Promise Technology J610S, J310S User Manual

0 (0)

VTRAK

J610S,J310S

PRODUCT MANUAL

Version 1.1

VTrak J610s, J310s Product Manual

Copyright

© 2007 Promise Technology, Inc. All Rights Reserved.

Copyright by Promise Technology, Inc. (Promise Technology). No part of this manual may be reproduced or transmitted in any form without the expressed, written permission of Promise Technology.

Trademarks

Promise, and the Promise logo are registered in U.S. Patent and Trademark Office. All other product names mentioned herein may be trademarks or registered trademarks of their respective companies.

Important data protection information

You should back up all data before installing any drive controller or storage peripheral. Promise Technology is not responsible for any loss of data resulting from the use, disuse or misuse of this or any other Promise Technology product.

Notice

Although Promise Technology has attempted to ensure the accuracy of the content of this manual, it is possible that this document may contain technical inaccuracies, typographical, or other errors. Promise Technology assumes no liability for any error in this publication, and for damages, whether direct, indirect, incidental, consequential or otherwise, that may result from such error, including, but not limited to loss of data or profits.

Promise Technology provides this publication “as is” without warranty of any kind, either express or implied, including, but not limited to implied warranties of merchantability or fitness for a particular purpose.

The published information in the manual is subject to change without notice. Promise Technology reserves the right to make changes in the product design, layout, and driver revisions without notification to its users.

This version of the Product Manual supersedes all previous versions.

Recommendations

In this Product Manual, the appearance of products made by other companies, including, but not limited to software, servers and disk drives, is for the purpose of illustration and explanation only. Promise Technology does not recommend, endorse, prefer, or support any product made by another manufacturer.

ii

Contents

Chapter 1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Architectural Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Warranty and Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

CE Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

FCC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

GOST-R Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

IRAM Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

MIC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Chapter 2: Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Unpacking the VTrak . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9

Mounting VTrak J610s in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . .11

Mounting VTrak J310s in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . .13

Installing Disk Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16

Drive Numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19

Setting Up Data Cable Connections . . . . . . . . . . . . . . . . . . . . . . . .20

Basic DAS Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

Cascading DAS Connection . . . . . . . . . . . . . . . . . . . . . . . . . . .23

Redundant DAS Connection . . . . . . . . . . . . . . . . . . . . . . . . . . .25

Setting Up Serial Cable Connections . . . . . . . . . . . . . . . . . . . . . . .27

Connecting the Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28

Setting Up the CLI Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . .29

Chapter 3: Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31

Front Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31

Drive Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32

I/O Module Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33

CLI Command Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35

Cable Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35

Enclosure Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36

Information List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36

Viewing Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36

Settings List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38

Making Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39

Help Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39

Link Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40

iii

VTrak J610s, J310s Product Manual

Chapter 3: Management, cont.

CLI Command Set, cont.

Viewing Link Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 Clearing the Error Count . . . . . . . . . . . . . . . . . . . . . . . . . . .42 Route Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42 Route Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 Uptime Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 VPDR Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44 ? Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44

Chapter 4: Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45

Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45

Contacting Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46

Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49

Returning Product For Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50

Appendix A: Second I/O Module . . . . . . . . . . . . . . . . . . . . . . . . . . . .

53

Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

55

iv

Chapter 1: Introduction

About This Manual (below)

Overview (page 2)

Architectural Description (page 4)

Features and Benefits (page 5)

Specifications (page 6)

Thank you for purchasing Promise Technology’s VTrak J610s or J310s external disk array subsystem.

About This Manual

This Product Manual describes how to setup, use and maintain the VTrak J610s or J310s external disk subsystem. It also describes how to use the built-in command-line interface (CLI) software.

This manual includes a full table of contents, index, chapter task lists and numerous cross-references to help you find the specific information you are looking for.

Also included are four levels of notices:

Note

A Note provides helpful information such as hints or alternative ways of doing a task.

Important

An Important calls attention to an essential step or point required to complete a task. Important items include things often missed.

Caution

A Caution informs you of possible equipment damage or loss of data and how to avoid them.

Warning

A Warning notifies you of probable equipment damage or loss of data, or the possibility of physical injury, and how to avoid them.

1

VTrak J610s, J310s Product Manual

Overview

The Promise VTrak J610s and J310s are optimized for organizations deploying cost-effective small-to-medium application clusters, disk-to-disk backup and midrange storage solutions.

Figure 1. VTrak J610s front view

Drive Carrier LEDs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drive Carriers

Power and Status LEDs

 

Figure 2. VTrak J310s front view with bezel removed

Drive Carrier LEDs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drive Carriers

Power and Status LEDs

 

The dual 3Gb SAS host interface ports offer the ease of management and performance required by companies running popular departmental and backoffice applications including file/print, e-mail, database and Web services

2

Promise Technology J610S, J310S User Manual

Chapter 1: Introduction

Figure 3. VTrak J610s rear view

 

I/O module 1

 

I/O module 2

 

 

 

 

 

 

 

 

115200

115200

8 N 1

8 N 1

Power Supply 1

Cooling Unit 1

Cooling Unit 2 Power Supply 2

Figure 4. VTrak J310s rear view

 

Power Supply 1

Cooling Unit 1

Cooling Unit 2 Power Supply 2

O

 

O

I

 

I

115200

8 N 1

115200

8 N 1

I/O module 1

I/O module 2

The two external SAS ports provide the needed connectivity and bandwidth for large capacity solutions requiring multiple JBOD boxes cascaded together while still providing dual server support and host port failover or aggregation.

3

VTrak J610s, J310s Product Manual

Architectural Description

The VTrak J610s packs up to 16 drives per system, offering industry-leading capacity in just 3U of standard 19-inch rack space. The VTrak J310s supports up to 12 drives per system, in just 2U of standard 19-inch rack space. The J610s and J310s unit’s compact form factor maximizes density, increasing capacity per unit of rack space.

Multiple J610s and J310s systems can also be connected to the same server using standard SAS features to deliver massive storage to capacity hungry applications such as disk-to-disk backup, media archiving, video surveillance and compliance storage

Promise has designed the J610s and J310s chassis to be fully compatible with all future Promise external storage products. By using the same chassis, drive carriers, and cooling units, upgrading the RAID controllers and JBOD modules is fast and simple.

With the VTrak J610s and J310s, Promise has dramatically narrowed the gap between simple fault tolerance and No Single Point of Failure. The VTrak J610s and J310s use a fully redundant, hot-swap design and continuously monitors all system components. It can withstand failures to disks, power supplies, cooling and I/O modules without interrupting system operation.

4

 

 

Chapter 1: Introduction

 

 

 

 

Features and Benefits

 

 

 

 

 

 

Feature

Benefit

 

 

 

 

3U or 2U 19-inch wide enclosure

Installs easily in any standard rackmount.

 

 

 

 

Supports Serial Attached SCSI

Allows you to use the new dual-port SAS

 

disk drives

disk drives.

 

 

 

 

Supports Serial ATA disk drives

Allows you to use your legacy SATA disk

 

 

drives.

 

 

 

 

Hot-swap feature for drive carriers,

Allows a defective component to be

 

I/O modules, power supplies and

replaced without interrupting data

 

fans

accessibility to the host system.

 

 

 

 

Tool-less field-replaceable units

All FRUs can be replaced without tools,

 

(FRUs)

saving time and effort for support personnel.

 

 

 

 

Complete cable-less design

All components easily plug directly into

 

 

boards. No cables to complicate setup or

 

 

maintenance.

 

 

 

 

Redundant, hot-swappable cooling

Load sharing and full operation even with

 

units

multiple failed fans.

 

 

 

 

Redundant, hot-swappable power

Load sharing and full operation even with a

 

supplies

failed power supply.

 

 

 

 

Dual, active/active I/O Modules

High level of availability even with a failed

 

 

I/O module.

 

 

 

 

One expansion SAS port I/O

Enables cascading JBOD subsystems.

 

module

 

 

 

 

 

 

Command-line interface

Control and monitoring with simple,

 

 

straightforward interface.

 

 

 

 

Management through in-band SAS

Choice of local or network management

 

or serial port

options

 

 

 

 

Compatible with leading SAS HBA

Easy, works-the-first-time connections with

 

and RAID cards

your current systems

 

 

 

 

5

VTrak J610s, J310s Product Manual

Specifications

Drive Capacity: J610s, 16 drives. J310s, 12 drives.

External I/O Ports: SAS host port and SAS expansion port.

Supported Disk Interfaces: Serial Attached SCSI (SAS) and Serial ATA (SATA), 3Gb/s and 1.5Gb/s

Supported Operating Systems:

Windows Vista, Business,

RedHat Linux

 

Enterprise, or Ultimate

SuSE Linux

Windows 2003 Server

Novell Netware

Windows XP Professional

Sun Solaris

 

 

Windows 2000

The list above refers to 32-bit and 64-bit versions of the OS in the Host PC or server. The actual OS support depends upon your SAS HBA or RAID adapter. Check your SAS HBA or RAID adapter user documentation.

Voltage: 100–240 VAC Auto-ranging.

Current: 8 A @ 100 VAC; 4 A @ 240 VAC Current rating with two power cords

Power Consumption (not including disk drives):

J610s, 108.38 W.

J310s, 100.87 W.

Power Consumption (including disk drives):

J610s, 523.91 W.

J310s, 412.51 W.

Power Supply:

J610s, Dual 500W, 100–240 VAC auto-ranging, 50–60 Hz, dual hot swap and redundant with PFC, N+1 design.

J310s, Dual 400W, 100–240 VAC auto-ranging, 50–60 Hz, dual hot swap and redundant with PFC, N+1 design.

Operating Temperature:

5° to 40°C operational

-40° to 60°C non-operational Relative Humidity: Maximum 95%

Vibration: Random, 0.21 grms, 5 to 500 Hz, 30 Mins, X, Y, Z axis

6

Chapter 1: Introduction

Dimensions (H x W x D):

J610s, 13.1 x 44.7 x 56.1 cm (5.2 x 17.6 x 22.1 in)

J310s, 8.8 x 44.7 x 56.1 cm (3.5 x 17.6 x 22.1 in)

Net Weight:

J610s, 30.5 kg (67.2 lb) without drives, 38.5 kg (84.9 lb) with 16 drives, assuming 0.5 kg (1.1 lb) per drive.

J310s, 26.5 kg (58.4 lb) without drives, 32.5 kg (71.7 lb) with 12 drives, assuming 0.5 kg (1.1 lb) per drive.

Gross Weight (including carton):

J610s, 37.5 kg (82.7 lb) without drives.

J310s, 33.0 kg (72.8 lb) without drives.

Safety: CE, FCC Class A, VCCI, C-Tick, cUL, TUV, CB, BSMI, MIC.

Warranty and Support

Warranty: Three years complete system limited warranty.

Support: 24x7 email and phone support (English only). 24x7 access to Promise support site for drivers, firmware, and compatibility.

CE Statement

Warning: This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and

(2) this device must accept any interference received, including interference that may cause undesired operation.

GOST-R Statement

ɉɪɟɞɭɩɪɟɠɞɟɧɢɟ. Ⱦɚɧɧɵɣ ɩɪɨɞɭɤɬ ɨɬɧɨɫɢɬɫɹ ɤ ɤɥɚɫɫɭ A. ȼ ɞɨɦɚɲɧɢɯ ɭɫɥɨɜɢɹɯ ɨɧ ɦɨɠɟɬ ɛɵɬɶ ɩɪɢɱɢɧɨɣ ɜɨɡɧɢɤɧɨɜɟɧɢɹ ɪɚɞɢɨɩɨɦɟɯ, ɜ ɷɬɨɦ ɫɥɭɱɚɟ ɩɨɥɶɡɨɜɚɬɟɥɸ, ɜɨɡɦɨɠɧɨ, ɩɨɬɪɟɛɭɟɬɫɹ ɩɪɢɧɹɬɶ ɫɨɨɬɜɟɬɫɬɜɭɸɳɢɟ ɦɟɪɵ.

7

VTrak J610s, J310s Product Manual

IRAM Statement

Advertencia: Este es un producto de clase A. En un ambiente doméstico, este producto puede causar interferencia de las ondas de radio, en cuyo caso se podría requerir que el usuario tome las medidas adecuadas.

MIC Statement

8

Chapter 2: Installation

Unpacking the VTrak (below)

Mounting VTrak J610s in a Rack (page 11)

Mounting VTrak J310s in a Rack (page 13)

Installing Disk Drives (page 16)

Setting Up Data Cable Connections (page 20)

Setting Up Serial Cable Connections (page 27)

Connecting the Power (page 28)

Setting Up the CLI Connection (page 29)

Unpacking the VTrak

The VTrak J610s or J310s box contains the following items:

• Front bezel and key (J310s only)

Left and right mounting rails

• RJ11-to-DB9 serial data cable

Left and right center-mount brackets

(Units with one I/O module: 1)

(Units with two I/O modules: 2)

1.5m (4.9 ft) Power cords (2)

• 1.0m (3.3 ft) SFF-8088 4X to 4X

CD with Product Manual and Quick

external SAS cable

 

Start Guide

(Units with one I/O module: 1)

Screws for disk drives

(Units with two I/O modules: 2)

• VTrak J610s or J310s Unit

• Quick Start Guide

 

(J610s: 70, including 6 spares)

 

 

(J310s: 50, including 2 spares)

Warning

The electronic components within the VTrak are sensitive to damage from Electro-Static Discharge (ESD). Observe appropriate precautions at all times when handling the VTrak or its subassemblies.

9

VTrak J610s, J310s Product Manual

Figure 1. VTrak J610s rear view

 

I/O module 1

 

I/O module 2

 

 

 

 

 

 

 

 

115200

115200

8 N 1

8 N 1

Power Supply 1

Cooling Unit 1

Cooling Unit 2 Power Supply 2

Figure 2. VTrak J310s rear view

 

Power Supply 1

Cooling Unit 1

Cooling Unit 2 Power Supply 2

O

 

O

I

 

I

115200

8 N 1

115200

8 N 1

I/O module 1

I/O module 2

Some VTraks ship with a single I/O module and a blank unit installed in the place of the second I/O module. You can upgrade your VTrak by installing a second I/O module. See page 53.

Some VTraks ship with a single power supply and an auxiliary cooling unit installed in the place of the second power supply to provide a comparable level of air circulation inside the enclosure.

10

Chapter 2: Installation

Mounting VTrak J610s in a Rack

The J610s subsystem installs to the rack using the supplied mounting rails. You can also use your existing rails.

Figure 3. VTrak J610s mounted in a rack with the supplied rails

Vertical Rack Post

VTrak J610s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Handles mount

Mounting rails (included)

outside the rack post

mount outside the rack post

Cautions

At least two persons are required to safely lift, place, and attach the VTrak subsystem into a rack system.

Do not lift or move the VTrak subsystem by the handles, power supplies or the controller units. Hold the subsystem itself.

Do not install the VTrak subsystem into a rack without rails to support the subsystem.

Only a qualified electrician who is familiar with the installation procedure should mount and install the VTrak subsystem.

Be sure all switches are OFF before installing the VTrak subsystem or exchanging components.

To install the J610s subsystem into a rack with the supplied mounting rails:

1.Check the fit of the mounting rails in your rack system. See Figure 4.

2.Adjust the length of the mounting rails as needed.

3.Attach the mounting rail assemblies to the outside of the rack posts, using the attaching screws from your rack system.

Be sure the support is on the bottom facing inward.

11

VTrak J610s, J310s Product Manual

4.Square the rail assemblies in the rack.

5.Tighten the adjustment screws and the attaching screws.

6.Place the VTrak subsystem onto the rails.

7.Secure the VTrak subsystem to the rack through each handle, using the attaching screws from your rack system.

Figure 4. Rack mount assembly diagram

Rack front post

Rack back post

Rail attaching screw

Rail attaching screw

(not included)

(not included)

Front rail

Rear rail

Flange

Support

Rail adjustment screw

Rail adjustment screw

Inside of post

Inside of post

 

12

Chapter 2: Installation

Mounting VTrak J310s in a Rack

The J310s subsystem installs to the rack using the supplied mounting rails. You can also use your existing rails.

Figure 5. VTrak J310s mounted in a rack with the supplied rails

Vertical Rack Post

VTrak J310s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Handles mount

Mounting rails (included)

outside the rack post

mount outside the rack post

Cautions

At least two persons are required to safely lift, place, and attach the VTrak subsystem into a rack system.

Do not lift or move the VTrak subsystem by the handles, power supplies or the controller units. Hold the subsystem itself.

Do not install the VTrak subsystem into a rack without rails to support the subsystem.

Only a qualified electrician who is familiar with the installation procedure should mount and install the VTrak subsystem.

Be sure all switches are OFF before installing the VTrak subsystem or exchanging components.

To install the VTrak subsystem into a rack with the supplied mounting rails:

1.Check the fit of the mounting rails in your rack system. See Figure 7.

2.Slide the plates out of the mounting rails.

3.Attach one plate to each side of the VTrak subsystem.

Line-up the six holes in the plate with the corresponding holes in the subsystem. Attach each plate with six screws (included). See Figure 6.

4.Slide one of the rails over the plate on one side of the enclosure.

13

VTrak J610s, J310s Product Manual

The rail is designed to slide freely over the plate.

5.Attach a flange to each end of the rail, with the rail on the opposite side of the flange from the two-hole bracket.

6.Install the rail adjustment screws (included) through the flange into the rail. There are four screws for each flange. See Figure 7.

7.Place the subsystem with mounting rails into your rack system.

8.Attach the mounting rail assemblies to the outside of the rack posts, using the attaching screws from your rack system.

9.Square the rail assemblies in the rack.

10.Tighten the adjustment screws and the attaching screws.

11.Place the VTrak subsystem onto the rails.

12.Secure the VTrak subsystem to the rack through each handle, using the attaching screws from your rack system.

Figure 6. Sliding flange installation

Rear (connector end) of the subsystem

VTrak J310s

Sliding plate

Screws (6 each side)

14

Chapter 2: Installation

Figure 7. Mounting rail installation

Rack front post

Rack back

Rail adjustment screw

Mounting Rail

Sliding plate

Rail attaching screw

Rail attaching screw

(not included)

(not included)

Inside of post

Inside of post

 