Raymarine E70111, E70110, T203, E70113, T220 Installation And Operation Instructions Manual

...
T200
Installation and operation instructions
English
Date: 06-2013 Document number: 81349-2-EN © 2013 Raymarine UK Limited
Chapter1:Importantinformation
Warning:Productinstallationand operation
Thisproductmustbeinstalledandoperatedin accordancewiththeinstructionsprovided.Failure todosocouldresultinpersonalinjury ,damageto yourvesseland/orpoorproductperformance.
Warning:Potentialignitionsource
ThisproductisNOTapprovedforusein hazardous/ammableatmospheres.DoNOTinstall inahazardous/ammableatmosphere(suchasin anengineroomornearfueltanks).
Warning:Productgrounding
Beforeapplyingpowertothisproduct,ensureithas beencorrectlygrounded,inaccordancewiththe instructionsinthisguide.
Warning:Switchoffpowersupply
Ensurethevessel’spowersupplyisswitchedOFF beforestartingtoinstallthisproduct.DoNOT connectordisconnectequipmentwiththepower switchedon,unlessinstructedinthisdocument.
Warning:Ensuresafenavigation
Thisproductisintendedonlyasanaidtonavigation andmustneverbeusedinpreferencetosound navigationaljudgment.Onlyofcialgovernment chartsandnoticestomarinerscontainallthe currentinformationneededforsafenavigation,and thecaptainisresponsiblefortheirprudentuse.Itis theuser’sresponsibilitytouseofcialgovernment charts,noticestomariners,cautionandproper navigationalskillwhenoperatingthisoranyother Raymarineproduct.
Warning:Maintainapermanent watch
Alwaysmaintainapermanentwatch,thiswillallow youtorespondtosituationsastheydevelop. Failuretomaintainapermanentwatchputs yourself,yourvesselandothersatseriousriskof harm.
Caution:Powersupplyprotection
Wheninstallingthisproductensurethepower sourceisadequatelyprotectedbymeansofa suitably-ratedfuseorautomaticcircuitbreaker.
Caution:Serviceandmaintenance
Thisproductcontainsnouserserviceable components.Pleasereferallmaintenance andrepairtoauthorizedRaymarinedealers. Unauthorizedrepairmayaffectyourwarranty .
Cleaningthethermalcamera
Thecamerahousingandlenswillrequireoccasionalcleaning. Raymarinesuggeststhatyoucleanthelenswhenimagequality degradationisnoticedorexcessivecontaminantbuildupisseen. Cleantheinterfacebetweentheyokeandbaseoftentoprevent accumulationofdebrisorsaltdeposits.
Whencleaningthisproduct:
•DoNOTwipethelenswindowwithadrycloth,asthiscould scratchthecoating.
•DoNOTuseabrasive,oracidorammoniabasedproducts.
•DoNOTpressurewash.
Particularcareshouldbetakenwhencleaningthelenswindow, thishasaprotectiveanti-reectivecoatingwhichmaybe damagedbyimpropercleaning.
1.Switchoffthepowertotheunit.
2.Cleanthecamerabodywithaclean,softcottoncloth.Y ou
canmoistentheclothanduseamilddetergentifrequired.
3.Cleanthecameralens.
•Rinsethelenswithfreshwatertoremovealldirtparticles andsaltdeposits,andallowtodrynaturally.
•Ifanyspotsorsmearsremain,verygentlywipethelens windowwithacleanmicrobreclothorsoftcottoncloth.
•Ifnecessary,useisopropylalcohol(IPA)oramilddetergent toremoveanyremainingspotsormarks.
Wateringress
Wateringressdisclaimer Althoughthewaterproofratingcapacityofthisproductmeets
theIPX6standard,waterintrusionandsubsequentequipment failuremayoccuriftheproductissubjectedtocommercial high-pressurewashing.Raymarinewillnotwarrantproducts subjectedtohigh-pressurewashing.
Disclaimer
Raymarinedoesnotwarrantthatthisproductiserror-freeorthat itiscompatiblewithproductsmanufacturedbyanypersonor entityotherthanRaymarine.
Raymarineisnotresponsiblefordamagesorinjuriescausedby youruseorinabilitytousetheproduct,bytheinteractionofthe productwithproductsmanufacturedbyothers,orbyerrorsin informationutilizedbytheproductsuppliedbythirdparties.
EMCinstallationguidelines
Raymarineequipmentandaccessoriesconformtothe appropriateElectromagneticCompatibility(EMC)regulations, tominimizeelectromagneticinterferencebetweenequipment andminimizetheeffectsuchinterferencecouldhaveonthe performanceofyoursystem
CorrectinstallationisrequiredtoensurethatEMCperformance isnotcompromised.
ForoptimumEMCperformancewerecommendthatwherever possible:
•Raymarineequipmentandcablesconnectedtoitare:
–Atleast1m(3ft)fromanyequipmenttransmittingor
cablescarryingradiosignalse.g.VHFradios,cablesand antennas.InthecaseofSSBradios,thedistanceshould beincreasedto7ft(2m).
–Morethan2m(7ft)fromthepathofaradarbeam.A
radarbeamcannormallybeassumedtospread20degrees aboveandbelowtheradiatingelement.
•Theproductissuppliedfromaseparatebatteryfromthatused forenginestart.Thisisimportanttopreventerraticbehavior anddatalosswhichcanoccuriftheenginestartdoesnot haveaseparatebattery .
Importantinformation
•Raymarinespeciedcablesareused.
•Cablesarenotcutorextended,unlessdoingsoisdetailedin theinstallationmanual.
Note:Whereconstraintsontheinstallationprevent anyoftheaboverecommendations,alwaysensurethe
maximumpossibleseparationbetweendifferentitemsof electricalequipment,toprovidethebestconditionsforEMC performancethroughouttheinstallation
Chapter2:Handbookandproductinformation
Chaptercontents
2.1Handbookinformationonpage10
2.2Productinformationonpage10
Handbookandproductinformation
2.1Handbookinformation
ThishandbookdescribestheinstallationofRaymarineT200 Seriesxedmountthermalcamerasaspartofamarine electronicssystem.
Thishandbookincludesinformationtohelpyou:
•planyourthermalimagingsystemandensureyouhaveallthe necessaryequipment,
•installandconnectthethermalcameraasapartofyour systemofRaymarineelectronics,
•obtainsupportifrequired.
Handbooks
DescriptionPartnumber
T200SeriesInstallationandOperations Handbook
81349
T200SeriesMountingT emplate
87190
2.2Productinformation
TheT200seriesxedmountthermalcamerasconsistofasealed cameraballassemblyandaremovableoutercover.Theouter coverisnotintendedtoprovidesealing.Thecameraprovides analogvideooutputthroughastandardF-typeconnectionand receivespowerfromitsPoweroverEthernet(PoE)interface.
D12865-1
ThefollowingvariantsoftheT200seriesxedmountthermal cameraareavailable:
PartnumberDescription
E7011 1
T200–Thermalcamera320x240(9Hz)NTSC
E70110
T203–Thermalcamera320x240(30Hz)NTSC
E70113
T220–Thermalcamera320x240(9Hz)P AL
E70112
T223–Thermalcamera320x240(25Hz)P AL
E70121
T250–Thermalcamera640x480(9Hz)NTSC
E70120
T253–Thermalcamera640x480(30Hz)NTSC
E70123
T270–Thermalcamera640x480(9Hz)P AL
E70122
T273–Thermalcamera640x480(25Hz)P AL
Note:TheT200Seriesarexedmountcameraswiththe panandtiltanglessetduringinstallation.Panandtiltcannot bechangedremotely.
T200
Chapter3:Planningtheinstallation
Chaptercontents
3.1Thermalcameracontrollersanddisplaysonpage12
3.2Installationchecklistonpage12
3.3Typicalsystemsonpage13
3.4Partssuppliedonpage14
3.5T oolsrequiredonpage15
Planningtheinstallation
3.1Thermalcameracontrollersand
displays
Atypicalthermalcamerasystemcomprisesofathermalcamera, acontrollerandadisplay .Thedisplayandthecontrollermaybe separateorintegrated.
D12838-1
1 2
3
5
4
1.Thermalcamera.
2.RaymarineMultifunctiondisplay—Integrateddisplayand
controller.
3.JoystickControlUnit(JCU)—Controlleronly.
4.LaptoporPC—Controlleronly .
5.Videomonitor—Displayonly.
Additionalequipment
Youmayhaveadditionalequipmentaspartofyourthermal camerasystem:
•Multiplemultifunctiondisplaysandcontrollers.
•SeaT alk
hs
networkswitch–Usedtocreateanetworkof
compatibleRaymarineequipment.
Compatiblemultifunctiondisplays
ThefollowingRaymarinemultifunctiondisplaysarecompatible withyourthermalcamera.
•cSeries(PoweroverEthernet(PoE)injectorrequired)
•eSeries(PoweroverEthernet(PoE)injectorrequired)
•gSSeries
3.2Installationchecklist
Installationincludesthefollowingactivities:
InstallationT ask
1Planyoursystem.
2
Obtainallrequiredequipmentandtools.
3
Siteallequipment.
4Routeallcables.
5
Drillcableandmountingholes.
6Makeallconnectionsintoequipment.
7
Secureallequipmentinplace.
8Poweronandtestthesystem.
Schematicdiagram
Aschematicdiagramisanessentialpartofplanningany installation.Itisalsousefulforanyfutureadditionsor maintenanceofthesystem.Thediagramshouldinclude:
•Locationofallcomponents.
•Connectors,cabletypes,routesandlengths.
T200
3.3Typicalsystems
Examplec/eSeriessystem
D12839-1
3
2
1
4
5
1Thermalcamera.
2
c/eSeriesmultifunctiondisplay(Integrateddisplayand controller).
3
PoweroverEthernet(PoE)injector.
4
RayNettoSeaT alk
hs
cable.
5
Videocable.
ExamplegSSeriessystem
3 4
D12840-1
2
1
5
1Thermalcamera.
2
gSSeriesmultifunctiondisplay(Integrateddisplayand controller).
3Ethernetcoupler .
4
RayNettoSeaT alk
hs
cable.
5
Videocable.
Note:WhenconnecteddirectlytoagSSeriesmultifunction displaythethermalcameraissuppliedwithpowerover ethernetfromthedisplay .
ExampleSystemwithJCU
D12841-1
7
98
2
1
3
5
4
6
9
1
c/eSeriesmultifunctiondisplay(Integrateddisplayand controller).
2Thermalcamera.
3Videoinputcable.
4Networkswitch.
5
JCU(Optionalcontroller).
6
PoweroverEthernet(PoE)injector(Requiredtosupply powertotheJCU).
7
PoweroverEthernet(PoE)injector(Requiredtosupply powertothethermalcamera).
8RayNetcable.
9
RayNettoSeaT alk
hs
cable.
ExamplesystemwithJCUanddisplay
D12842-1
6
7
8
2
1
3
4
5
8
1
VideoDisplay(Displayonly).
2Thermalcamera.
3Videoinputcable.
4
JCU(RequiredController).
5
PoweroverEthernet(PoE)injector(Requiredtosupply powertotheJCU).
6
PoweroverEthernet(PoE)injector(Requiredtosupply powertothethermalcamera).
7
Networkswitch.
8
RayNettoSeaT alk
hs
cable.
ExamplesystemwithPCcontrolleranddisplay
D12843-1
2
6
5
1
7 5
3
4
1
VideoDisplay(Displayonly).
2Thermalcamera.
3Videoinputcable.
Planningtheinstallation
4Networkswitch.
5
RayNettoSeaT alk
hs
cable.
6
PoweroverEthernet(PoE)injector(Requiredtosupply powertothethermalcamera).
7
Laptop(Controlleronly).
3.4Partssupplied
x6 x6 x6
x6
x4
x1
1
5
11
12
13
2 3
4
6
8
7
9
10
D12844-1
ItemDescriptionQuantity
1Thermalcamera.1
2Ethernetcoupler .1
3
PoweroverEthernet(PoE)Injector.
1
6
6
6
4
Mountingkit,consistingof:
•M8nylocknut
•acornnut
•stud
•washer
6
5
O-ring.
1
6
Top-downxings.
4
7
Documentationpack.1
8
Groundingstrapsecuringnut.
1
2
2
9Videoconnectors:
•FemaletofemaleF-typeconnector
•FemaleF-typetoMaleRCAadaptor
•FemaleF-typetoBNCconnector
2
10Zipties.3
11
1m(3.28ft.)RayNettoSeaT alk
hs
cable.
1
12
7.7m(25ft.)Ethernetcable.
1
13
7.7m(25ft.)Coaxialvideocable.
1
Unpackthecameraunitcarefullytopreventdamage.Savethe cartonandpackingincasetheunithastobereturnedforservice.
Additionalitemsrequired
Tocompletetheinstallationyouwillalsoneedtoobtainthe followingitems:
T200
•Chassisgroundstrap.
•Compatibledisplay/controllerhardware.
•Cablesforvideoconnections.
•PowercableforPoEinjector(ifusingthePoEinjector).
•Threadlockingcompound(e.g.Loctite242orequivalent), requiredforallmetal-to-metalthreadedconnections.
•Marinegradesealingtape(e.g.3MScotch-Seal2229or equivalent).
3.5Toolsrequired
Thefollowingtoolsarerequiredforinstallation.
D1233 3-1
1
2
3
4
5
6
ItemDescription
1.Drill.
2.
10mm(7/16inch)spanner.
3.
6.4mmdrillbit(forbottomdown installation).
4.
Jigsaw(onlyrequiredforJCU installation).
5.
Pozi-drivescrewdriver(onlyrequired forJCUinstallation).
6.Thread-lock.
Planningtheinstallation
Chapter4:Cablesandconnections
Chaptercontents
4.1Generalcablingguidanceonpage18
4.2Connectionsoverviewonpage18
4.3Chassisgroundconnectiononpage19
4.4Externalorinternalconnectionsonpage19
4.5Networkandpowerconnectiononpage20
4.6Videoconnectiononpage21
4.7PoEconnectiononpage21
4.8PCconnectiononpage23
Cablesandconnections
4.1Generalcablingguidance
Cabletypesandlength
Itisimportanttousecablesoftheappropriatetypeandlength
•Unlessotherwisestateduseonlystandardcablesofthe correcttype,suppliedbyRaymarine.
•Ensurethatanynon-Raymarinecablesareofthecorrect qualityandgauge.Forexample,longerpowercablerunsmay requirelargerwiregaugestominimizevoltagedropalongthe run.
Routingcables
Cablesmustberoutedcorrectly,tomaximizeperformanceand prolongcablelife.
•DoNOTbendcablesexcessively .Whereverpossible,ensure aminimumbenddiameterof200mm(8in)/minimumbend radiusof100mm(4in).
100mm (4in)
200mm (8in)
•Protectallcablesfromphysicaldamageandexposuretoheat. Usetrunkingorconduitwherepossible.DoNOTruncables throughbilgesordoorways,orclosetomovingorhotobjects.
•Securecablesinplaceusingtie-wrapsorlacingtwine.Coil anyextracableandtieitoutoftheway .
•Whereacablepassesthroughanexposedbulkheador deckhead,useasuitablewatertightfeed-through.
•DoNOTruncablesneartoenginesoruorescentlights.
Alwaysroutedatacablesasfarawayaspossiblefrom:
•otherequipmentandcables,
•highcurrentcarryingacanddcpowerlines,
•antennae.
Strainrelief
Ensureadequatestrainreliefisprovided.Protectconnectors fromstrainandensuretheywillnotpulloutunderextremesea conditions.
Cableshielding
Ensurethatalldatacablesareproperlyshieldedthatthe cableshieldingisintact(e.g.hasn’tbeenscrapedoffbybeing squeezedthroughatightarea).
Warning:Productgrounding
Beforeapplyingpowertothisproduct,ensureithas beencorrectlygrounded,inaccordancewiththe instructionsinthisguide.
4.2Connectionsoverview
D12845-1
1
3
2
1.Chassisground
2.Analogvideoconnection—IRoutput.
3.Ethernet–T oRaymarinenetworkswitch,multifunction display,orJCU.
Connectioncarepoints:
•Thecabletailsshouldberoutedtoadryareaofthevesselfor
connection.Alternativelyyoumustensurethatallconnections aremadewatertight.
T200
4.3Chassisgroundconnection
Thechassisgroundstudshouldbeconnectedtothevessel groundpoint.
D12846-1
Thenut(supplied)shouldbeusedtosecureagroundstrap(not supplied)tothebaseofthethermalcamera.Aringterminal typicallysizedfor#6orM3sizedstudandgauge14togauge16 wireshouldbeusedforthestrap.
Note:Ensurethatthegroundstrapdoesnotinterferewith mountingthecamera.
4.4Externalorinternalconnections
Thecableconnectionscanbemadeexternallyorinternally .
External
Assupplied,thecameracabletailsextendthroughthebase andareconnectedexternally:
D12847-1
Internal
Optionallyyoucanmakethecableconnectionsinternally.
D12848-1
Tomakeinternalconnections,bringthecabletailsupthroughthe baseandusethesuppliedethernetcouplerandvideoconnector tomaketheconnectionsinternally.Theethernetcouplercanbe xedtothecameraballassemblyusingthezipties(supplied).
Cablesandconnections
4.5Networkandpowerconnection
Thethermalcameraissuppliedpowerbyandcontrolledusing theethernetnetworkconnection.
CameratomultifunctiondisplaywithPoE
FormultifunctiondisplaysthatsupportPoE,thefollowing suppliedequipmentisrequired:
•RayNettoRJ45SeaT alk
hs
cable.
•Ethernetcoupler.
CameratomultifunctiondisplaywithoutPoE
FormultifunctiondisplaysthatdonotsupportPoE,thefollowing suppliedequipmentisrequired:
•PoEinjector.
•RayNettoRJ45SeaT alk
hs
cable.
•Ethernetcoupler
Cameratoanetworkswitch
ToconnectthethermalcameratoaRaymarinenetworkswitch, thefollowingsuppliedequipmentisrequired:
•7.6m(25ft)Ethernetcable.
•Ethernetcoupler
•PoEinjector.
•RayNettoRJ45SeaT alk
hs
cable.
PoweroverEthernet(PoE)injector
APoEinjectorisrequiredwhenconnectingthethermalcamera toaRaymarinenetworkswitchortoamultifunctiondisplaythat doesnotsupportPoE.AnadditionalPoEinjectorisrequired whenconnectingaJCU.
JoystickControlUnit(JCU)
ToconnectaJCUtheethernetcable(suppliedwiththeJCU), PoEinjectorandaRayNettoSeaT alk
hs
networkcableare required.TheJCUissuppliedwitha7.6m(25ft)ethernetcable forthisconnection.Ifyourequireadifferentlengthcontactyour dealerforsuitablecables.
Note:ThePoEinjectormustbemountedinadryarea.
Networkcables
RayNettoRayNetcables
CablePartnumber
400mm(1.3ft)RayNettoRayNet cable(female)
A80161
2m(6.56ft)RayNettoRayNetcable (female)
A62361
5m(16.4ft)RayNettoRayNetcable (female)
A80005
10m(32.8ft)RayNettoRayNet cable(female)
A62362
20m(65.6ft)RayNettoRayNet cable(female)
A80006
50mm(1.97in)RayNettoRayNet cable(male)
A80162
RayNetright-angledcouplerA80262
RayNetcablepuller5-packR70014
RayNettoRJ45SeaTalk
hs
adaptercables
CablePartnumber
1m(3.28ft)RayNettoRJ45 SeaTalk
hs
cable
A62360
3m(9.84ft)RayNettoRJ45 SeaTalk
hs
cable
A80151
CablePartnumber
10m(32.8ft)RayNettoRJ45 SeaTalk
hs
cable
A80159
400mm(1.3ft)RayNettoRJ45 SeaTalk
hs
(female)cable
A80160
T200
4.6Videoconnection
Videocablesandconnectorsarerequiredtoconnecttheanalog videoconnectiontoasuitabledisplay.
Note:Thevideosignalisanalogonlyandisnotavailable overethernet.
Videocables
Ifyourequirevideocablesorconnectorsotherthanthose suppliedwiththeproductpleasecontactyourlocalauthorized Raymarinedealer.
RaymarinerecommendstheuseofaBNCterminatedRG59 75ohm(orbetter)coaxialcable.
4.7PoEconnection
APoEinjectorisrequiredwhenconnectingthethermalcamera toanetworkswitchoramultifunctiondisplaythatdoesnot supportPoE.AnadditionalPoEinjectorisrequiredwhen connectingaJCU.
ThePoEinjectorrequiresa12V/24Vdcpowersupply.
D12849 -1
3
4
1
1
2
1
12V/24VdcpowersupplyconnectiontoPoEinjector.(Power cableNOTsupplied;refertoPoEpowerconnectionforsuitable cables.)
2
SeaTalk
hs
connection(tonetworkswitchormultifunction
display).
3PoEInjector.
4
Ethernetconnection(tothermalcameraorJCU).
PoEpowerconnection
ThePoEinjectorrequiresadedicatedpowercablefordirect connectiontoa12V/24Vpowersupply .
Theunitisintendedforuseondc“negative”or“oating”ground powersystems.
Raymarinerecommendsthatallpowerconnectionsaremade viaadistributionpanel.Allequipmentmustbeeither:
•poweredfromacircuitbreakerorswitch,with5Acircuit protection,or
•poweredfroma5Aslowblowin-linefuseconnectedtothe REDpositivewireofthepowercable.
Theunitdoesnothaveapowerswitch.Theunitispowered whenthepowercableisconnectedtothevessel'spowersupply.
Note:Theunitshouldbemountedsothatthepowercable canbeeasilyremovedifnecessary.Iftheunitisplacedina difculttoreachlocation,Raymarinerecommendsinstalling anon/offswitchonthepowerconnectionatapointthatis easilyaccessible.
Recommendedpowercablesizes
Cablelength
Wiresize
FeetMetres
AWG
mm
2
103142.1
154.6142.1
206123.3
257.6123.3
309105.3
Note:
•Cablelengthisthedistancebetweenthepowersource andtheunit.
•Thesewiresizesgiveatotaldropofabout0.5Vbetween thepowersourceandtheunit,achievingaminimumvoltage attheunitof10.5Vwithafullyatbatteryat1 1V .
Cablesandconnections