Prastel UNIK2E230 SK Manual

0 (0)

ISUNIK2E230v2_GB_10_12.doc

ELECTRONIC CONTROL PANEL

FOR TWO 230VAC MOTORS

UNIK2E230 _ V2

(COMPLETE)

UNIK2E230SK _ V2

( W I T H OUT B OX AN D T R ANSF ORM E R)

BOX IP 54

TECHNICAL INSTALLATION MANUAL

FOR AUTOMATIC GATES

WARNING!

Before installing, thoroughly read this manual that is an integral part of this Kit. Prastel S.p.A. declines any responsibility in the event current standards in the country of installation are not complied with

The symbol CE conforms with European Directive R&TTE 99/05CE

UNIK2E230 V2

ENGLISH

ISUNIK2E230v2_GB_10_12.doc

1.

INTRODUCTION ..........................................................................................

 

3

2.

MAIN FEATURES ........................................................................................

 

3

3.

TECHNICAL SPECIFICATIONS ..................................................................

 

3

4.

CONNECTION AND SET UP OF THE CONTROL UNIT .............................

4

 

4.1

GENERAL DIAGRAM OF SETTINGS AND CONNECTIONS ..................................

5

 

4.2

SIMPLIFIED LEARNING PROCEDURE (also see pages 8-10) ..............................

6

 

4.3

PROFESSIONAL LEARNING PROCEDURE (see also pages 8-10)......................

7

5.

CONTROL UNIT OPERATING LOGIC (ANALYTIC EXAM)........................

8

 

5.1

PROGRAMMING AND CANCELLATION OF THE REMOTE CONTROLS .............

8

 

5.2

OPERATION OF THE SAFETY DEVICES ...............................................................

 

8

 

5.3

TRIMMER “FOR”- MOTOR SPEED ........................

................................................. 9

 

5.4

TRIMMER “DEL”- DELAY BETWEEN MOTORS ...............

..................................... 9

 

5.5

TRIMMER “PAU” - “OPENING AND CLOSING” OPERATING MOD E ..................

9

 

5.6

“PEDESTRIAN OPENING” FUNCTION .....................

............................................ 11

 

5.7

TRIMMER “OBS” - “OBSTACLE SENSITIVITY” DETECTION.. ........................... 11

 

5.8

FLASHING LIGHT ..................................................................................................

 

11

 

5.9

GATE OPEN WARNING LIGHT .............................................................................

 

11

 

5.10

SLOW-DOWN .........................................................................................................

 

11

 

5.11

ELECTRIC LOCK ...................................................................................................

 

12

 

5.12

COURTESY LIGHT.................................................................................................

 

12

 

5.13

LOGICAL STOP (STP INPUT)................................................................................

 

12

 

5.14

CONTROL UNIT MEMORY FAULT........................................................................

 

12

6.

SIGNALLING LED .....................................................................................

 

12

7.

PROGRAMMING THROUGH GTSYSTEM ................................................

 

13

8.

ACCESSORIES ABSORPTION CHECK INFORMATION .........................

13

9.

TROUBLESHOOTING ...............................................................................

 

14

 

SAFETY WARNINGS FOR INSTALLATION AND USE ...................................................

 

15

2

UNIK2E230 V2

ENGLISH

ISUNIK2E230v2_GB_10_12.doc

1. INTRODUCTION

UNIK2E230 is a universal self-learning control unit especially designed for the automatic control of 230VAC powered, 1 or 2 motor driven accesses. It is fitted with an innovative self-learning procedure allowing rapid installation and four trimmers for fine adjustment of the main parameters; force, pause time, obstacle detection sensitivity and out of phase closing when two motors are used.

The following are available:

-simplified programming, thanks to which the unit automatically performs a learning operation to acquire running time and determine slow-down setting at 85% of opening and closing runs;

-A professional programming in which the installer can determine the instant in which the gate starts to slow-down, the enabling of the pedestrian opening via radio, the safety device trigger mode.

2. MAIN FEATURES

Management and control of 230VAC (max 400W) powered, 1 or 2 motor-driven automated accesses

Motors closing offset adjustable from 0 to 15 seconds using trimmers

Opening motors delay settable at 0 or 3 seconds

Double limit switch input open close

Motor force (speed) adjustable from 50-100%.using a trimmer.

Customisable partial opening (for pedestrian transit)

0 to 60” stand-by time adjustment via trimmer.

0.1 to 3.0” obstacle detection triggering time adjustment via trimmer.

Initial settings using dip-switches

Signalling LEDs (8)

Expansion for electric lock 12V 15W max (optional board ELU, with optional relay)

Expansion for courtesy light (optional board LCU)

Built-in 433MHz rolling-code receiver with 180 memorisable codes

Built-in flashing logic management

Flash microprocessor re-programmable on-board via serial interface.

Programming and control of the control unit using a portable terminal GTSYSTEM (optional)

Built to European reference Directive Standards (R&TTE 99/05/CE)

DECLARATION OF CONFORMITY

Prastel S.p.A. declares that UNIK2E230 IS IN ACCORDANCE with the 99/05/EC (R&TTE) direcitve

The complete declaration of conformity is available in Prastel or to the internet address www.prastel.it

3. TECHNICAL SPECIFICATIONS

Transformer power supply:

primary230 / secondary 18V 20VA / secondary12V 20VA

Control unit power:

230VAC

Motor output:

2 x 400W

Max current peak of motor:

Max 8 Ampere

Accessories power:

24 VDC - 500 mA protected by fuse (see info page 13)

Environmental operating temperature :

-20°C / + 55 °C

Programming parameters:

memorised in EEPROM

Functions handler:

microprocessor with watch-dog

BOX IP rating:

IP54

3

UNIK2E230 V2

ENGLISH

ISUNIK2E230v2_GB_10_12.doc

4.CONNECTION AND SET UP OF THE CONTROL UNIT

a)Before installing the UNIK2E230 control unit, read the “General safety warnings and notes” (page 15).

b)Mount a differential thermo-magnetic circuit breaker 6A (IC=30mA) on the mains supply as specified in the current reference standards (IC = differential current).

c)* Fix the box using the special fixing holes.

d)* Place the supplied cable-ways and insert the cables keeping the power and supply cables separate from each other.

e)Connect the motors to the terminal blocks “MOT1” e “MOT2”; if only one motor is used connect it to the terminal blocks “MOT1”.

f)Connect the external accessories making sure that the total of the average absorption of all the connected accessories is less than the maximum current available (see info page 13).

g)ATTENTION: Connect the limit switches if present, otherwise do not bridge inputs FC1, FC2, FO1, and FO2 in the terminal board.

h)ATTENTION: To avoid noisy or irregular operating when the control panel is used with hydraulic operators, the following is recommended:

set the Force to 100% (“FOR” trimmer completely clockwise).

do not use the slow-down (carry out the professional learning procedure).

do not use the obstacle detection (trimmer OBS to MAX),

i)During the learning with no electric limit switches present and with the obstacle detection disabled (e.g. with hydraulic operators), or else with no mechanical STOP (strike plate) present, to define the manoeuvre times:

Press pushbutton 1 of the remote control or pushbutton P1/SET to stop the gate in the desired position.

Press pushbutton 2 of the remote control or pushbutton P2/SET to stop the gate in the desired position.

j)Check the correct connection and operation of all the accessories connected to the terminal board.

NOTE:

* When the control panel is mounted directly onto the operator with the special control panel-holder, these two points are not relevant.

INITIAL FACTORY SETTINGS

If there is no programming, the control unit will operate as follows:

Step by step mode with automatic closing disabled

No slow-down

Closing safety present

No opening safety

Obstacle detection trigger time (OBS) 1 second

3 second opening and closing time of the motors

Pushbutton 1 of transmitters enabled

Safety test disabled

Kick-back disabled

4