Rheem PROPLUSG5065NRH62PDV Specifications

T
INTEGRATED HOME COMFORT
Professional Classic Plus® Power Direct Vent
INTEGRATED HOME COMFORT
gas water heaters are a perfect choice for tight construction and indoor air quality
Water
Residential Gas
Professional Classic Plus Power Direct Vent Water Heaters
Efficiency
• .65 UEF
• ENERGY STAR
®
rated
Performance
• FHR: 111 gallons for natural and 81 gallons for LP gas
• Recovery: 47.5 to 65.7 GPH at a 90° F rise, based on model
Self-Diagnostic System
• Electronic gas control for improved monitoring and service
Low Emissions
• Eco-friendly burner, low NOx design
Features
• Two pipe system: one pipe pulls in outside air for combustion and the other exhausts combustion gases
• 120 VAC powered blower
• New whisper quiet blower
Flammable Vapor Detection System
• Protective control system that disables the heater in the presence of flammable vapor accumulation
Flexible Venting Options
• Long venting lengths up to 100 feet
• PVC, ABS, or CPVC vent and air inlet options
• Vertical or horizontal vent and iar inlet system configurations
3" and 4" Concentric vent kits available
Longer Life
• Premium grade anode rod provides long-lasting tank protection
High Altitude Compliant
Models are certified for applications up to 10,100 feet above sea level
Plus…
• Enhanced flow brass drain valve
• Temperature and pressure relief valve included
• Low lead compliant
• Durable silicon nitride igniter (HSI)
• Side taps for space heating
• EverKleen
patented system fights
sediment build-up
• Standard replacement parts
Warranty
• 8-Year limited tank and parts warranty*
• With ProtectionPlus™ the 8-year limited tank warranty becomes 12-year
* See Residential Warranty Certificate for
complete information
Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria.
T&P FITTING
3/4" N.P.T.
D
B A
C
1/2"
E
G
SIDE TAPS
Professional Classic Plus
Power Direct Vent
50-Gallon Capacities
Up to 65,000 BTU/h
Natural and LP Gas
LEED Point = 1
See venting information on back.
COMBUSTION
AIR INLET
COMBUSTION
EXHAUST
(VENT)
H
HOT
WATER
CONNECTION
H
COLD
WATER
CONNECTION
I
F
T Y
NOMINAL
P
GALLON
E
CAP.
Tall 50 48 PRO+G50-65N RH62 PDV 65 – 65.7 – 111 – 67-5/8 68-3/8 59-3/8 21-3/4 14 8 52-3/4 3/4 31-1/2 210 0.65
Tall 50 48 PRO+G50-47P RH62 PDV 47 – 47.5 – 81 67-5/8 68-3/8 59-3/8 21-3/4 14 8 52-3/4 3/4 31-1/2 210 0.65
Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements.
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
RATED
GALLON
CAP.
MODEL
NUMBER
GAS INPUT
IN THOUS.
BTU/H
RECOVERY
IN G.P.H.
90° F RISE
UEF
HEIGHT TO TOP
OF
VENT
A
HEIGHT TO TOP
OF AIR
INLET
B
TANK
HEIGHTCDIAM.
FIRST HR.
DEL. G.P.H.
INTEGRATED HOME COMFOR
HT. TO
GAS
CONN.
D
E
HT. TO
WATER
SIDE
CONN.
CNTR.
F
WATER
T&P
CONN.
SIZE
H
FRONT
TO BACK
I
VALVE
G
PRINTED IN U.S.A. 12/17 WP FORM NO. PRO+G RHPDV N Rev. 3
SHIP
WT.
(LBS)
UNIFORM
ENERGY FACTOR
(UEF)NA T. LP NA T. LP NAT. LP
T
INTEGRATED HOME COMFORT
Vent and Combustion Air Inlet System
INTEGRATED HOME COMFORT
MIN. ALLOWED EQUIVALENT VENT
& COMBUSTION AIR-INLET SYSTEM
LENGTHS (EACH PIPE RUN)
MODEL NUMBER
VENT & COMBUSTION
AIR-INLET SYSTEM
DIAMETER
INCHES FEET METERS FEET METERS
FROM SEA LEVEL TO 2,000 FT. (609 M) ABOVE SEA LEVEL
3 7 2.1 50 15.2 90° Elbows
PRO+G50-65N RH62 PDV
AND
PRO+G50-47P RH62 PDV
3 7 2.1 40 12.2 Concentric*
3 7 2.1 40 12.2 Concentric**
4 7 2.1 100 30.5 90° Elbows
4 7 2.1 90 27.4 Concentric*
4 7 2.1 90 27.4 Concentric**
FROM 2,000 FT. (609 M) THROUGH 5,400 FT. (1,646 M) ABOVE SEA LEVEL
3 7 2.1 50 15.2 90° Elbows
PRO+G50-65N RH62 PDV
AND
PRO+G50-47P RH62 PDV
3 7 2.1 40 12.2 Concentric*
3 7 2.1 40 12.2 Concentric**
4 7 2.1 100 30.5 90° Elbows
4 7 2.1 90 27.4 Concentric*
4 7 2.1 90 27.4 Concentric**
FROM 6,000 FT. (1,829 M) ABOVE SEA LEVEL THROUGH 7,800 FT. (2,377 M) ABOVE SEA LEVEL
3 7 2.1 50 15.2 90° Elbows
PRO+G50-65N RH62 PDV
AND
PRO+G50-47P RH62 PDV
3 7 2.1 40 12.2 Concentric*
3 7 2.1 40 12.2 Concentric**
4 7 2.1 100 30.5 90° Elbows
4 7 2.1 90 27.4 Concentric*
4 7 2.1 90 27.4 Concentric**
FROM 7,701 FT. (2,347 M) ABOVE SEA LEVEL THROUGH 10,100 FT. (3,078 M) ABOVE SEA LEVEL
3 7 2.1 25 7.6 90° Elbows
PRO+G50-65N RH62 PDV
AND
PRO+G50-47P RH62 PDV
One 90° elbow is approximately equivalent to 5 feet of pipe. One 45° elbow is approximately equivalent to 2.5 feet of pipe. *Use only Rheem 3 in. (7.6 cm) concentric termination kit number SP20245. **Use only Rheem 4 in. (10.2 cm) concentric termination kit number SP20919.
3 7 2.1 20 6.1 Concentric*
3 7 2.1 20 6.1 Concentric**
4 7 2.1 50 15.2 90° Elbows
4 7 2.1 45 13.7 Concentric*
4 7 2.1 45 13.7 Concentric**
MAX. ALLOWED EQUIVALENT VENT
& COMBUSTION AIR-INLET SYSTEM
LENGTHS (EACH PIPE RUN)
Residential Gas
Water
Professional Classic Plus Power Direct Vent Water Heaters
VENT AND COMBUSTION
AIR-INLET SYSTEM
TERMINATION(S)
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100
Roswell, Georgia 30076 • www.rheem.com
INTEGRATED HOME COMFOR
PRINTED IN U.S.A. 12/17 WP FORM NO. PRO+G RHPDV N Rev. 3
2
Loading...