Revox M 219 User Manual

of
Re:connect
M 219
Additional
room amplifier
Dominating Entertainment. Revox of Switzerland
.
M219 room amplifier
Re:connect
Contents
M219 Additional room amplifier Safety Installation and operation Safety measures Warranty
Front view Connection plan Detailed description
[1] Local IN 1 2 3 [2] PRE OUT [3] DIL Setup switches
(1) IR receiver (2) Pre Out
(3) Input IN (4-5) Local inputs (6-7-8) Addressing
[4] M219 Link [5] IR Link [6] Input IN [7] Channel Select [8] IN Revox MR Bus [9] OUT Revox MR Bus [10] R-L Speakers [11] Fuse [12] AC Power
M219 cabling plan diagram Multiroom Cabling Personal M219 settings Technical data Guarantee Delivered items
2 3 3 4 4
5 6 7 7 7 8 8 9
10-11
12 12 13 13 14
14-15
15 15 16 16 16
17 18 18 19 20 20
1
M219 room amplifier
M219
Additional room amplifier
General
The M219 is a digital Additional Room Amplifier from the newest M Series in the programme. It is used for the reproduction of music in the additional rooms in a Multiroom system and can also supply the listener with current information through an additional display. The M219 receives the signals from a selected source (CD, Tuner, Server ...) in the main room through a multiroom bus cable. Volume, balance, bass and treble settings can be made in individually in each room. Also, up to 3 local sources can be connected and listened to in each additional room. If you want “concealed” operation, various wall-mounted controllers or IR receivers can be connected.
Installation
The M219 should be installed in such a way that the ventilation slots are not covered up and so that there is a gap of at least 5 cm ( 2 in) between the unit and any walls or furniture.
REVOX Multiroom
Re:connect
You should avoid installing it in locations where:
- there is direct sunlight
- it is next to a heat source
- there is poor ventilation
- there is a lot of dust in the
atmosphere
- it is unstable
- there is a risk of splashing
- there is high humidity
Furthermore you may not place objects filled with liquids, such as vases, or naked flame sources, such as lighted candles, on the M219.
Stacking several M219s
If you want to stack several M219s on top of each other, we recommend that you use the corresponding installation kit, with the Part no. 1.551.313.00.
Room-AmplifierM219
Room-AmplifierM219
M219
Room-Amplifier
2
M219 room amplifier
Safety
Please take note of the information shown on the labels on the rear of the unit. Housings should not be removed, in order to avoid the danger of an electric shock. Maintenance and repairs should only be carried out by qualified personnel.
This symbol warns of “dangerous voltages” within the unit. In the case of contact with the corresponding components, the level of voltage can cause an electric shock.
!
This symbol indicates important advice for operation and maintenance in this documentation.
Re:connect
Installation and operation
Please check the unit and accessories for any signs of transit damage, once you have unpacked it. Please read the operating instructions carefully before starting to use the unit. Keep the documentation somewhere safe for future reference.
If the unit shows any signs of damage or has come into contact with any fluids should not be connected to a power supply.
Only use the power cable supplied. Before connecting the power, the power supply and unit connection values (power voltage, frequency) must be checked. The fuse used in the unit must conform to the factory definitions contained in the “Technical data” section of this manual.
3
M219 room amplifier
Safety measures
Operational anomalies
In the case of any unusual noises or smells coming from the unit, remove the power cable immediately. Have the unit checked as soon as possible by your supplier.
Do not open the unit
The unit should not be opened because of the risk of electrocution.
Periods of non-use
If the unit is not going to be used for a longer period of time, the power cable should be unplugged from the socket as a safety precaution.
Foreign objects
Fluids, flammables or other foreign objects should not find their way into any of the unit’s openings as this can result in breakdowns, fire or an electric shock.
Power cable
Always pull the plug out of the socket while holding the plug housing and not the cable.
Re:connect
Warranty
Device regulations
REVOX offers a warranty in
EU/EEA countries on products bought within the EU, in addition to the statutory warranty provided by the retailer. The warranty covers material and labour during the period of the warranty, which is stipulated in the individual EU countries by the Partners.
In all countries, the terms of warranty from the reseller is offered in addition to the statutory regulations. You must be able to prove that the product was bought from an approved making any warranty claim.
The warranty is invalidated if any inappropriate or unprofessional repairs have been carried out on the unit.
REVOX Sales
REVOX
REVOX Partner when
4
M219 room amplifier
Re:connect
M219- Front view
[A] [B] [C]
[A] IR Sensor
The InfraRed sensor receives signals from the remote control or from any other IR control devices, such as the PDAs for the music server.
Switching the IR sensor off
If required, the IR sensor can be switched off using the SETUP DIL switch [3] on the rear of the
M219.
[B] Status LED
The blue status LED gives information about the current state of the
M219.
LED display M219 Status
Permanently dark M219 standby mode Permanently lit M219 active Rapid flashing Breakdown, overload Rapid flashing Min/max position reached
(Volume, Bass, Treble, Balance) Slow flashing IR receive (RC5 or RC6 Codes) Single flash LOCAL 1 or general change of source Double flash LOCAL 2 Triple flash LOCAL 3
M219
Room-Amplifier
[C] Ventilation slots
The ventilation slots on the front and the top of the M219 must always be left clear of obstructions.
The M219 should be installed in such a way that the ventilation slots are not covered up and so that there is a gap of at least 5cm between the unit and any walls or furniture.
5
M219 room amplifier
Connection plan
Short descriptions
[1] Local Cinch inputs L/R
[2] Preamp outputs L/R
[3] DIL setup switches
[4] M219-Link display connector
[5] IR receiver or wall-mounted
remote control connections
[6] Switching voltage input
[1] [2] [3] [4] [5] [6]
12
L
R
LOCAL IN
PRE OUT
3
1432 5678
1432
CHANNEL
SELECT
[7] [8] [9] [10] [11] [12]
Rear view
SETUP
IN
MR-BUS SPEAKERS
Re:connect
M219 LINK
OUT
[7]
[8] Multiroom Bus input
[9] Multiroom Bus output
[10] Speaker connections L/R
[11] Fuse
[12] Power connection
OUT
--
IN
+
+
+ R - - L +
Stereo/ Mono switch
FUSE AC - POWER
6
M219 room amplifier
Detailed descriptions
[1] LOCAL IN 1 2 3
Re:connect
[2] PRE OUT
Local Cinch inputs L/R
The M219 has 3 local line inputs for a CD player, video recorder or TV, for example, which are located directly in the room where the M219 is. The local audio inputs are activated by the Local key on the (wall­mounted) remote control. You can scroll through a loop of the local inputs by repeatedly pressing the Local key:
(Local 1
(Local 2) (Local 3)
The number of active inputs that are actually used can be set through Setup DIL switches 4 &
5. This saves you unnecessary scrolling through non-active inputs. If, for example, only inputs 1 and 2 are used, you can set the switches so that you only have to scroll through Inputs 1 & 2. Input 3 is skipped.
Preamp outputs L/R
Using the M219s preamp outputs, additional output devices can be supplied, or the
REVOX digital speakers can be
operated through the REVOX DLC-2. The configuration of this audio output is described in detail on Page 9.
[3] SETUP
DIL Setup switches
The basic settings of the M219 are configured through these DIL setup switches.
1432 5678
Important Configuration can only be carried out through the setup switches when the M219 is disconnected from the power supply. Otherwise, the new settings are not activated.
The function of each individual switch is described on the next page.
7
M219 room amplifier
Re:connect
DIL setup switches
NO Function Factory setting
1
2
3
4
5
6
7
8
M219 IR eye on/off On
Pre-Out: Fixed Volume Off
LOCAL IN 1 Fixed Volume Off
Number of local inputs On
Number of local inputs On
M219 address Off
M219 address Off
M219 address Off
Please note: The switch is in the ON position when it is down
You can enter your own personal DIL switch settings in a table included on the last pages of this manual, providing you with a record for future reference.
M219 infrared receiver
In some cases, e.g. in buildings with glass internal walls, it can be useful to switch the M219 IR receiver off, in order to avoid operational conflicts with other devices.
IR Function
IR - Off
IR - On
DIL switch
1
Off
On
DIL position
1
1
8
M219 room amplifier
2
2
Re:connect
(2) PRE OUT
Two operating modes are possible with the M219’s preamp output:
Floating Volume (Factory setting
This is the standard mode setting. In this case, the PRE OUT level changes parallel to the speaker level. This means that as you increase the volume at the speakers, for example, the PRE OUT level is automatically changed at the same time.
Application: You should select Floating Volume mode if, for example,
and additional output device or an active subwoofer is connected, whose volume should also be controlled by the M219. This means that the M219 speaker output remains active.
Fixed Volume:
In this mode, the volume control and the M219 output devices are deactivated, i.e. the volume cannot be controlled by any wall-mounted or infrared remote control. The speakers connected to the M219 remain silent. Irrespective of whether it is addressed through the multiroom bus or a local input (Local IN 1 2 3), each source has a standard level, the so-called Line Level.
Application: The Fixed Volume mode has been conceived principally
for applications where digital connected to the M219 over a DLC2 interface.
PRE OUT
Floating Volume
Fixed Volume
from serial # 2000):
DIL switch
2
Off
On
REVOX speakers are to be
DIL position
9
M219 room amplifier
Re:connect
(3) Voltage input IN (from serial # 2000)
Using the voltage input IN on the M219, the local audio input LOCAL IN 1 can be activated by the application of 5 – 24 VDC. This means that
as soon as the voltage is present at IN, the M219 switches on automatically and selects the input LOCAL IN 1. When the voltage is removed from input IN, the M219 switches off again automatically, as long as no other source apart from LOCAL IN 1 was addressed.
With DIL switch (3), you can define whether the volume control is handled by the M219 (Floating Volume) or the connected (TV) device (Fixed Volume). With Fixed Volume, the M219’s volume control is deactivated and the audio signal at LOCAL IN 1 is transmitted with a fixed strength. In this way, volume control is carried out with the TV remote control.
The volume control setting set by DIL switch 3 only has an effect on the local audio input LOCAL IN 1. All other sources are unaffected and operate normally.
LOCAL IN 1
Floating Volume
Fixed Volume
DIL switch
3
Off
On
Application: Many devices output a voltage as soon as they are
switched on. If you connect the voltage output of such a device with the IN voltage input on the M219 and the audio output with the local audio input LOCAL IN 1, the M219 will switch on automatically with the other device and transmit the sound.
If your device doesn’t have a voltage output, you can
supply voltage to the input using a sensor-switch multiple socket outlet (Master/Slave socket outlet) and a normal plug-in power supply (5-24 V= / DC). Please refer to the diagram on Page 11.
DIL position
3
3
10
M219 room amplifier
Cabling: Voltage input IN
Audio
Local (audio)-source
OUT
e.g. TV
WITHOUT
switching-voltage output
Audio
Local (audio)-source
OUT
e.g. SAT-receiver
WITH
switching-voltage output
PRE
LOCAL IN
123
L
R
CAUTION
RiSK OF ELECTRIC SHOCK
DO NOT OPEN
SETUP
OUT
1432 5678
ON
1432
ON
CHANNEL
SELECT
M219 LINK
--
IN
+
IN OUT + R - - L +
MR-BUS SPEAKERS
IN
+
115V / T1A L
FUSEAC - POWER
230V / T0,5A L
5-24V
OUT DC
+
Re:connect
Master
-
5-24V
OUT DC
SlaveSlaveSlave
Please note: SCART sockets
Many devices such as SAT receivers, video recorders or DVD players output a switching voltage through the SCART socket as soon as they are switched on. On a standard SCART socket, PIN 8 outputs the positive voltage (+) and PIN 4 or 14 is the earth (-).
L
The principle of Master/Slave socket outlets
With this type of socket outlets, the control device (the TV in the above example) is plugged into the master socket while all other devices are connected through the slave sockets. As long as the master device is not switched on, all slave sockets remain switched off. Once the master device is switched on, all the slave sockets (the plug-in power supply in the above example) are switched on at the same time. In this way, you can “upgrade” any type of device to give it a switching­voltage output.
11
M219 room amplifier
Re:connect
M219 local inputs
See description: [1] LOCAL IN 1 2 3
Number of local
inputs
0
1
2
3
DIL switch
DIL switch 5 DIL position
4
Off Off
Off On
On Off
On On
5
4
5
4
5
4
5
4
M219 addressing
If you want to control each M219 individually, to use the alarm function of the M51 Timer, for example, it is necessary to assign each M219 its own address. The maximum number of M219s is limited to 8 per zone. All M219s must have different addresses within one zone as otherwise there may be communication problems. The revisal of a correct addressing is made in the Setup menu of the
M51, category Multiroom / Version. All attached devices (M219 and/or M217) must be listed in the respective zone.
Address
1
2
3
4
5
6
7
8
DIL switch
6
Off Off Off
Off Off On
Off On Off
Off On On
On Off Off
On Off On
On On Off
On On On
DIL switch
7
DIL switch
8
DIL position
678
678
678
678
678
678
678
678
12
M219 room amplifier
A
[4] M219-Link
M217- Display connection
The external display M217 can be connected to the M219-Link connector, which can give the listener basic information about the current music programme.
Connection is made using a straight through (not crossed), 4-core telephone cable with an RJ11 plug (6P4C-Modular) connected to the M219 LINK socket.
Front view of RJ11 Connector
* Comment A 3-core cable with screening is recommended. In this case, no further cable would be necessary if you added an additional display at a later stage.
VCCGND
B
Re:connect
[5] IR-LINK Connection for IR receiver or wall-mounted remote control
If it is not possible or not required that the M219 is controlled directly with a remote control, a wall-mounted remote controller (e.g. M218) or and external IR eye (MR-204) can be connected to the IR-LINK connector. Connection to the IR receiver or the wall-mounted remote controller is made using a screwable Phoenix plug connector.
REVOX recommends the use of a
3-core, screened cable* (microphone cable), where the screening is used as an earth. This cable may not be longer than 40 meters. Please refer to the label for the correct cabling:
+  Positive feed - VCC IN  IR Signal - Data
- Earth - GND
the maximum number of IR receivers per M219 is 5.
IR commands
The M219 accepts all RC5 or RC6 commands and carries out those that are intended for it. All others are transferred on to the Multiroom central unit.
13
M219 room amplifier
Re:connect
[6] IN Voltage input (from serial # 2000)
Using the voltage input IN on the M219, the local audio input LOCAL IN 1 can be activated by the application of 5 – 24 VDC. This means that as soon as the voltage is present at IN, the M219 switches automatically to LOCAL IN 1, irrespective of which source had been selected previously.
For further information please refer to DIL switch (3) / Page 10.
Please note: The voltage input IN is galvanically isolated from the M219 with a high-resistance (10kΩ) optical coupler. This stops any disturbances from either side having any effect.
[7] CHANNEL SELECT
Stereo/ Mono switch
Using the Channel Select switch, you can adjust the operating mode of the two music (stereo) channels, to the requirements of the room where the M219 is installed. Three operating modes are available:
1) Stereo The left music channel is reproduces through the left speaker connector and the right channel through the right connector.
2) Inverse stereo After installation, it can occur that the left and right speaker connections have been inverted or that the sound picture is not correct for the normal listening position. In this case, a quick solution is offered with the Inverse stereo operating mode, which inverse the assignment of the left and right speaker connectors.
3) Mono If only one speaker is connected to the M219, or if the M219 is controlling two speakers, each in a different room, you should select the Mono operating mode. This means that each speaker receives all the music information.
The configuration of the Channel Select switches is described on the
next page.
14
M219 room amplifier
Re:connect
[7] CHANNEL SELECT
Configuration
Operating
mode
Stereo
Inverse
Stereo
Mono
You can change the switch settings during operation if the volume level is turned down low.
DIL- 1
Switch
DIL- 2
Switch
Left channel Right channel
On Off Off On
Off On On Off
On On On On
[8] IN
REVOX MR-BUS
DIL- 3
Switch
DIL- 4
Switch
[9] OUT
REVOX MR-BUS
DIL
Position
3
14
2
3
14
2
3
14
2
Multiroom Bus input
Connection of the
REVOX
Multiroom Bus cable, which is connected to the Multiroom central unit e.g. M51 MR Module MKII.
Connection is made using a
screened and uncrossed RJ45 cable.
Multiroom Bus output
Connection for a further M219, which is connected with a
REVOX Multiroom Bus cable.
A maximum of 8 M219s can be connected in this way.
Connection is made using a
screened and uncrossed RJ45 cable.
15
M219 room amplifier
!
!
[10] R – L SPEAKERS
Speaker connection
Always use a cable of a sufficient diameter for connecting your speakers to the M219.
REVOX recommends:
up to 15 m: Ø 1.50 mm up to 30 m: Ø 2.50 mm over 30 m: Ø 4.00 mm
We recommend not to use cables longer than 50, due to the unavoidable loss of HiFi reproduction.
Each individual speaker must have an impedance of 4 or higher. You must ensure that all cable strands are within the screwable Phoenix connector and that none of them come into contact with any adjacent connectors or the M219 housing.
You will only be assured of a perfect stage-quality reproduction if you ensure correct polarity when connecting. A wrong polarity will not cause any damage to the speaker or to the M219, but it can result in imprecise and diffused reproduction that is weak in the base ranges.
2
2
2
Re:connect
[11] FUSE
Fuse
Always power the unit down before replacing the fuse.
When replacing the fuse, always one of the same type as shown on the M219 rating label.
Other fuse types with different power, voltage or operational characteristics can endanger your life and damage the unit.
The fuse holder can be removed by pushing it in slightly and then turning it in the direction of the arrow.
[12] AC-POWER
Power connection
Only use the cable supplied. You must also ensure that the power supply used delivers the voltage as shown on the M219 rating label (240V). If required, the M219 can be modified to work with other voltages. This modification should only be carried out by an authorised specialist.
REVOX power
16
M219 room amplifier
Further IR-Module
MR204
IR-Receiver
Re:connect
ReVox IWS65
Loudspeaker
z.B.
AC-Power
115V/ 230V
Further M219
Room-Amplifier
M219
M218
M217
M219 Cabling plan diagram
M218
Wall Display
Wall Display
Keypad
CD SERVER AUX2
TUNER
V
RE OX
CD SERVER AUX2
TUNER
FM Tuner
LOCAL
<>
SWR3
LOCAL
<>
-
+
5-24V
- VOL + OFF
Timer Menu
- VOL + OFF
OUT DC
Switching voltage
M219
IN
+
--
IN
+
LINK
SETUP
PRE
LOCAL IN
OUT
123
FUSE AC - POWER
115V / T1A L
230V / T0,5A L
+ R - - L +
OUT
MR-BUS SPEAKERS
IN
1432
1432 5678
SELECT
CHANNEL
ON
ON
DO NOT OP EN
CAUTION
RiSK OF ELECTR IC SHOCK
L
R
Zone 1
Zone 2
Zone 3
Zone 4
M51/ MR-Module MKII
Multiroom centrak unit
e.g.
DLC-2
ReVox
Ext. Amplifier
e.g. VCR
e.g. TV
Digital Loudspeaker Controller
Local audio sources
e.g. local CD-player
17
M219 room amplifier
Multiroom cabling
Multiroom cabling uses a CAT 7 cable, in accordance with the international network standard
EIA/TIA-568-B.
This EIA/TIA-568-B standard provides for the following assignment:
Re:connect
The CAT 7 cable is characterised by 4 twisted pairs, where each pair has its own screening. There is a complete screening around all four pairs.
Clamp
Colour code
MR-signal
1 2 3 4 5 6 7 8
wh/or or wh/gn bl wh/bl gn wh/bn bn
RX TX L+ R+ R- L- GND
Personal M219 Settings (DIL switches)
Room
e.g. Bedroom
1 2 3 4 5 6 7 8
Off Off Off Off Off Off Off Off
On On On On On On On On
Off Off Off Off Off Off Off Off
On On On On On On On On
Off Off Off Off Off Off Off Off
On On On On On On On On
Off Off Off Off Off Off Off Off
On On On On On On On On
Off Off Off Off Off Off Off Off
On On On On On On On On
Off Off Off Off Off Off Off Off
On On On On On On On On
Off Off Off Off Off Off Off Off
On On On On On On On On
Off Off Off Off Off Off Off Off
On On On On On On On On
X X X X X
Off Off Off Off Off Off Off Off
On On On On On On On On
X X X
DIL setup switches
MR
GND
18
M219 room amplifier
Technical data
Amplifier part:
Music power:
Frequency range:
Damping factor:
Harmonic distortion:
General M219 data:
Power voltage:
Power fuse rating:
Re:connect
2 x 50 Watt at 4 Ohm / 1% THD 2 x 25 Watt at 4 Ohm / RMS
10 Hz - 25 kHz / -3 dB
> 200 at 8 Ohm / 1 kHz
0.03 % at 10 Watt
230 V 115 V
0.5 A time-lag
1 A time-lag
Power consumption:
* at room volume without additional devices
Operating conditions:
Dimensions:
Weight:
Errors and technical modifications excepted.
Description: Version 0.90
Max. 115 Watt Operation: 7 Watt* Standby: 2 Watt
(Humidity rating acc. DIN 40040), “+10°... +40°C” / “+50°…+104°F”
Width: 225 mm (8.86 in) Height: 60 mm (2.36 in) Depth: 160 mm (6.30 in)
2.4 kg (5.3 lb)
19
M219 room amplifier
Guarantee
The guarantee period is 24 months from the date of purchase. Your dealer should be your first contact if you need service. If he can't give you the help you need, send the M219 carriage free and without any accessories to your national Sales Office. Please supply a complete description of the problem and a full return postal address.
Re:connect
Delivered items
M219 Multiroom amplifier Power cable 1 RJ11 plug Operating instructions
M219 Additional room amplifier Operating instructions / Part no.: 10.30.3017
20
Loading...