les instructions, prenez une mesure, puis confirmez-la à l’aide d’un mètre à ruban ou autre instru­ment. Si la corrélation entre les deux mesures n’est pas accept­able, il sera nécessaire de faire réviser le télémètre avant de vous en servir.
Figure 6 – Avertissements
Préparation et utilisation de l’instrument
AVERTISSEMENT
Ne jamais regarder dans le faisceau laser. Le faisceau laser peut endommager la vue. Ne jamais regarder dans le faisceau laser à l’aide d’un instrument optique tel qu’un télescope ou des jumelles.
Ne jamais orienter le faisceau laser vers autrui. S’assurer que le laser est orienté plus haut ou plus bas que le niveau des yeux. Un faisceau laser peut endommager la vue.
Préparez et utilisez le télémètre selon les consignes suivantes afin de limiter les risques de blessure ou de prise de mesure erronée.
1. Trouvez une zone de travail appropriée en respectant la section
Consignes générales de sécurité.
NOTA
Loading...