Renesas H8-3007, H8-3052, H8-3048, PBL, H8-3067, H8-3062 User Manual
Specifications and Main Features
Frequently Asked Questions
User Manual
REJ10J0616-0400
H8/3048 Group, H8/3052 Group, H8/3062 Group,
H8/3067 Group, H8/3007 Group FP-100B/TFP-100B
User System Interface Cable for E6000 Emulator
Renesas Microcomputer Development Environment System
HS3064BECH61H User’s Manual
HS3064BECH61HE
H8 Family / H8/300H Series
Rev.4.00
Revision Date: Aug. 20, 2008
Notes regarding these materials
1. This document is provided for reference purposes only so that Renesas customers may select the appropriate
Renesas products for their use. Renesas neither makes warranties or representations with respect to the
accuracy or completeness of the information contained in this document nor grants any license to any
intellectual property rights or any other rights of Renesas or any third party with respect to the information in
this document.
2. Renesas shall have no liability for damages or infringement of any intellectual property or other rights arising
out of the use of any information in this document, including, but not limited to, product data, diagrams, charts,
programs, algorithms, and application circuit examples.
3. You should not use the products or the technology described in this document for the purpose of military
applications such as the development of weapons of mass destruction or for the purpose of any other military
use. When exporting the products or technology described herein, you should follow the applicable export
control laws and regulations, and procedures required by such laws and regulations.
4. All information included in this document such as product data, diagrams, charts, programs, algorithms, and
application circuit examples, is current as of the date this document is issued. Such information, however, is
subject to change without any prior notice. Before purchasing or using any Renesas products listed in this
document, please confirm the latest product information with a Renesas sales office. Also, please pay regular
and careful attention to additional and different information to be disclosed by Renesas such as that disclosed
through our website. (http://www.renesas.com )
5. Renesas has used reasonable care in compiling the information included in this document, but Renesas
assumes no liability whatsoever for any damages incurred as a result of errors or omissions in the information
included in this document.
6. When using or otherwise relying on the information in this document, you should evaluate the information in
light of the total system before deciding about the applicability of such information to the intended application.
Renesas makes no representations, warranties or guaranties regarding the suitability of its products for any
particular application and specifically disclaims any liability arising out of the application and use of the
information in this document or Renesas products.
7. With the exception of products specified by Renesas as suitable for automobile applications, Renesas
products are not designed, manufactured or tested for applications or otherwise in systems the failure or
malfunction of which may cause a direct threat to human life or create a risk of human injury or which require
especially high quality and reliability such as safety systems, or equipment or systems for transportation and
traffic, healthcare, combustion control, aerospace and aeronautics, nuclear power, or undersea communication
transmission. If you are considering the use of our products for such purposes, please contact a Renesas
sales office beforehand. Renesas shall have no liability for damages arising out of the uses set forth above.
8. Notwithstanding the preceding paragraph, you should not use Renesas products for the purposes listed below:
(1) artificial life support devices or systems
(2) surgical implantations
(3) healthcare intervention (e.g., excision, administration of medication, etc.)
(4) any other purposes that pose a direct threat to human life
Renesas shall have no liability for damages arising out of the uses set forth in the above and purchasers who
elect to use Renesas products in any of the foregoing applications shall indemnify and hold harmless Renesas
Technology Corp., its affiliated companies and their officers, directors, and employees against any and all
damages arising out of such applications.
9. You should use the products described herein within the range specified by Renesas, especially with respect
to the maximum rating, operating supply voltage range, movement power voltage range, heat radiation
characteristics, installation and other product characteristics. Renesas shall have no liability for malfunctions or
damages arising out of the use of Renesas products beyond such specified ranges.
10. Although Renesas endeavors to improve the quality and reliability of its products, IC products have specific
characteristics such as the occurrence of failure at a certain rate and malfunctions under certain use
conditions. Please be sure to implement safety measures to guard against the possibility of physical injury, and
injury or damage caused by fire in the event of the failure of a Renesas product, such as safety design for
hardware and software including but not limited to redundancy, fire control and malfunction prevention,
appropriate treatment for aging degradation or any other applicable measures. Among others, since the
evaluation of microcomputer software alone is very difficult, please evaluate the safety of the final products or
system manufactured by you.
11. In case Renesas products listed in this document are detached from the products to which the Renesas
products are attached or affixed, the risk of accident such as swallowing by infants and small children is very
high. You should implement safety measures so that Renesas products may not be easily detached from your
products. Renesas shall have no liability for damages arising out of such detachment.
12. This document may not be reproduced or duplicated, in any form, in whole or in part, without prior written
approval from Renesas.
13. Please contact a Renesas sales office if you have any questions regarding the information contained in this
document, Renesas semiconductor products, or if you have any other inquiries.
IMPORTANT INFORMATION
READ FIRST
• READ this user's manual before using this user system interface cable.
• KEEP the user's manual handy for future reference.
Do not attempt to use the user system interface cable until you fully understand its
mechanism.
User System Interface Cable:
Throughout this document, the term "user system interface cable" shall be defined as the
following product produced only by Renesas Technology Corp. excluding all subsidiary products.
• User system interface cable (HS3064BECH61H)
The user system or a host computer is not included in this definition.
Purpose of the User System Interface Cable:
This user system interface cable is for connecting the emulator station and user system. This
user system interface cable must only be used for the above purpose.
Improvement Policy:
Renesas Technology Corp. (including its subsidiaries, hereafter collectively referred to as
Renesas) pursues a policy of continuing improvement in design, performance, functions, and
safety of the user system interface cable. Renesas reserves the right to change, wholly or partially,
the specifications, design, user's manual, and other documentation at any time without notice.
Target User of the User System Interface Cable:
This user system interface cable should only be used by those who have carefully read and
thoroughly understood the information and restrictions contained in the user's manual. Do not
attempt to use the user system interface cable until you fully understand its mechanism.
It is highly recommended that first-time users be instructed by users that are well versed in the
operation of the user system interface cable.
I
LIMITED WARRANTY
Renesas warrants its user system interface cables to be manufactured
in accordance with published specifications and free from defects in
material and/or workmanship. Renesas will repair or replace any
user system interface cables determined to be defective in material
and/or workmanship. User system interface cables are wearing parts
which Renesas will not repair or replace if damaged and/or worn
through use. The foregoing shall constitute the sole remedy for any
breach of Renesas’ warranty. This warranty extends only to you, the
original Purchaser. It is not transferable to anyone who subsequently
purchases the user system interface cable from you. Renesas is not
liable for any claim made by a third party or made by you for a third
party.
DISCLAIMER
RENESAS MAKES NO WARRANTIES, EITHER EXPRESS OR
IMPLIED, ORAL OR WRITTEN, EXCEPT AS PROVIDED
HEREIN, INCLUDING WITHOUT LIMITATION THEREOF,
WARRANTIES AS TO MARKETABILITY, MERCHANTABILITY,
FITNESS FOR ANY PARTICULAR PURPOSE OR USE, OR
AGAINST INFRINGEMENT OF ANY PATENT. IN NO EVENT
SHALL RENESAS BE LIABLE FOR ANY DIRECT, INCIDENTAL
OR CONSEQUENTIAL DAMAGES OF ANY NATURE, OR
LOSSES OR EXPENSES RESULTING FROM ANY DEFECTIVE
USER SYSTEM INTERFACE CABLE, THE USE OF ANY USER
SYSTEM INTERFACE CABLE, OR ITS DOCUMENTATION,
EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
EXCEPT AS EXPRESSLY STATED OTHERWISE IN THIS
WARRANTY, THIS USER SYSTEM INTERFACE CABLE IS SOLD
"AS IS ", AND YOU MUST ASSUME ALL RISK FOR THE USE
AND RESULTS OBTAINED FROM THE USER SYSTEM
INTERFACE CABLE.
II
State Law:
Some states do not allow the exclusion or limitation of implied warranties or liability for
incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which may vary from
state to state.
The Warranty is Void in the Following Cases:
Renesas shall have no liability or legal responsibility for any problems caused by misuse,
abuse, misapplication, neglect, improper handling, installation, repair or modifications of the user
system interface cable without Renesas’ prior written consent or any problems caused by the user
system.
All Rights Reserved:
This user's manual and user system interface cable are copyrighted and all rights are reserved
by Renesas. No part of this user's manual, all or part, may be reproduced or duplicated in any
form, in hard-copy or machine-readable form, by any means available without Renesas’ prior
written consent.
Other Important Things to Keep in Mind:
1. Circuitry and other examples described herein are meant merely to indicate the characteristics
and performance of Renesas’ semiconductor products. Renesas assumes no responsibility for
any intellectual property claims or other problems that may result from applications based on
the examples described herein.
2. No license is granted by implication or otherwise under any patents or other rights of any third
party or Renesas.
Figures:
Some figures in this user's manual may show items different from your actual system.
Limited Anticipation of Danger:
Renesas cannot anticipate every possible circumstance that might involve a potential hazard.
The warnings in this user's manual and on the user system interface cable are therefore not all
inclusive. Therefore, you must use the user system interface cable safely at your own risk.
III
SAFETY PAGE
READ FIRST
• READ this user's manual before using this user system interface cable.
• KEEP the user's manual handy for future reference.
Do not attempt to use the user system interface cable until you fully understand its
mechanism.
DEFINITION OF SIGNAL WORDS
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER
avoided, will result in death or serious injury.
WARNING
avoided, could result in death or serious injury.
CAUTION
avoided, may result in minor or moderate injury.
CAUTION
potentially hazardous situation which, if not avoided, may result in property damage.
DANGER indicates an imminently hazardous situation which, if not
WARNING indicates a potentially hazardous situation which, if not
CAUTION indicates a potentially hazardous situation which, if not
CAUTION used without the safety alert symbol indicates a
NOTE emphasizes essential information.
IV
WARNING
Observe the precautions listed below. Failure to do so
will result in a FIRE HAZARD and will damage the user
system and the emulator product or will result in
PERSONAL INJURY. The USER PROGRAM will be
LOST.
1. Do not repair or remodel the emulator product by
yourself for electric shock prevention and quality
assurance.
2. Always switch OFF the E6000 emulator and user system
before connecting or disconnecting any CABLES or
PARTS.
3. Always before connecting any CABLES, make sure that
pin 1 on both sides are correctly aligned.
V
VI
Loading...
+ 22 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.