Remington FC1001AU User guide

Page 1
CLEANSING
To register your product go to
www.remington-products.com.au
www.remington.co.nz
FACIAL
BRUSH
MANUAL
PLEASE READ
PRIOR TO USE
2 YEAR WARRANTY
FC1001AU
Page 2
When using electrical appliances, especially when children are present, basic safety precautions should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS DEVICE KEEP THE POWER ADAPTOR AWAY FROM WATER
IMPORTANT SAFETY INSTRUCTIONS
For additional protection, the installation of a residual current device (rcd) having a rated residual operating current not excee ding 30 mA is advisable in the electrical circuit supplying the bathroom. Ask your ins taller for adv ice.
DANGER - As with most electrical appliances, electrical parts are electrically live even when the switch is off. WARNING - TO REDUCE THE RISK OF BURNS, ELECTROCUTION AND FIRE OR INJURY TO PERSONS
• Except when charging, always unplug this appliance from the electrical outlet immediately after using.
• Keep the power adaptor cord away from heated surfaces.
• Unplug this appliance before cleaning it.
• Do not use an extension cord or a voltage converter with this appliance.
• Although this appliance is designed to be used around and with water, do not fully submerge the appliance or any of its att achments in water or any other liquid.
• Switch off this appliance before changing attachments.
• Do not wrap the cord of the power adaptor around the unit.
• Do not use this appliance with damaged or broken att achments, as injur y may occur.
• This appliance is not intended for use by persons (including children) with reduced physical, sensor y or mental capabilities, or lack of experience and knowledge, unless they have been given clo se super vision or instruction concerning use of the appliance by a person responsible for their safet y. This appliance is not a toy. Children should be super vised to ensure they do not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
• Use this appliance only for its intended use as described in this manual. Do not use attachments not recommended by Remington.
• Never operate this appliance if it has a damaged cord or plug, if it is not working correctly, if mains adaptor has been dropped or damaged. If the cord of this power adaptor is damaged the power adaptor must be discarded. Handle cord carefully for long life and avoid jerking, twisting or straining, especially at plug connections. The cord cannot be repaired.
• Do not use on people who are asleep.
• Never drop or insert any object into any opening of this appliance.
• Do not place or store this appliance where it can fall or be pulled into a tub or sink.
• Do not plug or unplug the appliance with wet hands.
• Store the product at a temperature between 15°C and 35°C.
• This appliance is not intended for commercial or salon use.
• For the purposes of recharging the bat tery, only use the detachable supply unit provided with this appliance with t ype PA- 0510U( AUS).
2
Page 3
SUITABLE FOR USE IN BATH OR SHOWER.
CAUTIONS AND TIPS BEFORE USING THIS APPLIANCE
Before you star t using your cleansing brush, be sure to read all the warnings and safety infor­mation to ensure that this product is used correctly and is suitable for you.
• Avoid using on delicate skin around the eyes.
• DO NOT use the cleansing brush on the same area more than twice a day.
• DO NOT use the cleansing brush on areas with open wounds, sunburnt skin, chapped or irritated skin.
• DO NOT use if you suf fer from skin diseases or skin irritations such as severe/active acne or skin infection.
• DO NOT use the Cleansing Brush with cleansers containing harsh chemicals or rough particles.
• If you wish to share this product with other users, for hygiene reasons, ensure you change the brush head. DO NOT share brush heads between multiple users.
• If you experience any pain or discomfort, stop using this product and contact your doctor.
3
Page 4
FC1001AU REVITALISE™ FACIAL CLEANSING BRUSH
LUXURY EDITION
USE AND CARE MANUAL
Thank you for purchasing your new Remington™ RE VITALISE™ Facial Cleansing Brush Luxur y Edition set. This advanced beauty tool uses clever cleansing technology with deep cleansing action to breathe new life into your skin. It gently removes any impurities that are trapped in the pores leaving it feeling healthy, looking beautiful and glowing with radiance.
1
2
8
3
6
7
4
5
KEY PARTS
1. Normal Brush Head
(with green ring)
2. LED Indicator Lights
3. On/Of f and Speed Selection Swit ch
4. Cleansing Brush Handle
5. Charging Stand
6. Extra Sensitive Brush Head
(all white)
9
7. Exfoliating Brush H ead
8. Beauty Bag
9. Beauty headband
10. Illuminated Tweezers
ALSO INCLUDES
11. Protective Caps (not shown)
12. Power Adaptor (not shown)
4
10
Page 5
FC1001AU SPECIFICATIONS
Power System Cordless (rechargeable)
Initial Charge Time 24 Hours
Full Char ge Time 6 Hours
Runtime 30 Minut es of Cor dless Usage Time
Indicators Battery low/charging/full
Vol tage Ty pe Worldwide 100-240V
BEFORE YOU START
PLEASE ENSURE TO READ OVER ALL INSTRUCTIONS BEFORE YOUR FIRST USE.
Please allow some time to familiarize yourself with your new Facial Cleansing Brush. A s with any new product, you may need some time to work out the best regime for you, and once done we are confident that you will be pleased with the results!
CHARGING
• Before using for the first time, fully charge the Cleansing Brush for 24 hour s. Note during this charge ignore the elec tronic indicators as they are in “start-up-cycle”.
• Ensure the appliance is switched off whilst it is charging.
• Always ensure that your hands, cleansing brush and mains adaptor are dry before charging.
• To Charge: Insert the charging adaptor into the charging stand. P lug the adaptor into the wall socket and place the Cleansing Brush on the charging stand.
• The charging indicator lights will glow in a rot ating sequence whist the cleansing brush is charging.
• When the Cleansing Brush is fully charged, all of the charging indicator light’s will remain illuminated.
NOTE: If the bat tery charge is low, all three LED lights will pulse on and off whilst in use.
QUICK CHARGE FUNCTION
The cleansing brush is also equipped with a quick charge function. To utilise this function, charge the Cleansing Brush for 30 minutes. This will provide approximately 4-6 uses.
5
Page 6
ATTACHING THE AT TACHMENTS
Your Cleansing Brush includes 3 attachment heads for all your cleansing needs:
• NORM AL: For ever yday deep cleansing suitable for all skin t ypes.
• EXTR A SENSIT IVE: For extra gentle cleansing of sensitive skin.
• EXF OLI ATING: For the gentle removal of dead skin cells.
TO ATTACH & REMOVE THE BRUSH HE ADS:
• Hold the handpiece with one hand.
• With the other hand, gently pull the attachment head upwards until it comes off.
• To replace the brush head, gently push the attachment down aligning it with the cavity opening until it locks in place. Gently wriggle the attachment head to ensure it is locked in place, if it comes loose gently remove the head and realign it until it is snugly at tached to the handpiece.
REPLACING YOUR ATTACHMENTS
We recommend replacing the brush heads every 3-6 months depending on the usage of the attachment. The replacement brush heads that we have available to purchase are the normal brush head, sensitive brush head and the massaging brush head. Replacement brush heads can be purchased from your local retailer or Remington S ervice Centre. Simply fill out the enclosed accessory order form or alternatively your order can be processed over the phone via the Remington Service Hotline.
6
Page 7
Page 8
IMPORTANT:
For help or to place an order on the phone
call Remington Customer Service:
Australia: 1800 623 118 (toll free)
New Zealand: 0800 736 776 (toll free)
Normal Brush Head
Sensitive Brush Head
Massaging Brush Head
NZD
Price each
$
$
$
$19.95 NZDSPW-FC4AU
$
Sub Total
$ 7.50
$
TOTAL
handling
Postage &
AUD
Price each
Part No. Qty Amount
Article
$14.95 AUD
$14.95 AUD $19.95 NZDSPW-FC2AU
SPW-FC1AU $14.95 AUD $19.95 NZD
NEW ZEALAND RESIDENTS:
Spectrum Brands New Zealand Pty Ltd
AUSTRALIAN RESIDENTS:
Spectrum Brands Australia Pty Ltd
Pricing in effect at time of publication, inclusive of GST. Subject to change without notice.
Remington is a registered trade mark of
Spectrum Brands, Inc. or one of
Postage & handling $7.50 standard for Australia & New Zealand.
its subsidiaries.
PO BOX 9817
Newmarket, Auckland, 1149
NEW ZEALAND
Locked Bag 3004
Braeside,VIC 3195
AUSTRALIA
© 2016 Spectrum Brands, Inc.
Rev 05/16
Page 9
HOW TO USE
• Select the brush head to suit your skin type and cleansing need. G ently push the brush head onto the cleansing brush handle.
• Moisten the brush bristles by running under water.
NOTE: DO NOT use the cleaning brush whilst completely dry as this can cause skin irritation.
• Dampen your skin with water and apply cleanser onto your skin. Alternatively, apply your cleanser directly onto the brush.
• Place the cleansing brush directly onto your skin.
• Switch on using the On/Of f button.
• Select the speed:
The cleansing brush will automatically start on speed 1 Press the button again for speed 2 Press the button again twice for speed 3
TIP: When changing the brush heads, test each head on dif ferent speeds to identify which is most comfortable for you. Gently glide the brush over the sk in in circular motions avoiding the delicate eye area. When you feel a pause, move onto the next area.
NOTE: The facial brush will run on a one minute timer, after one minute the device will turn off indicating that you have completed your recommended daily cleansing. To continue to use the cleansing brush for longer than one minute simply press the On/Off button again to enter a new one minute cycle.
• If you wish to end the cleansing cycle early press the On / Off button as per below:
When using speed 1, press On/Of f but ton 3 times When using speed 2, press On/Off button twice When using speed 3, press On/Off button once
• When not in use, store the brush attachments with the protective caps on.
• Ensure the bristles are dry before attaching the protective cap.
TIP: For storage without fraying the brush bristles turn the handpiece on to speed 1 and slowly lower the protective cap onto the head until all brush bristles are neatly inside the protective cap, then switch off the unit.
NOTE: Try to avoid applying too much pressure with the brush when directly on the skin. If this happens the brush will automatically stop its cycle and switch off. This is perfectly normal and helps to ensure a comfortable treatment. The cleansing brush can be restarted by pressing the ON switch.
9
Page 10
CLEANING AND MAINTENANCE
• To ensure long las ting per formance of your cleansing brush, clean t he brush head and the handle regularly.
• Ensure the cleansing brush is switched of f before cleaning.
• DO NOT at tempt to clean any part of this product in a dishwasher.
• DO NOT submerge the brush handpiece or charging stand in water.
• Brush Head: Rinse the brush head and bristles after each use, remove exces s cleanser from the bristles by massaging it with your fingers under running water.
• Handpiece: To clean the handle, wipe with a damp cloth.
• Charging stand: Wipe with a damp cloth and wipe with a dry cloth to remove moisture.
CAUTION: Ensure all part s are dry before connecting the charger into a wall socket.
BATTERY REMOVAL
• The battery must be removed from the cleansing brush before it is scrapped.
• The appliance must be disconnected from the supply mains when removing the battery.
To remove the rechargeable batter y:
• Run the cleansing brush until the motor stops.
• Remove brush head.
• Remove the t wo screws at the base of the handle.
• Using a small screwdriver, pry the top cap off the handle.
• Pry the battery from the internal assembly.
• Dispose of the bat tery s afely.
10
Page 11
Spectrum Brands Australia Pty Lt d and Spectrum Brands New Zealand Limited
WARRANTY AGAINST DEFECTS
In this warranty:
Australian Consumer Law means the Australian consumer law set out in Schedule 2 to the Competition and C onsumer A ct 2010;
CGA means the New Zealand Consumer Guarantees Act 1993;
Goods means the product or equipment which was accompanied by this warranty and purchased
in Australia or New Zealand, as the case may be;
Manufacturer, We or us means:
1. for Goods purchased in Australia, Spectrum Brands Australia Pty Ltd
ACN, 007 070 573; or
2. for Goods purchased in New Zealand, Spectrum Brands New Zealand Limited,as the case may be, contact details as set out at the end of this warranty;
Supplier means the authorised distributor or retailer of the Goods that sold you the Goods in Australia or in New Zealand; and
You means you, the original end-user purchaser of the Goods.
1. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law, or the CGA. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of accept able quality and the f ailure does not amount to a major failure.
2. The benefits provided by this Warranty are in addition to all other rights and remedies in respect of the Goods which the consumer has under either the Australian Consumer Law or the CGA. The original purchaser of the Goods is provided with the following Warranty subject to the Warranty C onditions:
3. We warrant the Goods for all parts defective in workmanship or materials for the period of two (2) years from the date of purchase (Warranty Period). If the Goods prove defective within the Warranty Period by reason of improper workmanship or material, we may, at our own discretion, repair or replace the Goods without charge.
Warranty Conditions
4. The Goods must be used in accordance with the manufacturer’s instructions. This Warranty does not apply should the defect in or failure of the Goods be attribut able to misuse, abuse, accident or non-observance of manufacturer’s instructions on the par t of the user. As far as the law permits, the manufacturer does not accept liabilit y for any direct or consequential loss, damage or other expense caused by or arising out of any failure to use the Goods in accordance with the manufacturer’s instructions.
5. Exhaustible components (such as shaver heads, cutters and foils) of the Goods are included under this Warrant y only where there is a defect in workmanship or materials used.
6. The warranty granted under clause 3 is limited to repair or replacement only.
7. Any parts of the Goods replaced during repairs or any product replaced remain the property of the manufacturer. In the event of the Goods being replaced during the Warranty Period, the warranty on the replacement Goods will expire on the same date as for the Warranty Period on the original Goods which are replaced.
11
Page 12
8. In order to claim under the warranty granted under clause 3 you must:
(a) Retain this warranty with your receipt /proof of purchase; and (b) Return the Goods to us at the relevant address below or to the Supplier by prepaid freight
within the Warranty Period accompanied with (i) the legible and unmodified original proof of purchase, which clearly indicates the name and addres s of the
Supplier, the date and place of purchase, the product name or other product serial number and (ii) this warrant y.
9. This warranty is immediately void if:
(a) Any serial number or appliance plate is removed or defaced; (b) The Go ods have been serviced or otherwise repaired by a person not authorised to do so by us or where non approved replaced parts are used.
10. The Goods are designed for domestic use only. A limited 90-day Warranty applies to any
industrial or commercial use of the Goods. The Goods must be connected to the electrical voltage requirements as specified in the ratings label located on the G oods.
11. This warr anty does not cover the cost of claiming under the warrant y or transport of the
Goods to and from the Supplier or us.
12. This warr anty is only valid and enforceable in Australia against Spectrum Brands
Australia Pt y Ltd and in New Zealand against Spectrum Brands New Zealand Limited.
Contact us or the Supplier for further details.
Spectrum Brands Australia Pty Ltd
Locked Bag 300 4 Braeside, VIC 3195 AUSTRALIA Customer service in Australia: 180 0 623 118 E-mail: consumer.enquiry@remington-products.com.au Website: www.remington-products.com.au
Spectrum Brands New Zealand Limited
PO Box 9817 Newmarket, Auckland 1149 NEW ZEALAND Customer service in New Zealand: 0800 736 776 E-mail: info@remington.co.nz Website: www.remington.co.nz
REMINGTON SERVICE HOTLINE
Aust ralia 1800 623 118 (toll free)New Zealand 08 00 736 776 (toll free)
™ Trademark of Spectrum Brands, Inc. or one of its subsidiaries Made in China to the Specifications of Spectrum Brands, Inc. © 2016 Spectrum Brands, Inc.
Rev. 05/16 Part No. T22-0004292
12
Loading...