Remington HH-150T-DFV, HH-220T-DFV User's Manual & Operating Instructions

DANGER
DANGER
User’s Manual & Operating Instructions
Model Numbers HH-150T-DFV / HH-220T-DFV
HEATER SHOWN WITHOUT SAFETY GUARD. PLEASE
ATTACH SAFETY GUARD BEFORE USING HEATER.
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
GENERAL HAZARD WARNING: READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL
BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure to comply with the
instructions and warnings provided with this heater. Failure to comply can result in fire or explosion that can cause property loss, bodily injury, or loss of life. Only persons who can follow and understand these instructions should operate or service this heater. If you need heater info; such as an operating manual, labels, etcetera, contact Pinnacle Products International at 800-641-6996.
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES WITHOUT ADEQUATE VENTILATION. INDOOR USE PERMITTED ONLY FOR
THE TEMPORARY HEATING OF BUILDINGS OR STRUCTURES UNDER CONSTRUCTION, ALTERATION OR REPAIR. This is an unvented portable heater that uses air (Oxygen) from within
the area in which it is used. Failure to provide adequate combustion and ventilation air will result in asphyxiation, carbon monoxide poisoning, bodily injury or death. Refer to “Ventilation” on Page 6.
© 2014 Pinnacle Products International, Inc.
668 Stony Hill Road #302 Yardley, PA 19067 USA Toll Free (800)-641-6996
Fax: (215)-891-8461 • Web: www.remingtonheater.com • Email: info@pinnacleint.com
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WARNING
WARNING
WARNING
WARNING
WARNING
WHILE CONNECTED TO A POWER SOURCE
Table Of Contents
Safety Information.............................................1-2
Features and Specications.................................3
Assembly..........................................................4-5
Operation..........................................................6-7
Ventilation.............................................................6
Storage.................................................................8
Wiring Diagram..................................................10
Troubleshooting Guide.......................................11
Exploded View...................................................12
Parts List.......................................................13-14
Warranty.............................................................15
Safety Information
FIRE, BURN, INHALATION AND EXPLOSION HAZARD. Keep combustibles such
as; building materials, paper or cardboard a safe distance away from the heater as recommended by these instructions. Never use the heater in spaces which contain products such as; gasoline, solvents, paint thinners, dust particles, volatile or airborne combustibles or any unknown chemicals. This is an unvented portable heater. It uses air (Oxygen) from the area in which it is used. Adequate combustion and ventilation air must be provided. Refer to “Ventilation” on page 6. Bulk fuel storage should be a minimum of 25 feet from heater.
DO NOT OPERATE THIS HEATER UNTIL YOU HAVE READ AND THOROUGHLY
UNDERSTAND THESE SAFETY AND OPERATING INSTRUCTIONS.
Failure to comply with the precautions and instructions provided with this heater can result in death, serious bodily injury, property loss or damage from the hazards of fire, soot production, explosions, burns, asphyxiation or carbon monoxide poisoning. Only persons who can read and understand these instructions should use or service this heater.
DO NOT START THE HEATER WHEN EXCESS OIL HAS ACCUMULATED.
DO NOT START THE HEATER WHEN THE CHAMBER IS HOT.
CALIFORNIA RESIDENTS: This product contains chemicals, including lead, known
to the State of California to cause birth defects or other reproductive harm.
Wash hands after handling.
MASSACHUSETTS RESIDENTS: Massachusetts state law prohibits the use of this heater in any building which is used in whole or in part for human habitation. Use of this heating device in Massachusetts requires local fire department permit (M.G.L.C. 148, Section 10A).
NEW YORK CITY RESIDENTS: The New York City Fire Code prohibits the storage, handling and use of kerosene fueled heaters for space heating. Any person violating that provision may be punished by a fine up to $10,000 and a term of imprisonment of up to 6 months.
THE INSTALLATION OF THIS HEATER SHALL COMPLY WITH THE REGULATIONS OF THE AUTHORITIES HAVING JURISDICTION.
Look for this icon throughout the manual for helpful tips on how to assemble, use and clean your DFV Heater.
© 2014, Pinnacle Products International, Inc. Dual Fusion Forced Air Heater User’s Manual
1
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WARNING
DANGER
WARNING
WARNING
WARNING
WHILE CONNECTED TO A POWER SOURCE
Safety Information
RISK OF INDOOR AIR POLLUTION!
The products described in this manual are
kerosene direct-red, forced air heaters.
Kerosene forced air heaters are primarily intended for use for temporary heating of buildings under construction, alteration or repair.
Direct-red means that all of the combustion
products of the heater enter the heated space. This appliance is rated at 98% combustion
efciency, but does produce small amounts of
carbon monoxide.
CARBON MONOXIDE POISONING MAY LEAD TO DEATH!
Carbon monoxide is toxic. Humans can tolerate only small amounts of carbon monoxide and so precautions should be taken to provide proper ventilation. Failure to provide proper ventilation in accordance with the instructions in this manual can result in death.
RISK OF ELECTRIC SHOCK!
ALWAYS use only the electrical power (voltage and frequency) specified on the model plate of the heater.
ALWAYS use only three-prong, grounded outlet and extension cord.
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not directly exposed to water spray, rain, dripping water, or wind.
RISK OF BURNS, FIRE AND EXPLOSION!
NEVER use fuels such as gasoline, benzine, paint thinners or other oil compounds in this heater.
NEVER refill the heater’s fuel tank while the heater is operating or still hot. This heater is EXTREMELY HOT while in operation.
NEVER block air inlet (rear) or air outlet (front).
People with breathing problems should consult a physician before using this heater.
Early signs of carbon monoxide poisoning
resemble the u. Symptoms of improper
ventilation / carbon monoxide poisoning are:
Headache • Dizziness • Nausea
Sore Throat
Burning of Nose and Eyes
Dry Mouth
If you experience any of these symptoms: GET FRESH AIR AT ONCE! Have your heater serviced and check for proper ventilation. Some people are more affected by carbon monoxide than others. These include: pregnant women, those with heart or lung problems, anemia or those under the influence of alcohol or at high altitudes.
Not For Indoor Use. Indoor use permitted only for the temporary heating of buildings under construction, alteration or repair! Provide at least a three square foot (2,800 sq cm) opening of outside air for every 100,000 Btu / Hr heater rating. Refer to “Ventilation” on page 6 for further instructions.
NEVER use duct work in front or rear of heater.
NEVER move or handle heater while still hot.
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.
CAUTION! HOT WHILE IN
OPERATION. DO NOT TOUCH. KEEP CHILDREN, ANIMALS, CLOTHING AND COMBUSTIBLES AWAY FROM HEATER.
Keep all combustible materials away from this heater.
Minimum Clearance From Combustibles
HH-150T-DFV HH-220T-DFV
Top 4 ft. 4 ft.
Sides 4 ft. 4 ft.
Front 8 ft. 8 ft.
ALWAYS locate heater on a stable and level surface.
If your heater is equipped with a thermostat, once it is plugged in, it can start at anytime in accordance with the thermostat setting.
© 2014, Pinnacle Products International, Inc. Dual Fusion Forced Air Heater User’s Manual
2
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
Specications
Model # HH-150T-DFV HH-220T-DFV
Rating: Btu/Hr 120,000 / 150,000 170,000 / 220,000 Fuel Consumption: Gal/Hr 0.91 / 1.14 1.29 / 1.67 Fuel Tank Capacity: Gallons 10 13 Pump Pressure: PSI 71 / 111 56 / 93 Volts: AC/Hz 120VAC ~ 60 Hz 120VAC ~ 60 Hz Amps Phase
Specications subject to change without notice.
1.7 1.7
Features
Models: HH-150T-DFV / HH-220T-DFV
Front Safety
Guard
Front Handle
Wheel
Control PanelShell
Rear Guard
Rear Handle
Power Cord
Support Frame
Fuel Gauge
Figure 1
© 2014, Pinnacle Products International, Inc. Dual Fusion Forced Air Heater User’s Manual
Fuel Cap
Fuel Tank
3
Drain Plug
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
Assembly Instructions
Model: HH-150T-DFV / HH-220T-DFV
- Remove the heater and all packaging materials from the shipping carton.
Tip: Be sure to remove the axle from the side of the Styrofoam packaging.
WHILE CONNECTED TO A POWER SOURCE
Tools Needed:
- Phillips Head Screw Driver
- 8 mm open end wrench
- 19 mm open end wrench
Tip: Use a power screwdriver and locking wrench for easier assembly.
What’s In The Box
60 mm Screws (8) 35 mm Screws (2) 8 mm Nuts (10) Tires (2)
Safety Guard (1) Axle Nuts (2)
Axle
Wheel Support Frame
Spacers (2)
Front Handle
Spare Drain Plug (1)
Rear Handle
Missing Parts? Please Call 800-641-6996 For Assistance
© 2014, Pinnacle Products International, Inc. Dual Fusion Forced Air Heater User’s Manual
4
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
Assembly Instructions
Models: HH-150T-DFV / HH-220T-DFV
1. Insert axle through holes in wheel support.
2. Slide then spacer onto axle.
3. Slide wheel onto axle with the air valve facing out and hold in place with the axle nuts. (See Figure 2).
Wheel Support Frame
Tire
Axle
Axle Nut
Spacer
Figure 2
4. Place heater on wheel support frame and line up holes on the fuel tank lip.
5. Attach front handle with (4) long screws (50 mm) and (4) nuts through the second and third hole from the front on both sides of the tank lip and wheel support frame and tighten firmly.
Handle
Safety Guard
Wheel Support Frame
Figure 3
6. Insert (2) short screws (30 mm) through the first hole the front of in the tank lip and tighten firmly. Make certain all (6) screws are secure.
7. Attach rear handle with (4) long screws (50 mm) and (4) nuts through the first and second hole from the rear on both sides of the tank lip and wheel support frame and tighten firmly.
© 2014, Pinnacle Products International, Inc. Dual Fusion Forced Air Heater User’s Manual
5
Loading...