Regency Greenfire GF55 Installation Manual

GF55 & GFI55
OWNER'S MANUAL
Freestanding and Fireplace
Insert Pellet Stove
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury, property damage, or loss of life. Refer to this manual. For assistance or additional information consult an authorized installer or service agency.
Tested by:
IMPORTANT: SAVE THESE INSTRUCTIONS
GF55-079
FPI FIREPLACE PRODUCTS INTERNATIONAL, LTD. 6988 Venture St., Delta, BC, Canada V4G 1H4
FOR YOUR SAFETY : Do not store or use gasoline or other fl ammable vapours and liquids in the vicinity of this or any other appliance.
Installation and service must be performed by an authorized installer or service agency.
10/26/09
WARNING
HOT GLASS
CAUSE BURNS
DO NOT TOUCH
UNTIL COOLED
NEVER
TO TOUCH GLASS
CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES, ESPECIALLY THE FIREPLACE GLASS, AND SHOULD ST AY AWA Y TO AVOID BURNS OR CLOTHING IGNITION.
ALLOW CHILDREN
WILL
GLASS
TO THE NEW OWNER
Congratulations! You are the owner of a state-of-the-art Pellet Stove.
Thank-you for purchasing a
FPI FIREPLACE PRODUCT.
The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the GREENFIRE DEALER in your area.
Safety Note: If this stove is not properly installed, a house fi re may result. For your safety, follow the installation instructions, contact local building, fi re offi cials, or authority having jurisdiction about restrictions and installation inspection requirements in your area.
The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit.
2
Greenfi re Pellet Stove and Insert Owner's Manual
TABLE OF CONTENTS
SAFETY LABEL
Copy of Serial No. Decal ...............................................4
INSTALLATION
Safety Warnings & Recommendations ..........................5
Important Safety Information .........................................6
Pellet Quality .................................................................6
OPERATING INSTRUCTIONS
Control Board Functions ................................................7
Automatic Safety Features ............................................7
Operating Your Pellet Stove ..........................................8
Manual Mode ............................................................8
High / Low Mode.......................................................8
Auto / Off Mode .........................................................8
Slider / Damper Set-Up .................................................9
Hopper Grate Installation...............................................9
MAINTENANCE
Routine Cleaning & Maintenance ................................10
Opening the Door ...................................................10
Burn Pot & Liner .....................................................10
Door Glass Cleaning ..............................................10
Ash Pan & Door Gaskets ........................................10
Ash Pan ..................................................................11
Heat Exchanger Tubes ...........................................11
Fresh Air Intake ......................................................11
Exhaust Vent ..........................................................11
Blower Mechanisms ...............................................11
All Hinges................................................................11
Exhaust Passages ..................................................12
Post Season Clean-Up ...........................................12
Cleaning Plated Surfaces .......................................12
Firebox Panel .........................................................12
Replacing Door Glass.............................................12
WARRANTY
Warranty ......................................................................13
Exclusions and Limitations ..........................................14
Greenfi re Pellet Stove and Insert Owner's Manual 3
SAFETY LABEL
To P ri me A
uger: Restart the u
nit five (
5) mi
nutes into its startup or b
y
putti
ng a sm
a
ll hand f
ull of pellets into the bur
n
pot.
To Operate
Stove: MANUAL MODE: When a fire has been established the stove settings ar
e adj
ustable. / HIGH/LOW MODE:
(Requi
r
es a thermostat) Whe
n
the ther
mostat calls for heat the stove sett
ings are adjustable. When th
e ther
mostat contacts op
en, the HEAT
LE
VEL and Fans
w
ill dr
op down
to the LOW
setting until the thermostat contacts close agai
n. / AUTO/OFF MODE:
(R
equires a ther
mostat) When th
e ther
mostat contacts cl
ose, the
unit wi
ll light
automatically. Once up to temperatur
e the stove set
t
i
ngs are adjustable. When the ther
mostat contacts op
en, the stove will drop down to the LO
W
settin
gs for
30 minutes.
If within
the
30 min the thermostat contacts close,
the HEAT
LE
VEL will r
e
turn to
p
r
evi
ous
MAN
UAL setting or if the ther
mostat con
tacts rem
ain
open the stove beg
in its
shutdown rou
tine.
To T ur
n Off Stove: M
A
NUAL and HI / LOW mode: Pr
ess the ON
/ OFF button
AUTO /
OFF mode
: Tur
n th
e ther
mostat down or of
f
The unit can be installed on a hard,
stable non-combustibl
e surface.
L'unité peut être
i
nstal
lée
sur un dur,
la surf
ace non-combustible stable.
Cert
ifie
d f
o
r
use
in Can
ada & USA
Certi
fié pour in
stall
a
t
ion
a
u
Canada et
aux
Etats-Unis
.
Listed Room
Hea
ter, Pelletized Fuel Type (Appareil de chauffage à granules certif
ié)
S
uitable For
Mobile Home Installation (A
ccepté
p
our
l'in
st
allation
dan
s une
maison
mobile, test)
Tes t ed
to (Testée selo
n)
:
UL 14 82- 19 98 / ULC S6 27-
00
/ AST M 1 50 9-95 / ULC
S
628-M93
US Environmental P
r
otection Age
ncy, certif
i
ed to comply July 1, 1
990, particulate
emission
st
and
ar
d
s. (
É
tats-Unis Environnem
en
tal
P
r
otection Ag
ence, a certifi
é
p
our
conforme
r
au Juillet
1
,
1990, les normes de particules
d
'émission.)
This pellet appliance ha
s been t
e
st
ed and liste
d
for use in manufactured homes
in
ac
cordance with O
r
egon
A
dminis
t
ration Rules 814-23-900
throug
h
814-23-909.
Install and use
only in accord
ance
with the
Manufac
t
ure’
s
i
ns
t
allation and opera
t
ing instructio
ns. Cont
act local building or
fir
e off
icials about restrictions and
installation inspection in
your
ar
ea.
Do not con
nect
this unit to a chimney flue serving another appli
a
nce. See
local building
codes
and
manufac
turers i
ns
tructions f
or
precautions requ
i
r
ed
for passing a
chimne
y
through a combus
t
ible
wall or ceiling. Elec
tri
cal
r
ating: 120 volts, 60 hz, 4.3 Amps
. R
oute cord away from the heater
.
Cet appa
reil
a été testé et c
erti
fié pour
uti
lisation dans les maisons mobiles en ac
cord avec l
es "Règles Administr
at
ives
de l'O
r
egon
8
14-23-900
à 814-23
-909".
Installez et utilis
ez cet appareil
seulement selon les instruc
t
ions d'installation et
d'opération du fabri
can
t.
Contactez les autorités locales de votre quar
t
ier concernant
le
s restri
c
tions et les inspections
d'ins
t
allation. Consultez les
codes
de bâtiment loc
aux et
les ins
t
r
uct
ions du fabricant pou
r
les préc
autions à
pr
endre
lorsqu
e
une cheminée doit êtr
e instal
lée au travers un mur ou un plaf
ond
combustible. CLASSEMENT ÉLECTRIQUE :
120 Volts, 60
Hz, 4.1 Amps. Pla
cez
le câble électrique loin de la chaleur.
F
o
r
Use With Only
Pelletized W
ood
fuels. Operate only with viewing
door
and ash removal door
closed. Only r
eplace
gl
as
s
wit
h ceramic glass. Components r
equired for
installation: a 3 inch (75 mm)
or
4inch (100 m
m) listed PL vent,
complete with components. Ins
ert and Hearth mount installations; a listed single wall chimne
y
line
r m
ay be u
sed.
Inspect
and clean Exhaus
t
Ve
nt
ing s
ystem frequent
ly.
Utilisation avec les combustibles s
ous
forme de boulets uniquement. Utiliser seulement lor
sque les portes avant
s
et la
porte du récept
acle de cend
re sont
ferm
é
es.
Si une ou des vitr
es devai
ent êtr
e rem
placées, utilisez seulement du
verre
céramique. Les com
p
osantes r
equi
se
s
pour
l'installation sont u
n
évent PL cer
t
ifié d
e 3in/75mm or
4in/1
00m
m av
ec
ses
composantes. Les ins
t
allations inser
t
ion e
t
de mont de foyer
; un
paquebot d
e
cheminée de mur de seul énumér
é peut
être utilisé.
I
nput
Rating (
Les données évaluant): 12,000 to 45,000
BTU/Hr (3.5 to 13.2 kWh)
334
DATE OF MANUFACTURE /
D
ATE DE FABRICATION:
J F M A M J J A S O N D 2009 2010 2011
CAUTION:
Hot while operating. Do not
touch, severe burns may
resu
l
t. Ke
ep children,
clo
t
h
ing,
furniture, gaso
line or ot
h
er
fla
m
mab
le vapor
s
away
.
ATTENTION:
T
r
ès
ch
aud quand allumé.
Ne touc
hez pas,
les brûlures sévères peuvent résulter.
Tenez loin des enf
a
nts, des vêtements, des
meubles,de l’essence ou d’autr
e
s fluides
p
r
o
duisant des vapeurs inf
lammables.
DO NOT REMOVE THIS LABEL /
NE
RETIREZ PAS CETTE ÉTIQUETTE
See installation and operating instructions accompanying appliance. /
Co
nsultez le m
a
nuel avec les instructions d’installation et d’opérat
i
on
.
A Sidewall t
o Uni
t (
Du mur de côté à l
'appareil)
8”
(203 mm
)
B Top of unit to an unshi
elded 8”
(
203
m
m)
mantle
 (Le sommet de
l'unité à
un
m
anteau de chemi
née non blindé)
8”
(
203 mm
)
C
 Unit to top facing (protruding ¾” [
19
m
m
])
(
De
l
'unit
é
au
sommet du parement)
8” (203 m
m
)
D U
nit t
o side
f
aci
ng
(prot
r
udi
ng ¾
[
19
m
m])
(
D
e l'unité au côté du parement)
8”
(203
m
m
)
E From door
opening of unit t
o
edge of floor protection
(De la porte ouvrant au devant de prot
ec
tion de pl
ancher
)
6”
(
152 mm)
F
Fr
om
si
de of unit to edge of floor
pr
ot
ection
(De
l'ouverture
 de porte po
u
r
prendre parti de pr
otecti
on de plancher
)
6” (152
m
m
)
Combus
t
ible flo
ors must
be prot
ec
t
ed by a n
on-com
bu
st
ible material. - See Owner
s Manu
al
.
Le planche
r
combustible doit être protégé par
un mat
ériel incombustible. -
Con
sult
ez le manua
l
.
INSTALLED AS A
FIREPLACE
I
NSERT STOVE MODEL (GFI55) /
A
I
NSTALLE
COMME UN
MODÈLE SUR PIED
D
E POELE.
M
inimum c
l
ear
ances t
o combus
t
ible mater
i
als./
Les
dégagements minimums aux
m
at
ériels c
om
bustibles:
A
Sidewall t
o Uni
t (
Du m
ur de
côté à l
'appareil)
6” (152 m
m)
B Backwall to Unit (Du
m
ur de
der
rière à l'a
pp
a
reil
)
3” (76 mm
)
C C
o
rner t
o Unit
(
D
u coin à l'appareil)
2”
(51
mm)
D
Wal
l to vent (
Le m
ur pour
donner
ven
t
)
3” (76 m
m
)
E Fr
om
door opening of
uni
t to edge of floor protect
ion
(De la porte ouvrant au devant de protection de pla
ncher)
6”
(
152 mm
)
N
OTE: A combu
stibl
e floor must be protecte
d
by a
non-
 combustible mater
i
al -
Width 27" (686mm
)
by depth 34"
 (864mm)
. (Un plancher combust
ible doit etre protege par
un
mater
i
el incombustible. La largeur
27" (686 mm) par la
 profondeur 34" (864mm)
.
)
Minimum
Alco
ve Width (La largeur m
inimum de l'alcove)
36”
(9
14 mm
)
Minimum
Alcove Height (
La hauteur mini
m
um de l
'alcove)
48”
(1219 mm)
M
axi
m
um Alcov
e Depth (La profondeur m
aximum de l
'alcove)
30
(762
mm)
I
N
STALLED AS A FREESTANDI
NG
STOVE
M
ODEL (GF55)
/
A
INSTALLE
COMME
U
N
M
O
DÈLE FS,
QU’IL SOIT ENCASTRÈ, SUR PIED
OU
DA
NS
U
NE M
AISON MOBI
LE.
Minimum clearan
ces t
o combustible materials./ L
es
gagement
s minimums
aux matéri
e
l
s
combustib
l
es:
Ser
i
al
No.
/
No.
De Serié:
Greenfire
GF55 (Stove) GFI55 (Insert)
M
odel /
Modèle:
15956
B
A
D
C
Adjacent
w
all
F
E
Fl
o
or
Pr
ot
e
cti
o
n
A
B
C
E
Backwall
Sidewall
D
Pou
r
démarrer le
poêle: Appuyer sur le bouton "ON/OFF".
Si le Auger n
écessite d'être amorcé, appuyer sur le
b
outon m
a
nuel d'alimentation
du Auger jusqu'à ce que les
granules se d
éver
sent da
ns le
pot de combustion.
Pour faire fonctionner le poêle : MODE MANUEL : Lors
q
ue le feu es
t bien établi, les réglages peuvent
être ajust
é
s
. / MODE "HIGH/LOW" : (N
écessite
un thermostat) Lorsque le t
hermostat requière de la
chaleur, les r
églages p
euvent être ajustés. Lorsque les contacts du
thermostat ouvrent, le réglage du niveau
de chaleu
r
et les ventilateurs s'ajuster
ont au
réglage " bas " jusqu'à ce que les contacts du thermostat se referment. / MODE "AUT
O/OFF" : (
N
écessite un ther
mostat) Lorsque les contacts du th
er
mostat ferment, le
poêle s'allum
era
autom
atique
m
ent. Lorsque la température adéqu
ate est atteinte, les réglages peuvent être ajustés. Lor
sque les conta
c
ts du thermostat ouvre
nt,
l
e poêle s'ajustera aux r
é
glages "
LOW" pendant 30
minutes.
Si
les contact
s du thermostat sont fermés pendant ces 30
m
i
nut
es, le réglage de niveau de chaleur
retournera en rég
lages "
MAN
UEL" ou
si les contacts du thermostat restent ou
v
e
r
ts, le poêle entamera le processus d'arrêt.
P
our
éte
indre le poêle : M
ODE MANU
EL ET " HI
GH/LOW " :
Appuyer sur
le bouton "ON/
OFF".
MODE "AUTO / OFF"
: Régler le ther
mostat à l
a baisse ou
éteignez le.
Manuf
a
c
tur
e
d i
n
Ca
nada f
or /
F
abriqué da
ns
le
Canada pour
:
FPI
Fire
pl
ac
e
Pr
oduct
s I
nt
ernati
o
nal
Ltd.
Delta,
BC,
Canada
M
odel BIH Only Minimum Clearance to Com
bustibl
e Materials / Espace de
dégagem
ent requi
s
pour l
e modèle BIH:
G
B
H
BIH Model
E
FP
I o
r BIH
M
odels
G Fr
om
S
ides and rear
wal
ls to standoffs
(
Les murs côté et mur d'arrière à spacers
)
0” (0 mm)
H
Recess depth
(
Le dos de poêle à une profondeur
)
11”
(280
mm)
FS Model
GF55-081a

This is a copy of the label that accom­panies each GF55 & GFI55. We have printed a copy of the contents here for your reference.
On the GF55 the safety label is located on the underside of the hopper lid.
On the GFI55 the safety label is located on the hopper cover behind the top
INSTALLATION
faceplate.
4
Greenfi re Pellet Stove and Insert Owner's Manual
INSTALLATION
SAFETY WARNINGS & RECOMMENDATIONS
CAUTION:
Do not connect to any air distribution duct or system. Do not burn garbage or fl ammable fl uids such as gasoline, naptha or engine oil. Unit hot while in operation. Keep children, clothing and fur­niture away. Contact may cause skin burns.
FUEL: This pellet stove is designed and approved to only burn wood
pellet fuel with up to 3% ash content. Dirty fuel will adversely affect the operation and performance of the unit and may void the warranty. Check with your dealer for fuel recommendations.
THE USE OF CORDWOOD IS PROHIBITED BY LAW. SOOT: Operation of the stove with insuf cient combustion air will result in
the formation of soot which will collect on the glass, the heat exchanger, the exhaust vent system, and may stain the outside of the house. This is a dangerous situation and is ineffi cient. Frequently check your stove and adjust the slider/damper as needed to ensure proper combustion. See "Slider/Damper Setting".
CLEANING: There will be some build up of fl y ash and small amounts of creosote in the exhaust. This will vary due to the ash content of the fuel used and the operation of the stove. It is advisable to inspect and clean the exhaust vent semi-annually or every two tons of pellets.
ASHES: Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be on a non-combustible floor on the ground, well away from all combustible materials pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispensed, they should be retained in the closed container until all cinders have been thoroughly cooled.
ELECTRICAL: The use of a surge protected power bar is recommended. The unit must be grounded. The grounded electrical
cord should be connected to a standard 115 volts (4.6 Amps), 60 hertz electrical outlet. Be careful that the electrical cord is not trapped under the appliance and that it is clear of any hot surfaces or sharp edges and also must be accessible. If this power cord should become damaged, a replacement power cord must be purchased from the manufacture or a qualifi ed Greenfi re dealer. This unit's maximum power requirement is 520 watts.
SMOKE DETECTOR: Smoke detectors should be installed and
INSTALLATION
maintained in the structure when installing and operating a pellet burning appliance.
OPERATION: The ash pan and door must be closed securely for proper and safe operation of the pellet stove. Also ensure all gaskets on the door are checked and replaced when necessary.
KEEP ASH PAN FREE OF RAW FUEL.
DO NOT PLACE UNBURNED OR NEW PELLET FUEL IN ASH PAN. A FIRE IN THE ASH PAN MAY OCCUR.
INSTALLATION: Be sure to maintain the structural integrity of your home when passing a vent through walls, ceilings, or roofs. It is recommended that the unit be secured into its position in order to avoid any displacement.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
FRESH AIR: Outside Fresh Air connection is optional. Must be connected to all units installed in Mobile and “Air Tight Homes” (R2000) or where required by local codes. Consider all large air moving devices when installing your unit and provide room air accordingly. Limited air for combustion may result in poor performance, smoking and other side effects of poor combustion.
If you have any questions with regards to your stove or the above­mentioned information, please feel free to contact your local dealer for further clarification and comments.
SINCE FPI HAS NO CONTROL OVER THE INSTALLATION OF YOUR STOVE, FPI GRANTS NO WARRANTY IMPLIED OR STA TED FOR THE INSTALLATION OR MAINTENANCE OF YOUR STOVE. THEREFORE, FPI ASSUMES NO RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).
GLASS: Do not abuse the glass by striking or slamming the door. Do not
attempt to operate the stove with broken glass. The stove uses ceramic glass. Replacement glass must be purchased from an Greenfire dealer. Do not attempt to open the door and clean the glass while the unit is in operation or if glass is hot. To clean the glass, use a soft cotton cloth and mild window cleaner, gas or wood stove glass cleaner, or take a damp paper towel and dip into the fly ash. This is a very mild abrasive and will not damage the glass.
FLAMMABLE LIQUIDS: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in the heater. Keep all such liquids well away from the heater while
it is in use.
Greenfi re Pellet Stove and Insert Owner's Manual 5
Loading...
+ 11 hidden pages