Regency Horizon HZ42ST Installation Manual

Regency Horizon
Installer
: Please complete the details on the back cover
HZ42ST
Owners &
Installation Manual
Gas Fireplace
MODELS: HZ42ST-NG Natural Gas
HZ42ST-LP Propane
WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury or loss of life.
FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.
918-808
Tested by:
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Installer
Homeowner: Please keep these instructions for future reference.
: Please complete the details on the back cover
and leave this manual with the homeowner.
www.regency-fi re.com
FOR YOUR SAFETY What to do if you smell gas: Do not try to light any appliance Do not touch any electrical switch:
do not use any phone in your building.
Immediately call your gas supplier
from a neighbour's phone. Follow the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fi re department.
12/24/09
WARNING
HOT GLASS
CAUSE BURNS
DO NOT TOUCH
UNTIL COOLED
NEVER
TO TOUCH GLASS
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS, AND SHOULD ST AY AWA Y TO AVOID BURNS OR CLOTHING IGNITION.
ALLOW CHILDREN
WILL
GLASS
To the New Owner:
Congratulations! Y ou are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The HZ42 ST has been designed to provide you with all the warmth and charm of a fi replace at the fl ick of a switch. The model HZ42 ST has been approved by Warnock Hersey/Intertek for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow . Please take a moment now to acquaint
yourself with these instructions and the many features of your Regency
MANUFACTURED MOBILE HOME REQUIREMENTS
INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE
This Regency® product has been tested and listed by Warnock Hersey/Intertek as a Direct Vent Wall Furnace to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88a-2007 / CSA 2.33a-2007 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN / CGA 2.17-M91.
This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.
®
Fireplace.
This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFP A 70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.
This appliance comes equipped with a dedicated #8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.
This appliance may only be installed in an aftermarket permanently located, manufactured (U.S.A only) or mobile home, where not prohibited by local codes.
This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
Ensure that structural members are not cut or weakened during installation.
2
HZ42ST Regency HorizonTM Gas Fireplace
TABLE OF CONTENTS
SAFETY LABEL
Copy of Safety Decal .....................................................4
REQUIREMENTS
MA Code - CO Detector.................................................5
DIMENSIONS
Unit Dimensions ............................................................6
INSTALLATION
Important Message ......................................................7
Before You Start ............................................................7
General Safety Information............................................7
Installation Checklist ......................................................8
Locating Your Gas Fireplace .........................................8
Clearances ....................................................................9
Non-Combustible Requirements ...................................9
Mantel Clearances.......................................................10
Mantel Leg Clearances................................................10
Unit Assembly Prior To Installation ..............................11
Standoff Assembly ...............................................1 1
Horizontal vent Defl ector installation ...........................1 1
Nailing Strips ........................................................11
Framing & Finishing.....................................................12
Framing Dimensions....................................................13
Vent Restrictor Position ...............................................14
Exterior Vent Termination Requirements .....................15
4” x 6-5/8” Rigid Pipe Cross Reference Chart .............16
Venting Introduction .....................................................18
Venting Arrangements ................................................18
Allowable Horizontal Terminations for HZ42 ST ..18
Horizontal Terminations ...............................................19
Flex Vent 4" x 6-5/8" ....................................................19
Rigid/Flex Pipe Venting Systems.................................20
Horizontal or Vertical Terminations ..............................20
Horizontal Terminations ...............................................21
Vertical Terminations ...................................................24
Unit Installation with Horizontal Termination ...............27
Unit Installation with Horizontal Termination ...............28
Unit Installation with Vertical Termination ....................29
High Elevation .............................................................30
Gas Line Installation ....................................................30
Pilot Adjustment ...........................................................30
Gas Pipe Pressure Testing ..........................................30
S.I.T. Valve Description ................................................30
Aeration Adjustment ....................................................31
Wiring Diagram ...........................................................31
Optional Accent Lighting Wiring Diagram ...................31
Optional Wall Thermostat ...........................................32
Optional Remote Control .............................................32
GT/GTM Remote Features ..........................................32
Wall Switch ..................................................................32
Optional Refl ective Panel Installation ..........................33
Optional Light Installation ............................................34
Glass Crystals or Optional Ceramic Stones
Installation On Burner ..................................................37
Optional Pebble / Crystal Installation...........................38
Glass Door Installation ................................................39
Faceplate Installation...................................................40
OPERATING INSTRUCTIONS
Operating Instructions .................................................42
First Fire ......................................................................42
Lighting Procedure ......................................................42
Shutdown Procedure ...................................................42
Normal Operating Sounds of Gas Appliances .............42
Copy of Lighting Plate Instructions ..............................43
MAINTENANCE
Maintenance Instructions.............................................44
General Vent Maintenance ..........................................44
Thermopile / Thermocouple .........................................44
Glass Gasket ...............................................................44
Glass Door...................................................................44
Glass Replacement .............................................44
Glass Door Removal ...................................................45
DC Spark Box Battery Replacement ...........................45
DC Spark Box Replacement........................................45
V alve Tray Replacement ..............................................46
PARTS LIST
Main Assembly ............................................................48
Accessories .....................................................................
WARRANTY
The Warranty: Limited Lifetime ...................................51
HZ42ST Regency HorizonTM Gas Fireplace 3
SAFETY LABEL
This is a copy of the label that accompanies each HZ42 ST-NG and HZ42 ST -LP Direct V ent Gas Fireplace. We have printed a copy of the contents here for your review.
NOTE: Regency improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
INSTALLATION
®
units are constantly being
918-809a
COPY OF SAFETY DECAL
350
Duplicate S/N
Serial No./ No de serie
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
FOYER AU GAZ À ÉVACUATION
CANADA and U.S.A.
350
Side Walls
Minimum Clearances to Combustibles /
Degagement Minimum De Materiaux Combustibles
é
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE: Mod le HZ42 ST
A 8” (203mm)
B 22” (559mm)
Ceiling
F
B
D
ééé
é
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
Pression à la tubulure d' chappement basse
Grandeur de l'injecteur
C 13" (330mm)
Min. Mantel Height
Max. Mantel Depth
A
C
Calorifique
Calorifique
é
é
D bit minimum selon
D bit maximum selon
l'altitude
D 13” (330mm)
E 84" (2133mm)
Alcove Width
E
F 36" (914mm)
Alcove Depth
DOOR SEAL: Please
é
ééé
QUIP A L'UISINE POUR GAZ PROPANE ÉÉ
CONCU POUR ETRE POELE: Mod le HZ42 ST
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
properly sealed
check that the door is
é
Pression à la tubulure d' chappement basse
Grandeur de l'injecteur
detailed instructions)
(See Instruction Manual for
Calorifique
Calorifique
é
é
D bit minimum selon
D bit maximum selon
l'altitude
Made in Canada/ Fabrique au Canada
FPI Fireplace Products International Ltd. Delta, BC, Canada
POUR UTILISATION UNIQUEMENTAVECLES PORTESEN VERRE CERTIFIÉESAVECL'APPAREIL
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli­ances individual manual shut-off must be a t-handle type valve.
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.
4
é
VENTED GAS FIREPLACE HEATER /
Listed:
Certified for/Certifi e pour:
CAN/CGA-2.17-M91,ANSI Z21.88a-2007/CSA 2.33a-2007
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Tested to:
WN # 16380
NATURAL GAS: Model HZ42ST-NG
WC/C.E.
WC/C.E.
WC/C.E.
5.0" (1.25 kPa)
3.5" (0.87 kPa)
1.6" (0.40 kPa)
Minimum supply pressure
Manifold pressure high
Manifold pressure low
#40 DMS
Orifice size
17,500 Btu/h (5.13 kW)
Minimum input
26,000 Btu/h (7.62 kW)
Maximum input
0-4500 ft/pi (0-1372 m)
Altitude
WC/C.E.
WC/C.E.
12“ WC (2.98 kpa)
19,500 Btu/h (5.71 kW)
24,500 Btu/h (7.18 kW)
10" (2..49 kPa)
6.4" (1.60 kPa)
#53 DMS
0-4500 ft/pi (0-1372 m)
PROPANE GAS: Model HZ42ST-LP
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliancemust be installed inaccordance with the Standard CAN/CSAZ240 MH,Mobile Housing, inCanada, or with theManufactured HomeConstruction and SafetyStandard, Title24 CFR, Part3280, in
the UnitedStates, orwhen such astandard isnot applicable,ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard orANSIA119.2 ouNFPA501CStandardfor Recreational Vehicles
This applianceis only foruse with the typeof gas indicated on therating plate and maybe installed in anaftermarket, permanently located, manufactured(mobile) home where notprohibited by local codes.See
owner's manualfor details.
Installer l'appareilselon lescodes ou règlementslocaux, ou,en l'absence detels règlements,selonlescodesd'installationANSI Z223.1,National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety
Standard. Si cesnormes ne sont pas pertinentes,utilisez lanormeANSI/NCSBCS A225.1/NFPA501A, Manufactured Home InstallationsStandard, ouANSI A119.2ou NFPA 501CStandard for Recreational
Vehicles.
HZ42ST Regency HorizonTM Gas Fireplace
Cet appareildoit êtreutilize uniquement avec letype de gaz indiquésur la plaque signalétique. Cetappareil peutêtre installé dans unemaison préfabriquée ou mobile (É.-U.seulement) installéeà demeure si
les règlementslocaux lepermettent. Voirla notice del'utilisateur pourplus de renseignements.Cet appareilnepeutpasêtreutilisé avec d'autres gaz sauf si une troussede conversioncertifiée est fournie.
NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.
NOT FOR USE WITH SOLID FUELS. /
This ventedgas fireplaceheater is notfor usewith air filters. Ne pasutiliser defiltre à airavec cefoyer au gazà évacuation.
FOR USEWITH GLASSDOORS CERTIFIED WITHTHE APPLIANCEONLY
REQUIREMENTS
MA Code - CO Detector
(for the State of Massachusetts only)
5.08: Modifications to NFPA-54, Chapter 10
(2) Revise 10.8.3 by adding the following additional requirements:
(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors
a. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
INSTALLATION
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL
OBSTRUCTIONS".
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR
5.08(2)(a)1 through 4.
(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:
1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and
2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:
1. Detailed instructions for the installation of the venting system design or the venting system components; and
2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies "special venting systems", the following requirements shall be satisfied by the manufacturer:
1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and
2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
HZ42ST Regency HorizonTM Gas Fireplace 5
DIMENSIONS
INSTALLATION
48-11/16”
1237mm
41-3/16” 1046mm
UNIT DIMENSIONS
3”
76mm
1-1/2”
38mm
18-7/8”
479mm
30-13/16”
783mm
36”
914mm
12-7/8”
327mm
23-5/8”
600mm
28-5/8” 727mm
21-5/8”
549mm
½”
13mm
1-1/2”
38mm
36-1/2”
927mm
12”
305mm
15”
381mm
48-3/4”
1238mm
6
HZ42ST Regency HorizonTM Gas Fireplace
INSTALLATION
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The HZ42 ST Direct Vent Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual rst. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fi replace is installed in compliance with manufacturers instructions and all applicable codes.
BEFORE YOU ST ART
Safe installation and operation of this appliance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:
INST ALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.
WARNING: F AILURE TO INST ALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE.
CHILDREN AND ADUL TS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPE­CIALL Y THE FIREPLACE GLASS, AND SHOULD ST AY AWA Y TO A VOID BURNS OR CLOTHING IGNITION.
YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.
CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.
GENERAL SAFETY
INFORMATION
1) The appliance installation must conform
with local codes or, in the absence of local codes, with the current Canadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.
2) The appliance when installed, must be elec­trically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/ NFPA 70 or CSA C22.1 Canadian Electrical Code.
3) See general construction and assembly instructions. The appliance and vent should be enclosed.
4) This appliance must be connected to the specifi ed vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is fi tted as per Venting instructions.
5) Inspect the venting system annually for blockage and any signs of deterioration.
6) V enting terminals shall not be recessed into a wall or siding.
7) Any safety glass removed for servicing must be replaced prior to operating the appliance.
8) To prevent injury, do not allow anyone who is unfamiliar with the operation to use the replace.
9) Wear gloves and safety glasses for protection while doing required maintenance.
10) Be aware of electrical wiring locations in walls and ceilings when cutting holes for termina­tion.
11) Under no circumstances should this appliance be modifi ed. Parts that have to be removed for servicing should be replaced prior to operating this appliance.
12) Installation and any repairs to this appliance should be done by an authorized service person. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.
13) Do not slam shut or strike the glass door.
14) Under no circumstances should any solid
fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.
15) The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids).
Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
INSTALLATION
HZ42ST Regency HorizonTM Gas Fireplace 7
INSTALLATION
INSTALLATION
CHECKLIST
1) Locate appliance
a) Room location (Refer to "Locating Your
Gas fi replace" section)
b) Clearances to Combustibles (Refer to
"Clearances" section)
c) Mantle Clearances (Refer to "Mantel
Clearances" section)
d) Framing & Finishing Requirements
INSTALLATION
(Refer to "Framing & Finishing" section)
e) Venting Requirements (Refer to "Venting"
section)
2) Assemble Top and Side Standoffs (Refer to "Unit Assembly Prior to Installation).
3) Slide unit into place.
4) Install vent (Refer to "Venting Arrangement"
sections).
5) Make gas connections (Refer to "Gas Line Installation section).
6) Make electrical connections to receptacle
supplied with unit (recommended).
7) Install 1 AA battery into DC spark box.
8) Test the pilot (Refer to "Pilot Adjustment"
section).
9) Test Gas Pressure (Refer to "Gas Pipe Pres­sure Testing" section).
10) Install standard and optional features. Refer to the following sections:
a) Optional Accent Light Installation b) Glass Crystals/ Optional Ceramic Stones c) Optional Firebox Base Pebbles d) Optional Refl ective Panels e) Faceplate f) Remote Control or Wall Thermostat
11) Wall Mounted ON/OFF Switch:
Use the toggle wall switch supplied with the
manual package. Use of a “decor” switch causes higher resistance which is a problem on gas fi replaces.
12) Final check.
Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring correctly and operation fully explained to
customer.
This includes:
1) Clocking the appliance to ensure the correct
ring rate (rate noted on label 26,000 Btu/h (NG), after burning appliance for 15 minutes.
2) If required, adjusting the primary air to ensure that the fl ame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your replace,
ensure that the clearances are met as outlined in the "Clearances" section.
2) Provide adequate clearances for servicing.
3) The appliance must be installed on a at,
solid, continuous surface (e.g. wood, metal, concrete). This may be the fl oor, or raised up on a platform to enhance its visual impact. If the appliance is going to be installed on carpeting, combustible linoleum tile or other combustible material other than wood ooring, the appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.
4) The Direct Vent Gas Fireplace can be installed as follows:
Model # Position A) HZ42: See Thru B) HZ42: See Thru
5) This appliance is Listed for bedroom installations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.
6) The HZ42 ST Direct Vent Gas Fireplace is approved for alcove installations, which meet the clearances listed on this page.
7) We recommend that you plan your installation on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have a qualifi ed inspector, dealer, or installer review your plans before installation.
36" min.
(914mm)
Glass
4-1/2” min. (114mm)
A
Glass
36" min.
(914mm)
HZ42 ST - SEE THRU
Glass
36"min.
(914mm)
36"min. walkway (914mm)
HZ42 ST - SEE THRU
B
(914mm)
Glass
36"min.
Note: For Exterior Vent Termination Locations see section "Exterior V ent
Termination Locations."
8
HZ42ST Regency HorizonTM Gas Fireplace
CLEARANCES
INSTALLATION
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fi replace and vent system be installed only in accordance with these instructions.
The top, back and sides of the fi replace are defi ned by
Caution Requirements
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fi replace and vent
system be installed only in accordance with these instructions.
Clearance: Dimension Measured From:
A: Mantel Height (min.) 13" (330mm) Top of Fireplace Opening B: Sidewall (on one side) 8" (203mm) Side of Fireplace Opening
C: Ceiling (room and/or alcove)
D: Mantel Depth (max.) 13" (330mm) 22" Above Fireplace Opening
E: Alcove Width 84" (2134mm) Sidewall to Sidewall (Minimum) F: Alcove Depth 36" (914mm) Front to Back Wall (Maximum) G: Finished Floor 25-3/4" (654mm) Top of Fireplace Opening
Note 0" (0mm) No Hearth Required
D
A
22" (559mm) Top of Fireplace Opening
F
B
Fire hazard is an extreme risk
C
WARNING
Flue Clearances to Combustibles
Horizontal - Top 3" Horiztonal - Side 2" Horiztonal - Bottom 2" Vertical 2"
Passing through wall/ floor/ceiling - when restop is used.
1-1/2"
F
B
INSTALLATION
G
E
Installed Close
to Floor
Installed Close
to Ceiling
NON-COMBUSTIBLE REQUIREMENTS
Metal Stud (header)
Metal Stud
on edge
13"
(330mm)
25-3/4”
(654mm)
Non-combustible Material
6-½"
(165mm)
57" (1448mm)
Non-combustible
Material
41-1/8”
21-1/4”
Non-combustible Material
HZ42ST Regency HorizonTM Gas Fireplace 9
on edge
Vent End
9-1/2”
(241mm)
4-3/8”
(111mm)
Non-combustible Material
Metal Stud
on edge
Note:
Non-combustible material
always wider at vent end
38 -3/4" (984mm)
4"
7”
4"
7”
4"
7”
4"
7”
INSTALLATION
Due to the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel
clearances from top of front facing are shown in the diagram on the right.
Note: A non-combustible mantel may be
installed at a lower height if the framing is made of metal studs covered with a non-combustible board.
INSTALLATION
Note: Ensure the paint that is used on the mantel
and the facing is "heat resistant" or the paint may discolour.
MANTEL CLEARANCES
Combustible Material
6
810
6
26
26
20
20
14
14
12
12
810
12" (305mm)
4
4
2
2
0
0
Metal Stud (On Edge)
0
2
12" (305mm)
6
8
4
10
12
14
26
20
MANTEL LEG CLEARANCES
Combustible mantel leg clearances as per diagram:
16.5” (419mm)
13.5” (343mm)
Allowable mantel leg projection
9-1/2” (241mm)
10
10
0
0
To Unit
Base
21-1/2”
22”
25-3/4”
1" (25mm)
1" (25mm)
To p o f
To p o f Fireplace
Fireplace Opening
Opening
Non-combustible
13”
13”
13.5” (343mm)
9-1/2” (241mm)
Facing
Standoff
16.5” (419mm)
1" (25mm)
13”
To p o f Fireplace Opening
21-1/2”
25-3/4”
Allowable mantel leg projection
10
0
To Unit
Base
1.5" (38mm)
10
MANTEL LEG
Allowable mantel leg projection
9-1/2”(241mm)
Non-Combustible
1.5" (38mm)
9-1/2” (241mm)
13.5” (343mm)
16.5” (419mm)
1.5" (38mm)
9-1/2”(241mm)
Non-Combustible
1.5" (38mm)
9-1/2” (241mm)
13.5” (343mm)
16.5” (419mm)
MANTEL LEG
Allowable mantel leg projection
HZ42ST Regency HorizonTM Gas Fireplace
INSTALLATION
UNIT ASSEMBLY
PRIOR TO
INSTALLATION
The Standoffs and Nailing Strips must be correctly positioned and attached to the fi rebox before unit is slid into position.
ST ANDOFF ASSEMBLY
The side, top and rear standoffs are shipped in a fl at position and must be folded into shape and attached.
1) Remove the standoffs from the replace.
2) Take each standoff and bend into the correct shape. Bend up at the
bend lines until the screw holes in the standoff and the pre-punched screw holes on the fi replace side line up.
3) Attach the standoff securely to the side with 2 screws per standoff (on opposite corners).
NAILING STRIPS
The side, top and bottom nailing strips come attached to the unit. There are 3 plates on each side and 2 on the bottom - 8 in total. They can be folded out as required. The bottom nailing strip is secured to the unfi nished oor - if installing the unit directly on the fl oor.
Nailing Strips
Nailing Strips shown folded out.
Standoff
IMPORTANT NOTE
Framing depth measurement is noted with the side & top nailing strips set as far forward on the fi rebox as possible. The nailing strips can be adjusted back up to 1” to allow for varying thicknesses in non-combustible material & wall nishes.
INSTALLATION
HORIZONTAL VENT DEFLECTOR INSTALLATION
Note: This installation is only required for horizontal terminations.
If any rise is used when venting this unit - the defl ector and extender are not required.
1) The defl ector and extender are shipped on top of the fi rebox. Slide the defl ector out from under the nailing strip and lift the extender up off the nailing strip.
Defl ector
Defl ector extender
2) Remove the 3 screws near the vent outlet on the fi rebox - as shown below.
3) Install the defl ector near the vent outlet - secure with the same 3 screws. Ensure fl ange on defl ector is facing downward.
4) Install the extender on top of the defl ector with 2 screws - slide the extender until it touches the outside wall - tighten screws to secure. Extender can be adjusted to max. 15-1/2".
Flange
HZ42ST Regency HorizonTM Gas Fireplace 11
INSTALLATION
FRAMING & FINISHING
1) Frame in the enclosure for the unit with framing material.
IMPORTANT: Vertical studs and the header must be metal.
Note: When constructing the framed opening, please ensure there
is access to install the gas lines when the unit is installed.
2) The unit does not have to be completely enclosed in a chase. You
INSTALLATION
must maintain clearances from the vent to combustible materials: See "Clearances" section. Combustible materials can be laid against the side and back standoffs and the stove base.
3) Non-combustible material (ie. tile, slate, etc) may be brought up to and overlap the unit (top and bottom) ensuring that the maximum thick­ness does not go beyond the 1-1/2" as shown in the diagram below. The faceplate will not be able to be mounted if the fi nished material is beyond 1-1/2".
4) If material such as brick, stone, etc. extends past the faceplate depth, when fi nishing around the faceplate, the minimum opening dimen- sions noted below must be adhered to ensuring for the removal of the faceplate and for the safe operation of this appliance.
Finished
Material
Nailing Strip
Position
1/2" 1"
Note:
Depending on the material used for fi nishing, the nailing strips must be set accordingly so that the fi nished material is always at the 1-1/2" edge of the fl ange.
Nailing Strip 1” Forward
Unit
1" 1/2"
Nailing Strip ½” Forward
Unit
1-1/2" 0" (fl ush)
Nailing Strip Flush w/unit Factory Set
12
Unit
HZ42ST Regency HorizonTM Gas Fireplace
FRAMING DIMENSIONS
HZ42ST Framing Dimensions
INSTALLATION
A * Framing Depth * 15" (381mm)
B Framing Height 36-3/4" (933mm)
C Framing Width 50" (1270mm) Horizontal or Vertical Vent
D Gas Connection Height 4-1/2" (114mm)
E Gas Connection Inset 2-7/8" (73mm)
F Gas Connection Opening Width 4-5/8" (117mm)
G Gas Connection Opening Height 2" (51mm)
* Framing depth measurement is noted with nailing strips (top & sides) set as far forward on the fi rebox
as possible. The nailing strips can be adjusted back up to 1" (on both sides) to allow for varying
thicknesses in non-combustible material and wall fi nishes. **Finished material thickness includes: non combustible material, tile slate, etc. (example framing = 13" - if 1" thick fi nishing material is used on both sides)
All studs
are metal (on edge)
**minus 2x the fi nished material thickness
A
B
INSTALLATION
C
Finished Floor
Note: All studs on top and sides of unit must be on edge.
Note: Gas hookup is on vent side of unit.
HZ42ST Regency HorizonTM Gas Fireplace 13
INSTALLATION
VENT RESTRICTOR POSITION
Vent restriction is required for certain venting installations, see the diagrams in the "Venting Arrangements" section to determine if they are required for your installation.
The Vent Restrictor plate is located on the inside top of the fi rebox. To set the vent restriction as indicated in the venting arrangements diagrams, refer to the following instructions;
1) Remove the glass door.
INSTALLATION
2) Remove the screws that hold the vent restrictor plate in place.
3) Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown.
4) Once the vent restrictor plate is in the required position, secure with screws.
3/4”
SET 3
THIS HOLE SETS THE
VENT RESTRICTOR
AT 3/4”
1-1/4”
SET 2
THIS HOLE SETS THE
VENT RESTRICTOR
AT 1-1/4”
2-1/2”
SET 1
THIS HOLE SETS THE
VENT RESTRICTOR
AT 2-1/2”
3”
SET 0
THIS HOLE SETS THE
VENT RESTRICTOR
AT 3 ”
FACTORY SET
14
HZ42ST Regency HorizonTM Gas Fireplace
INSTALLATION
EXTERIOR VENT TERMINATION REQUIREMENTS
INSTALLATION
1
Minimum Clearance Requirements
A
Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm)
B
Clearance to window or door that may be opened 12"(30cm) 9" (23cm)
C
Clearance to permanently closed window **
D
Vertical clearance to ventilated soffi t located above the terminal within a horizontal distance of 2 feet (61cm) from the center line of the terminal (check with the local code)
E
Clearance to unventilated soffi t 19"(48cm) 19"(48cm)
F
Clearance to outside corner: with AstroCap Termination Cap. 7"(18cm) 7"(18cm)
Clearance to outside corner: with all other approved Termination Caps. 13"(33cm) 13"(33cm)
G
Clearance to inside corner: with AstroCap Termination Cap 7"(18cm) 7"(18cm)
Clearance to inside corner: with all other approved Termination Caps. 13"(33cm) 13"(33cm)
H
Clearance to each side of center line extended above meter/regulator assembly 36"(90cm)
J
Clearance to service regulator vent outlet 36"(90cm) *
K
Clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance 12"(30cm) 9" (23cm)
L
Clearance to a mechanical air supply inlet #3' (91cm) above if within 10' (3m) horizontally. 72"(1.8m) 36"(90cm)
M
Clearance above paved sidewalk or a paved driveway located on public property 84"(2.1m)
N
Clearance under veranda, porch, deck, or balcony 12"(30cm)
1
In accordance with current CSA B149.1, Natural Gas and Propane Installation Code
2
In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the fl oor
Clearance in accordance with local installation codes and the requirements of the gas supplier
*
a
3 feet (91cm) within a height of 15 feet (4.5m) above the meter / regulator assembly
b
3 feet (91cm) above - if within 10 feet (3m) horizontally
Canada
18"(46cm) 18"(46cm)
a
USA
2
*
b
*
*
HZ42ST Regency HorizonTM Gas Fireplace 15
Loading...
+ 37 hidden pages