Remington RM193B User Manual

ELECTRIC BLOWER/VAC
®
OWNER’S MANUAL
MODELS: RM191BV, RM193BVT
IMPORTANT: Read and understand this manual before assembling or operating this appliance. Improper use of this appliance can cause severe injury or death. Keep this manual for future reference.
PART NO. 769-05180 P00 (06/09)
REMINGTON ELECTRIC BLOWER/VAC | iII
table of contents
1 Important Safety Information 1
2 Product Identication 3
3 Blower/Vac Assembly 4
4 Blower/Vac Operation 7
Assembling Blower . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Converting from Blower to Vacuum . . . . . . . . . . . . . . . . . . . . 5
Extension Cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Operating the Blower/Vac . . . . . . . . . . . . . . . . . . . . . . . . 8
5 Blower/Vac Maintenance 11
Cleaning and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . 11
Servicing of Double-Insulated Appliances . . . . . . . . . . . . . . . . . 11
6 Troubleshooting 12
7 Replacement Parts 13
8 Warranty Information 14
iv |
DO NOT RETURN THIS UNIT TO THE RETAILER. PROOF OF PURCHASE WILL BE REQUIRED FOR WARRANTY SERVICE.
THIS PRODUCT IS COVERED BY ONE OR MORE U.S. PATENTS. OTHER PATENTS PENDING. For assistance regarding the assembly, controls, operation or maintenance of the unit, please call the Customer Support Department.
Additional information about the unit can be found on our website. For service, please call the Customer Support Department to obtain a list of authorized service dealers near you. Service on this unit, both
within and after the warranty period, should only be performed by an authorized and approved service dealer. When servicing, use only identical replacement parts.
Before beginning, locate the unit’s model plate, which lists the model and serial numbers of your unit. Refer to the sample plate below and copy the information for future reference.
Copy the serial number here:
Copy the model and parent part numbers here:
DO NOT RETURN THIS PRODUCT
Please call the Customer Support Department
or visit our website for assistance:
or
SAVE THESE INSTRUCTIONS
All information, illustrations and specifications in this manual are based on the latest product information available at the time of printing. We reserve the right to make changes at any time without notice.
Copyright© 2009 MTD SOUTHWEST INC, All Rights Reserved.
SERVICE INFORMATION
U.S.
1-866-206-2707
Canada
1-877-696-5533
www.remingtonpowertools.com
welcome
ank you for purchasing this Remington brand Electric Blower/Vac. We are proud to offer this quality product to assist you in keeping your property neat and well­groomed.
is owner’s manual provides complete instructions for safely assembling, operating, and maintaining your Blower/Vac. Read and save these instructions. Refer to this manual each time before using your Blower/Vac.
REMINGTON ELECTRIC BLOWER/VAC | 1
1 important safety information
SAFETY WARNINGS
When using an electric appliance, basic precautions should always be followed, including the following:
WARNING: When using blow­er/vac, follow all basic safety precautions to reduce the risk of re, electric shock, and personal injury.
WARNING: This product con­tains chemicals known to the State of California to cause cancer or birth defects, or other reproductive harm.
WARNING: To Reduce The Risk of Electric Shock – Do not use vacuum on wet surfaces. Do not expose to rain. Store indoors.
BEFORE OPERATING BLOWER/VAC
READ ALL INSTRUCTIONS BEFORE OPERATING THIS BLOWER/VAC.
1. Avoid Dangerous Environments
• This blower/vac is intended for indoor or outdoor use. Do not op­erate blower/vac in rain or in damp or wet locations.
• Do not handle electric plug or blower/vac with wet hands.
• Do not use to vacuum any liquids or wet surfaces. Especially, do not use to vacuum flammable or combus­tible liquids, such as gasoline, or in areas where they may be present.
• Do not vacuum anything that is burning or smoking, such as ciga­rettes, matches, or hot ashes.
• Do not operate blower/vac if it is damaged or not securely and fully assembled.
2. Do not allow blower/vac to be used as a toy. Pay close attention when using blower/vac near children.
3. Do not use blower/vac for any job except that for which it is intended. Use only as described in this manual. Use only attachments included with this blower/vac.
4. Do not use vacuum without dust bag and/or filters in place.
5. Always wear eye protection that meets or exceeds the requirements of ANSI Z87.1.
6. Wear long pants and shoes when operating this blower/vac.
7.
Provide Ground Fault Circuit In­terrupter (GFCI) protection on the circuit or outlet to be used for blower/vac. You may use receptacles with built-in GFCI protection for this safety measure.
WHILE OPERATING BLOWER/VAC
1. Stay alert. Watch what you are doing. Use common sense.
2.
Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
3. Never operate this blower/vac with defective guards or shields, or without safety devices in place.
4. Disconnect from power supply before clearing any blockage.
5. Do not abuse power cord. Never pull or carry blower/vac by power cord. Never yank cord to disconnect from receptacle. To unplug, grasp plug, not the cord. Do not close a door on the cord. Keep power cord from heat, oil, and sharp edges.
6. Use extra care when using blower/vac on stairs.
7. Do not put any object into openings. Do not use with any opening blocked. Keep free of dust, lint, hair, and any­thing that may reduce air flow.
8. Disconnect blower/vac properly. Turn off all controls before disconnecting blower/vac from power supply.
9. e impeller rotates for a few seconds after turning blower/vac off. The rotating impeller can cut or injure fingers. Do not remove the bottom inlet cover while the motor is running or when the blower/vac is plugged into a power outlet.
10.
Do not leave blower/vac when plugged in. Unplug unit from outlet when not in use and before servicing.
2 | Chapter 1: Important Safety Information
MAINTENANCE AND STORAGE OF BLOWER/VAC
1. Maintain blower/vac with care.
• Do not use with damaged cord or plug.
• If blower/vac is not working prop­erly, has been dropped, damaged, left outdoors, or dropped into wa­ter, have it repaired by a qualified service center.
• Keep handles dry, clean, and f from oil and grease.
2. Check damaged parts.
• If a part is damaged, carefully check the damaged part before using the blower/vac. Make sure the part will operate properly and perform its intended function.
• Check for alignment of moving parts, binding of moving parts, breakage of
parts, mounting, and any other con­dition that may affect its operation.
• A guard or other part that is dam­ed should be properly repaired
ag or replaced by a qualified service center unless indicated elsewhere in this manual.
3. Store idle blower/vac indoors. When not in use, store the blower/vac and extension cord indoors in a dry loca-
ree
tion. Store blower/vac above the reach of children or in a locked area out of the reach of children.
4. This appliance is provided with double insulation. Use only identical replacement parts. See instructions for servicing of double-insulated ap­pliances on page 11.
is manual is your guide to safe and proper operation of the blower/vac.
SAVE THESE
INSTRUCTIONS.
REMINGTON ELECTRIC BLOWER/VAC | 3
2 product identication
A. Blower/Vac Housing B. On/O Switch C. Blower Tube D. Bottom Inlet Cover E. Vacuum Bag Adapter F. Vacuum Bag G. Vacuum Tube Adapter H. Upper Vacuum Tube I. Lower Vacuum Tube J. Extension Cord Retainer K. Inlet Plug L. Draw Latch
G
L
E
F
B
H
I
K
Figure 2-1: Remington brand electric blower/vac
Specications
RM191BV RM193BVT
Input
Max. Blower Velocity
Max. Blower Air Output
Vacuum Bag Capacity
Net Weight
120V, 12A
200 mph
350 ft3/min.
1.6 ft3 / 45 L
9 lbs. (4.1 Kg)
C
L
A
D
J
120V, 12A
200 mph
350 ft3/min.
1.6 ft3 / 45 L
9 lbs. (4.1 Kg)
4 |
3 blower/vac assembly
Assembling Blower
WARNING: To Reduce The Risk of Personal Injury or Electric Shock – Disconnect from power source before assembling or changing attachments.
Follow the steps below to assemble the blower. IMPORTANT: e blower will not run unless the bottom inlet cover is locked into place.
1. Slide the blower tube onto outlet on front of blower/vac housing (see Fig­ure 3-1). Securely connect the draw latch to the blower tube (see Figure 3-2).
2. Position front of bottom inlet cover over motor housing hook (see Figure 3-3).
3. Pivot bottom inlet cover to bottom of blower/vac housing. Slightly press locking lever on bottom inlet cover to allow cover to lock into place (see Figures 3-4 and 3-5).
1
Figure 3-1: Sliding blower tube into place
4
Figure 3-4: Pivoting bottom inlet cover to blower/vac housing
Figure 3-2: Connect draw latch to blower tube
3
Figure 3-3: Attaching bottom inlet cover to motor housing hook
2
Figure 3-5: Pressing locking lever
REMINGTON ELECTRIC BLOWER/VAC | 5
Converting from Blower to Vacuum
WARNING: To Reduce The Risk of Personal Injury or Electric Shock – Disconnect from power source before assembling or changing attachments.
Follow the steps below to convert from blower to vacuum. IMPORTANT: The vacuum will not run unless the vacuum tube assembly is locked into place.
1. Press locking lever on bottom inlet cover and remove bottom inlet cover from blower/vac. Remove blower tube from blower/vac.
2. Slide vacuum tube adapter onto outlet on front of blower/vac housing (see Figure 3-6). Securely connect the draw latch to the vacuum bag adapter (see Figure 3-7).
3. Connect the lower and upper vacuum tubes together (see Figure 3-8). Align the ridge on the bottom tube with the channel on the top tube. Press together until you hear a “snap”.
Figure 3-6: Sliding vacuum tube adapter into place
Figure 3-7: Connect draw latch to vacuum bag adapter
1
Figure 3-8: Conntecting lower and upper vacuum tube together
6 |
Chapter 3: Blower/Vac Assembly
Converting from Blower to Vacuum, continued
4. Connect the tubes to the vacuum tube adapter (see Figure 3-9). Align the tab on the top tube with the notch on the vacuum tube adapter. Press together until you hear a “snap”.
5. Position front of vacuum tube adapter assembly over motor housing hook (see Figure 3-10).
6. Pivot vacuum tube adapter assembly to bottom of blower/vac housing. Slightly press locking lever on vacu­um tube adapter to allow adapter to lock into place (see Figures 3-11 and 3-12).
Notch
Tab
Figure 3-9: Connecting vacuum tubes to vacuum tube adapter
2
5
Figure 3-11: Pivoting vacuum tube adapter to blower/vac housing
4
Figure 3-10: Attaching vacuum tube adapter to motor housing hook
3
Figure 3-12: Pressing locking lever
REMINGTON ELECTRIC BLOWER/VAC | 7
4 blower/vac operation
IMPORTANT: is blower/vac is for house­hold use only.
WARNING: Read and under­stand this owner’s manual before operating blower/vac. Make cer­tain you read and understand all Safety Warnings on pages 1 and 2 of this manual. Improper use of this blower/vac can result in severe injury or death from re, electric shock, or body contact with moving parts.
WARNING: To reduce the risk of electric shock, use only with an extension cord intended for outdoor use, such as SW-A, SOW-A, STW-A, STOW-A, SJW-A, SJOW-A, SJTW-A, or SJTOW-A.
Extension Cords
Make sure your extension cord is in good condition. Inspect extension cords periodi­cally and replace if damaged. When using an extension cord, be sure to use one heavy enough to carry the current your blower/vac will draw. An undersized extension cord will cause a drop in line voltage resulting in loss of power and overheating.
e table below shows the correct size exten­sion cord to use depending on cord length and nameplate ampere rating. If in doubt, use the next larger gauge cord. e smaller the gauge number, the larger the cord. To reduce the risk of disconnection of blower/vac from the extension cord during operation, use the cord hitch described in this manual.
Cord Length AWG Cord Size
25 feet
50 feet
100 feet
150 feet
16 AWG
16 AWG
14 AWG
12 AWG
To reduce the risk of electric shock, this blower/vac has a polarized plug (one blade is wider than the other) and will require the use of a polarized extension cord. e blower/vac’s plug will fit into a polarized extension cord only one way. If the plug does not fit fully into the extension cord, reverse the plug. If the plug still does not fit, obtain a correct polarized extension cord. A polarized extension cord will require the use of a polarized wall outlet. is plug will fit into the polarized wall outlet only one way. If the plug does not fit fully into the wall outlet, reverse the plug. If the plug still does not fit, contact a qualified electrician to install the proper wall outlet. Do not change the blower/vac plug, extension cord receptacle, or exten­sion cord plug in any way.
Inspect cord often. Replace if damaged.
Connecting Extension Cord
WARNING: Fully seat the ex­tension cord on the inlet plug of blower/vac. Failure to do so could lead to overheating of blower/ vac. This could cause a re that results in personal injury to you or others.
e blower/vac has a built-in extension cord retainer. is cord hitch prevents ac­cidental disconnection of the power cord during use. e cord hitch is molded into the lower rear of the blower/vac housing.
1. Plug extensio of appliance (see Figure 4-1).
2. Create a loop in the extension cord and insert the loop through the cord slot of the blower/vac housing (see Figure 4-2).
3. Pull the loop tight around the molded cord hitch (see Figure 4-3).
n cord into the inlet plug
Figure 4-1: Plugging extension cord into inlet plug
Figure 4-2: Inserting extension cord loop through cord slot
Figure 4-3: Pull extension cord loop tight around molded cord hitch
8 | Chapter 4: Blower/Vac Operation
Operating the Blower/Vac
e on/off toggle switch has three settings; off, low, and high. e middle switch po­sition, marked “O”, is off. e rear switch position, marked “I”, is low. e forward switch position, marked “II”, is high. See Figure 4-4.
Blower Operation
WARNING: The blower can throw debris, causing injury to those nearby.
• Do not blow nails, bolts, rocks,
or other hard objects.
• Do not operate blower near
bystanders or pets.
• Be careful when blowing de-
bris from stairs, corners, or other tight areas. Objects can be blown back toward operator.
• Wear approved eye protec
long pants, and shoes while operating this blower/vac.
tion,
Figure 4-4: On/O switch positions
Figure 4-6: On/O Switch to LOW position
Properly assemble the blower/vac for blower operation (see page 4, Assembling Blower). Follow the steps below to operate the blower.
1. Hold blower/vac using the handle on housing (see Figure 4-5).
2. When ready to the on/off switch to either the low “I” or high “II” setting (see Figure 4-6).
3. To stop the blower, toggle the on/off switch to the off “O” setting.
start the blower, toggle
Figure 4-5: Holding blower/vac for blower operation
Figure 4-7: Operating blower
REMINGTON ELECTRIC BLOWER/VAC | 9
Vacuum Operation
WARNING: The vacuum can throw debris, causing injury to those nearby.
• Do not operate vacuum without
the vacuum bag attached or with the bag zipper opened.
• Do not vacuum nails, glass,
rocks, wire, staples, or other sharp, pointed, or hard objects. These items could be thrown through the cloth bag.
CAUTION: Vacuum only soft items such as leaves and cut grass. Hard items such as sticks, rocks, and acorns will damage the impeller.
CAUTION: Do not force the vacuum tube into a pile of debris. Do not hold the tube upright and force-feed debris into the tube. These actions may clog and dam­age the impeller. If the vacuum vibrates excessively or makes abnormal noises, turn vacuum o, unplug power cord, and check for clogging. Clear any clogged debris from the blower/vac.
CAUTION: Normal vacuum usage causes the vacuum bag to wear and deteriorate. A worn or deteriorated bag allows vacuum to throw debris through the bag, possibly hitting and injuring the operator. Check vacuum bag fre­quently. If it is worn, deteriorated, or damaged, replace with a genu­ine vacuum bag.
Properly assemble the blower/vac for vacuum operation (see page 5, Converting from Blower to Vacuum). Follow the steps below to operate the vacuum.
1. Hang vacuum b using the attached strap. Hold blow­er/vac using the handles on housing and vacuum tube adapter assembly (see Figure 4-8).
2. When ready to start the vacuum, toggle the on/off switch to either the low “I” or high “II” setting (see Figure 4-4).
3. Move end of vacuum tube over soft debris. Vacuum will pick up debris, chop it up, and deposit it into vacuum bag (see Figure 4-9).
4. To stop the vacuum, toggle the on/off switch to the off “O” setting.
ag from your shoulder
Figure 4-8: Holding blower/vac for vacuum operation
Figure 4-9: Picking up debris with vacuum
10 |
Chapter 4: Blower/Vac Operation
Emptying the Vacuum Bag
1. Turn vacuum off and unplug power cord.
2. Lift and rele bag adapter and remove from blower/ vac housing (see Figure 4-10).
3. Unzip vacuum bag and shake out contents (see Figure 4-11).
4. Zip the vacuum bag closed and reassemble vacuum bag adapter to blower/vac housing. Note: Be sure to securely connect the draw latch to the vacuum bag adapter.
ase draw latch on vacuum
Removing Clogged Debris from the Impeller
1. Turn vacuum off and unplug power cord.
2. Press locking lever on vacuum tube
dapter and remove tube adapter as-
a sembly from blower/vac (see Figures 4-12 and 4-13).
3. Check the impeller for clogged debris and any signs of damage. Carefully remove debris from impellers (see Figure 4-14).
4. Replace vacuum tube adapter assem­bly.
Figure 4-13: Removing vacuum tube adapter
Figure 4-10: Removing bag/adapter assembly
Figure 4-11: Unzipping and emptying bag
Figure 4-12: Pressing locking lever
Figure 4-14: Removing debris from impellers
REMINGTON ELECTRIC BLOWER/VAC | 11
5 blower/vac maintenance
Cleaning and Maintenance
WARNING: Disconnect blower/ vac from power supply before cleaning or servicing. Severe injury or death could occur from re, electrical shock, or rotating impeller.
WARNING: When cleaning blower/vac:
• Do not subme rse in any
liquids
• Do not use products that con-
tain Ammonia, Chlorine, or abrasives
• Do not use chlorinated cleaning
solvents, Carbon Tetrachloride, Kerosene, or Gasoline.
Use a soft cloth dampened with a mild soap and water mixture to wipe blower/vac housing. Do not spray or pour water directly onto blower/vac.
When not in use, store the blower/vac and extension cord indoors in a dry location.
Figure 5-1: Cleaning blower/vac housing
Servicing of Double-Insulated
Appliances
A double-insulated appliance is marked with one or more of the following: e words “DOUBLE INSULATION” or “DOUBLE INSULATED” or the double insulation symbol (square within a square).
In a double-insulated appliance, two sys­tems of insulation are provided instead of grounding. No grounding means is provided on a double-insulated appliance, nor should a means for grounding be added to the appliance. Servicing a double-insu­lated appliance requires extreme care and knowledge of the system, and should be done only by qualified service personnel. Replacement parts for a double-insulated appliance must be identical to the parts they replace.
12 |
6 troubleshooting
WARNING: Unplug blower/vac from power source before servicing. Severe
injury or death could occur from re, electrical shock, or rotating impeller.
Note: For additional help, visit
www.remingtonpowertools.com.
OBSERVED FAULT POSSIBLE CAUSE REMEDY
Motor does not run when you turn on/o switch low or high
Motor runs, but vacuum will not pick up debris
Blower/vac vibrates excessively and/or makes abnormal noises
1. Bottom inlet cover or vacuum tube adapter not locked into place
2. Extension cord connection is loose
1. Clogged vacuum tube or impeller
2. Vacuum bag full
Clogged vacuum tube or impeller Follow steps under Removing Clogged
1. Check inlet cover or vacuum tube adapter for proper installation (see blower/vac assembly, page 4)
2. Check cord connection at electrical outlet and at rear of blower/vac
1. Follow steps under Removing Clogged Debris from the Impeller, page 10
2. Empty vacuum bag (see Emptying
the Vacuum Bag, page 10
Debris from the Impeller, page 10
T
Y a b S c a m
D A
P P B
h
REMINGTON ELECTRIC BLOWER/VAC | 13
7 replacement parts
Replacement Parts
Use the part numbers below to order replacement parts for your blower/vac.
Part
Item Description
1
Blower Tube
2
Bottom Inlet Cover
3
Vacuum Bag with Adapter
4
Upper Vacuum Tube with Adapter
5
Lower Vacuum Tube
Number
731-07378
731-07379
764-04084
731-07380
731-07381
1
3
2
4
5
14 |
The limited warranty set forth below is given by Remington LLC (“Remington”) with respect with new merchandise purchased and used in the United States, its possessions and territories.
Remington warrants this product against defects in material and workmanship for a period of two (2) years commencing on the date of original purchase and will, at its option, repair or replace, free of charge, any part found to be defective in material or workmanship. This limited warranty shall only apply if this product has been operated and maintained in accordance with the Operator’s Manual furnished with the product, and has not been subject to misuse, abuse, commercial use, neglect, accident, improper maintenance, alteration, vandalism, theft, fire, water, or damage because of other peril or natural disaster. Damage resulting from the installation or use of any accessory or attachment not approved by Remington for use with the product(s) covered by this manual will void your warranty as to any resulting damage.
HOW TO OBTAIN SERVICE: Warranty service is available, WITH PROOF OF PURCHASE THROUGH YOUR LOCAL AUTHORIZED SERVICE DEALER. To locate the dealer in your area, please check for a listing in the Yellow Pages or contact the Customer Service Department of Remington by calling 1-866- 206-2707 or writing to P.O. Box 361032, Cleveland, OH 44136 or if in Canada call 1-877-696-5533. No product returned directly to the factory will be accepted unless prior written permission has been extended by the Customer Service Department of Remington.
This limited warranty does not provide coverage in the following cases:
A. Wear items - Bump Knobs, Outer Spools, Cutting Line, Inner Reels, Starter Pulley, Starter Ropes,
Drive Belts, Saw Chains, Guide Bars
B. Remington does not extend any warranty for products sold or exported outside of the United
States of America, its possessions and territories, except those sold through Remington’s authorized channels of export distribution
Remington reserves the right to change or improve the design of any Remington Product without assuming any obligation to modify any product previously manufactured.
No implied warranty, including any implied warranty of merchantability or fitness for a particular purpose, applies after the applicable period of express written warranty above as to the parts as identified. No other express warranty or guaranty, whether written or oral, except as mentioned above, given by any person or entity, including a dealer or retailer, with respect to any product shall bind Remington. During the period of the Warranty, the exclusive remedy is repair or replacement of the product as set forth above. (Some states do not allow limitations on how long an implied
warranty lasts, so the above limitation may not apply to you.)
The provisions as set forth in this Warranty provide the sole and exclusive remedy arising from the sales. Remington shall not be liable for incidental or consequential loss or damages including, without limitation, expenses incurred for substitute or replacement lawn care services, for transportation or for related expenses, or for rental expenses to temporarily replace a warranted product. (Some states do not allow limitations on how long an implied warranty
lasts, so the above limitation may not apply to you.) In no event shall recovery of any kind be greater than the amount of the purchase price of the product
sold. Alteration of the safety features of the product shall void this Warranty. You assume the risk and liability for loss, damage, or injury to you and your property and/or to others and their property arising out of the use or misuse or inability to use the product.
This limited warranty shall not extend to anyone other than the original purchaser, original lessee or the person for whom it was purchased as a gift.
How State Law Relates to this Warranty: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
To locate your nearest service dealer dial 1-866-206-2707 in the United States or 1-877-696-5533 in Canada.
REMINGTON LLC
P.O. Box 361032
Cleveland, OH 44136
MANUFACTURER’S LIMITED WARRANTY FOR:
8 warranty information
Loading...
+ 42 hidden pages