Regency GF55 User Manual

GF55 & GFI55
OWNER'S MANUAL
Freestanding and Fireplace
Insert Pellet Stove
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury, property damage, or loss of life. Refer to this manual. For assistance or additional information consult an authorized installer or service agency.
Tested by:
IMPORTANT: SAVE THESE INSTRUCTIONS
GF55-079
FPI FIREPLACE PRODUCTS INTERNATIONAL, LTD. 6988 Venture St., Delta, BC, Canada V4G 1H4
FOR YOUR SAFETY: Do not store or use gasoline or other fl ammable vapours and liquids in the vicinity of this or any other appliance.
Installation and service must be performed by an authorized installer or service agency.
11/14/08
TO THE NEW OWNER
Congratulations! You are the owner of a state-of-the-art Pellet Stove.
Thank-you for purchasing a
FPI FIREPLACE PRODUCT.
The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the GREENFIRE DEALER in your area.
Safety Note: If this stove is not properly installed, a house fi re may result. For your safety, follow the installation instructions, contact local building, fi re offi cials, or authority having jurisdiction about restrictions and installation inspection requirements in your area.
The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit.
2
Greenfi re Pellet Stove and Insert Owner's Manual
TABLE OF CONTENTS
SAFETY LABEL
Copy of Serial No. Decal ...............................................4
INSTALLATION
Safety Warnings & Recommendations ..........................5
Important Safety Information .........................................6
Pellet Quality .................................................................6
OPERATING INSTRUCTIONS
Control Board Functions ................................................7
Automatic Safety Features ............................................7
Operating Your Pellet Stove ..........................................8
Manual Mode ............................................................8
High / Low Mode.......................................................8
Auto / Off Mode .........................................................8
Slider / Damper Set-Up .................................................9
Hopper Grate Installation...............................................9
MAINTENANCE
Routine Cleaning & Maintenance ................................10
Opening the Door ...................................................10
Burn Pot & Liner .....................................................10
Door Glass Cleaning ..............................................10
Ash Pan & Door Gaskets ........................................10
Ash Pan .................................................................. 11
Heat Exchanger Tubes ...........................................11
Fresh Air Intake ...................................................... 11
Exhaust Vent .......................................................... 11
Blower Mechanisms ...............................................11
All Hinges................................................................11
Exhaust Passages ..................................................12
Post Season Clean-Up ...........................................12
Cleaning Plated Surfaces .......................................12
Firebox Panel .........................................................12
Replacing Door Glass.............................................12
WARRANTY
Warranty ......................................................................13
Exclusions and Limitations ..........................................14
Greenfi re Pellet Stove and Insert Owner's Manual 3
SAFETY LABEL
To Start Stove: Press the ON / OFF button. If the auger needs to be primed, press the Manual Auger Feed button until fuel starts to drop into the Burn Pot.
To Operate Stove:
MANUAL
MODE: When a fire
has
been established
the stove settings are adjustable. / HIGH/LOW MODE: (Requires a thermostat) When
the
thermostat
calls for heat the
stove settings are adjustable.
When the thermostat contacts open, the
HEA
T
LEVEL and Fans will drop down to the LOW
setting until the thermostat contacts close again. / AUTO/OFF MODE: (Requires a thermostat) When the thermostat contacts close, the unit will light
automatically. Once up to temperature the stove settings are adjustable. When the thermostat
contacts open,
the stove will drop down to the LOW settings for
30 minutes. If within the 30 min the thermostat contacts close, the
HEA
T
LEVEL will return to previous MANUAL setting or if the thermostat contacts remain
open the stove begin its shutdown routine.
To Turn Off Stove: MANUAL and HI / LOW mode: Press the ON / OFF button
AUTO / OFF mode: Turn the thermostat down or off.
The unit
can be instal
led on a har
d,
stable non-combustible surface.
L'unité peut
être installée sur un dur, la
surface non-combustible stable.r.
Certified for use in Canada & USA
Certifié pour installation au
Canada et aux Etats-Unis.
Listed Room Heater, Pelletized Fuel Type (Appareil de chauffage à granules certifié)
Suitable For Mobile Home Installation (Accepté pour l'installation dans une maison mobile, test)
Tested to (Testée selon):
U
L
14
82-1998 /
ULC S
627-00 / ASTM 1509-95 / U LC S628-
M93
This pellet appliance has been tested and listed for use in manufactured homes in accordance with Oregon
Administration Rules 814-23-900 through 814-23-909. Install and use only in accordance with the Manufacture’s
installation and operating instructions. Contact local building or fire officials about restrictions and installation inspection in
your area. Do not connect this unit to a chimney flue serving another appliance. See local building codes and
manufacturers instructions for precautions required for passing a chimney through a combustible wall or ceiling. Electrical
rating: 120 volts, 60 hz, 4.3 Amps. Route cord away from the heater.
Cet appareil a été testé et certifié pour utilisation dans les maisons mobiles en accord avec les "Règles
Administratives de l'Oregon 814-23-900 à 814-23-909". Installez et utilisez cet appareil seulement selon les
instructions d'installation et d'opération du fabricant. Contactez les autorités locales de votre quartier concernant les
restrictions et les inspections d'installation. Consultez les codes de bâtiment locaux et les instructions du fabricant
pour les précautions à prendre lorsque une cheminée doit être installée au travers un mur ou un plafond
combustible. CLASSEMENT ÉLECTRIQUE : 120 Volts, 60 Hz, 4.1 Amps. Placez le câble électrique loin de la
chaleur.
For Use With Only Pelletized Wood fuels. Operate only with viewing door and ash removal door closed. Only replace
glass with ceramic glass. Components required for installation: a 3 inch (75 mm) or 4inch (100 mm) listed PL vent,
complete with components. Insert and Hearth mount installations; a listed single wall chimney liner may be used. Inspect
and clean Exhaust Venting system frequently.
Utilisation
avec les combustibles sous forme de boulets uniquement.
Utiliser seulement lorsque les portes avants et la
porte du réceptacle de cendre sont fermées. Si une ou des vitres devaient être remplacées, utilisez seulement du
verre céramique. Les composantes requises pour l'installation sont un évent PL certifié de 3in/75mm or 4in/100mm
avec ses composantes.
Les installations insertion et de mont de foyer ; un paquebot de cheminée de mur de seul
énuméré peut être utilisé.
Input Rating (Les données évaluant): 12,000 to 45,000 BTU/Hr (3.5 to 13.2 kWh
)
334
DATE OF MANUFACTURE /
DATE DE FABRICATION:
GF55-081 J F M A M J J A S O N D 2008 2009 2010
CAUTION:
Hot while operating. Do not
touch, severe burns may
result. Keep children, clothing,
furniture, gasoline or other
flammable vapors away
.
ATTENTION:
Très chaud quand allumé. Ne touchez pas,
les brûlures sévères peuvent résulter.
Tenez loin des enfants, des vêtements, des
meubles,de l’essence ou d’autres fluides
produisant des vapeurs inflammables.
DO NOT REMOVE THIS LABEL /
NE RETIREZ PAS CETTE ÉTIQUETTE
See installation and operating instructions accompanying appliance. /
Consultez le manuel avec les instructions d’installation et d’opération
.
A Sidewall to Unit (Du mur de côté à l'appareil)
8” (203 mm)
B Top of unit to an unshielded 8” (203 mm) mantle
 (Le sommet de l'unité à un manteau de cheminée non blindé) 8” (203 mm)
C
Unit to top facing (protruding ¾” [19 mm])
(
De l'unité au sommet du parement)
8” (203 mm)
D Unit to side facing (protruding ¾” [19 mm])
(
De l'unité au côté du parement)
8” (203 mm)
E From door opening of unit to edge of floor protection
(De la porte ouvrant au devant de protection de plancher) 6”
(152 mm)
F From side of unit to edge of floor protection
(De l'ouverture
 de porte pour prendre parti de protection de plancher) 6” (152 mm)
Combustible floors must be protected by a
non-combustible material.
- See Owners Manual.
Le plancher combustible doit être protégé par
un matériel incombustible.
- Consultez le manual.
INSTALLED AS A FIREPLACE INSERT STOVE MODEL (GFI55) / A INSTALLE
COMME UN MODÈLE SUR PIED DE POELE.
Minimum clearances to combustible materials./ Les dégagements minimums aux matériels
combustibles:
A Sidewall to Unit (Du mur de côté à l'appareil)
6” (152 mm)
B Backwall to Unit (Du mur de derrière à l'appareil)
3” (76 mm)
C
Corner to Unit (Du coin à l'appareil)
2” (51 mm)
D Wall to vent (Le mur pour donner vent) 3” (76 mm)
E From door opening of unit to edge of floor protection
 (De la porte ouvrant au devant de protection de plancher) 6”
(
152
mm)
NOTE: A combustible floor m
us
t be protected by a
non-
c
om
bustible m
ateri
al - Width 27"
(686m
m) by depth 34"
(
864mm). (
U
n plancher
combusti
ble
doi
t etre
prote
g
e
par un
mater
i
el incombust
ible. La largeur
27" (686 m
m) par la
pr
ofondeur 34" (86
4mm).)
 Minimum Alcove Width (La largeur minimum de l'alcove)
36
” (914 mm)
 Minimum Alcove Height (La hauteur minimum de l'alcove) 48” (1219 mm)
 Maximum Alcove Depth (La profondeur maximum de l'alcove) 30
” (762 mm)
INSTALLED AS A FREESTANDING STOVE MODEL (GF55) / A INSTALLE COMME UN
MODÈLE FS, QU’IL SOIT ENCASTRÈ, SUR PIED OU DANS UNE MAISON MOBILE.
Minimum clearances to combustible materials./ Les dégagements minimums aux matériels
combustibles:
Serial No. / No. De Serié:
Greenfire GF55 (Stove) GFI55 (Insert)
Model / Modèle:
15956
B
A
D
C
Adjacent wal
l
F
E
Floor Protection
A
B
C
E
Backwall
Sidewall
D
Pour démarrer le poêle: Appuyer sur le bouton "ON/OFF". Si le Auger nécessite d'être amorcé, appuyer sur le bouton manuel d'alimentation du Auger jusqu'à ce que les granules se déversent dans le pot de combustion.
Pour faire fonctionner le poêle
:
MODE MANUEL : Lorsque le
feu est bien établi, les réglages peuvent être ajustés. / MODE "HIGH/LOW" : (Nécessite un
thermostat)
Lorsque le thermostat
requière de la
chaleur, les réglages peuvent être ajustés. Lorsque les contacts
du
thermostat ouvrent, le réglage du niveau de chaleur et les ventilateurs s'ajusteront au réglage " bas " jusqu'à ce que les contacts du thermostat se referment. / MODE "AUTO/OFF" : (Nécessite un thermostat) Lorsque
les contacts du thermostat ferment, le poêle
s'allumera
automatiquement. Lorsque la température adéquate est atteinte, les réglages peuvent être ajustés. Lorsque les contacts du thermostat
ouvrent, le poêle s'ajustera aux réglages
"LOW" pendant 30 minutes. Si les contacts du thermostat sont fermés pendant
ces 30
minutes, le réglage de niveau de chaleur retournera en réglages "MANUEL" ou si les contacts du thermostat restent ouverts, le poêle entamera le processus d'arrêt.
Pour éteindre le poêle : MODE MANUEL
ET " HIGH/LOW " :
Appuyer sur le bouton "ON/OFF".
MODE "AUTO / OFF" : Régler le thermostat à la baisse ou éteignez le.
Manufactured in Canada for /
Fabriqué dans le Canada pour:
FPI Fireplace Products International Ltd.
Delta, BC, Canada
This is a copy of the label that accom­panies each GF55 & GFI55. We have printed a copy of the contents here for your reference.
On the GF55 the safety label is located on the underside of the hopper lid.
On the GFI55 the safety label is located on the hopper cover behind the top
INSTALLATION
faceplate.
4
Greenfi re Pellet Stove and Insert Owner's Manual
SAFETY WARNINGS & RECOMMENDATIONS
CAUTION:
Do not connect to any air distribution duct or system. Do not burn garbage or fl ammable fl uids such as gasoline, naptha or engine oil. Unit hot while in operation. Keep children, clothing and fur­niture away. Contact may cause skin burns.
INSTALLATION
INSTALLATION
SMOKE DETECTOR: Smoke detectors should be installed and maintained in the structure when installing and operating a pellet burning
appliance.
OPERATION: The ash pan and door must be closed securely for proper and safe operation of the pellet stove. Also ensure all gaskets on the door are checked and replaced when necessary.
FUEL: This pellet stove is designed and approved to only burn wood pellet fuel with up to 3% ash content. Dirty fuel will adversely affect the operation and performance of the unit and may void the warranty. Check with your dealer for fuel recommendations.
THE USE OF CORDWOOD IS PROHIBITED BY LAW.
SOOT: Operation of the stove with insuf cient combustion air will result in
the formation of soot which will collect on the glass, the heat exchanger, the exhaust vent system, and may stain the outside of the house. This is a dangerous situation and is ineffi cient. Frequently check your stove and adjust the slider/damper as needed to ensure proper combustion. See "Slider/Damper Setting".
CLEANING: There will be some build up of fl y ash and small amounts of creosote in the exhaust. This will vary due to the ash content of the fuel used and the operation of the stove. It is advisable to inspect and clean the exhaust vent semi-annually or every two tons of pellets.
ASHES: Disposed ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be on a non-combustible floor on the ground, well away from all combustible materials pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispensed, they should be retained in the closed container until all cinders have been thoroughly cooled.
ELECTRICAL: The use of a surge protected power bar is recommended. The unit must be grounded. The grounded electrical
cord should be connected to a standard 115 volts (4.6 Amps), 60 hertz electrical outlet. Be careful that the electrical cord is not trapped under the appliance and that it is clear of any hot surfaces or sharp edges and also must be accessible. If this power cord should become damaged, a replacement power cord must be purchased from the manufacture or a qualifi ed Greenfi re dealer. This unit's maximum power requirement is 520 watts.
KEEP ASH PAN FREE OF RAW FUEL.
DO NOT PLACE UNBURNED OR NEW PELLET FUEL IN ASH PAN. A FIRE IN THE ASH PAN MAY OCCUR.
INSTALLATION: Be sure to maintain the structural integrity of your home when passing a vent through walls, ceilings, or roofs. It is recommended that the unit be secured into its position in order to avoid any displacement.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING
ANOTHER APPLIANCE.
FRESH AIR: Outside Fresh Air connection is optional. Must be connected to all units installed in Mobile and “Air Tight Homes” (R2000) or where required by local codes. Consider all large air moving devices when installing your unit and provide room air accordingly. Limited air for combustion may result in poor performance, smoking and other side effects of poor combustion.
If you have any questions with regards to your stove or the above­mentioned information, please feel free to contact your local dealer for further clarification and comments.
SINCE FPI HAS NO CONTROL OVER THE INSTALLATION OF YOUR STOVE, FPI GRANTS NO WARRANTY IMPLIED OR STATED FOR THE INSTALLATION OR MAINTENANCE OF YOUR STOVE. THEREFORE, FPI ASSUMES NO RESPONSIBILITY FOR ANY CONSEQUENTIAL DAMAGE(S).
GLASS: Do not abuse the glass by striking or slamming the door. Do not
attempt to operate the stove with broken glass. The stove uses ceramic glass. Replacement glass must be purchased from an Greenfire dealer. Do not attempt to open the door and clean the glass while the unit is in operation or if glass is hot. To clean the glass, use a soft cotton cloth and mild window cleaner, gas or wood stove glass cleaner, or take a damp paper towel and dip into the fly ash. This is a very mild abrasive and will not damage the glass.
FLAMMABLE LIQUIDS: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in the heater. Keep all such liquids well away from the heater while
it is in use.
Greenfi re Pellet Stove and Insert Owner's Manual 5
Loading...
+ 11 hidden pages