Quantum Scalar 10K Release Notes

Release Notes
Product
Date
Scalar® 10K 320A.00004
September 2007

Contents 0

Purpose of This Release ................................................................................................ 1
New Features and Enhancements............................................................................... 2
Resolved Issues .............................................................................................................. 3
Known Issues ................................................................................................................. 5
Documentation............................................................................................................... 6
Contacting Quantum..................................................................................................... 7

Purpose of This Release 0

The Scalar 10K 320 release includes new features and enhancements that extend its capabilities. These release notes describe these new features and enhancements, as well as currently known issues and issues that were resolved for this release of the product. These notes also provide drive and auxiliary firmware compatibility information. Visit information about the Scalar 10K and previous releases.
© September 2007 Quantum Corporation. All rights reserved. Document 6-00016-32 Rev A
Quantum, Scalar, DLT, DLTtape, the Quantum logo, and the DLTtape logo are all registered trademarks of Quantum Corporation. SDLT and Super DLTtape are trademarks of Quantum Corporation. LTO and Ultrium are trademarks of HP, IBM and Quantum in the U.S.A. and other countries. Other trademarks are the property of their respective companies.
http://www.quantum.com for additional
Release Notes Document 6-00016-32 Rev A September 2007

New Features and Enhancements 0

The Scalar 10K 320 release includes the following new features and enhancements:
The Scalar 10K tape library now supports the integration of IBM LTO-4 Fibre Channel 4 Gb drives.
The posting of Tape Alerts is now configurable.
Tape Alert log data is returned so that SDLC can generate reports.

Compatibility Matrix 0

See the following table for information on drive and auxiliary firmware compatibility with the 320 release of Scalar 10K 320A.00004. This information is current as of this product release. For the most up to date information on Quantum Global Services, please visit:
www.quantum.com/support
Drive Firmware
S10K Release
Library Firmware: 320A.00004
Component Firmware Version
RMU 210A.00002
Scalar DLC 2.7
AMC/LMC 4.5.1/1.5.1
SNC
SNC 3000 3.42.18
SNC 5100 4.45.22
Drive Types
Quantum DLT 8000 V80
Quantum SDLT 220 V94
Quantum SDLT 320 (SCSI) V96
IBM LTO-1 (SCSI) 5AU1
1
IBM LTO-1 (FC) 5AU1
IBM LTO-2 (SCSI) 67U1
IBM LTO-2 (FC) 67U1
IBM LTO-3 (FC) 2G 73P5
IBM LTO-3 (FC) 4G 73P5
2 New Features and Enhancements
Release Notes
Document 6-00016-32 Rev A
September 2007
Drive Firmware
S10K Release
Library Firmware: 320A.00004
Component Firmware Version
IBM LTO-4 (FC) 4G 75X2
IBM 3590 E1A / H1A / B1A DOIF_2D4
IBM 3592-J1A D310_A0D
IBM TS1120 D3I1_B25
AIT-2 0203 001
AIT-3 0209_0001
Note: The library assigns 12-character logical serial numbers to 3592-J1A tape drives. If you use IBM Tivoli® Storage
Manager (TSM), install a version of the TSM device driver that is later than maintenance release 5.2.4.4 (for TSM
5.2) or later than 5.3.1.1 (for TSM 5.3) to ensure that TSM can properly identify 3592-J1A tape drives according to their 12-character logical serial numbers.

Resolved Issues 0

This release of Scalar 10K firmware resolved the following issues..
Change Request Number
Version 320A.00004
1588 Aux trace screen shows tower numbers in hex.
1589 Need change to display location of print log port.
1727 Inserting AIT-3 tapes always causes retries. Handling too high on the top
2551 342084 Operator Panel warning when moving tapes outside of COD licensed
2603 S10K log file corruptions (various).
2747 History log shows wrong initiator.
2806 427194 When one IE station door is being taught and inventoried the RES to all
2807 Need to have option to speed up I/E station teach operations.
2825 DLT-8000 Sleds incorrectly log a stepper motor task fails to start.
2841 Get/put window test doesn't reserve library, interference with auto
2844 Get SAC 7C and Library TA flag 13 instead of TA flag 2 when move tape
Service Request Number
Description
magazine cell.
slots.
other IE stations can be incorrect.
reteach.
to blocked storage
Resolved Issues 3
Release Notes Document 6-00016-32 Rev A September 2007
Change Request Number
Service Request Number
Description
2876 Logical serial number (12 character) causing configuration errors with
TSM application.
2911 IVT test does not run LTO move cartridge test in 4th IE.
2931 418156 Library should compare drive fiducial labels with actual sled type.
2938 Service login timeout is handled incorrectly at "service->verify->all-
>perform all tests" screen if the 'Accept' input is 'y' when the timeout occurs.
2939 Remove fibre channel topology and data rate selection for LTO-1 FC
drives.
2974 S10K Tape alert flags are reported incorrectly in the S10K log and need a
mechanism to report tape alert log data back to SDLC.
3024 550364 If the IE cable between the IE and the LMC becomes disconnected and a
new teach is performed the teach fails with SAC 01, 40, A3.
3031 On large dual aisle systems, it has been observed that tower 13 sometimes
fails to teach new on the secondary aisle side.
3032 566896 Serial number and logical serial number are truncated by 1 character on
the operator panel.
3038 527016 E_LSC_WFSCRDBF_BAD_READBUFFER_HANDLE is reported with
RMU 192 and 304 Library firmware.
3041 622572 If a LTO barcode label is printed in the reverse direction the library
incorrectly places the label into the bottom cell and forces a rescan.
3045 Need to merge changes form CR64557(support of LB and LX media for
3592 drives) onto main tree for 320.
3050 582456 On systems with a lot of drives (70+ drives), the Log sense page 3B
interferes with vary on of drive causing SAC 71.
3071 Need to add changes (DDC\LDC\LBI boot \appl code problem 313 code)
to 320 code.
3073 3592 drive modules power supply diags for the 4th drive bay do not work
properly.
3074 S10K 314A FW does not identify media type and usage.
3075 3592 short media returns an incorrect media character through SCSI read
element status.
3081 Code can take the library offline and not post an error.
3352 When varying a drive offline the library does not queue a unit attention
until the menu is exited. It should queue the UA as soon as the drive has been varied offline and not wait for the user to exit the menu.
4 Resolved Issues
Release Notes
Document 6-00016-32 Rev A
September 2007

Known Issues 0

This release of Scalar 10K firmware has the following known issues. This list contains cumulative information for the previously released versions.
Change
Request
Number
33359 282830 On occasion, the vertical mounting
40518 When a Teach Current operation is
41203 When using a data tape instead of a
Service
Request
Number
Description Workaround
of a 3590 tape drive might be higher than the vertical window expected by the library firmware to successfully scan for the drive fiducial. As a result, the library cannot teach the drive.
performed for a DM, a drive teach failure can return an incorrect bay number to the Operator Panel.
FUP tape to update a list of drives, the library correctly posts a “BAD FIRMWARE MEDIA” operator intervention message, but continues to the next drive in the list. The operation should fail and not continue.
Manually adjust the vertical placement of the 3590 tape drive or the front bezel until the library can successfully teach the drive.
Physically inspect the drive bay that the failure indicated or possibly the bay that is located immediately before. The bay that is identified by the failure might not exist.
No applicable workaround is available.
41301 After cleaning cartridges are ejected
from drives, the View dialog (Main MenuSetupCleaningView) continues to indicate a Valid status for the first cleaning cartridge rather than clearing the status.
Known Issues 5
Make sure that cleaning cartridges are inserted into the library by using the Insert Clean Tape command (Main MenuCommands Insert/ EjectInsert Clean Tape). This operation physically inserts the cartridges and also inserts them into the library database.
NOTE: Do not use Main Menu SetupCleaningMedia to perform this operation. This operation inserts the cartridges into the library database only.
Release Notes Document 6-00016-32 Rev A September 2007
Change Request Number
41305 The usage count for the first cleaning
Service Request Number
Description Workaround
cartridge increments when a second cleaning cartridge is used.
Make sure that cleaning cartridges are inserted into the library by using the Insert Clean Tape command (Main MenuCommands Insert/ EjectInsert Clean Tape). This operation physically inserts the cartridges and also inserts them into the library database.
NOTE: Do not use Main Menu SetupCleaningMedia to perform this operation. This operation inserts the cartridges into the library database only.

Documentation 0

The following documents are currently available for the Scalar 10K.
Document Number Document Title
6-01023-02 Rev A Scalar 10K Unpacking Instructions
6-01337-04 Rev A Scalar 10K Planning Guide
6-00058-05 Rev A Scalar 10K Operator Guide
6-01338-04 Rev A Scalar 10K SCSI Reference Manual
6 Documentation
Release Notes
Document 6-00016-32 Rev A
September 2007

Contacting Quantum 0

More information about this product is available on the Service and Support website at
www.quantum.com/support. The Service and Support Website contains a collection of
information, including answers to frequently asked questions (FAQs). You can also access software, firmware, and drivers through this site.
For further assistance, or if training is desired, contact Quantum:
Quantum Technical Assistance Center in the USA:
For additional contact information:
To open a Service Request:
For the most updated information on Quantum Global Services, please visit:
www.quantum.com/support
+1 800-284-5101
www.quantum.com/support
www.quantum.com/esupport
Contacting Quantum 7
Loading...