Parts catalog correction To meet standards ( ) To facilitate assembly
Vender change Part standardization To improve reliability
Other
To improve the fusing availability.
If a printer I/F option is installed, please replace the following parts at the same time to realize the good
copy quality.
<CS1>Check Sum
H511 6026CH511 6026DPCB-MBU
H511 7140CH511 7140D
<CRO USA>
H510 6100HH510 6100JPCB-FCU
H510 7140CH510 7140D
Programmed ROM
Programmed ROM
Q’ty Used
Old → New
1 → 1
1 → 1
1 → 1
1 → 1
Interchange-
ability
X/O481-5
X/OD5FF----
X/O491-5
X/O8E41----
Remarks
S.Hamano
Assistant General Manager
2nd T.S.Sec. Int’l Marketing Group
Parts Catalog
Index No. Page
DETAILS OF MODIFICATION
Page 2/2
MODIFICATION BULLETIN NO. Cseries-0 07ISSUED ON 24th, Dec. 1993
No.Description
1
Cable equalizer for transmission was inco rrect .
2
When a personal code from 2000 to 2099 was u sed , the code was not printed out on the TCR.
3
When Legal and B5 paper are place d in th e cassettes, the Two in One functio n did not work.
4
Sometimes, the inco rrect time was printed when using the Reception Time feature.
5
The machine stopped printing after the cassette was pulled out and replaced between pages during reception.
6
Improvement of the Ordering Toner function .
7
Change of threshold value for halftone.
8
Modification of time interval betwe en CNG signals.
9
Wording change from [EM MANUAL CALL] TO [PM MANUA L CALL] .
When there is no end mark on the OMR sheet, the ma chin e no w indica tes on the LCD that the program could not be done
10
correctly.
11
In forwarding mode, when the machine is out of paper, the Receive File Indicator is not turned on.
12
When the time delay caused by echo is more tha n 400 ms, V2 9 sign als cannot be detected.
13
The machine sometimes do es not print out when the machine receives more than 16 pages in Two in One mode.
When the machine is in subst itu te reception, and if the casset te is pulled out and replaced during reception, the file is not
14
printed out.
15
Improvement of reliabilit y for OMR op era tion.
16
PM call does not work properly if the PM int erva l is cha nged from 10 mont hs to 15 mon th s.
17
The On Line Indicator is not correct when the Night Timer is switch ed on.
18
The Rx equalizer on the PCB is always on.
19
Time for detecting on-hook is n ow cha ng eable (countermeasure for NTT D23 Crossbar exch ange r).
20
Printing is slow when printing contin uosly in print er mod e.
21
Addition of software concernin g the new modem (Rockwell 14 4EFXL).
22
Communication mode display is not correct du ring V17 commun icat ion.
Applied Model
CS1CRO
O
OO
O
O
OO
OO
OO
OO
OO
O
O
O
O
OO
O
OO
OO
O
OO
O
O
O
MODIFICATION BULLETIN NO. Cseries-0 08ISSUED ON 24th, Dec. 1993
Page 1/1
Model
Modified ArticleProgrammed ROMExecution Date
Reason for
Modification
Old Part No.New Part No.Description
<CRO Europe>
H510 6101FH510 6101GPCB-FCU
H510 7130BH510 7130CProgrammed ROM
<CRO Asia>
H510 6102EH510 6102FPCB-FCU
H510 7132BH510 7132CProgrammed ROM
CRO (Europe, Asia)
Parts catalog correction To meet standards ( ) To facilitate assembly
Vender change Part standardization To improve reliability
Other
[Reasons for Modification]
1.When a personal code from 2000 to 2099 was used, the code was not printed out on the TCR.
2.Wording change from [EM MANUAL CALL] TO [PM MANUAL CALL].
3.Time for detecting on-hook is now changeable (countermeasure for NTT D23 Crossbar exchanger).
MODIFICATION BULLETIN NO. Cseries-014ISSUED ON Feb. 1st, 1994
ModelCSODate of Modi fica tion
Mod i fied ArticleLD Unit C ove rExecution Date
Reason for
Modification
P arts catalog co rrection To meet standards ( ) To fa cilitate a s sembly
Vender change Part standardization To improve reliability
Other
After the old parts have become out
of s t ock .
Page 1/1
Old Part No.New Part No.Description
H0812524H0812529
LD Unit C ove r
Q’ty Used
Old → New
1 → 1O/O681-11
Interchange-
ability
Remarks
Parts Catalog
Index No. Page
S.Hamano
Assistant General Manager
2nd T.S.Sec. Int’l Marketing Group
MODIFICATION BULLETIN NO. Cseries-015ISSUED ON Feb. 1s t, 1994
ModelCSO, CFO, CRO, CS1 (All models)Date of Modi fica tion
Mod i fied ArticleSt opper - Right Casse t t e.Execution Date
Reason for
Modification
P arts catalog co rrection To meet standards ( ) To fa cilitate a s sembly
Vender change Part standardization To improve reliability
Other
After the old parts have becam e out
of s t ock .
Page 1/1
Old Part No.New Part No.Description
H0813588H5133588
St opper - Right Casse t t e
Q’ty Used
Old → New
1 → 1O/O761-11
Interchange-
ability
Remarks
Parts Catalog
Index No. Page
S.Hamano
Assistant General Manager
2nd T.S.Sec. Int’l Marketing Group
MODIFICATION BULLETIN NO. Cseries-016ISSUED ON Feb. 1s t, 1994
ModelCSO/ CFO (All models)Date of Modi fica tion
Mod i fied ArticleFacsimile F eatures Manual (French)Execution Date
Reason for
Modification
P arts catalog co rrection To meet standards ( ) To fa cilitate a s sembly
Vender change Part standardization To improve reliability
Other
After the old parts have become out
of s t ock .
Page 1/1
Old Part No.New Part No.Description
H0824709H5104709
Facsimile Features M anual
Q’ty Used
Old → New
1 → 1O/O-------
Interchange-
ability
Remarks
Parts Catalog
Index No. Page
S.Hamano
Assistant General Manager
2nd T.S.Sec. Int’l Marketing Group
MODIFICATION BULLETIN NO. Cseries-017ISSUED ON Feb. 1st, 1994
ModelCSO (Europe)Date of Modi fica tion
Mod i fied ArticleFacsimile F eatures Manual - E nglish, GermanyExecution Date
Reason for
Modification
P arts catalog co rrection To meet standards ( ) To fa cilitate a s sembly
Vender change Part standardization To improve reliability
Other
After the old parts have become out
of s t ock .
Page 1
Old Part No.New Part No.Description
< English>
H0824707H5104707Facsimile Features Manual (Eng)1 → 1O/O-------
< Germany>
H0824706H5104706Facsimile Features Manual (G)1 → 1O/O-------
Q’ty Used
Old → New
Interchange-
ability
Remarks
Parts Catalog
Index No. Page
S.Hamano
Assistant General Manager
2nd T.S.Sec. Int’l Marketing Group
MODIFICATION BULLETIN NO. Cseries-018ISSUED ON Feb. 1st, 1994
ModelCS1Date of Modi fica tion
Mod i fied ArticlePROMExecution Date
Reason for
Modification
P arts catalog co rrection To meet standards ( ) To fa cilitate a s sembly
Vender change Part standardization To improve reliability
Other
Countermeasure for the following problem.
The machine may not work correctly when it receives a B5 size (182 X 257mm) image in detail mode if the
2 in 1 feature is switched on.
S.Hamano
Assistant General Manager
2nd T.S.Sec. Int’l Marketing Group
Parts Catalog
Index No. Page
MODIFICATION BULLETIN NO. Cseries-019ISSUED ON Feb. 25th, 1994
ModelCFODate of Modif ication
Mod i fied ArticlePCB - Op-portExecution Date
Reason for
Modification
P arts catalog co rrection To meet standards ( ) To fa cilitate a s sembly
Vender change Part standardization To improve reliability
Other
The PCB - Op-port is no longer available to be supplied as a service part.
Please order the Op-port unit instead of the PCB - Op-port.
< Reason>
1.W e can not assure qua lity w hen t r ansporti ng or replacing the PCB.
*The PCB-op-port contains five PCBs and each PCB is connected by a flat cable. The flat cable may be
damaged by transporting or replacing.
*If the edges of the push switches for each key are pushed when transporting or replacing, the part
may be broken.
2.The price of the PCB -OP-Port is almost the same a s the OP-Port unit.
Page 1/1
Old Part No.New Part No.Description
H082 6005
H082 4120Op-port unit : H082-20
H082 4151Op-port unit : H082-51
H082 4175Op-port unit : H082-21
H082 4176
H082 4199Op-port unit : H082-52
H082 6025PCB - Op-port : E1 → 031-5
H082 4140Op-port unit : H082-40
H082 4145
H082 4195Op-port unit : H082-90
PCB - Op-port : USA, A
Op-port unit : H082-22
Op-port unit : H082-30
Q’ty Used
Old → New
1 → 031-5
Interchange-
ability
Remarks
Parts Catalog
Index No. Page
S.Hamano
Assistant General Manager
2nd T.S.Sec. Int’l Marketing Group
MODIFICATION BULLETIN NO. C series-020ISSUED ON April, 5th, 1994
ModelCS1 all modelsDate of Modi fica tion
Mod i fied ArticlePCB - FCUExecution Date
Reason for
ModificationFrom Feb. 1994 production
P arts catalog co rrection To meet standards ( ) To fa cilitate a s sembly
Vender change Part standardization To improve reliability