Action required
Service manual revision
Retrofit information
No.:
K. Misugi
RH547001
This RTB informs the changes made to the G4 (SiG4) unit software and corrections to the
Schmidt3 ISDN Unit service manual.
CHANGES MADE TO THE DEFAULT SETTINGS
1.
The following changes have been made from the first production of August.
Bit Switch 13: D channel layer 3 (Attachment IE in S: SETUP)
FUNCTIONCOMMENTS
0:
Condition for fallback from G4 to
G3
0:
Refer to the CPS code setting
1:
7
Fallback in response to any
CPS code
Fallback occurs when a CPS code is the
same as the CPS code settings specified by
G4 internal switches 17, 18, 1A, 1B, and 1C.
If you wish to enable fallback when any CPS
code is detected, set this bit to “1.”
This switch is effective in coping with fallback
problems where the CPS code does not match
those specified in the ITU-T recommendation.
The new default setting is “1.”
Communication Switch 07
NoFUNCTIONCOMMENTS
0:
Fallback from G4 to G3 reflected
in programmed Quick/Speed dials
3
0:
Fallback enabled (Default)
1:
Always start with G4
If a communication falls back from G4 to
G3, the machine will always start transmission
with G3 from the next communication.
1: The machine will always start to transmit
with G4.
The new default setting is “1.”
The default settings have been changed to cope with fallback problems where CPS codes
do not match those specified in the IT U-T recommendations. If you are installing machines
that were manufactured earlier than August, it is recommended to change the settings as
explained above to avoid communication problems.
NOTE:
PCB part numbers: H5476170G (Europe/Asia models), H5476180F (USA model)
Please also refer to MB No. MH547001 for part number information.
Page 2
RICOHTechnical
Bulletin
PAGE: 2/3
Model:
Schmidt3
Date:
31-Oct-99
2. NEW SWITCH ADDED TO THE G4 UNIT
The following changes have been made from the first production of August.
G4 Internal Bit Switch 13
NoFUNCTIONCOMMENTS
1:
Information transfer capability
shift down to retry transmission
0:
Shiftdown procedure disabled
(Default)
1:
Shiftdown and retry the call
1
The mac hine changes the ISD N G3
information transfer capability informed in the
[SETUP] signal to “Speech” from “3.1 kHz
audio” or to “3.1 kHz audio” from “Speech”
automatically and retries the transmission.
The information transfer capability used in the
first try is determined by the setting of G4
internal bit switch 14 bit 0.
This switch is effective with some types of
exchangers and T/As where they only accept
calls with information transfer capability
“Speech.”
No.:
RH547001
- Cross reference -
G4 Internal Bit Switch 14
NoFUNCTIONCOMMENTS
ISDN G3 information transfer
capability
0:
3.1 kHz audio
1:
0
Speech
In tx mode, this determines the information
transfer capability informed in the [SETUP]
message.
In rx mode, this determines the information
transfer capability that the machine can use to
receive a call.
Set this bit to 1 if the ISDN does not support
3.1 kHz audio.
NOTE:
PCB part numbers: H5476170G (Europe/Asia models), H5476180F (USA model)
Please also refer to MB No. MH547001 for part number information.
Page 3
RICOHTechnical
Bulletin
PAGE: 3/3
Model:
3. CORRECTION TO THE SCHMIDT 3 ISDN UNIT SERVICE MANUAL
ISDN G3 information transfer
capability for transmission
0:
3.1 kHz audio
1:
Speech
ISDN G3 information transfer
capability for transmission
Bit 3 2 Setting
0 0 Speech
0 1 3.1 kHz audio
1 0 Not used
1 1 Same as the G4 internal
switch 14 bit 0 setting.
This determines the information transfer
capability informed in the [SETUP] message.
Set this bit to 1 if the ISDN does not support
3.1 kHz audio.
This determines the information transfer
capability informed in the [SETUP] message.
Set this bit to 1 if the ISDN does not support
3.1 kHz audio.
Date:
31-Oct-99
No.:
RH547001
Page 4
RICOHTechnical
Bulletin
PAGE: 1/1
Model:
Subject:
From:
Classification:
Schmidt 3
Group dials display on RDS
Technical Service Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
Date:
Prepared by:
Part information
Electrical
Transmit/receive
31-Oct-99
Action required
Service manual revision
Retrofit information
No.:
RH547002
K. Moriizumi
SYMPTOM
RDS displays groups 8, 9, 24 and 25 for Quick Dial 01 after the dial data is read from the
Schmidt 3. However, groups 8, 9, 24 and 25 are actually not programmed in Quick Dial
01, as the Schmidt 3 can only hold a maximum of seven groups.
SOLUTION
Change the software.
Temporary firmware will be issued (version 045).
Check Sum values
Total :1F14
Boot : 5123
Main : CDF1
Files
For Flash Card:
File nameH547W045.BIN
For RDS:
File nameH547W045.FRH/H547W045.LZ
Page 5
RICOHTechnical
Bulletin
PAGE: 1/1
Model:
Subject:
From:
Classification:
Symptoms
Cause
Schmidt3
Communication Problem
Technical Services Dept., GTS Division
Troubleshooting
Mechanical
Paper path
Other ( )
While receiving or transmitting, the line is disconnected or the machine
-
malfunctions.
Result “E” or “D” is printed on the TCR.
-
The above symptom does not always appear.
This appears depending upon the D-RAM on the FCU.
When “60” appears at some addre ss of the D-RAM accidentally after the power is
turned on (or goes back from the energy saver mode), the above symptom appears.
The symptom does not appear on most machines but there are some machines which
are susceptible to communication problems.
Part information
Electrical
Transmit/receive
Date:
31-Dec-99
Prepared by:
Action required
Service manual revision
Retrofit information
No.:
Y. Okunishi
RH547003
Action taken
Replace the ROM with the new one (H5477200H or later version).
RCREBVASIA
** *