WARNING:
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer to
this manual. For assistance or additional information consult
an authorized installer, service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapours and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by an authorized
installer, service agency or the gas supplier.
918-788
Tested by:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
10/21/09
TO THE NEW OWNER
®
Congratulations! You are the owner of a state-of-the-art Gas Insert by Regency
.
The U32 Sunrise Gas Insert has been designed to provide you with all the warmth and charm of a fi replace,
at the fl ick of a switch. The U32S-NG5 and U32S-LP5 have been approved by Warnock Hersey/Intertek for
both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort
and security for many trouble free years to follow.
Please take a moment now to acquaint yourself with these instructions and the many features of your
Regency® Fireplace.
INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
This FPI product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: CAN/
CGA-2.17-M91, and ANSI Z21.88b-2007/CSA 2.33b-2007.
This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the
Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for
Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard
in Canada. See section "Manufactured Mobile Home Additional Requirements" for additional requirements.
This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of
local codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the
U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.
This FPI Mobile/Manufactured Home Listed appliance comes
factory equipped with a means to secure the unit.
This FPI Mobile/Manufactured Home listed appliance comes
equipped with a dedicated #8 ground lug to which an 18 gauge
copper wire from the steel chassis ground must be attached.
2U32S-5 FPI Direct Vent Gas Insert
TABLE OF CONTENTS
SAFETY LABEL
Serial No. Decal.............................................................4
REQUIREMENTS
MA Code - CO Detector.................................................5
Faceplate and Door Frame..........................................35
WARRANTY
The Warranty: Limited Lifetime ...................................39
3U32S-5 FPI Direct Vent Gas Insert
SAFETY LABEL
This is a copy of the label that accompanies each U32S-5 Gas Insert.
We have printed a copy of the contents here for your review. The safety
label is located on a plate inside the base of the unit visible when the
bottom louver is opened.
NOTE: Regency®units are constantly being improved. Check the
label on the unit and if there is a difference, the label on the unit is
the correct one.
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with
battery back up in the same room where the gas appliance is installed.
4U32S-5 FPI Direct Vent Gas Insert
REQUIREMENTS
MA Code - CO Detector
(for the State of Massachusetts only)
5.08: Modifications to NFPA-54, Chapter 10
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for
residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than
seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall
be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled
equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is
installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery
operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure
served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of
qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon
monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of
thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon
monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions
shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight
(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The
sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation
unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR
5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by
the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or
structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product
Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the
instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a
Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies
"special venting systems", the following requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and
detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions,
all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of
the installation.
5U32S-5 FPI Direct Vent Gas Insert
UNIT DIMENSIONS
6U32S-5 FPI Direct Vent Gas Insert
INSTALLATION
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The FPI Gas Insert must be installed in
accordance with these instructions. Carefully
read all the instructions in this manual fi rst.
Consult the building authority having jurisdiction
to determine the need for a permit prior to starting
the installation.
NOTE: Failure to follow the instructions could
cause a malfunction of the heater which could
result in death, serious bodily injury, and/or
property damage. Failure to follow these
instructions may also void your fi re insurance
and/or warranty.
FOR YOUR SAFETY
This appliance requires air for proper combustion.
Always provide adequate combustion and
ventilation air. Follow instructions and
information in CAN/CGA B149 (in Canada) or
the National Fuel Gas Code ANSI Z223.1 (in the
USA), regarding requirements for combustion
and ventilation air.
SPECIFICATIONS
At pressures over 1/2 psig, the pipe to the unit
must be disconnected.
Gas Input Capacity:
Natural Gas 24,500 Btu/h
Propane 20,500 Btu/h
Min. Input
Natural Gas 16,500 Btu/h
Propane 17,000 Btu/h
Fuels: Approved for use with both natural gas,
and propane. Approved as is for use at 0' to
4,500' (0-1370m).
Electrical: 120V A.C. system.
Circulation Fan: Variable speed, 110 CFM.
Vent System: 3" co-linear aluminum fl ex.
The effi ciency rating of the appliance is a
product thermal effi ciency rating determined
under continuous operating conditions and
was determined independent of any installed
system.
GAS PRESSURE
TESTING
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut off valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than
1/2 psig. (3.45 kPa).
INSTALLATION INTO A
SOLID FUEL BURNING
FIREPLACE OR
FACTORY BUILT
FIREPLACE
The U32S Gas Insert has been tested and
approved to be vented into any masonry fi replace
or approved solid fuel burning factory built
fi replace that will allow the insert to physically
fi t into the fi rebox. Refer to "Minimum Fireplace
Dimensions" section for minimum fi replace
clearances.
If the factory built fi replace* height is too low for
your Insert, you may remove the smoke baffl e
plate, damper, refractory (fi rebricks), glass
doors, screen rails, screen mesh and log grates
from the factory built fi replace as long as these
items are saved and are reinstalled in the event
that the Insert is removed.
Smoke shelves, shields and baffl es may be
removed if attached by mechanical fasteners.
If any part is removed it must not weaken the
structural integrity of the factory built fi replace.
NOTE: Any alterations made to the listed solid
fuel burning factory built fi replace may void the
listing of the fi replace.
*Check with your local inspector before
commencing with this installation.
Installer must mechanically attach the supplied
label to the inside of the fi rebox of the fi replace
into which the gas fi replace insert is installed.
"WARNING: This fi replace has been converted
for use with a gas fi replace insert only and
cannot be used for burning wood or solid fuels
unless all original parts have been replaced,
and the fi replace re-approved by the authority
having jurisdiction."
BEFORE YOU ST ART
Safe installation and operation of this appliance
requires common sense, however, we are
required by the Canadian Safety Standards
and ANSI Standards to make you aware of
the following:
General Safety Information
1) The appliance installation must conform
with local codes or in the absence of local
codes, with CAN/CGA B149 (in Canada) or
the National Fuel Gas Code ANSI Z223.1 in
the U.S.A. This appliance should be installed
by a qualifi ed gas fi tter technician only.
2) Installation and repair should be done
by a qualifi ed service person.
3) The appliance should be inspected before
use and at least annually by a professional
service person. More frequent cleaning
may be required due to excessive lint from
carpeting, bedding material, animal hair, etc.
It is imperative that control compartments,
burners and circulating air passageways of
the appliance be kept clean.
4) See general construction and assembly
instructions. This appliance may only be
installed in a vented, noncombustible
fi replace.
5) This appliance is Listed for bedroom
installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) Always connect this insert to a vent system
venting to the outside of the building
envelope. Never vent to another room or
inside a building. Make sure that the vent
is properly sized and is of adequate height
to provide the proper draft.
7) Inspect the venting system annually for
blockage and any signs of deterioration.
8) Any glass removed for servicing must be
replaced prior to operating the appliance.
9) To prevent injury, do not allow anyone who
is unfamiliar with the operation to use the
fi replace.
10) Due to high temperatures, the appliance
should be located out of high traffi c areas
and away from furniture and draperies.
Children and adults should be alerted to
the hazards of high surface temperatures,
especially the fi replace glass and gold
trims, and should stay away to avoid burns
or clothing ignition. Young children should
be carefully supervised when they are in
the same room as the appliance. Clothing
or other fl ammable material should not be
placed on or near the appliance.
Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.
7U32S-5 FPI Direct Vent Gas Insert
INSTALLATION
INSTALLATION
CHECKLIST
Before installing vent system ensure that the
damper plate is open and secure to prevent the
damper plate from falling down and crushing
the liner.
The FPI Gas Insert is installed as listed.
1) Check all clearances to combustibles, (Refer
to sections "Minimum Fireplace Dimensions
and Clearances to Combustibles)
2) Make the gas connection. (Refer to section
"Gas Connection")
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1) Ensure that structural members are not cut
or weakened during installation.
2) Ensure proper grounding using the #8
ground lug provided.
3) Appliance must be anchored to the fl oor
with the supplied anchoring methods.
CLEARANCES TO
COMBUSTIBLES
Minimum Clearances to Combustibles
From Unit
Sides A 10" / 255 mm
Ceiling B 47.5" / 1205 mm
Mantel C 13" / 330mm
Max. Mantle Depth G 12" / 305 mm
Min. Alcove Width K 48" / 1220 mm
Max. Alcove Depth L 36" / 915 mm
3) Install the 3" flue liner to the sliding
connector plate. (Refer to section "Flue Liner
Installation.")
4) Slide the unit half way into the fi replace.
5) Pull the vent connector plate through the
tapered brackets and fasten to the front plate.
Refer to section "Flue Liner Installation.")
6) Slide the unit fully into the fi replace.
7) Test gas pressure (Refer to section "Gas
Pipe Pressure Testing"). Check aeration
system (Refer to section "Gas Insert Aeration
System").
8) Install standard and optional features. Refer
to the following sections:
a. LP Conversion Kit
b. Glass Crystals
c. Optional Ceramic Spa Stones
d. Standard Flush Door
e. Contemporary Faceplate & Door Frame
f. Wall Thermostat
g. Remote Control
9)Final check: Before leaving this unit with the
customer, the installer must ensure that the
appliance is fi ring correctly. This includes:
MATERIALS REQUIRED
No electrical power supply is required for the gas
control to operate. A 120 V olt AC power cord is
hooked up to the fan. Plug the 3 wire cord into
a suitable receptacle. Do not cut the ground terminal off under any circumstances. When
connected with 120 volts, the appliance must be
electrically grounded in accordance with local
codes, current version of CSA C22.1 (in Canada)
or in the absence of local codes, with the National
Electrical Code ANSI/NFPA 70-1987.
NOTE: This unit is equipped with a heat
sensor thermodisc which will
prevent the blower from operating
until the unit reaches the correct
temperature.
MINIMUM FIREPLACE
DIMENSIONS
The minimum fi replace clearances & dimensions
for the FPI gas insert are shown in the following
diagrams:
A
B
G
L
A
C
K
a) Clocking the appliance to ensure the
correct fi ring rate.
b) Adjusting the primary air, if required, to
ensure that the fl ame does not carbon.
See "Gas Insert Aeration System"
section.
c) Ensuring that the appliance is venting
correctly.
Max. Lentil
Bar Depth
A
9"22"14"22-1/2"26-1/2"
8U32S-5 FPI Direct Vent Gas Insert
B
C
D
E
HeightBDepthCWidth
(rear)
D
Width
(front)
E
INSTALLATION
12" Mantel
3-1/2"
Mantel
47”
(1194mm)
to ceiling
17"
13"
20“
to floor
2
0
12
6
4
810
2
0
12
6
16
4
14
8
18
10
Side View
Top of
Unit
Faceplate
Top
G
C
L
Gas
Inlet
COMBUSTIBLE MANTEL
CLEARANCES
Due to the extreme heat this fi replace emits,
the mantel clearances are critical.
GAS CONNECTION
GAS CONNECTION WARNING:
Only persons licensed to work
with gas piping may make the
necessary gas connections
to this appliance.
1) If the appliance is to be installed into an
existing chimney system, thoroughly clean
the masonry or factory built fi replace.
2) The appliance is provided with an opening on
the left hand side of the control compartment.
A 3/8" NPT gas supply pipe must be brought
near this inlet hole.
3) Locate the center point where the vent
will pass through the chimney above the
appliance. Move the appliance into the
exact location where it is to be installed.
Ensure that the Insert is level.
Alternate Approved Caps
46dva-VC Vertical Termination Cap
46dva-VCH High Wind Cap
46dva-GK 3" Co-linear Adaptor with fl ashing
In areas of consistently high winds, we
recommend using the Simpson Dura-Vent
System (46dva-GK adapter and 46dva-VCH
high-wind cap).
Note: A non-combustible mantel may be
installed at a lower height if the
framing is made of metal studs
covered with a non-combustible
board.
Mantel can be installed anywhere in shaded area
or higher using the above scale.
Note: Ensure the paint that is used
on the mantel and the facing is
"heat resistant" or the paint may
discolour.
The Air Intake pipe must be attached to the
inlet air collar of the termination cap.
VENTING
THE APPLIANCE MUST NOT BE
CONNECTED TO A
CHIMNEY FLUE SERVING A
SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium fl ex running
the full length of the chimney. The fl ue length
must be a minimum length of 8 ' (2.44m) and
a maximum of 35' (10.7m). See chart below for
minimum distances from roof. Periodically check
that the vent is unrestricted.
Masonry chimneys may take various contours
which the fl exible liner will accommodate.
However, keep the fl exible liner as straight as possible, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet
air collar of the termination cap.
Part # Description
948-305 3" Flex - 35 ft.
946-529 Co-linear DV Vertical
Termination Cap
9U32S-5 FPI Direct Vent Gas Insert
INSTALLATION
FLUE LINER
INSTALLATION
1) Cut the fl ex liner as required.
2) Mark the end of one liner to indicate Inlet.
3) Connect the other end of the above liner to
the inlet side of the termination adaptor, seal
connection with high temperature silicone.
Secure with gear clamp.
4) Connect the 2nd liner to the exhaust side
of the adaptor, seal connection with high
temperature silicone. Secure with gear
clamp.
5) Install fl ashing.
Be careful not to damage thermal insula-
tion when sliding on vent connector plate.
This could cause blockage.
5) The pressure check should be carried out
with the unit burning and the setting should
be within the limits specifi ed on the safety
label.
6) When fi nished reading manometer, turn
off the gas valve, disconnect the hose and
tighten the screw (clockwise) with a 1/8"
fl at screwdriver . Note: Screw should be
snug, but do not over tighten.
GAS INSERT
AERATION SYSTEM
The burner aeration is factory set but may need
adjusting due to either the local gas suppply or
altitude. Open the air shutter for a blue fl ame
or close for a yellow fl ame.
The burner assembly will need to be removed
in order to adjust burner aeration if required.
See steps 1-4 in 'Conversion from NG to LP.
Minimum Air shutter Opening
Glass
Crystals
Natural Gas3/8"1/8"
Propane1/2"3/8"
Ceramic
Stones
6) Insert both liners into chimney, passing
through the damper opening.
7) Install termination cap.
8) Connect the marked end of the liner to
the inlet collar of the vent connector plate
marked with an "I", seal connection with
high temperature silicone. Secure with gear
clamp.
9) Connect the 2nd liner to the exhaust collar
marked with an "E", seal connection with
high temperature silicone. Secure with gear
clamp.
NOTES:
1) Final gas connection should be made after
unit is in place to avoid damage to line when
pushing the unit into position.
2) Mill-pac may be used instead of high
temperature silicone and screws may be
used instead of gear clamps at connections
of liner to inlet and vent collars.
GAS PIPE
PRESSURE TESTING
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shut-off valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig. (3.45
kPa). Disconnect piping from valve at pressures
over 1/2 psig.
The manifold pressure is controlled by a
regulator built into the gas control, and should
be checked at the pressure test point.
Note: To properly check gas pressure, both
inlet and manifold pressures should
be checked using the valve pressure
ports on the valve.
1) Make sure the valve is in the "OFF"
position.
2) Loosen the "IN" and/or "OUT" pressure
tap(s), turning counterclockwise with a 1/8"
wide fl at screwdriver.
3) Attach manometer to "IN" and/or "OUT"
pressure tap(s) using a 5/16" ID hose.
4) Light the pilot and turn the valve to "ON"
position.
CAUTION: Carbon will be produced if air
shutter is closed too much.
Note: Any damage due to carboning
resulting from setting the aeration
controls improperly is NOT covered under
warranty.
Note: Aeration Adjustment should only
be performed by an authorized FPI
Installer at the time of installation
or service.
10U32S-5 FPI Direct Vent Gas Insert
INSTALLATION
CONVERSION KIT # 434-969 FROM NG TO LP
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION!!
NOTE: See page 1 for H25 / H27 conversion instructions and page 4 for P33S-4 conversion instructions.
Each Kit contains one LP
Conversion Kit and one DC
Sparker Kit.
LP Conversion Kit Contains:
Qty. Part # Description
1 904-163 Burner Orifi ce #54
1 918-590 Decal "Converted to
LPG"
1 908-528 Red "LPG" label
1 904-529 5/32" Allen Key
1 910-037 LPG Injector
(Pilot Orifi ce)
1 918-480 Instruction Sheet
DC Sparker Kit Contains:
Qty. Part # Description
1 820-475 Bracket DC Sparker
1 820-476 Bracket DC Sparker
1 904-153 Washer #8 External Star
1 904-330 Nut 8-32 Hex
1 904-438 Plug Nylon 0.750 Hole,
Black (for H25 only)
1 904-531 Bushing Split Plastic
0.500 in.
1 904-543 Screw 8-32 x 3/4 Pan
Head
2 904-553 Screw #8 x 1/2 Type
"B", Black Oxide
1 910-073 Spark Generator
Battery Holder
1 910-074 Spark Generator
Switch C/W Wire
1 910-078 Battery Size AA
Energizer En91
2 910-199 Clip Wire Holder
1 910-903 Wire Fan To Power Cord
Ground 30 in.
904-781 Velcro Hook, Black
904-782 Velcro Hook, Black
1) Turn off the gas supply.
U32S only:
a) Release the two hooks from the
bottom of the glass door.
b) Swing the door out 45 degrees from
the bottom and lift up and out (applies
to both units).
3) Remove the back shield by undoing the
2 screws and lift out (E33S unit only).
Back Shield
4) Remove the burner by undoing the 2
screws as shown below.
Burner screws on E33S
Burner screws on U32S
5) After screws have been removed,
slide the burner to the left, then lift out
carefully (U32S unit only.)
(E33S - lift burner directly out).
U32S burner shown
6) Remove the base cover by lifting up
from the back and maneover out.
2) Remove the glass door.
E33S only:
a) Remove the 2 screws at the bottom
of the glass door.
Base Cover
Burner
11U32S-5 FPI Direct Vent Gas Insert
INSTALLATION
Lift up from the back.
7) Remove burner orifi ce with a 1/2" wrench
and discard.
8) Install the new LP burner orifi ce stamped
#54 and tighten.
9) Remove the pilot shield by removing the
2 screws as shown below.
10) Pull off the pilot cap to expose the pilot
orifi ce.
15) From the valve remove the black protec-
tion cap by hand from the high-low knob
(Fig.1).
Fig. 1
16) Insert the allen key
into the hexagonal
key-way of the
screw (Fig. 2),
rotate it counterclockwise until it is
free and extract it.
Fig.2
17) Check that the screw is clean and if
necessary remove dirt.
Burner Orifi ce - E33S
Burner Orifi ce -U32S
18) Flip the screw (Fig. 3).
11) Unscrew the pilot orifi ce with the
supplied allen key and replace it with
the LP pilot orifi ce and re-install the pilot
cap.
Fig.3
19) Using the allen key as shown in Fig.4,
rotate the screw clockwise until snug, do
not overtighten.
12) Re-install base cover.
13) Re-install burner and back shield.
14) Reinstall pilot cover
LP Aeration Settings - set before
reinstalling burner.
E33S1/4"
U32S Glass Crystals Spa Stones
1/2"3/8"
Fig.4
12U32S-5 FPI Direct Vent Gas Insert