Revox M 219 User Manual

0 (0)

Re:connect

M 219

Additional room amplifier

Dominating Entertainment.

Revox of Switzerland.

M219 room amplifier

Re:connect

Contents

 

 

 

 

M219 Additional room amplifier

2

 

Safety

 

 

 

3

 

Installation and operation

3

 

Safety measures

4

 

Warranty

 

 

 

4

 

 

 

 

 

 

 

 

 

Front view

5

 

Connection plan

6

 

Detailed description

7

 

[1]

Local IN 1 2 3

7

 

[2]

PRE OUT

7

 

[3]

DIL Setup switches

8

 

 

 

 

(1) IR receiver

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

(2) Pre Out

9

 

 

 

 

(3) Input IN

10-11

 

 

 

 

(4-5) Local inputs

12

 

 

 

 

(6-7-8) Addressing

 

 

12

 

 

 

 

 

 

 

[4]

M219 Link

13

 

[5]

IR Link

13

 

[6]

Input IN

14

 

[7]

Channel Select

14-15

 

[8]

IN Revox MR Bus

15

 

[9]

OUT Revox MR Bus

15

 

[10]

R-L Speakers

16

 

[11]

Fuse

16

 

 

 

[12] AC Power

16

 

 

 

 

 

 

 

 

 

 

M219 cabling plan diagram

17

 

Multiroom Cabling

18

 

Personal M219 settings

18

 

Technical data

19

 

Guarantee

20

 

Delivered items

20

 

1

M219 room amplifier

Re:connect

M219

Additional room amplifier

General

The M219 is a digital Additional Room Amplifier from the newest M Series in the REVOX Multiroom programme. It is used for the reproduction of music in the additional rooms in a Multiroom system and can also supply the listener with current information through an additional display. The M219 receives the signals from a selected source (CD, Tuner, Server ...) in the main room through a multiroom bus cable. Volume, balance, bass and treble settings can be made in individually in each room. Also, up to 3 local sources can be connected and listened to in each additional room. If you want “concealed” operation, various wall-mounted controllers or IR receivers can be connected.

Installation

The M219 should be installed in such a way that the ventilation slots are not covered up and so that there is a gap of at least 5 cm ( ≈ 2 in) between the unit and any walls or furniture.

You should avoid installing it in locations where:

-there is direct sunlight

-it is next to a heat source

-there is poor ventilation

-there is a lot of dust in the atmosphere

-it is unstable

-there is a risk of splashing

-there is high humidity

Furthermore you may not place objects filled with liquids, such as vases, or naked flame sources, such as lighted candles, on the M219.

Stacking several M219s

If you want to stack several M219s on top of each other, we recommend that you use the corresponding installation kit, with the Part no. 1.551.313.00.

M219 Room-Amplifier

M219 Room-Amplifier

M219 Room-Amplifier

2

M219 room amplifier

Re:connect

Safety

Please take note of the information shown on the labels on the rear of the unit. Housings should not be removed, in order to avoid the danger of an electric shock. Maintenance and repairs should only be carried out by qualified personnel.

This symbol warns of “dangerous voltages” within the unit. In the case of contact with the corresponding components, the level of voltage can cause an electric shock.

!

This symbol indicates important advice for operation and maintenance in this documentation.

Installation and operation

Please check the unit and accessories for any signs of transit damage, once you have unpacked it. Please read the operating instructions carefully before starting to use the unit. Keep the documentation somewhere safe for future reference.

If the unit shows any signs of damage or has come into contact with any fluids should not be connected to a power supply.

Only use the power cable supplied. Before connecting the power, the power supply and unit connection values (power voltage, frequency) must be checked. The fuse used in the unit must conform to the factory definitions contained in the “Technical data” section of this manual.

3

M219 room amplifier

Re:connect

Safety measures

Warranty

Operational anomalies

In the case of any unusual noises or smells coming from the unit, remove the power cable immediately. Have the unit checked as soon as possible by your supplier.

Do not open the unit

The unit should not be opened because of the risk of electrocution.

Periods of non-use

If the unit is not going to be used for a longer period of time, the power cable should be unplugged from the socket as a safety precaution.

Foreign objects

Fluids, flammables or other foreign objects should not find their way into any of the unit’s openings as this can result in breakdowns, fire or an electric shock.

Power cable

Always pull the plug out of the socket while holding the plug housing and not the cable.

Device regulations

REVOX offers a warranty in EU/EEA countries on products bought within the EU, in addition to the statutory warranty provided by the retailer. The warranty covers material and labour during the period of the warranty, which is stipulated in the individual EU countries by the REVOX Sales Partners.

In all countries, the terms of warranty from the REVOX reseller is offered in addition to the statutory regulations. You must be able to prove that the product was bought from an approved REVOX Partner when making any warranty claim.

The warranty is invalidated if any inappropriate or unprofessional repairs have been carried out on the unit.

4

M219 room amplifier Re:connect

M219Front view

[A] [B] [C]

M219 Room-Amplifier

[A]IR Sensor

The InfraRed sensor receives signals from the remote control or from any other IR control devices, such as the PDAs for the music server.

Switching the IR sensor off

If required, the IR sensor can be switched off using the SETUP DIL switch [3] on the rear of the

M219.

[B]Status LED

[C]Ventilation slots

The ventilation slots on the front and the top of the M219 must always be left clear of obstructions.

The M219 should be installed in such a way that the ventilation slots are not covered up and so that there is a gap of at least 5cm between the unit and any walls or furniture.

The blue status LED gives information about the current state of the

M219.

 

LED display

 

 

M219 Status

 

 

 

 

 

 

Permanently dark

 

 

M219 standby mode

 

 

Permanently lit

 

 

M219 active

 

 

Rapid flashing

 

 

Breakdown, overload

 

 

Rapid flashing

 

 

Min/max position reached

 

 

 

 

 

(Volume, Bass, Treble, Balance)

 

 

Slow flashing

 

 

IR receive (RC5 or RC6 Codes)

 

 

Single flash

 

 

LOCAL 1 or general change of source

 

 

Double flash

 

 

LOCAL 2

 

 

Triple flash

 

 

LOCAL 3

 

 

 

5

 

Revox M 219 User Manual

M219 room amplifier

 

 

 

 

 

 

 

 

Re:connect

Connection plan

 

 

 

 

 

 

 

 

 

Rear view

 

 

[1]

[2]

[3]

 

 

[4]

[5]

[6]

 

 

 

 

 

 

 

M219

 

 

LOCAL IN

PRE

SETUP

 

LINK

 

OUT

 

 

+ IN -

1 2 3

OUT

 

 

 

 

 

 

+ -

 

 

 

 

 

 

 

 

L

1 2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

1 2

3

4

 

 

 

 

 

 

 

CHANNEL

 

 

IN OUT

+ R -

- L + FUSE AC - POWER

 

SELECT

 

 

 

MR-BUS

SPEAKERS

[7]

[8]

[9]

[10]

[11]

[12]

Short descriptions

[1]Local Cinch inputs L/R

[2]Preamp outputs L/R

[3]DIL setup switches

[4]M219-Link display connector

[5]IR receiver or wall-mounted remote control connections

[6]Switching voltage input

[7]Stereo/ Mono switch

[8]Multiroom Bus input

[9]Multiroom Bus output

[10] Speaker connections L/R

[11]Fuse

[12]Power connection

6

Loading...