PolyScience Histology Bath, Histology Bath HBATH-60 Operator's Manual

Operator’s Manual
Histology Bath
110-827
09.12.11
Table of Contents
Introduction............................................................................................................................................. 2
General Safety Information................................................................................................................................ 2
Safety Recommendations................................................................................................................................... 3
Regulatory Compliance & Testing..................................................................................................................... 3
Unpacking Your Histology Bath ........................................................................................................................4
Contents .................................................................................................................................................................4
Components & Controls......................................................................................................................... 5
Installation .............................................................................................................................................. 6
General Site Requirements ................................................................................................................................ 6
Adding Liquid to the Reservoir.......................................................................................................................... 6
Electrical Power....................................................................................................................................................6
Normal Operation ....................................................................................................................................7
Routine Maintenance & Troubleshooting ............................................................................................ 8
Draining the Reservoir ........................................................................................................................................8
Cleaning the Bath ................................................................................................................................................. 8
Air Vents................................................................................................................................................................. 8
Air Filter .................................................................................................................................................................8
Troubleshooting Chart......................................................................................................................................... 9
Technical Information ............................................................................................................................ 9
Performance Specifications ............................................................................................................................... 9
Replacement Parts................................................................................................................................ 10
Equipment Disposal (WEEE Directive) ................................................................................................ 10
Service and Technical Support ............................................................................................................ 10
Warranty.................................................................................................................................................. 11
110-827 1
Introduction
Thank you for choosing this Histology Bath. Its low working temperature (-60°C / -76°F) freezes samples quickly, preventing microscopic ice crystals from developing and samples from distorting. It is ideal for fast-freezing tissues for enzyme studies. The Histology Bath is not a controlled cooling source; it is designed to run at maximum cooling.
Standard features include:
Continuous cooling to -60°C / -76°F
1.9 liter stainless steel reservoir and reservoir cover
Immersion basket and chuck holder
Front-mounted reservoir drain
DuraTop™ insulating top deck
General Safety Information
When installed, operated, and maintained according to the directions in this manual and common safety procedures, your Histology Bath should provide safe operation. Please ensure that all individuals involved in the installation, operation, or maintenance of this Histology Bath read this manual thoroughly prior to working with the unit.
This symbol marks chapters and sections of this instruction manual that are particularly relevant to safety. When attached to the unit, this symbol draws attention to the relevant section of the instruction manual.
This symbol indicates that hazardous voltages may be present.
This symbol marks information that is particularly important.
This symbol indicates alternating current.
This symbol on the Power Switch / Circuit Breaker indicates that it places the unit into a fully powered state.
This symbol on the Power Switch / Circuit Breaker indicates that it disconnects power to the unit.
This symbol indicates a protective conductor terminal.
Read all instructions pertaining to safety, set-up, and operation.
Proper operation is the user’s responsibility.
110-827 2
Safety Recommendations
To prevent injury to personnel and/or damage to property, always follow your workplace’s safety procedures when operating this equipment. You should also comply with the following safety recommendations:
WARNING: The Histology Bath uses isopentane as the bath fluid. Due to the flammability of this liquid, always use the Histology Bath under a fume hood.
WARNING:
Always connect the power cord on this Histology Bath to a grounded (3-prong) power outlet.
Make certain that the outlet is the same voltage and frequency as your unit.
Never operate the Histology Bath with a damaged power cord.
Always turn the Histology Bath Off and disconnect mains power before performing any
maintenance or service.
WARNING:
Never operate the Histology Bath without bath fluid in the reservoir. Periodically check the
reservoir to ensure that the liquid depth is within acceptable levels. Always refill the reservoir using the same bath fluid type that is already in the reservoir.
Use compatible bath fluids only.
Always drain all fluid from the reservoir before moving or lifting your Histology Bath. Be
sure to follow your organization’s procedures and practices regarding the safe lifting and relocation of heavy objects.
WARNING: Always allow the bath fluid to return to ambient temperature before draining.
WARNING: It is the user’s responsibility to properly decontaminate the unit in the event hazardous materials are spilled on exterior or interior surfaces. Consult manufacturer if there is any doubt regarding the compatibility of decontamination or cleaning agents.
Regulatory Compliance & Testing
CE
EC Low Voltage Directive 2006/95/EC
EC Electromagnetic Compatibility Directive 2004/108/EC
IEC 61010-1-2001
IEC 61010-2-2001
IEC 61326:2005 / EN 61326 : 2006
110-827 3