Ransburg RMA202 T User Manual

Ransburg
SERVICE MANUAL
LN-9527-00.1
RMA-202 TEST STAND
100 100
100100 100 100 100
SHAPING AIRATOM AIR
SEAL AIRBEARING AIR
MODEL: 77918-08 FOR RMA-202
IMPORTANT: Before using this equipment, carefully read SAFETY PRECAUTIONS, starting on page 1, and all instructions in this manual. Keep this Service Manual for future reference.
Ransburg
CONTENTS
SAFETY:
RMA-202 Test Stand - Safety
PAGE
1-5
SAFETY PRECAUTIONS..............................................................................................................
HAZARDS / SAFEGUARDS..........................................................................................................
INTRODUCTION:
GENERAL INFORMATION............................................................................................................
SPECIFICATIONS.........................................................................................................................
FEATURES....................................................................................................................................
INSTALLATION:
SETUP PROCEDURE...................................................................................................................
INITIAL TEST SETTINGS..............................................................................................................
HIGH VOLTAGE TEST................................................................................................................
TROUBLESHOOTING HV TEST.................................................................................................
TEST TRIGGERS..........................................................................................................................
PRESSURIZED WATER TESTS...................................................................................................
TURBINE TESTS..........................................................................................................................
PREPARARATION OF APPLICATOR FOR PRODUCTION PLACEMENT................................
MAINTENANCE:
MAINTENANCE.............................................................................................................................19
1 2-5
6-8
6 7 7-8
9-17
9 9 9-10 11-12 12-13 13-14 14-17 17-18
19
WARRANTY POLICIES:
LIMITED WARRANTY ..................................................................................................................
APPENDIX:
PAINT AND SOLVENT SPECIFICATIONS.................................................................................
VISCOSITY CONVERSION CHART.............................................................................................
VOLUMETRIC CONTENT OF HOSE OR TUBE..........................................................................
LN-9527-00.1
20
20
21-24
21 22-23 24
RMA-202 Test Stand - Safety
SAFETY
Ransburg
SAFETY PRECAUTIONS
Before operating, maintaining or servicing any Ransburg electrostatic coating system, read and understand all of the technical and safety liter­ature for your Ransburg products. This manual contains information that is important for you to know and understand. This information relates to USER SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this informa­tion, we use the following symbols. Please pay particular attention to these sections.
A WARNING! states information to alert you to a situation that might cause serious injury if instructions are not followed.
A CAUTION! states information that tells how to prevent damage to equipment or how to avoid a situation that might cause minor injury.
A NOTE is information relevant to the proce­dure in progress.
W A R N I N G
!
 The user MUST read and be familiar with
the Safety Section in this manual and the
Ransburg safety literature therein identied.
 This manual MUST be read and thor-
oughly understood by ALL personnel who operate, clean or maintain this equipment! Special care should be taken to ensure that the WARNINGS and safety requirements for operating and servicing the equipment are followed. The user should be aware of and
adhere to ALL local building and re codes
and ordinances as well as NFPA-33 SAFE­TY STANDARD, LATEST EDITION, prior
to installing, operating, and/or servicing this equipment.
W A R N I N G
!
While this manual lists standard specications
and service procedures, some minor deviations may be found between this literature and your equipment. Differences in local codes and plant requirements, material delivery requirements, etc., make such variations inevitable. Compare this manual with your system installation draw­ings and appropriate Ransburg equipment man­uals to reconcile such differences.
Careful study and continued use of this manual will provide a better understanding of the equipment
and process, resulting in more efcient operation,
longer trouble-free service and faster, easier troubleshooting. If you do not have the manuals and safety literature for your Ransburg system, contact your local Ransburg representative or Ransburg.
 The hazards shown on the following pag- es may occur during the normal use of this equipment. Please read the hazard chart be­ginning on page 2.
1
LN-9527-00.1
Ransburg
RMA-202 Test Stand - Safety
AREA
Tells where hazards may occur.
Spray Area
HAZARD
Tells what the hazard is.
Fire Hazard
Improper or inadequate operation and maintenance
procedures will cause a re
hazard.
Protection against inadver­tent arcing that is capable of
causing re or explosion is
lost if any safety interlocks are disabled during opera­tion. Frequent Power Supply or Controller shutdown indi­cates a problem in the system requiring correction.
SAFEGUARDS
Tells how to avoid the hazard.
Fire extinguishing equipment must be present in
the spray area and tested periodically.
Spray areas must be kept clean to prevent the accumulation of combustible residues.
Smoking must never be allowed in the spray area.
The high voltage supplied to the atomizer must be turned off prior to cleaning, ushing or main­tenance.
When using solvents for cleaning:
Those used for equipment ushing should
have ash points equal to or higher than
those of the coating material.
• Those used for general cleaning must have
ash points above 100°F (37.8°C).
Spray booth ventilation must be kept at the rates required by NFPA-33, OSHA, country, and local codes. In addition, ventilation must be main­tained during cleaning operations using am­mable or combustible solvents.
Electrostatic arcing must be prevented. Safe sparking distance must be maintained between the parts being coated and the applicator. A dis­tance of 1 inch for every 10KV of output voltage is required at all times.
Test only in areas free of combustible material. Testing may require high voltage to be on, but only as instructed.
Non-factory replacement parts or unautho-
rized equipment modications may cause re or
injury.
If used, the key switch bypass is intended for use only during setup operations. Production should never be done with safety interlocks dis­abled.
Never use equipment intended for use in water­borne installations to spray solvent based ma­terials.
The paint process and equipment should be set up and operated in accordance with NFPA­33, NEC, OSHA, local, country, and European Health and Safety Norms.
LN-9527-00.1
2
RMA-202 Test Stand - Safety
Ransburg
AREA
Tells where hazards may occur.
Spray Area
HAZARD
Tells what the hazard is.
Explosion Hazard
Improper or inadequate oper­ation and maintenance proce-
dures will cause a re hazard.
Protection against inadvertent arcing that is capable of caus-
ing re or explosion is lost if
any safety interlocks are dis­abled during operation.
Frequent Power Supply or Controller shutdown indicates a problem in the system requir­ing correction.
SAFEGUARDS
Tells how to avoid the hazard.
Electrostatic arcing must be prevented. Safe sparking distance must be maintained between the parts being coated and the applicator. A dis­tance of 1 inch for every 10KV of output voltage is required at all times.
Unless specically approved for use in hazard­ous locations, all electrical equipment must be located outside Class I or II, Division 1 or 2 hazardous areas, in accordance with NFPA-33.
Test only in areas free of ammable or combus­tible materials.
The current overload sensitivity (if equipped)
MUST be set as described in the correspond­ing section of the equipment manual. Protec­tion against inadvertent arcing that is capable
of causing re or explosion is lost if the current
overload sensitivity is not properly set. Fre­quent power supply shutdown indicates a prob­lem in the system which requires correction.
General Use and Maintenance
Improper operation or mainte­nance may create a hazard.
Personnel must be properly trained in the use of this equip­ment.
Always turn the control panel power off prior to
ushing, cleaning, or working on spray system
equipment.
Before turning high voltage on, make sure no objects are within the safe sparking distance.
Ensure that the control panel is interlocked with the ventilation system and conveyor in accor­dance with NFPA-33, EN 50176.
Have re extinguishing equipment readily avail­able and tested periodically.
Personnel must be given training in accordance with the requirements of NFPA-33, EN 60079-0.
Instructions and safety precautions must be read and understood prior to using this equip­ment.
Comply with appropriate local, state, and na­tional codes governing ventilation, re protec­tion, operation maintenance, and housekeep­ing. Reference OSHA, NFPA-33, EN Norms and your insurance company requirements.
3
LN-9527-00.1
Ransburg
RMA-202 Test Stand - Safety
AREA
Tells where hazards may occur.
Spray Area / High Voltage Equipment
HAZARD
Tells what the hazard is.
Electrical Discharge
There is a high voltage device that can induce an electrical charge on ungrounded objects which is capable of igniting coating materials.
Inadequate grounding will cause a spark hazard. A spark can ignite many coating
materials and cause a re or explosion.
SAFEGUARDS
Tells how to avoid the hazard.
Parts being sprayed and operators in the spray area must be properly grounded.
Parts being sprayed must be supported on con­veyors or hangers that are properly ground­ed. The resistance between the part and earth
ground must not exceed 1 meg ohm. (Refer to NFPA-33.)
Operators must be grounded. Rubber soled in­sulating shoes should not be worn. Grounding straps on wrists or legs may be used to assure adequate ground contact.
Operators must not be wearing or carrying any ungrounded metal objects.
When using an electrostatic handgun, operators must assure contact with the handle of the ap­plicator via conductive gloves or gloves with the palm section cut out.
NOTE: REFER TO NFPA-33 OR SPECIFIC COUNTRY SAFETY CODES REGARDING PROPER OPERATOR GROUNDING.
All electrically conductive objects in the spray area, with the exception of those objects re­quired by the process to be at high voltage, must
be grounded. Grounded conductive ooring
must be provided in the spray area.
Always turn off the power supply prior to ush­ing, cleaning, or working on spray system equip­ment.
Unless specically approved for use in hazard­ous locations, all electrical equipment must be located outside Class I or II, Division 1 or 2 haz­ardous areas, in accordance with NFPA-33.
LN-9527-00.1
4
RMA-202 Test Stand - Safety
Ransburg
AREA
Tells where hazards may occur.
Electrical Equipment
HAZARD
Tells what the hazard is.
Electrical Discharge
High voltage equipment is uti­lized in the process. Arcing
in the vicinity of ammable or
combustible materials may oc-
cur. Personnel are exposed to
high voltage during operation and maintenance.
Protection against inadvertent
arcing that may cause a re or explosion is lost if safety circuits
are disabled during operation.
Frequent power supply shut­down indicates a problem in the system which requires correc­tion.
An electrical arc can ignite coat-
ing materials and cause a re or explosion.
SAFEGUARDS
Tells how to avoid the hazard.
Unless specically approved for use in hazard­ous locations, the power supply, control cabinet, and all other electrical equipment must be locat­ed outside Class I or II, Division 1 and 2 hazard­ous areas in accordance with NFPA-33 and EN
50176.
Turn the power supply OFF before working on the equipment.
Test only in areas free of ammable or combus­tible material.
Testing may require high voltage to be on, but only as instructed.
Production should never be done with the safety circuits disabled.
Before turning the high voltage on, make sure no objects are within the sparking distance.
Toxic Substances
Spray Area
Certain material may be harmful if inhaled, or if there is contact with the skin.
Explosion Hazard – Incompatible Materials
Halogenated hydrocarbon sol-
vents for example: methylene
chloride and 1,1,1,-Trichlo­roethane are not chemically compatible with the aluminum that might be used in many sys­tem components. The chemical reaction caused by these sol­vents reacting with aluminum can become violent and lead to
an equipment explosion.
Follow the requirements of the Material Safety Data Sheet supplied by coating material manu­facturer.
Adequate exhaust must be provided to keep the air free of accumulations of toxic materials.
Use a mask or respirator whenever there is a chance of inhaling sprayed materials. The mask must be compatible with the material being sprayed and its concentration. Equipment must be as prescribed by an industrial hygienist or
safety expert, and be NIOSH approved.
Aluminum is widely used in other spray appli­cation equipment - such as material pumps, regulators, triggering valves, etc. Halogenated hydrocarbon solvents must never be used with
aluminum equipment during spraying, ushing,
or cleaning. Read the label or data sheet for the material you intend to spray. If in doubt as to whether or not a coating or cleaning material is compatible, contact your coating supplier. Any other type of solvent may be used with aluminum equipment.
5
LN-9527-00.1
Ransburg
INTRODUCTION
RMA-202 Test Stand - Introduction
GENERAL INFORMATION
The Ransburg Applicator Performance Test Stand was developed to assist in determining
the applicator level of performance in an off-line condition. Insuring the applicator functions properly after any maintenance has been performed to it off-line reduces the costs associated with verifying performance during production. With line speeds critical to the through-put of a facility, every uptime
minute counts to underwrite protability. This Test
Stand device helps to insure the applicator per­forms correctly when it is put into service.
The Test Stand will verify performance of single or
dual uid applicators, bearing air, seal air, shaping
air, brake air and atomizing air. It also checks for kV and µA electrical performance of the applicator.
The Test Stand was developed with the user and the safety of the user in mind. The user must become familiar with the overall function and operation of the unit.
SPECIFICATIONS
Electrical / Physical
Power Requirements:
110/120 v AC
Air Requirements:
1” NPT (F) Inlet
3/4” ID Air Line to Stand
100 psi (6.4 bar) (90 psig Min. @ 20 SCFM) Min.
0.3 to 0.6 Micron Filtration
Dimensions: Height: 67” (1702 cm) Width: 30” (762 cm) Length: 48” (1219 cm)
Fluids: Use distilled or de-ioniz-
ed water only for testing
Maximum Fluid Pressure: 80 psi (5.2 bar)
N O T E
> For all test stand toggle switches, with the switch lever in the “UP” position, the valve it describes is “ON” or “actuated.”
Test Specication Summary
At Voltage: 90 - 100 KV
20 µa Max.
Fluid Leaks: No pressure drop for 2 minutes
Bearing Air Flow Rate: 1.5 to 2.5 SCFM
Turbine Air Flow At 50K rpm: 14 SCFM Max.
Shaping Air Flow: 8 - 13 SCFM at 25 psig 17 - 21 SCFM at 60 psig
Seal Air: 9 - 11 SCFM at 30 psig
Fiber Optic Voltage: .68V at 50K RPM Min.
LN-9527-00.1
6
RMA-202 Test Stand - Introduction
FEATURES
Ransburg
100 10 0
100100 100 100 100
ATOM AIR SHAPING AIR
BEARING AIR SEAL AIR
Figure 1: Basic Stand Features
BASIC STAND FEATURES
Item #
1
2
3
4
5
6
7
8
Main Control Panel
Air Flow Meters
Test Applicator
Table
Pressure Pot
Dump Bucket
Spin Guard
Main Air Regulator
7
Description
LN-9527-00.1