Reliable 6000IS, 6000CJ, 6000CD User Manual

0 (0)

6000 SERIES

PROFESSIONAL STEAM PRODUCTS

PRODUITS À VAPEUR PROFESSIONNELS

PRODUCTOS PROFESIONALES DE VAPOR

INSTRUCTION MANUAL

GUIDE D’UTILISATION MANUAL DE INSTRUCCIONES

ENGLISH

01

FRANÇAIS

17

ESPAÑOL

33

THE 6000IS

PROFESSIONAL STEAM PRODUCTS INSTRUCTION MANUAL

ENGLISH

01

RELIABLE. RIGHT THERE WITH YOU.

At Reliable, we do what we love, and take pride in doing it right. You want what’s best for the people, places and things that matter in your life – from where you live to what you wear. So do we. From the start, we approach every product with a craftsman’s attention to detail and passion for making it right. Quality, functionality, design and customer service play an equally important part in delivering what’s right for you. With its stainless steel construction, and professional grade components; the 6000 Series will allow you to obtain the benefits of professional pressing or cleaning in a compact and convenient format.

For your safety and to fully enjoy the advantages of this product, please take a few minutes to read all the important safeguards and care instructions. Keep this manual handy and review the product warranty for your reference.

02

IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE

READ ALL INSTRUCTIONS BEFORE USE

When using your Reliable steam station, basic safety precautions should always be followed. Please read the following instructions carefully as they provide important information concerning how to install, use and care for this product.

1.To protect against the risk of electric shock, do not immerse the appliance in water.

2.Do not allow the cord to touch hot surfaces.

3.Always allow the appliance to cool for at least thirty minutes before storing.

4.Always put the appliance in a secure place on a table or counter when using.

5.Do not move the appliance without unplugging it first.

6.Always disconnect the appliance from the outlet before filling with or removing water. Be careful to avoid spilling water on the appliance when filling.

7.Use tap water or 50/50 tap/distilled water in the appliance. Do not use perfumed or products containing alcohol in the appliance.

8.Always disconnect the appliance when not in use.

9.Do not use the appliance if the cord is damaged. Return the appliance or have the cord repaired by the manufacturer, or their service agent.

10.Do not operate the appliance if it has been dropped or damaged. Do not disassemble the appliance. Incorrect reassembly can cause a risk of electric shock. Send it to an authorized service center for repair.

11.Do not operate another high wattage appliance on the same circuit.

12.This appliance must be grounded. Do not alter the plug or attempt to remove this feature.

13.Be careful. Burns can occur from touching hot metal parts or steam.

14.This appliance is not intended for use by young children.

15.While using the appliance, never unscrew or remove the cap (5) while the boiler is under pressure.

16.Before removing the cap, make sure there’s no more steam in the steam chamber by shutting the boiler switch (2) to the off position, and pressing the steam iron button (11) to release all of the remaining steam.

17.To ensure your safety, the safety cap (5) and all other components must be replaced with original parts only.

03

FEATURES

Low water light indicator

Auto shut-off thermostat protection

Regular tap water or 50/50 tap/distilled water

Up to 65 p.s.i operating pressure

Ceramic terminal block

Dual switch pressure control

12-gauge heavy-duty wiring

Up to 8 hours of steam

IRONING

Your new ironing station provides clean, professional results every time

The professional iron soleplate is made from durable, and fast heating aluminum

Stainless steel outer shell construction for long life

Adjustable thermostat allows for accurate temperature settings

Cork handle iron is comfortable and stays cool

STEAM CLEANING

Adjustable steam nozzle with foot pedal (6000CJ)

Steam gun (6000CD)

IMPORTANT: When you want to dispose of the appliance, NEVER throw it in the garbage. Instead, go to your closest recycling station or waste collection centre for subsequent treatment. In this way, you will be contributing to looking after the environment.

04

TECHNICAL DATA

Working voltage: 120V

Nominal capacity of the tank: 4.5 Liters – 1.25 U.S. Gallon Boiler power: 1 heating element 1200W

Power consumption: 16.7 amps (6000IS/120V), 10 amps (6000CJ, 6000CD) Service pressure: 3.5 Bar/4 Bar

Maximum pressure: 4.5 Bar

HOW TO ASSEMBLE AND USE

1.Remove the steam station from its packing and make sure all packing has been removed (including the protective bags). Put the station on a flat and solid surface.

2.Your boiler is supplied with a safety cap on the blow-down valve (left side of tank), as well as a plastic hose and fitting to secure the hose. Please remove the safety cap and install the hose and fitting. This will allow you to follow the proper cleaning procedure (ref. to flush the boiler tank). If there is a problem with the blow-down valve (leaking) you can use the safety cap to prevent water from leaking until you have the valve replaced.

3.A) 6000IS/2100IR: It is recommended to put the iron on the iron pad, (supplied) as the pad will withstand the temperature of the iron. B) 6000CJ: Screw the nozzle into the steam fitting and plug in the 4-pin receptacle for the electronic foot pedal. C) 6000CD: Connect the steam gun or steam brush the same way using the quick disconnect for the steam hose.

4.Insert the two-piece wand (mod. 6000IS) or one-piece wand (mod. 6000CD) into the flange on top of the boiler, tighten with the side screw and attach the spring on the hose (mod. 6000IS) to the coil end of the wand. Note: mod. 6000CJ is not supplied with a wand.

5.Before beginning any operation, make sure that the exhaust valve (9) is closed and the drain hose is installed (ref. step #2).

6.Unscrew the safety cap (5). Fill the boiler with water to the maximum as marked on the water level stick. Use the funnel supplied, making sure you do not overfill the tank.

7.Insert the plug into the electrical outlet; switch on the boiler (2) and steam buttons (1). When the two button lights come on, the steam device and boiler are working.

8.For the 6000IS iron system, turn the iron plate’s temperature regulating knob (12) to the desired temperature.

05

9.Wait approximately 20 minutes for the boiler to reach maximum pressure. Once it reaches 60 psi, the unit is now ready to operate.

10.NOTE: When you call for steam for the first time (after having turned the boiler on) you might notice a fast decrease in pressure. This is normal for the first time.

11.The steam station is ready for use.

12.Push the steam button or the foot pedal for steam.

13.This steam product is equipped with a low water warning light (5) and the thermostat reset button (14, 11 or 13). During operation, if the light comes on, it indicates that the unit requires more water to operate. If this occurs, please follow these steps.

Press the steam iron button or foot pedal to ensure there is no more steam in the boiler.

Slowly open the pressure cap (1) and refill to the required level with warm water.

Replace the cap, tighten and press the thermostat reset button (14, 11 or 13), wait for it to build up pressure again.

IMPORTANT

When you are finished using the boiler for the day, unscrew the fill cap one-turn on the unit to release the steam/air from the tank. This will eliminate the vacuum that may cause damage to the pressure gauge.

For a longer life and better machine performance we suggest that you flush out the boiler tank once a week. Flushing the tank will help slow the sediment/mineral buildup that may occur.

TO FLUSH THE BOILER TANK

(Be careful as the water will be very hot as it comes out of the tank):

1.Release the excess steam still inside the boiler at the end of use (see item #13 above).

2.Turn off the steam switch power switch and unplug the boiler unit.

3.Carefully open the filler plug cap.

4.Make sure the clear drain tubing has been installed on to the blow-down valve (drawing reference #9) situated on the lower right side of the tank, and the tubing is draining into something that can hold hot water.

5.Open the blow down valve. Drain the remaining water from the boiler tank.

6.Close the valve.

06

WATER INSTRUCTIONS

Use tap water or 50/50 tap/distilled water in the appliance. Do not use perfume or products containing alcohol in the appliance.

DESCRIPTION OF THE 6000IS/2100IR

1.Steam switch

2.Boiler switch

3.Low water red pilot light

4.Pressure gauge

5.Safety cap

6.Male 4-pin plug receptacle

7.Quick connect for steam hose

8.Steam regulation knob

9.Blow down valve

10.Steam iron (2100IR/120V)

11.Iron steam switch

12.Temperature regulation knob (2100IR)

13.Silicone iron pad

14.Thermostat reset button

14

07

08

DESCRIPTION OF THE 6000CJ

1.Steam switch

2.Boiler switch

3.Low water red pilot light

4.Pressure gauge

5.Safety cap

6.Female 4-pin receptacle plug (not shown)

7.Steam regulation knob

8.Adjustable steam nozzle

9.Blow down valve

10.Foot pedal with cord and male plug

11.Thermostat reset button

11

09

10

DESCRIPTION OF THE 6000CD

1.Steam switch

2.Boiler switch

3.Low water red pilot light

4.Pressure gauge

5.Safety cap

6.Male 4-pin receptacle plug

7.Quick connect for steam hose

8.Steam regulation knob

9.Cord support

10.Steam gun switch

11.1700DA Steam gun with hose and steam fitting

12.Blow down valve

13.Thermostat reset button

13

11

Reliable 6000IS, 6000CJ, 6000CD User Manual

1700DA

12

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSES

REMEDY

 

 

 

 

 

The steam from the iron

1.

While filling the tank you

1.

The problem will go on

is too wet.

 

may have poured too much

 

until the excess water is

 

 

water into it.

 

emptied. Keep the steam

 

2.

The iron soleplate is not

 

button pressed until the

 

 

getting hot enough.

 

water in the tank is at the

 

 

 

 

correct level.

 

 

 

2.

Please check that the

 

 

 

 

temperature knob is

 

 

 

 

on the right position, if

 

 

 

 

not, increase the iron

 

 

 

 

temperature.

 

 

 

 

 

Water is coming out from

1.

There might be a leak in the

1.

Contact technical support

the boiler.

 

heating element gasket.

 

as in most cases, the

 

 

 

 

gasket will need to be

 

 

 

 

replaced.

 

 

 

 

 

There is no steam coming out

1.

The steam knob might

1.

Open the steam knob

of the iron, nozzle or gun.

 

be closed.

 

anticlockwise.

 

2.

The iron switch might be off

2.

After the iron switch

 

3.

The foot pedal is not

 

comes on, wait for 4 min-

 

 

plugged in (6000CJ).

 

utes so that the iron plate

 

4.

The boiler switch might

 

gets hot.

 

 

be off.

3.

Plug the 4-pin receptacle

 

5.

If the low water light is on,

 

into the boiler.

 

 

the water in the tank is low

4.

After the boiler switch

 

 

or empty.

 

comes on, wait for 10 min-

 

 

 

 

utes so the boiler produces

 

 

 

 

steam.

 

 

 

5.

Refill the boiler carefully

 

 

 

 

following the instructions.

 

 

 

 

 

The steam is dirty.

1.

When using the iron with a

1.

Remove and rinse the

 

 

ironing shoe, if not cleaned

 

ironing shoe on a regular

 

 

regularly, calcium will form

 

(monthly) basis to avoid

 

 

between the shoe and the

 

scale build-up.

 

 

iron base.

 

 

 

 

 

 

 

Machine shuts off

1.

Machine is low on water.

1.

Press the steam iron but-

automatically

 

 

 

ton or foot pedal to ensure

 

 

 

 

there is no more steam

 

 

 

 

in the boiler.

 

 

 

2.

Slowly open the pressure

 

 

 

 

cap (1) and refill to

 

 

 

 

the required level with

 

 

 

 

warm water.

 

 

 

3.

Replace the cap, tighten

 

 

 

 

and press the thermostat

 

 

 

 

reset button (14, 11 or 13),

 

 

 

 

wait for it to build up

 

 

 

 

pressure again.

 

 

 

 

 

13

RELIABLE CORPORATION LIFETIME

PRODUCT WARRANTY POLICY FOR

PRESSURIZED STEAM BOILER TANKS

Reliable Corporation (“Reliable”) warrants to the original purchaser of the boiler noted above from Reliable (the “Reliable Boiler Tank”) that it will be free from defects in materials and workmanship when utilized for normal use by the original purchaser only. Should the Reliable Boiler Tank need replacement, Reliable will do so at no parts and labor cost to the original purchaser, exclusive of shipping.

Subject to the conditions and limitations set forth below, Reliable will either repair or replace any part of a Reliable Boiler Tank that proves defective by reason of improper workmanship or materials. If the defective Reliable Boiler Tank is no longer available and cannot be repaired effectively or replaced with an identical model, Reliable shall replace the defective Reliable Boiler Tank with a current Reliable Boiler Tank of equal or greater value. Repaired parts or replacement products will be provided by Reliable on an exchange basis, and will be either new or refurbished to be functionally equivalent to new. If Reliable is unable to repair or replace a Reliable Boiler Tank, it will refund the current value of that Reliable Boiler Tank at the time the warranty claim is made.

This limited warranty does not cover any damage to a Reliable Boiler Tank that results from improper installation, accident, abuse, misuse, unreasonable use, natural disaster, insufficient or excessive electrical supply, abnormal mechanical or environmental conditions or any unauthorized disassembly, repair or modification. This limited warranty does not extend to any indirect, consequential or incidental damages that may be suffered by a user from the use of a Reliable Boiler Tank, including without limitation, any liability for third party claims for damage, and is limited to the amount paid by the original purchaser for the Reliable Boiler Tank with respect to which this limited warranty protection applies. This limited warranty does not apply with respect to products that have been altered or which are missing serial numbers or for products not purchased directly from Reliable or a dealer authorized by Reliable to sell the Reliable Boiler Tank.

This limited warranty is the only warranty that applies to the Reliable Boiler Tank, supersedes any and all terms that may be contained in any other document or purchase order and may not be altered or amended except expressly in writing by Reliable.

To obtain a repair or replacement under the terms of this warranty, please contact our customer service group at 1 800 268 1649 or at support@reliablecorporation.com. You will be required to submit an original receipt via fax or e-mail. The receipt must reflect that you are the original purchaser, the product was bought directly from Reliable or from an authorized Reliable dealer and that the warranty claim is being made in compliance with the terms set out in this document or any subsequent document issued by Reliable in connection with this policy. You will be issued a return authorization number (RA#) and asked to ship the defective product together with proof of purchase and RA#, prepaid insured to the following address: Reliable Corporation, 5–100 Wingold Ave, Toronto, ON M6B 4K7.

Freight collect shipments will be refused. The risk of loss or damage in transit will be borne by the customer. Once Reliable receives the defective product, it will initiate the repair or replacement process.

14

Loading...
+ 39 hidden pages