H8/3257 Series, H8/325 Series FP-64A
User System Interface Cable
(HS3257ECH61H)
for E6000 Emulator
User’s Manual
ADE-xxx-xxx
Rev. 3.0
4/1/03
Renesas Technology Corp.
HS3257ECH61HE
Cautions
1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s
patent, copyright, trademark, or other intellectual property rights for information contained in
this document. Renesas bears no responsibility for problems that may arise with third party’s
rights, including intellectual property rights, in connection with use of the information
contained in this document.
2. Products and product specifications may be subject to change without notice. Confirm that you
have received the latest product standards or specifications before final design, purchase or
use.
3. Renesas makes every attempt to ensure that its products are of high quality and reliability.
However, contact Renesas’s sales office before using the product in an application that
demands especially high quality and reliability or where its failure or malfunction may directly
threaten human life or cause risk of bodily injury, such as aerospace, aeronautics, nuclear
power, combustion control, transportation, traffic, safety equipment or medical equipment for
life support.
4. Design your application so that the product is used within the ranges guaranteed by Renesas
particularly for maximum rating, operating supply voltage range, heat radiation characteristics,
installation conditions and other characteristics. Renesas bears no responsibility for failure or
damage when used beyond the guaranteed ranges. Even within the guaranteed ranges,
consider normally foreseeable failure rates or failure modes in semiconductor devices and
employ systemic measures such as fail-safes, so that the equipment incorporating Renesas
product does not cause bodily injury, fire or other consequential damage due to operation of
the Renesas product.
5. This product is not designed to be radiation resistant.
6. No one is permitted to reproduce or duplicate, in any form, the whole or part of this document
without written approval from Renesas.
7. Contact Renesas’s sales office for any questions regarding this document or Renesas
semiconductor products.
Preface
Thank you for purchasing the E6000 emulator for the Renesas’s original microprocessor H8/300
series.
The HS3257ECH61H is a user system interface cable that connects an H8/300 series E6000
emulator (HS3008EPI60H; hereinafter referred to as the emulator) to the IC socket for a FP-64A
package for the H8/3257 series, H8/325 series MCU on the user system.
i
Contents
Section 1 Configuration.....................................................................................1
Section 2 Connection Procedures......................................................................3
2.1 Connecting User System Interface Cable to Emulator Station.........................................3
2.2 Connecting User System Interface Cable to User System................................................4
2.2.1 Installing IC Socket .............................................................................................4
2.2.2 Soldering IC Socket.............................................................................................5
2.2.3 Inserting Cable Head ...........................................................................................5
2.2.4 Fastening Cable Head..........................................................................................5
2.2.5 Fastening Cable Body..........................................................................................7
2.3 Recommended Dimensions for User System Mount Pad.................................................8
2.4 Dimensions for User System Interface Cable Head..........................................................9
2.5 Resulting Dimensions after Connecting User System Interface Cable .............................10
Section 3 Installing the MCU to the User System.............................................11
Section 4 Verifying Operation...........................................................................13
Section 5 Notice ................................................................................................14
ii
Section 1 Configuration
CAUTION
Use an IC149-064-008-B5 socket (manufactured by
YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64A package
IC socket on the user system.
Figure 1 shows the configuration of the HS3257ECH61H user system interface cable for the
FP-64A package
Screws (M2.0 x 12 mm)
Screws (M2.0 x 8 mm)
and flat washers
Socket cover
IC socket
User system
Figure 1 HS3257ECH61H User System Interface Cable
and flat washers
(For fastening cable
head)
Cable head
1
Table 1 lists the HS3257ECH61H components. Please make sure you have all of these
components when unpacking.
Table 1 HS3257ECH61H Components
No. Component Quantity Remarks
1 Cable body 1 Includes cables
2 Cable head 1
3 IC socket 1 For the FP-64A package
4 Socket cover 1 For installing an FP-64A-packaged MCU
5 Screws (M2.0 x 12 mm) 4 For fastening cable head (with four flat washers)
6 Screws (M2.0 x 8 mm) 4 For installing an FP-64A-packaged MCU (with
7 Documentation 1 User’s manual for HS3257ECH61H (this manual)
four flat washers)
2