Rheem PVS 40-P36LP, PVS 40-36NAT, PVS 50 P-33LP, PVS 40-33NAT, PVS 40-P33LP User Manual

...
Rheem PowerVent Induced Draft Gas Water Heater with the Guardian System
Guardian System
Air/fuel shut-off system offers double protection
Maintenance free – no filter to clean
Protective control system that disables the heater in the presence of flammable vapour accumulation
Flexible Venting Options
Long venting lengths up to 100 feet
PVC, ABS, or CPVC vent pipe options
Vertical or horizontal termination
New Quiet Blower
Less noise than ever before
Self-Diagnostic System
Integrated self-diagnos­tic system control takes the guess work away
Environmentally Friendly Burner
Low NOx design for low nitrous oxide emissions
High Altitude Compliant
Models certified up to 4,500 feet above sea level
Self-Cleaning
EverKleen™patented system fights sediment build-up
Reduces fuel costs
Provides more hot water
Longer Life
Patented magnesium anode rod design incorporates a special resistor that protects the tank from corrosion.
Provides longer tank life than using standard magnesium anode rods
**
See Residential Warranty Information Brochure for complete warranty information.
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
NEW
HT.TO HT.TO WATER HT.TO WATER
PREVIOUS FVIR FIRST HOUR TOP OF TANK GAS CONN. SIDE T&P CONN. SHIP. ENERGY
GALLON / LITRE MODEL MODEL GAS INPUT IN RECOVERY IN DEL. G.P.H. ASSEMBLY HT. DIAM. CONN. CNTR. VALVE SIZE WT. FACTOR
CAPACITY NUMBER NUMBER THOUS. BTU/HR. G.P.H. 100° RISE NAT. A B C D E F G (LBS) NATURAL
40 / 151 PVS40-36 PVS40-36FV 36 30.5 67 61-1/2 50-1/2 20-1/4 14 8 44 3/4 152 0.59
40 / 151 PVS40-36P PVS40-34PFV 34 28.8 67 61-1/2 50-1/2 20-1/4 14 8 44 3/4 152 0.59
50 / 189 PVS50-36 PVS50-36FV 36 30.5 80 61-1/2 50-1/2 22-1/4 14 8 44 3/4 176 0.58
50 / 189 PVS50-36P PVS50-34PFV 34 28.8 80 61-1/2 50-1/2 22-1/4 14 8 44 3/4 176 0.58
CROSS REFERENCE AND SPECIFICATIONS
VENTING INFORMATION FOR 2" VENTS
NUMBER OF MINIMUM MAXIMUM
90° ELBOWS NUMBER PIPE PIPE
WITH VENT OF 45° LENGTH LENGTH
TERMINAL ELBOWS REQ. (FT.) (FT.)
One (1) None 4.0 44.0
One (1) One (1) 4.0 41.0
Two (2) None 4.0 38.0
Two (2) One (1) 4.0 35.0
Three (3) None 4.0 32.0
For the 2" vent, one 90° elbow is approximately equal to 6 feet of pipe. One 45° elbow is approximately equal to 3 feet of pipe.
VENTING INFORMATION FOR 3" VENTS
NUMBER OF MINIMUM MAXIMUM 90° ELBOWS NUMBER PIPE PIPE
WITH VENT OF 45° LENGTH LENGTH
TERMINAL ELBOWS REQ. (FT.) (FT.)
One (1) None 5.0 95.0
One (1) One (1) 5.0 92.5
Two (2) None 5.0 90.0
Two (2) One (1) 5.0 87.5
Three (3) None 5.0 85.0
Three (3) One (1) 5.0 82.5
Four (4) None 5.0 80.0
Four (4) One (1) 5.0 77.5
Five (5) None 5.0 75.0
For the 3" vent, one 90° elbow is approximately equal to 5 feet of pipe. One 45° elbow is approximately equal to
2.5 feet of pipe.
Rheem Manufacturing Company Water Heater Division Rheem Canada Ltd./Ltée,128 Barton Street West, Hamilton, Ontario L8N 3P3
09/06 WP FORM NO. 101-85CAN
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Available in 40 and 50 US Gallon Models
6-Year Limited Tank Warranty*
1-Year Limited Parts Warranty*
®
POWER VENT
ASSEMBLY
G
HOT
WATER
CONNECTION
B
A
D
1/2"
E
C
WATER
CONNECTION
T&P FITTING
3/4" N.P.T.
F
G
COLD
Loading...