Spec
No.
29
0 0 0 0
Digital Tare Rounding
0 : Tare Exactly
1 : Round to Nearest
Increment
30 Load Cell Sensitivities Selection (mV/V) (Scale 1)
SPC MIN MAX SPC MIN MAX SPC MIN MAX SPC MIN MAX
auto
adjust-
ing
1 0 0 1
0000
0001
0010
0011
31 Load Cell Sensitivities Selection (mV/V) (Scale 2)
SPC MIN MAX SPC MIN MAX SPC MIN MAX SPC MIN MAX
auto
adjust-
ing
1 0 0 1
32
1 0 1 0
33
0000
0001
0010
0011
Calibration Mode
protected by Span
Switch
0 : Yes 1 : No
Over Weight Mask at
0 : +1d
1 : +9d
0 _ _ _
34
NOT USED
0 0 0 0
35
NOT USED
0 0 0 0
36
00 : 2 10 : 5
01 : 1 11 : 10
_ _ 0 0
37 Load Cell Sensitivities Selection (mV/V) (Scale 3)
SPC MIN MAX SPC MIN MAX SPC MIN MAX SPC MIN MAX
auto
adjust-
ing
1 0 0 1
38
0000
0001
0010
0011
(For Scale 3)
0 :For Std / Normal
Load Cell
1: For abnormal load
cell with too large
0 0 1 0
39
NOT USED NOT USED
0010
Bit 3 Bit 2 Bit 1 Bit 0
3.46
3.00
2.59
2.25
3.46
3.00
2.59
2.25
4.00
3.46
3.00
2.59.
4.00
3.46
3.00
2.59.
Tare Value Exchange
0 : Yes
1 : No
0100
0101
0110
0111
0100
0101
0110
0111
1.95
1.69
1.46
1.27
1.95
1.69
1.46
1.27
Battery Low Lamp
BATTERY 1
0: Yes
1: No
2.25
1.95
1.69
1.46
2.25
1.95
1.69
1.46
Tare Addition
0 : Yes
1 : No
1000
1001
1010
1011
1000
1001
1010
1011
1.09
0.95
0.82
0.71
1.09
0.95
0.82
0.71
1.27
1.09
0.95
0.82
1.27
1.09
0.95
0.82
Auto Exit from Add
Mode
0 : No
1 : Yes
Tare Subtraction
0 : Yes
1 : No
1100
1101
1110
1111
1100
1101
1110
1111
0.61
0.53
0.46
0.40
0.61
0.53
0.46
0.40
External Load Cell
(Scale 3)
0: No
1: Yes
Weight Decimal Point Position (Scale 3)
000 : 00000 011 : 00.000
001 : 0000.0 100 : 0.0000
010 : 000.00
(For Scale 1)
0 :For Std / Normal Load
Cell
1: For abnormal load cell
with too large offset.
00 : Normal
01 : Prevent from Small vibration/ fast change in
display
10 : Prevent from Medium vibration
A/D Board (Scale 1)
11 : Prevent from Large
slow change in display
(For Scale 2)
0 :For Std / Normal Load
Cell
1: For abnormal load cell
with too large offset.
00 : Normal
01 : Prevent from Small vibration/ fast change in
display
10 : Prevent from Medium vibration
A/D Board (For Scale 2)
11 : Prevent from Large
slow change in display
Minimum Display ( Scale 3)
A/D Board (For Scale 3)
00 : Normal
01 : Prevent from Small vibration/ fast change in
display
10 : Prevent from Medium vibration
11 : Prevent from Large
slow change in display
3.46
3.00
2.59
2.25
4.00
3.46
3.00
2.59.
0100
0101
0110
0111
Digital Tare When Loaded
0: Allow
1:Not Allow
1.95
1.69
1.46
1.27
2.25
1.95
1.69
1.46
1000
1001
1010
1011
1.09
0.95
0.82
0.71
Internal Count
0 : 500,000
1: 1,000,000
1.27
1.09
0.95
0.82
1100
1101
1110
1111
0 : Yes
0.61
0.53
0.46
0.40
Stability Check When
Changing Scales
1 : No
offset
REZERO WHEN
CHANGING SCALE
(V2.15+)
0: No
1: Yes
DMC-290 DATA SHEET
-
0.71
0.91
0.53
0.46
END USER:
OPTIONS
SCANNER S/N:
PRINTER S/N:
CUSTOM FORMAT
Sales Order No.
Customer
Technician
Date
FUNCTIONAL TEST FUNCTIONAL TEST
0.71
0.91
0.53
0.46
0.71
0.91
0.53
0.46
1 KEYBOARD ENTRY 16 SET POINT ITEM 1 2 3 4 5 6
2 DIGITAL TARE 17 SET POINT GEN. 1 2 3 4 5 6
3 TARE 18 OVERRANGE BLANKING
4 AUTO TARE CLEAR [ON] [OFF] 19 AUTO POWER OFF MIN.
5 LB / KG SWITCH 20 DATE SETTING
6 NEGATIVE COUNT 21 APPEARANCE
7 RECOMPUTE 22 BAR CODE READER SCANNER PEN
8 MEMORY STORAGE 23 SPEC SWITCH SETTING [ON] [OFF]
9 AUTO UNIT WT CLEAR [ON] [OFF] 24 MEMORY CLEANED
10 INSUFFICIENT SAMPLE 25 MAIN BOARD S/N T.H.A. #
11 ACCUMULATE 26 A/D NO. # LOT NO #
12 BATTERY (MEMORY BACKUP) [ON] [OFF]
13 BATTERY POWER SWITCH [ON] [OFF] REZERO 1-4-1
14 SOFTWARE VERSION
15 RS-232 PORT
PLATFORM / SCALE 1 APPLIED DISPLAY
S/N 0
Model 1/4
Capacity 1/2
Grads 3/4
Zero count Full
PLATFORM / SCALE 2 APPLIED DISPLAY
S/N 0 INSTRUCTION MANUAL QUICK GUIDE
Model 1/4 SPIDER 1. 2. 3. 4.
Capacity 1/2 PLATTER 1. 2. 3. 4.
Grads 3/4 POWER CORD UNLOCKING TOOL
Zero count Full PACKED BY CHECKED BY
00 14 27
01 15 28
02 16 29
03 17 30
04 18 31
05 19 32
06 REZERO 1-4-2 33
07 20 34
08 21 35
09 22 36
10 23 37
11 24 38
12 25 39 - - - -
.C. LIST -
13 26
✓✓✓✓
PLATFORM / SCALE 3 APPLIED DISPLAY PLATFORM / SCALE 4 APPLIED DISPLAY
S/N 0 S/N 0
Model 1/4 Model 1/4
Capacity 1/2 Capacity 1/2
Grads 3/4 Grads 3/4
Zero count Full Zero count Full
Ver. 3.20 Customer Specification
: To enter this mode, press the following key
sequence : [R][1][4][1] ie. Numeric keys 1, 4 ,1 while holding Rezero key.
Spec No. Bit 3 Bit 2 Bit 1 Bit 0
0
Tare When
Change Scale
0 = Old Tare
1 = New Tare
Digital Tare
Accumulation
0 = No
1 = Yes
Terminator
0 = Carriage
Return
1 = Carriage
Return Linefeed
(RS-232only)
1
0 0 0 0
2
1 0 0 0
3
0 1 1 1
4
1 0 0 1
5
1 0 1 1
6
1 1 0 1
7
0 0 0 0
8
0 0 1 0
9
0 1 1 1
10
0 1 1 1
11
0 1 0 0
0000 : Auto Power Off Disable when Net Wt. = 0
0001 ~ 1111 : Duration to activate Power Off (in Minutes). (1 to 15 minutes)
Scale Specification
00 : Gram 01 : Kg
10 : Lb 11 : not used
RS-232 port commands
00 = standard RS-232
01 = ctm-290 (slip printer)
10 = tm-200( with cutter command)
11 = tm-200(with feed for tear off)
Set New Item
Code during
Normal Mode
0: Yes 1: No
Sampling time
for Unit Weight
Calculation
0 : 10 times
1 : 5 times
Display
Accuracy of Unit
Weight
0 : No
1 : Yes
Set Point Buzzer
0 : Yes 1 : No
Insufficient sample Level
00 : 0.1 %
01 : 0.2%
10 : 0.0%
Unit Wt. Auto
Re-computing
0 : No
1 : Yes
Clear All Input
Key in One
Touch
0 = Yes
1 = No
Set Points:
0: Latch
1: No Latch
RS-232C
(Connection
(Force Balance)
0 : No 1 : Yes
RS-232C (FB)
Stop Bit
(Optional)
0 : 1 bit 1 : 2 bits
RS-232C
Connection
(PC / Printer)
0 : No 1 : Yes
RS-232C
(PC/PRN)
Stop Bit
(Optional)
0 : 1 bit
1 : 2 bits
RS-232C (FB)
Data Length
(Optional)
0 :7 bits1 : 8 bits
Force Balance
Type
0: SHG-300
1: TP-200
RS-232C (PC/PRN)
Data Length
(Optional)
0 :7 bits 1 :8 bits
PRINTER:
0: Eltron or Epson
1: BCP-30
0 = output on RS-232
comma delimited file
1 = paper tape output
Power Auto Off Function
Kg/Lb Lamp Inhibit
0 : No
1 : Yes
Print commands
00 = bcp-30 (barcode printer)
01 = ctm-290 (slip printer)
10 = tm-200( with cutter command)
11 = tm-200(with feed for tear off)
Date Order
00:Year, Month, Date
01: Date, Month, Year
11: Month, Date, Year
RS232 Continue
Sending High
0 = High
1 = Low
00 : %Quantity 10 : Quantity
01 : %Weight 11 : Weight
RS-232C (FB) Baud Rate
00:1200 10 4800
01:2400 11 9600
RS-232C (FB) Parity Bit
00 : No 10 : Not Used
01 : Odd 11 : Even
00 : 1200 10 : 4800
01 : 2400 11 : 9600
00 : No 10 : Not Used
01 : Odd 11 : Even
on printer port (in prog mode)
12
1 0 1 0
13
0 0 0 1
RS-232 (PC/PRN) Output
(Optional)
00 : Not Available
01 : When Counting Condition(PC)
10 : By ∗∗∗∗ Key
11 : In Both Cases (DP122)
RS232(PC/PRN)
Header:
0: Code
1: Title
RS232 CONNECTOR
Sub
Din Sub Din
000 : Printer .......... Force Bal. 101 : Force Bal ........PC
001 : Force Bal. ......Printer 010 : Printer .............PC (*1)
100 : PC ..................Force Bal. 011 : PC ...............Printer(*2)
Eltron format
0 = eltron fixed
format
1 = custom
download format
Weighing unit
0= U.W. per/1000
1 = A.P.W.
Inventory Disp by Gross Key
0: Gross Disp
1: No of Invnt
Negative Counting
0 : No
1 : Yes
Auto Shift To Next Position
After Two Key of Teraoka Code
Entry
0 = No 1 = Yes
Set Point Type
(Optional)
(Optional)
RS-232C (PC/PRN) Baud Rate
(Optional)
RS-232C (PC/PRN)Parity Bit
(Optional)
RS232C (PC/PRN)
With Header
0: Yes
1: No
14
1 0 1 0
15
0 0 1 1
16
normally
set
0 0 0 1
_ _ _ _
17
normally
set
1 0 1 1
_ _ _ _
RS-232C
Connection
(Barcode Pen)
0 : No 1 : Yes
RS-232C (BCP)
Stop Bit
(Optional)
0 : 1 bit 1 : 2 bits
SCALE 1:
00: Internal Scale 1
01: Internal Scale 2
10: External Scale
11: Force Balance
SCALE 3:
00: Internal Scale 1
01: Internal Scale 2
10: External Scale
11: Force Balance
RS-232C (BCP)
Data Length
(Optional)
0 :7 bits1 : 8 bits
RS232C (BCP)
With Header
0: Yes
1: No
RS-232C (BCP) Baud Rate
(Optional)
00 : 1200 10 : 4800
01 : 2400 11 : 9600
RS-232C (BCP)Parity Bit
(Optional)
00 : No 10 : Not Used
01 : Odd 11 : Even
SCALE 2:
00: Internal Scale 1
01: Internal Scale 2
10: External Scale
11: Force Balance
SCALE 4:
00: Internal Scale 1
01: Internal Scale 2
10: External Scale
11: Force Balance
ALL SCALES ARE UNIQUE AND EACH MUST HAVE THEIR OWN CHANNEL LOCATION.
18
0 0 0 0
19
0 0 0 0
Weight and Measures Specification
pressing the Rezero Key. The Span Switch must be “ON” to enter this mode.
Set Point TTL Output
0: Active Low
1: Active High
Number Of Set Point:
000: 2 Set Points
001: 3 Set Points
Display “Not F” Message For
Items Not Stored In Memory
0 : Yes 1 : No
: To enter this mode, enter the numeric keys 1,4,2 while
Link To IMS
0 = NO
1 = YES
010: 4 Set Points
011: 5 Set Points
100: 6 Set Points
Type of Force
Balance (Japan
Version Only)
0: SHG-300
1: HR-60
Print When
Pressing + or –
key in Add Mode
0: yes
1: No
Spec No. Bit 3 Bit 2 Bit 1 Bit 0
20
_ _ _ _
21
_ _ _ _
22
_ _ _ _
23
0 0 1 1
24
0 0 0 0
25
0 0 _ 0
26
0 0 1 1
27
0 1 0 0
28
0 0 0 0
00 : 2 10 : 5
01 : 1 11 : 10
00 : 1/10,000 10 : 1/2,500
01 : 1/5,000 11 : Not Used
Masked Display at
Minus Wt.
0 : Gross
1 : Net
Scale Starting
Method
0 : Automatic
1 : Manual
Zero Tracking
When Tare
0 : Yes 1 : No
Comma Display
0 : No
1 : Yes
Auto Tare clear
when Rezero
0 : No
1 : Yes
Minimum Display ( Scale 1)
000 : 00000 011 : 00.000
001 : 0000.0 100 : 0.0000
010 : 000.00
000 : 00000 011 : 00.000
001 : 0000.0 100 : 0.0000
010 : 000.00
Display Resolution
Display at Minus Wt.
0 :Minus
Display
1 :Masked
IR Mode protected by
Span Switch
0 : No
1 : Yes
Weight Reset when
Tare
0 : Yes 1 : No
Digital Tare Setting
0 : No 1 : Yes
Automatic Unit Weight Clear Condition
00 : Over Net 5d and Gross 21d
and Weight Stable
01 : >= Net 1d and Weight Stable
10 : >= Net 1d and Quantity >0
and Weight Stable
00 : 2 10 : 5
01 : 1 11 : 10
Weight Decimal Point Position (Scale 1)
Weight Decimal Point Position (Scale 2)
00 : Unlimited 10 : +- 10% FS
- 10% F.S.
01 : +- 2% FS 11 : Unlimited
Zero Lamp
Lighting Method
0 : Gross
1 : Net
Scale Type
0 : Single Scale
1 : Double Scale
Initial Start Range
00 : Unlimited 10 : +- 10% FS
- 10% FS
01 : +- 2% FS 11 : Unlimited
00 : 100%FS 10 : 5% FS
01 : 50%FS 11 : Unlimited
Minimum Display (Scale 2)
Zero Setting Range
When No AC, Display Mask When
Battery Low or No Battery.
0 : Yes 1 : No
Gross Mode Available
0 : Yes
1 : No
Tare Range
Automatic Unit Weight Clear
0 : No