CGO
RAM
DEFINITION
Revised on September 14th, 1994
July 20th, 1994
September 14th, 1994
Address Byte Definition Notes
RAM reset level 1
Hex
Change the data at this address to 00(H), then switch the
080000 1
machine off and on to reset all the system sttings.
Caution: Before using this RAM, print the settings of all
the system parameters (System Parameter List).
080002
↓
4
MBU ROM version Suffix/YY/MM/DD BCD
080005
080006 1 RAM reset level 1 (Same as address 080000H)
080008
↓
20
Machine’s serial number programmed by Function 15. Ascii
08001B
08001D 1 Hard disk option 01(H): Installed
080020
↓
32
Bit switches (Refer to section 4.2 in the service manual
for details)
Read only
Hex
08003F
080040
↓
32
Service RAM addresses (Refer to section 4.3 in the
service manual for details)
08005F
080061 Bit 7
080080
↓
16
Length of the DIS frame
0: 6 Bytes, 1: 4 Bytes (Default= 0)
User parameter settings (Refer to the operator’s manual
for details)
08008F
080090
↓
16
Function on/off settings (Refer to the operator’s manual
for details)
08009F
0800A0
↓
32
G4 internal switches (Refer to the ISDN G4 service
manual for details)
0800BF
0800C0
↓
16
G4 parameter switches (Refer to the ISDN G4 service
manual for details)
0800CF
SAF memory size
Read only
Hex
00(H): Standard (1MB)
0800E0 1
01(H): With 1MB memory card option (2MB total)
02(H): With 2MB memory card option (3MB total)
03(H): With 40MB hard disk option (40MB total)
0800E1 1 ISDN G4 option 01(H): Installed
0800E4 1 Printer interface option 01(H): Installed
0800E5 1 Paper feed unit option 01(H): Installed
Read only
Read only
Read only
Hex
Hex
Hex
0800E6 1 RAM reset level 1 (Same as address 080000H)
0800E7
↓
8
Power off time (YY/MM/DD)
Read only
Hex +
BCD
0800EE
- 1 -
September 14th, 1994
Address Byte Definition Notes
0800EF
↓
Current time (YY/MM/DD)
Read only
8
Hex +
BCD
0800F6
0800F8 1 Number of RTI characters Hex
0800F9
↓
21
RTI characters (20 characters + stop code: FFH) Ascii
08010D
08010E 1 Number of CSI characters Hex
08010F
↓
21
CSI characters (20 characters + stop code: FFH) Ascii
080123
080124 1 Number of TTI characters Hex
080125
↓
33
TTI characters (32 characters + stop code: FFH) Ascii
080145
080146
080147
080148
080149
08014A
08014B
080150
080151
080152
080153
08018A
08018B
2
2
2
2
2
2
ID code: Lower byte (Default= 00H)
Upper byte (Default= 00H)
Confidential ID: Lower byte (Default= 00H)
Upper byte (Default= 00H)
Memory Lock ID: Lower byte (Default= 00H)
Upper byte (Default= 00H)
CCITT Members Code: Lower byte (Default= 00H)
Upper byte (Default= 00H)
Read only
Maker Code: Lower byte (Default= 25H)
Upper byte (Default= 00H)
Read only
Economy Transmission Time: Hour (11:00PM= 2300H)
Minute
BCD
BCD
BCD
BCD
BCD
BCD
080194 1 RAM reset level 1 (Same as address 080000H) Hex
Master Counter BCD
0801A6
↓
0801A8
0801A9
↓
0801AB
0801AC
↓
0801AE
0801AF
↓
0801B1
Address Upper Byte Lower Byte
3
0801A6 Tens Units
0801A7 Thousands Hundreds
0801A8 Hundred thousands Ten thousands
Tx counter (Same as Master Counter) BCD
3
Rx counter (Same as Master Counter) BCD
3
Scanner (ADF) counter (Same as Master Counter) BCD
3
- 2 -
September 14th, 1994
Address Byte Definition Notes
0801B2
↓
3
Printer counter (Same as Master Counter) BCD
0801B4
0801B5
↓
3
Printer jam counter (Same as Master Counter) BCD
0801B7
0801B8
↓
3
Scanner (ADF) jam counter (Same as Master Counter) BCD
0801BA
0801BB
↓
3
PM counter (Same as Master Counter) BCD
0801BD
0801BE
↓
3
CTM counter (Same as Master Counter) BCD
0801C0
0801C1
↓
3
Copied page counter (Same as Master Counter) BCD
0801C3
0801C4
↓
3
Counter for jams at fusing exit (Same as Master Counter) BCD
0801C6
0801C7
↓
3
Counter for jams at Registration and Relay (Same as
Master Counter)
BCD
0801C9
0801CA
↓
3
Jam counter for the First Paper Feed Station (Same as
Master Counter)
BCD
0801CC
0801CD
↓
3
Jam counter for the Second Paper Feed Station (Same
as Master Counter)
BCD
0801CF
0801D0
↓
3
Jam counter for the Third Paper Feed Station (Same as
Master Counter)
BCD
0801D2
0801D3
↓
3
Jam counter for the Fourth Paper Feed Station (Same as
Master Counter)
BCD
0801D5
0801D6
↓
3
Jam counter for the Fifth Paper Feed Station (Same as
Master Counter)
BCD
0801D8
0801DC 1
0801F0
↓
25
Daylaight Saving Time (Summer Time) Feature
01H: Enabled
ISDN G4 TID (No data is programmed: FFH) Ascii
Hex
080208
080209 1 Number of ISDN G3-CSI characters Hex
- 3 -
September 14th, 1994
Address Byte Definition Notes
08020A
↓
21
ISDN G3-CSI (20 characters + stop code: FFH) Ascii
08021E
080223
↓
4
ISDN international dial prefix (No data is programmed:
FFH)
Hex
080226
08024F
↓
4
ISDN G4 subaddress (No data is programmed: FFH) Ascii
080252
080253
↓
4
ISDN G3 subaddress (No data is programmed: FFH) Ascii
080256
0802A0
↓
3
Printed page counter for the First Paper Feed Station
(Same as Master Counter)
BCD
0802A2
0802A3
↓
3
Printed page counter for the Second Paper Feed Station
(Same as Master Counter)
BCD
0802A5
0802A6
↓
3
Printed page counter for the Third Paper Feed Station
(Same as Master Counter)
BCD
0802A8
0802A9
↓
3
Printed page counter for the Fourth Paper Feed Station
(Same as Master Counter)
BCD
0802AB
0802AC
↓
3
Printed page counter for the Fifth Paper Feed Station
(Same as Master Counter)
BCD
0802AE
0802AF
↓
3
PC printer output counter BCD
0802B1
0802C0
0802C1
0802C2
0802C3
0802C4
0802C5
0802C6
↓
2
2
2
17
Remote ID: Lower byte (Default= 00H)
BCD
Upper byte (Default= 00H)
Skip length for Specified Image Area feature Unit: mm Hex
Scan length for Specified Image Area feature Unit: mm Hex
Excessive jam calls (Refer to section 4.6 in the service
Hex
manual for details)
0802D6
0802D7
↓
10
Periodic service call (Refer to section 4.6 in the service
manual for details)
Hex
0802E0
0802E1
↓
3
Effective term of service calls (Refer to section 4.6 in the
service manual for details)
Hex
0802E3
- 4 -
September 14th, 1994
Address Byte Definition Notes
0802EC 1
Selection of the the paper feed station in printer mode
[00 - 04H] Default: 00H (First paper feed station)
Hex
080300 1 RAM reset level 1 (Same as address 080000H) Hex
080301
↓
156
NCU Parameters (Refer to section 4.4 in the service
manual for details)
Hex
08039C
080450 1
08045A
↓
Details of the current Auto Service Calls (Refer to section
4.3 in the service manual for details)
PM call (Refer to section 4.6 in the service manual for
3
details)
Hex
Hex
08045C
08047F 1
08D058 1
Clear the error flag for the Fusing Unit Failure (Refer to
section 4.3 in the service manual for details)
Reason for the Auto Service Call (Refer to section 4.3 in
the service manual for details)
084D6F 2,048 Tel number for Quick Dial 01 to 64; 32 bytes for each
Hex
Hex
BCD
number
Refer to the "Tel number table description" to analyse the
data.
<Tel Number Table Description>
Header (16 bytes)
Tel number (15 bytes)
The number is stored using BCD.
Not used (1 byte)
[BCD Description]
BCD Meaning
0
↓
9
0
↓
9
A *
B #
C • (Tone)
D – (Pause)
E / (Sub Address)
F Stop Code
32 bytes
08556F 3,200
Tel number for Speed Dial 00 to 99; 32 bytes for each
number
Refer to the "Tel number table description" to analyse the
data.
- 5 -
BCD
September 14th, 1994
Address Byte Definition Notes
0861EF 320
AI Redial (10 numbers); 32 bytes for each number
Refer to the "Tel number table description" to analyse the
BCD
data.
08632F 160
Tel number for Forwarding (5 numbers); 32 bytes for
each number
Refer to the "Tel number table description" to analyse the
BCD
data.
0863CF 32
Service Station number for Auto Service Call (1 number)
Refer to the "Tel number table description" to analyse the
BCD
data.
0863EF 32
Next Transfer Station number (1 number)
Refer to the "Tel number table description" to analyse the
BCD
data.
08640F 32
Own Tel number (1 number)
Refer to the "Tel number table description" to analyse the
BCD
data.
08644F 32
ISDN G3 (Main) Subscriber number (1 number)
Refer to the "Tel number table description" to analyse the
BCD
data.
08646F 32
ISDN G3 (Sub) Subscriber number (1 number)
Refer to the "Tel number table description" to analyse the
BCD
data.
08648F 32
Own Tel number for ISDN G3 (1 number)
Refer to the "Tel number table description" to analyse the
BCD
data.
0864AF 32
ISDN G4 (Main) Subscriber number (1 number)
Refer to the "Tel number table description" to analyse the
BCD
data.
0864CF 32
ISDN G4 (Sub) Subscriber number (1 number)
Refer to the "Tel number table description" to analyse the
BCD
data.
0864EF 32
Own Tel number for ISDN G4 (1 number)
Refer to the "Tel number table description" to analyse the
BCD
data.
08650F 2,112
Temporary Tel number (66 numbers); 32 bytes for each
number
Refer to the "Tel number table description" to analyse the
BCD
data.
087D3F 1,344 Label for Quick Dial 01 to 64 (21 bytes for each number) Ascii
08827F 2,100 Label for Speed Dial 00 to 99 (21 bytes for each number) Ascii
08AE0D 512
08B00D 800
Dedicated Tx Parameters - Quick Dial 01 to 64 (8 bytes
for each number)
Dedicated Tx Parameters - Speed Dial 00 to 99 (8 bytes
for each number)
Hex
Hex
- 6 -