pSeries NA
Revision 06/04
8609 Six Forks Road
Raleigh, NC 27615 U.S.A.
Toll: 1-800-925-4426
www.oem.powerware.com/ibm-ups
CANADA
Ontario: 416.798.0112
EUROPE/MIDDLE EAST/AFRICA
Denmark: 45.3677.7910
Finland: 358.9.452.661
France: 33.1.60.12.77.23
Germany: 49.7841.6660
Italy: 39.02.66.04.05.40
Norway: 47.23.03.65.50
Sweden: 46.8.598.940.00
United Kingdom: 44.1753.608.700
ASIA PACIFIC
Australia/NZ: 612.9878.5000
China: 86.21.6350.0606
HK/Korea/Taiwan: 852.2745.6682
India: 91.11.2649.9414 to 18
Singapore/SEA: 65.6829.8888
LATIN AMERICA
Argentina: 5411.4343.6323
Brazil: 55.11.3616.8500
México: 5255.9171.7777
Powerware
Model Selection Guide
Input Output Dimensions Unit
Power Out Voltage Voltage Input Output Jumper H x W X D weight
IBM FC Model (VA/Watts) (Vac) (Vac) Connection Connections Cords (mm) (kg)
9910-P07 PW5115 750/500 120 120 5-15P (4) 5-15R - 193 x 150 x 335 12.4
9910-P10 PW9125 1000/700 120 120 5-15P (6) 5-15R (3) IEC-320-C13 to 5-15P 89 x 432 x 493 15
9910-P15 PW9125 1500/1050 120 120 5-15P (6) 5-15R3 (3) IEC-320-C13 to 5-15P 89 x 432 x 493 23
9910-P181PW5125 1500/1340 230 230 IEC-320-C14 (6) IEC-320-C13 (2) IEC-320-C13 to IEC-320-C14 89 x 432 x 493 23
9910-P22 PW5125 2200/1600 230 230 5-20P (9) IEC-320-C13 - 250 x 205 x 493 31
9910-P30 PW9125 3000/2100 208-240 208-240 L6-20P (4) IEC-320-C13, (4) IEC-320-C13 to IEC-320-C14, 89 x 432 x 601 37
& 120 & 120 (1) IEC-320-C19 (1) IEC-320-C19 to IEC-320-C20
2
9910-P30 PW9125 3000/2100 208-240 208-240 (2) 5-15R, (4) 6-15/6-20R - P30: 89 x 432 x 601 37
& FC 6570 & 120 & 120 (2) L6-15R
9910-P33
3
PW5125 3000/2700 208-2404208-240
5
(9) IEC-320-C13, (3) IEC-320-C13 to IEC-320-C14 89 x 445 x 610 37
(1) IEC-320-C19
6
9910-P643PW9125 6000/4200 208-240 208-240 L6-30P or (1) L6-30R (uses IBM - 219 x 432 x 636 93
RS 3720 FC 2970 to power 5160 PDU)
9910-P64
3
& PW9125 6000/4200 208-240 208-240 (2) 5-15R, (4) 6-15/6-20R - P64: 219 x 432 x 636 141
6571 & 120 & 120 (2) L6-15R, (1) L6-30R - 6571: 1334 x 432 x 629
1. Can support a maximum of 2 rack devices. 2. Power cords are contained in Power Cord Kit box, IBM FC 9830, IBM PN 38P9306. 3. Can support a maximum of 1 Rack PDB. 4. User-selectable for 200, 208, 220, 230,
240 Vac. 5. Output will be the same as the selected input. 6. IEC-320-C19 receptacles can power Rack PDBs when using IBM PN 53P1968, IEC-320-C20 to IEC-309 CEE17, 2-pole, 3-wire, 32A receptacle power cord, 1.8
meters long. 7. Consists of two Power Cord Kits (IBM FC 9830, IBM PN 38P9306).
Input (Mains) Power Cord Options
IBM Feature Code IBM Part Number Plug Type / Description Used with Supplied by
9800, 9824, 9852, 1420 11F0113 12 / NEMA L6-30P P33, P64 IBM
9862, 9986, 1421 11F0114 12 / NEMA L6-30P P33, P64 IBM
9801, 9864, 1423 46F4594 40 / R&S 3750 P33, P64 IBM
9865, 9987, 1422 46F4593 40 / R&S 3750 P33, P64 IBM
9860 14F1553 11 / NEMA L6-20P P30 IBM
9861 07H0095 11 / NEMA L6-20P P30 IBM
2971 38P9304 46 / IEC309 (P+N+G) 32A P64 Powerware
9866 14F1554 18 / CEE7 VII P30 IBM
9867 14F1557 22 / SABS 164 P30 IBM
9868 14F1560 25 / CEI 23-16 P30 IBM
9871 14F1555 46 / IEC309 (P+N+G) 16A P30 IBM
9872 14F1561 32 / SII 32-1971 P30 IBM
9874 14F1559 54 / SAA-AS 3112 P30 IBM
9875 36L8885 64 / IEC 60083-A5 P30 IBM
1424 31F4466 46 / IEC 309 (P+N+G) 32A P64 IBM
1425 87G6067 KP / KP P64 IBM
1426 11F0106 PDL / PDL P64 IBM
1427 11F0107 PDL / PDL-NZ P64 IBM
Reference Input
(Mains) Power
Cord Options
table below
To view power (mains) installation diagrams, go to www.oem.powerware.com/ibm-ups/nemadiagm.pdf