Safety & Precautions
WARNING: Safety precaution measures must be practiced at all times during the installation of this product. Use proper safety gear and tools for the
installations
rocedure to prevent personal injury or damage to the plasma displays or plasma mounts.
The wall or ceiling structure must be capable of supporting at least five (5) times the weight of plasma display. If not, the wall or ceiling must be reinforced. Proper installation procedure by qualified personnel as outlined in the installations instructions must be adhered to. Failure to do so could result in serious
The entire installation instructions should be fully read and understood, including all of the safety symbols and safety precautions, before beginning installation. The installation instructions should be read, understood and followed to prevent personal injury or property damage. Keep these installation instructions in an easily accessible location for future reference.
ersonal injur
Indicates that the power plug is to be disconnected from the power outlet.
Contact Premier Mounts for any questions
Safety precautions must be taken at all times.
Warning and caution in general
Installation and removal of plasma panels and brackets should be performed only by qualified personnel and should conform to all applicable codes.
Never place any objects on top of, or hang any objects from the plasma panel.
Your plasma panel is heavy! Do not have your panel mounted in an area where it is likely to be struck by another object or accidentally lifted from its mount.
Do not place anything underneath your plasma panel.
Keep the installation manual and user manuals in a safe place so that you can easily refer to them.
The wall must be capable of supporting a weight of at least 500 pounds. If the wall cannot support a weight of 500 pounds it must be reinforced. Failure to properly install the PSM-V501F plasma panel could result in serious personal injury.
Proper ventilation is required for the PDP-501MX plasma panel. Only Pioneer approved wall brackets should be used to mount the panel to ensure proper ventilation
- 3 -
Mount Diagrams
TILT BACK PLATE
PART#:
PSB-TBP MATERIAL: 12 (GA) CRS COLOR: Black powder coat
A. Lag bolt access slot. B. Mounting points (4.5") used on installations other than wall mounting. C. Access hole for power or cables. D. Mounting points for additional security screws.
MOUNTING BRACKET
PART#:
Mounting bracket MATERIAL: 12 (GA) P & O COLOR: Black Powder coat
1.125
18.500
8.000
8.000
5.000
4.500
b
1.000
1.750
3.250
1.250
19.771
16.000
5.460
2.865
4.500
5.460
16.000
e
F
3.500
A
d
c
- 4 -
g
Parts List
HARDWARE LIST
QTY SIZE DESCRIPTION
6 5/16” Dia Lag bolts 1 Mounting bracket 1 PSB-TBP tilt back plate 2 M6 x 12 (mm) Phillip security
screws
1 Installations instructions 6 M8 x 20 Phillip screws Mount hardware
Used for additional security on
tilt mounts, mobile carts, floor
stands and ceiling mounts
TOOLS NEEDED
o Phillips screwdriver o Drill gun o Soft material or a blanket o Pencil o ¼" drill bit o Level o Measuring tape o Wrench with a 1/2" socket o Stud finder
CEILING ADAPTERS (OPTIONAL)
o PCA-1 – 4.5" Ceiling adapter mates directly to the PSB-TBP tilt back plate
o PSA-1 – Height adjustable ceiling adapter adjustable range 24" to 46"
Ceilin
PCA-1
adapter
PSA-1
Height adjustable
ceiling adapter
- 5 -
play
play
p
play
p
Installing the mounting bracket
WARNING :
result in serious personal injury and possible damage to the plasma display.
Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to. Failure to do so could
Step 1
CAUTION
Invert the plasma display and set it on a flat and soft material such as (blankets, foam, cloth etc.) to prevent any damage to the plasma display. See fig 1.
: The plasma displays are fragile and heavy. At least two (2) qualified personnel are strongly recommended for the installation of this product.
Top of the plasma
dis
Inverted plasma
dis
Soft and flat surface blankets, foam, cloth
etc.
Bottom of the
lasma display
Step 2
Locate the mounting points found on the back of the plasma display, align the mounting holes from the mounting bracket to the holes on the plasma display. Arrow found on the mount must always be pointing to the top of the plasma display before securing it to the plasma display. Loosely install the six (6) M8 x 20 Phillip screws to the plasma then secure the screws with a Phillips screwdriver CAUTION WARNING: Do not use a drill gun to secure the screws to the plasma display. A Phillips head screwdriver is preferred.
: Do not over tighten the M8 x 20 Phillips screws. See fig 2.
Tilt back
late
Mounting hardware
(6) M8 x 20 Phillip
screws
Inverted plasma
dis
- 6 -
A
Installing the mounts
Step 3
Select the area where the plasma will be installed and make sure it can support the weight standards (see warning on page 3). Locate the 16" wood stud centers behind the wall using a (commercially available) stud finder and mark the center of the studs when found. Set the mounting bracket to the wall and mark the desired height by marking the center of the
tilt back plate.
See fig 3
Wall structure
Desired height
marking
Tilt back plate
16"
Stud centers
marking
djusting the
mount
CENTER
Wood studs behind
the wall structure
VIEWING
HEIGHT
floor floor
OF
- 7 -
g
To determine the desired viewing height, use the center slot opening in the wall mount as a center reference for the plasma television when mounted. Once the height is determined, use the bubble level to insure that the bracket is level. Next, using a pencil, mark the six (6) lag bolt slot openings on the mounting bracket. Before continuing, confirm the marks are located on the center of the studs. Drill 1/4" pilot holes on the six (6) markings on the wall. Raise the tilt back plate and have someone hold it in place (arrow side away from the wall and pointing up). Put the lag bolt through the flat washers. Screw the lag bolt through the upper left slot opening into the 1/4" pilot hole. Confirm that the wall mount is still leveled and then screw a lag bolt to the upper right side slot opening into the 1/4" pilot hole. Then install the remaining four lag bolts tightly into the wall studs in the lower left and right slot openings on the wall mount. Make any lateral positioning if any then secure the lag bolts. See fig 4.
Note: Pre drill before the securing the
5/16" la
bolts.
Caution: Do not over tighten the 5/16" lag bolts
Flat washers
5/16" Lag bolts
Marking on wall
Tilt back plate
Drill gun with a 1/4"
drill bit
Center of
viewing marks
Access holes
Wood studs behind
the wall structure
Wall structure
floor
floor
Electrical
Step 4
All electrical wiring components should be installed at this time to ensure that the plasma display has enough power sources.
- 8 -
A
Securing the mount
Step 5 Warning: The plasma display is heavy and 2 people are needed to lift and install it. Failure to do so could result in serious personal injury.
Before placing the plasma on the wall recheck all hardware for proper tightness and security. Before installing, become familiar with the way the plasma mount attaches to the wall mount. Align the four (4) tab openings to the four (4) receiving tabs on the tilt back plate. When all four (4) the tabs are aligned slide the plasma down, right and down again to lock the mounts together. Make sure all (4) tab openings are interlocked with the receiving tabs before letting go of the plasma. See fig 5.
Caution: The plasma display is heavy and 2 people are needed to lift and
install it. Failure to do so could result in serious personal injury.
Caution: All four (4) receiving tab openings from the mounting bracket must be locked to the tabs found on the tilt back plate before letting go of the plasma display. See the diagram on the left to see the interlocked tab.
Locked tab
Tilt back plate
Wall structure
Mounting
bracket
(4) Tab
openings
lign all four (4) tab
openings to the tilt
back plate receiving
tabs and push the
plasma as shown on
arrows to lock in place
Plasma display
(4) Securing
tabs
Plasma display
Wall structure
floor floor
Additional security
Step 6
For additional security gradually tilt the bracket forward using a Phillips screwdriver. Secure the two (2) M6 x 12 (mm) Phillips screws (screws) see fig 6. Do not over tighten the screws. Position the bracket to the desired angle. See fig 6.
- 9 -
Loading...