Prochem Triad Air Mover User Manual

Page 1
THRUSTER FAN UNIT
Operating Instructions (ENG)
MODEL: 115 V
1.004-035.0
86333800 - L 07/06/12
Read instructions before operating the machine.
Page 2
Machine Data Log / Overview
Warranty Registration
Thank you for purchasing a Prochem product. Warranty registration is quick and easy.
Your registration will allow us to serve you better over the lifetime of the product.
To register your product go to :
www.prochem.com/WarrantyRegistration.aspx
For customer assistance:
1-800-776-2436
2 86333800 TRIAD THRUSTER FAN
Page 3
Machine Data Log / Overview. . . . . . . . . . . . . . . . . .2
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . .3
How To Use This Manual . . . . . . . . . . . . . . . . . . . . .4
Safety
IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . .5
CONSIGNES IMPORTANTES DE SÉCURITÉ . . . .6
HAZARD INTENSITY LEVEL. . . . . . . . . . . . . . . . . .7
DEGRÉS DE RISQUES EN CAS DE DANGER . . .8
115V Grounding Instructions . . . . . . . . . . . . . . . . . .9
Safety Label Location . . . . . . . . . . . . . . . . . . . . . . .10
Operations
Technical Specifications . . . . . . . . . . . . . . . . . . . . .11
Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Bottom Vent Plate. . . . . . . . . . . . . . . . . . . . . . . . . .13
Identification Area (For Customers Use). . . . . . . . .13
How to Carry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Daisy Chaining Fans. . . . . . . . . . . . . . . . . . . . . . . .13
Cord Storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Carpet Floating . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Operating Positions. . . . . . . . . . . . . . . . . . . . . . . . .14
Ducting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Back Draft Prevention. . . . . . . . . . . . . . . . . . . . . . .17
Table of Contents
Maintenance
Service Components. . . . . . . . . . . . . . . . . . . . . . . .18
Stacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Cleaning Fan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Replacing Fan/Motor Assembly . . . . . . . . . . . . . . .20
Removing Electrical Console . . . . . . . . . . . . . . . . .20
Replacing GFCI . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Replacing Switch . . . . . . . . . . . . . . . . . . . . . . . . . .20
Replacing Power cord. . . . . . . . . . . . . . . . . . . . . . .21
Circuit Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Capacitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . .22
PARTS
Electrical Console . . . . . . . . . . . . . . . . . . . . . . . . . 24
Housing and Motor . . . . . . . . . . . . . . . . . . . . . . . . 26
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Suggested Spare Parts. . . . . . . . . . . . . . . . . . . . . 30
86333800 TRIAD THRUSTER FAN 3
Page 4
Model:
Date of Purchase:
Serial Number:
Dealer:
Address:
Phone Number:
Sales Representative:
How To Use This Manual
This manual contains the following sections:
How to Use This Manual
•Safety
Operations
Maintenance
•Parts List
The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts.
Parts may be ordered from authorized dealers. When placing an order for parts, the machine model and machine serial number are important. Refer to the MACHINE DATA box which is filled out during the installation of your machine. The MACHINE DATA box is located on the inside of the front cover of this manual.
The model and serial number of your machine is located on the bottom of the machine.
The SAFETY section contains important information regarding hazardous or unsafe practices of the machine. Levels of hazards are identified that could result in product damage, personal injury, or severe injury resulting in death.
The OPERAT IONS section is to familiarize the operator with the operation and function of the machine.
The MAINTENANCE section contains preventive main­tenance to keep the machine and its components in good working condition. They are listed in this general order:
Storage
Maintenance
Troubleshooting
The PARTS LIST section contains assembled parts illustrations and corresponding parts list. The parts lists include a number of columns of information:
REF – column refers to the reference number on the parts illustration.
PART NO. – column lists the part number for the part.
PRV NO. – reference number.
QTY – column lists the quantity of the part used in that area of the machine.
DESCRIPTION – column is a brief description of the part.
SERIAL NO. FROM – If this column has an (*) and a Reference number, see the SERIAL NUMBERS page in the back of your manual. If column has two asterisk (**), call manufacturer for serial number. The serial number indicates the first machine the part number is applicable to. The main illustration shows the most current design of the machine. When a boxed illustra­tion is shown, it displays the older design.
NOTES – column for information not noted by the other columns.
NOTE: If a service or option kit is installed on your machine, be sure to keep the KIT INSTRUCTIONS which came with the kit. It contains replacement parts numbers needed for ordering future parts.
The manual part number is located on the lower left corner of the front cover.
4 86333800 TRIAD THRUSTER FAN
Page 5
Safety
IMPORTANT SAFETY INSTRUCTIONS
When using this machine, basic precaution
must always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.
To reduce the risk of fire, electric shock, or injury:
Use only indoors. Do not use outdoors or expose to rain or water. Use only as described in this manual. Use only manufacturer's recommended components and attachments. Do not operate the machine with any openings blocked. Keep openings free of debris that may reduce airflow. Do not operate this machine near flammable fluids, dust or vapors. Maintenance and repairs must be done by qualified personnel. The machine shall only be operated by instructed and authorized persons. Do not handle the plug or machine with wet hands. Do not unplug machine by pulling on cord. To unplug, grasp the plug, not the cord. Do not use with damaged cord or plug. Do not pull or carry by cord, use cord as a handle, run over cord, close a door on cord , or pull cord around sharp
edges or corners. Connect to a properly grounded outlet. Connect only to an outlet provided with a ground fault circuit interrupting device (GFCI). Do not use this fan with any solid-state speed control device. Never service or clean the unit while plugged in. Do not operate without safety guards properly installed and secured.
READ AND SAVE THESE INSTRUCTIONS
86333800 TRIAD THRUSTER FAN 5
Page 6
Safety
CONSIGNES IMPORTANTES DE SÉCURITÉ
Lors de l'utilisation d'un appareil électrique, il faut toujours
observer des précautions élémentaires, qui comprennent parmi celles-ci:
LISEZ BIEN L'ENSEMBLE DES CONSIGNES AVANT D'UTILISER CET APPAREIL.
Pour réduire les risques d'incendie, d'électrocution ou de blessure:
Utilisez-le exclusivement dans des endroits fermés. Ne l'utilisez pas en plein air et ne le laissez pas sous la pluie. Utilisez-le exclusivement de la manière décrite dans ce manuel. Utilisez exclusivement les composants et les
fixations recommandés par le fabricant. Ne faites pas fonctionner l'appareil si des ouvertures sont bouchées. Dégagez des ouvertures tous débris
susceptibles d'entraver le passage de l'air. Ne faites pas fonctionner cet appareil à proximité de fluides, de poussières ou de vapeurs inflammables. Les travaux de maintenance et de réparation doivent absolument être effectués par du personnel qualifié. L'utilisation de l'appareil est exclusivement réservé à des personnes formées et autorisées. Ne manipulez pas la fiche ou l'appareil les mains mouillées. Ne débranchez pas l'appareil en tirant sur le cordon. Pour le débrancher, empoignez la fiche, non pas le cordon. N'utilisez pas l'appareil si le cordon ou la fiche est endommagé(e). Observez toutes les consignes figurant dans ce
manuel au sujet de la mise à la terre de l'appareil. Ne tirez pas sur le cordon, ne portez pas l'appareil par le cordon, n'utilisez pas le cordon comme poignée, ne
fermez pas une porte sur le cordon, ne tirez pas sur le cordon dans des angles ou des coins pointus. Raccordez l'appareil à une prise adéquatement reliée à la terre. Voir les Consignes de mise à la terre. Utilisez-le uniquement sur des réceptacles protégés GFCI. N'utilisez pas ce ventilateur avec quelconque dispositif de contrôle de la vitesse à l'état solide. Ne jamais entretenir ou nettoyer l'unité pendant qu'a branché sur. Ne pas fonctionner sans les gardes de sécurité convenablement installé et obtenu.
CONSERVEZ CES CONSIGNES
6 86333800 TRIAD THRUSTER FAN
Page 7
Safety
The following symbols are used throughout this guide as indicated in their descriptions:
HAZARD INTENSITY LEVEL
There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR SAFETY. The level of hazard intensity is determined by the following definitions:
WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death.
CAUTION - Hazards or unsafe practices which could result in min or personal in jury or pr oduct or pr operty damag e. FOR SAFETY: To Identify actions which must be followed for safe operation of equipment.
Report machine damage or faulty operation immediately. Do not use the machine if it is not in proper operating condition. Following is information that signals some potentially dangerous conditions to the operator or the equip­ment. Read this information carefully. Know when these conditions can exist. Locate all safety devices on the machine. Please take the necessary steps to train the machine operating personnel.
FOR SAFETY:
DO NOT OPERATE MACHINE: Unless Trained and Authorized. Unless Operation Guide is Read and understood. In Flammable or Explosive areas. In areas with possible falling objects.
WHEN SERVICING MACHINE: Avoid moving parts. Do not wear loose clot hing; jackets, shirt s, or sleeves when working on the machine. Use only manufacturer approved replacement parts
86333800 TRIAD THRUSTER FAN 7
Page 8
!
AVERTISSEMENT:
!
ATTENTION:
Safety
Les symboles ci-dessous sont utilisés à travers ce manuel comme illustré dans leurs descriptions:
DEGRÉS DE RISQUES EN CAS DE DANGER
Il existe trois degrés de risques identifiés par les termes signalétiques -AVERTISSEMENT et ATTENTION et POUR VOTRE SÉCURITÉ. Le degré de risque est défini de la manière suivante:
AVERTISSEMENT - Dangers ou méthodes dangereuses qui POURRAIENT provoquer de graves blessures ou
entraîner la mort.
ATTENTION - Dangers ou méthodes dangereuses qui pourraient provoquer des blessures légères ou une détérioration du produit ou des biens immobiliers.
POUR VOTRE SÉCURITÉ: ce signe permet d'identifier les mesures de précaution à prendre pour assurer un bon fonctionnement du matériel.
Rendre compte immédiatement d'une défaillance ou d'une détérioration de la machine. Ne pas utiliser la machine si celle-ci ne fonctionne pas correctement. Lire soigneusement les informatio ns ci-dessous signalant certains dangers potentiels pour l'opérateur de la machine. L'opérateur doit être absolument au courant de ces dangers potentiels. Localiser tous les dispositifs de sécurité sur la machine. Il est conseillé de prendre les mesures nécessaires pour former le personnel opérateur.
POUR VOTRE SÉCURITÉ:
NE PAS MANOEUVRER LA MACHINE: Lorsqu'on n'est pas expérimenté ou qualifié. Lorsque le guide d'utilisation n'est pas été lu ou compris. Dans des zones inflammables ou explosives. Dans des zones où des objets peuvent tomber.
LORS DE L'ENTRETIEN DE LA MACHINE: Éviter les parties amovibles. Ne pas porter de vêtements amples, t els que des vestes, des chemises ou des
vêtements avec manches lors de l'utilisation de la machine. Utiliser les pièces détachées Windsor homologuées.
8 86333800 TRIAD THRUSTER FAN
Page 9
1 15V Grounding Instructions
USING AN ADAPTOR
GROUNDING CONNECTION
Note: Adaptors are not allowed in Canada.
Outlet
Tab for Grounding
Outlet Box
FIGURE C
Grounded
FIGURE A
Adaptor
Screw
FIGURE B
Adaptor
Metal Screw
Grounded
Grounding Pin
!
AVERTISSEMENT:
ELECTRICAL: In the USA this machine operates on a standard 15
amp 1 15V, 60 hz, A.C. power circuit . The amp, hertz, and voltage are listed on the data label found on each machine. Using voltages above or below those indicated on the data label will cause serious damage to the motors.
EXTENSION CORDS: If an extension cord is used, the wire size must be at
least one size larger than the power cord on the machine, and must be limited to 50 feet (15.5m) in length.
GROUNDING INSTRUCTIONS: This appliance must be grounded. If it should malfunc-
tion or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordi­nances.
This appliance is for use on a nominal 120-volt circuit, and has a grounded plug that looks like the plug in "Fig. A". A temporary adaptor that looks like the adaptor in "Fig. C" may be used to connect this plug to a 2-pole receptacle as shown in "Fig. B", if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet (Fig. A) can be installed by a qualified electrician. The green colored rigid ear, lug, or the like extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adaptor is used, it must be held in place by a metal screw.
Safety
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Use only GFCI protected receptacles.
Le raccordement incorrect du conducteur de terre d'équipement peut entraîner des risques d'électro­cution. Vérifiez auprès d'un électricien qualifié ou d'un responsable de l'entretien si vous avez quelque doute que ce soit quant au ra ccordement à la terre de votre prise murale. Ne modifiez pas la fiche fournie avec l'appareil : si elle ne correspond pas à la prise murale, faites installer une prise adéquate par un électricien qualifié. Utilisez-le uniquement sur des réceptacles protégés GFCI.
86333800 TRIAD THRUSTER FAN 9
Page 10
Safety
Safety Label Location
This drawing indicates the safety label location on the machine. If at any time the label becomes illegible, promptly replace it.
Warning Label
8.633-474.0
10 86333800 TRIAD THRUSTER FAN
Page 11
Technical Specifications
Width
Height
Length
ITEM MEASURE
Height 12 In
Length 22.5 In
Width 18.5 In
Motor .25 HP
Cord 25’ X 14 Gauge / 3 Wire Safety Yellow
Weight w/Cord 22 Lbs.
Body Construction Rotationally Molded Polyethylene
Frame Construction Powder Coated Aluminum
Power Outlet GFCI Duplex
Electrical
Fan 1.48 Amps @ 110 / 120 VAC 60 Hz
GFCI Outlet 10.52 Amps (Max w/ fan on) @110 / 120 VAC 60 Z
Total Power 12Amps @ 110 / 120 VAC 60 Hz
Operations
SPECIAL NOTES:
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
The ambient sound pressure level was measured to be 66.9 dBA. This was a nearfield, broadband measurement taken in a typical industrial environment on a tile floor.
86333800 TRIAD THRUSTER FAN 11
Page 12
16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
17
19
18
15
Operations
Components
1. Power Cord
2. Quick Ducting Band
3. Intake Nozzle
4. Cord Storage Area
5. Back Legs
6. Side Legs
7. Fan Power Switch
8. Fan “On” Indicator Light
9. Console
10. Exhaust Nozzle
11. Identification Area (For Customer Use)
12. Carry Handle
13. GFCI Fault Reset Button
14. Power Indicator Light (Orange Fault)
15. Ducting Flanges
16. GFCI Duplex Outlet
17. Rubber Feet
18. Bottom Vent Plate
19. Motor/Fan Base Plate
12 86333800 TRIAD THRUSTER FAN
Page 13
Operations
!
AVERTISSEMENT:
!
AVERTISSEMENT:
Bottom Vent Plate
Rotate the disk to align the holes in the fan with the holes in the vent disk to allow air flow down to dry flooring directly under fan. For high pressure applica­tions which forces all the air out the exhaust nozzle, rotate the holes so they are misaligned, to close the vent plate.
Identification Area (For Customers Use)
This smooth area is for product numbering or identi­fying ownership, location, etc.
How to Carry
Use proper carrying techniques when moving fans. Lift and lower with legs while back is straight and upright.
Servez-vous des techniques de transport appro­priées lorsque vous déplacez des ventilateurs. Soulevez et abaissez avec les jambes tout en gardant le dos bien droit.
1. Disconnect all attachments and power cords.
2. Wrap the fans cord around intake nozzle.
3. Tilt fan on its back with exhaust outlet pointing up.
4. Carry by handle.
5. Place the fan back down on its back legs.
6. Position fan as desired.
Daisy Chaining Fans
The fan is equipped with a GFCI (Ground Fault Circuit Interrupt) duplex outlet. When the power cord of the fan is plugged into a power source, other fans or pieces of equipment can be plugged into fans power outlet. Of the 12 amps available, 1.6 is used by fan, leaving maximum of 10.4 total amps availa ble for other fans or equipment.
Do not plug devices requiring a total more than 12 Amps on circuit.
Ne branchez pas des appareils exigeants un total de plus de 12 AMPS sur le circuit.
Turn off all devices before unplugging from outlets. Fans power switch only controls fans motor and does not switch on and off the GFCI outlet.
Fans circuit breaker protects fan and power being supplied to GFCI outlet. If breaker pops remove some of the down stream load from circuit then reset.
Cord Storage
Fans power cord is best stored around neck of intake nozzle.
1. Turn off fan.
2. Disconnect any additional fans or machines plugged into fans auxiliary outlet and unplug fan from its power source.
3. Remove quick ducting band.
4. Working from fan to cord plug end, lay cord out straight, remove any twists as you go.
5. Make a 2” loop in cord near strain-relief then wrap cord snugly around neck of intake nozzle coiling from bottom up.
6. Allow cord to untwist as you coil cord around intake neck.
7. Secure cord end by attaching cords plug retaining clip to cord of the previous loop.
8. Stretch the quick-ducting band over cord end for added holding.
86333800 TRIAD THRUSTER FAN 13
Page 14
!
ATTENTION:
Operations
Carpet Floating
The fan can also be used in carpet floating applications.
1. Pull back carpet, place fan at one of corners.
2. Put fans exhaust nozzle under carpet pointing towards center while sitting flat on its feet.
3. Wrap quick-ducting band around int ake nozzle and corner of carpet. Be sure carpet does not cover fans air intake.
Operating Positions
This fan can be operated in almost any position or orientation.
The three main positions are; horizontal (sitting on it s feet), vertical (sitting on its back exhaust pointed up), and sideways (sitting on either left or right side). For any position, do not block air intake.
Horizontal position is used for blowing across floor surfaces.
Vertical position is used to direct airflow up to blow on to ceiling.
Side position is used to blow along a wall
Never allow anything to block intake airflow. Be careful of objects which could be drawn against intake. The fan must sit on a level surface. Always position and orient fan before turning on.
Ne permettez jamais à quoi que ce soit de bloquer l'entrée d'air. Faites attention aux objets qui pour­raient être attirés contre l'entrée d'a ir. Le ventilateur doit reposer sur une surface de niveau. Dirigez et orientez toujours le ventilateur avant de l'allumer.
14 86333800 TRIAD THRUSTER FAN
Page 15
Operations
!
ATTENTION:
Horizontal Operation
Place fan on its rubber feet with the int ake on top. Point fans exhaust in desired direction. Turn on fan.
Never allow anything to block intake airflow. Be careful of objects which could be drawn against intake. The fan must sit on a level surface. In vertical or side operation, to protect floor, add barrier beneath fans soft polyethylene body. On smooth slick floors the barrier will also keep fan in place during operation. Without enough traction, the fan could move from the force of air. Always position and orient fan before turning on.
Vertical Operation
Place fan on its back with the exhaust pointing straight up. Turn on fan.
Side Operation
To operate on its side, which is normally against a wall, point rubber feet toward wall, with intake vent away from wall and other possible obstructions. Turn on fan.
Ne permettez jamais à quoi que ce soit de bloquer l'entrée d'air. Faites attention aux objets qui pour­raient être attirés contre l'entrée d'air. Le ventilateur doit reposer sur une surface de niveau. Dans un fonctionnement vertical ou latéral, afin de protéger le plancher , ajoutez une barrière s ous le corps mou en polyéthylène des ventilateurs. Sur des planchers lisses et luisants, la barrière aidera également à maintenir le ventilateur en place lors du fonctionnement. Sans une traction suffis ante, le ventilateur pourrait se déplacer en raison de la force d'air. Dirigez et orientez toujours le ventila­teur avant de l'allumer.
86333800 TRIAD THRUSTER FAN 15
Page 16
!
AVERTISSEMENT:
!
AVERTISSEMENT:
Operations
Ducting
Switch off and unplug fan from its power source before connecting ducting. Also unplug any cords plugged into the auxiliary outlets on fan.
Arrêtez et débranchez le ventilateur de sa source d'énergie avant de relier la canalisation. Débran­chez également tous les cordons branchés aux sorties auxiliaires sur le ventilateur.
Be aware that ducting will move as it inflates or has air moving through it.
Prenez conscience que la canalisation se déplacera alors qu'elle se gonflera ou alors que l'air passera à travers.
Exhaust Ducting
NOTE: Vent plate is normally placed in closed position when using ducting.
1. Place quick-ducting band over lay-flat duct approximately 1 foot from end.
2. Slide ducting 3 or 4 inches over front exhaust nozzle, make sure it is even all around.
3. Secure in place by sliding quick-ducting band along ducting and over exhaust ducting flange.
4. Verify that ducting is sandwiched between fan exhaust nozzle and quick-ducting band and even all around making a good seal.
5. Position fan and ducting in desired orientation and location.
6. Plug fan into power source.
7. Turn off any additional fans or equipment and plug into fans onboard auxiliary outlets.
8. Switch fan on.
9. Observe ducting as air starts to flow through it, ducting may move around.
10. Switch on other equipment plugged into the auxiliary outlet.
16 86333800 TRIAD THRUSTER FAN
Page 17
Operations
Intake Ducting
1. Unwrap cord from cord storage area.
2. Place a quick-ducting band over ridged spiral duct about 1 foot from end.
3. Slide ducting 3 or 4 inches over top intake nozzle, make sure it is even all around.
4. Secure in place by sliding quick-ducting band along ducting and over the intake ducting flange.
5. Verify that ducting is sandwiched between fan intake nozzle and quick-ducting band and even all around making a good seal.
6. Position fan and ducting in desired orientation and location.
7. Plug fan into power source.
8. Turn off any additional fans or equipment and plug into fans onboard auxiliary outlets.
9. Switch fan on.
10. Observe ducting as air starts to flow through it, ducting may move around.
11. Switch on other equipment plugged into the auxiliary outlet.
Back Draft Prevention
Exhausting too much air from a space with Open Combustion Devices ( e.g. furnace, fireplace or water heater) can cause those devices to back draft. This can contaminate the space with potentially fatal gases.
Évacuer trop d'air d'un espace avec des app areils à combustion ouverte ( p ex., fournaise, foyer ou chauffe-eau) peut entraîner un refoulement de ces appareils. Cela peut contaminer l'espace avec des gaz potentiellement mortels.
Use the fan as a recirculating unit only. Exhausting no air from the space and thus causing no negative pressure or back drafting.
OR
Exhaust a very limited amount of air, wh ich does not cause back drafting.
OR
Direct one or more outlet ducts from the fan to the room with combustion devices. This will positively pressurize the room, thus preventing back drafting.
When exhausting air from a space, always check Combustion Devices with the fan running to guarantee that back draft prevention measures are working.
En évacuant l'air d'un espace, toujours vérifie r que le ventilateur des appareils à combustion ouverte est en marche pour garantir l'efficacité des mesures de prévention antirefoulement.
86333800 TRIAD THRUSTER FAN 17
Page 18
1
2
3
4
5
6
Maintenance
Service Components
1. Power Cord
2. Motor/Fan Assembly
3. GFCI Duplex Outlet
4. Console
5. Fan Power Switch
6. Circuit Breaker
18 86333800 TRIAD THRUSTER FAN
Page 19
Maintenance
!
AVERTISSEMENT:
!
AVERTISSEMENT:
Stacking
During storage or transporting, fans can be stacked to minimize required space. Always secure fans in place with appropriate strapping. Do not stack fans any more than 4 high.
Never operate fans while they are stacked. This could result in damage to the motors.
N'actionnez jamais les ventilateurs lorsqu'ils sont empilés puisque les prises d'entrée d'air seront recouvertes. Ce qui pourrait endommager les moteurs.
1. Stack fans by placing the first one with its feet flat on a level floor . The power cord sh ould be wrapped around intake nozzle in its standard cord storage position.
2. Nest the feet of second fan over the intake nozzle of first one.
3. Strap fans together, and to a stable, strong struc­ture, especially in a moving truck.
Cleaning Fan
The fan can be wiped down with a cleaning cloth.
Always unplug power and any other attached components before cleaning. Always keep liquids away from all electrical components.
Débranchez toujours la prise électrique et tous les autres composants fixes avant le nettoyage. Tenez toujours les substances liquides à bonne distance de tous les composants électriques.
NOTE: The fan is best cleaned after being disassembled. Never plug in or operate the fan in any state of disassembly.
1. Remove the motor/fan assembly from main housing by removing base plates 6 screws.
2. While lowering base plate motor assembly out of housing, detach the main harness electrical connector from fan motor.
3. Wipe fan blades, motor mounting plates and inside of housing.
Storing in Warehouse and in Delivery Truck
Fans can be stored flat on their feet, on their backs, or on their sides. Always store them inside away from weather, in an area not exposed to excessive heat or cold.
It is NOT recommended to stack fans vertically for long periods of time. To minimize the amount of shelf space required during storage, place fans on their sides.
Always secure stored fans, especially in a moving vehicle and or when stacked.
NOTE: Do not store upside down with their intake nozzle towards the floor or with the exhaust nozzle pointed towards the floor.
For further cleaning, remove electrical console:
4. Remove the 4 back and bottom console mounting screws from inside the housing.
5. Feed harness through holes in housing as it is removed. The main housing should now be free of any electrical components and can be safely cleaned with most cleaning chemicals. High pressure can also be used to clean housing now. Do not use high temperature air or liquids on plastic housing.
6. Finger guards are also bolted on, and can easily be removed for cleaning.
7. To reassemble, reverse the disassembly steps.
NOTE: Always inspect all parts for damage during disassembly and reassembly and have an authorized service center replace any damaged components with factory replacement parts.
86333800 TRIAD THRUSTER FAN 19
Page 20
!
AVERTISSEMENT:
Maintenance
Replacing GFCI
Always disconnect all auxiliary power cords and accessories from fan before servicing. Always disconnect fan from all power sources. Never run or operate fan without all components in place especially protective covers and grills.
Débranchez toujours tous les cordons électriques et les accessoires auxiliaires du ventilateur avant l'entretien. Débranchez toujours le ventilateur de toutes les sources d'électricité. Ne faites jamais fonctionner ou n'actionnez jamais le ventilateur sans tous ses composants et plus particulière­ment, les couvercles protecteurs et les grilles.
Replacing Fan/Motor Assembly
1. Remove the motor/fan assembly from main housing by removing base plates 6 screws.
2. While lowering base plate motor assembly out of housing, detach the main harness electrical connector from fan motor.
3. Rotate bottom vent plate and align access holes. Insert tool through holes and remove 4 mounting screws from fan/motor assembly.
NOTE: The motor/fan is replaced as a matched unit, never disassemble the fan from motor .
4. Reverse steps to reassemble.
1. Remove electrical console from main housing.
2. Remove screws bolting two halves of the console together. Carefully separate the two halves taking note of wire placement and routing.
3. Swing top half of console away from bottom far enough to access mounting screws for the GFCI, and remove.
4. Remove GFCI from housing and detach electrical wires, noting all wire connections for reassembly. Also consult wiring diagram during reassembly.
5. The original GFCI has one corner tab removed to clear housing. Remove this same tab from new GFCI and assemble in same orientation.
6. Torque the GFCI screws to 15 in-lbs.
Replacing Switch
1. Remove electrical console from main housing
2. Remove the screws bolting the two halves of the console together. Carefully separate the two halves taking note the wire placement and rou ting.
3. Swing top half of console away from bottom far enough to access back of switch.
4. Press in mounting ears on each side of switch and slide body out top of housing.
5. Note the wire attachment locations and colors/ numbers and orientation of switch for reassembly.
Removing Electrical Console
1. To remove the console assembly first remove the fan/motor base plate assembly.
2. To remove electrical console from main housing, remove 4 screws from inside the housing that mount to back and bottom of console.
3. Feed harness through holes in housing as it is removed.
4. Reverse steps to reassemble.
20 86333800 TRIAD THRUSTER FAN
6. Reverse steps while consulting wiring diagram to reassemble.
Page 21
Maintenance
Replacing Power cord
1. Remove electrical console from main housing
2. Remove screws securing console halves together . Carefully separate two halves noting wire placement and routing.
3. Swing console halves open enough to access back side of power cord.
4. Remove mounting nut from the trumpet shaped strain relief. Disconnect wires noting location and connections.
5. Reverse steps while consulting wiring diagram to reassemble.
Circuit Breaker
1. Remove electrical console from main housing
2. Remove screws securing console halves together . Carefully separate two halves noting wire placement and routing.
3. Swing console halves open enough to access back side of breaker.
Capacitor
1. Remove electrical console from main housing
2. Remove screws securing console halves together. Carefully separate two halves noting wire placement and routing.
3. Swing console halves open enough to access capacitor, remove.
4. Before disconnecting capacitor, note wire connec­tions, locations and color / numbers for reas­sembly. it is important that it is reconnected properly. Disconnect wires from capacitor.
5. Reverse steps while consulting wiring diagram to reassemble.
4. Before disconnecting circuit breaker note line and load labeling, it is important that it is reconnected properly. Disconnect wires from breaker.
5. Remove clear rubber boot on outside of housing and slide breaker through hole in console.
6. Reverse steps while consulting wiring diagram to reassemble.
86333800 TRIAD THRUSTER FAN 21
Page 22
Maintenance
Troubleshooting
PROBLEM CAUSE SOLUTION
No Power, Nothing Runs
Fan Runs but poor air flow
Fan will not run, but GFCI outlet has power
GFCI does not have power, but fan runs
Light on switch does not work but fan runs
Power cord not plugged in Plug in cord Circuit breaker tripped on fan console Find source of fault, correct, reset breaker GFCI tripped on fan console Find source of fault, correct, reset GFCI Circuit breaker tripped in building Reset Breaker Loose wiring connectors Check wiring, ensure good connection Faulty circuit Breaker Replace Breaker Faulty GFCI Replace GFCI Intake nozzle is blocked Remove blockage Exhaust nozzle is blocked Remove blockage Loose wiring connectors Check wiring, ensure good connection Faulty switch Replace switch Faulty motor capacitor Replace Capacitor Faulty fan motor Replace motor / impeller assembly Loose wiring connectors Check wiring, ensure good connection Faulty GFCI Replace GFCI Loose wiring connectors Check wiring, ensure good connection Faulty switch Replace switch
22 86333800 TRIAD THRUSTER FAN
Page 23
PARTS
86333800 TRIAD THRUSTER FAN
Page 24
Electrical Console
17
A
A Torque 15 in-lbs
10
11
15
2
12
16
12
13
1
9
8
7
6
5
4
3
10
7
7
14
24 86333800 TRIAD THRUSTER FAN
Page 25
Electrical Console
REF PART NO. PRV NO. QTY DESCRIPTION
1 98024510 - 1 SWITCH, LIGHTED 2-POS ROCKER 2 86172820 - 1 SCR,M5 X 20 ,PHMS,ISO7045, SST 3 86331680 - 2 NUT, M5 HEX SS 4 86329780 - 1 CAPACITOR, 15MICROFARAD 5 86329760 - 1 CONSOLE, ELECT, LOWER 6 86329750 - 1 CONSOLE, ELECT, TOP 7 86327510 - 13 SCR, KA50X16, PT OHS, WN1412, A2 SS 8 86327360 - 1 GFCI, NEMA 5-15, 15A 125V
9 86327350 - 1 BREAKER, 12A, 250VAC 10 86013850 - 5 WASHER, M6, FNDR, ISO7039,SS 11 86012970 - 2 WASHER, M5, FNDR, ISO7039,SS 12 86024750 94028 4 NUT, M5 HEX NYLOCK, SS 13 86010640 87016 4 WASHER, #10 EXT STAR SS 14 98022090 - 1 MOUNTING SQUARES, DBL BACKED TAPE 15 86335780 - 1 CORD, SET 16 86002010 14942 1 BOOT, 3/8 CIRCUIT BREAKER 17 86338170 - 2 SCR, M5 X 35 PPHMS SS
SERIAL NO.
FROM
NOTES
86333800 TRIAD THRUSTER FAN 25
Page 26
Housing and Motor
3
24
20
25
14
13
7
2
4
6
18
17
16
10
20
6
8
3
21
9
1
12
6
11
9
5
6
20
11
19
12
12
9
23
22
15
26 86333800 TRIAD THRUSTER FAN
Page 27
Housing and Motor
REF PART NO. PRV NO. QTY DESCRIPTION
1 86198450 20005 1 CLAMP, 5/16 NYLON
2 86218420 36212 1 GUARD, FRONT, AB
3 86172630 57314 2 NUT, M4, LK, ISO7040,SST
4 86335770 - 2 NUT, M6, SS
5 86217910 66352 4 FOOT, BLOWER
6 86274340 70179 15 SCR, M6 X 16 PH
7 86275800 70546 2 SCR, 8 X 3/4 PFHT/S BLK ZINC
8 86172860 70897 1 SCR, M4X12, PPHMS, ISO7045,SST
9 86173310 87499 11
10 86223930 739996 4 SCR, M6 X 15 HHCS SS 11 86013850 - 8 WASHER, M6, FNDR, ISO7039,SS 12 86172650 57508 7 NUT, M6, LK, ISO7040, SST 13 86322680 - 1 FINGER GUARD, INTAKE, HPAM
14 86327510 - 4
15 89198520 - 1 HOUSING, AIR MOVER, TRIM (BLUE) 16 86329800 - 1 MOTOR MOUNT, A.M. 17 86329830 - 1 PLATE, DIFFUSER
18 86342290 - * SET, 50 DUCT RETAINERS
19 89186580 - 1
20 86010640 - 3 WASHER #10 LOCK EXT STAR SS 21 86332750 - 1 MOTOR ASM, 115VAC, AIR MOVER 22 86332330 - 1 LABEL, TRIAD, RIGHT 23 86332340 - 1 LABEL, TRIAD, LEFT 24 86002370 20035 1 CLAMP, 7/16 DIA NYLON UL 25 86172890 - 1 SCR, M4 X 16 PPHMS ISO7045,SST
WASHER,SPRING LK,6MM,DIN127B,SS
SCR, KA50X16, PT OHS, WN1412, A2 SS
BRACKET MOUNTING PAINTED, AL AIR MOVER
SERIAL NO.
FROM
NOTES
SOLD IN SETS
OF 50 ONLY
86333800 TRIAD THRUSTER FAN 27
Page 28
Wiring
/
5/GRN 1/BLK 9/WHT
2/BLK
3/BLK
4/WHT
1/BLK
4C/WHT
4A/WHT
8B/BLK
7/BLU
8C/BLK
6/GRN
5/GRN
8/BLK
GFCI OUTLET
CIRCUIT BREAKER
120VAC CORD
LIGHTED SWITCH
MOTOR CAPACITOR
4 - PIN
FAN MOTOR
CONNECTOR
N
H
LINE
LOAD
LOAD
LOAD
LINE
LINE
7
2
3
GND
1
28 86333800 TRIAD THRUSTER FAN
Page 29
Wiring
REF PART NO. PRV NO. QTY DESCRIPTION
1 86330890 - 1 HARNESS, AIR MOVER
SERIAL NO.
FROM
NOTES
86333800 TRIAD THRUSTER FAN 29
Page 30
Suggested Spare Parts
PART NO. PRV NO. QTY DESCRIPTION
98024510 - 1 SWITCH, LIGHTED 2-POS ROCKER 86329780 - 1 CAPACITOR, 15MICROFARAD 86327360 - 1 GFCI, NEMA 5-15, 15A 125V 86335780 - 1 CORD SET 86002010 14942 1 BOOT, 3/8 CIRCUIT BREAKER 86217910 66352 4 FOOT, BLOWER
86311900 - 1 CLIP, X-MAS TREE, 1/4", BLACK 86342290 - * SET, 50 DUCT RETAINERS 86332750 - 1 MOTOR ASM, 115VAC, AIR MOVER
SERIAL NO.
FROM
NOTES
SOLD IN SETS
OF 50
30 86333800 TRIAD THRUSTER FAN
Loading...