PolyScience Economy Water Baths Operating Manual

Operator’s Manual
Economy Water Baths
110-349
06.10.11
Table of Contents
Introduction .................................................................................................................................................2
General Safety Information .......................................................................................................................2
Safety Recommendations ......................................................................................................................... 3
Regulatory Compliance & Testing.............................................................................................................3
Unpacking Your Water Bath...................................................................................................................... 4
Contents .................................................................................................................................................... 4
Controls ..................................................................................................................................................... 4
Installation and Startup..............................................................................................................................5
General Site Requirements ....................................................................................................................... 5
Adding Liquid to the Reservoir .................................................................................................................. 5
Attaching the Reservoir Cover ..................................................................................................................6
Electrical Power.........................................................................................................................................6
Controller Setup......................................................................................................................................... 7
Safety Set Temperature......................................................................................................................... 7
Normal Operation........................................................................................................................................7
Turning Your Water Bath ON ....................................................................................................................7
Adjusting the Set Point Temperature ........................................................................................................7
Routine Maintenance & Troubleshooting.................................................................................................8
Cleaning the Bath ...................................................................................................................................... 8
Disassembling the Bath............................................................................................................................. 8
Replacing Fuses........................................................................................................................................8
Troubleshooting Chart...............................................................................................................................9
Technical Information...............................................................................................................................10
Performance Specifications..................................................................................................................... 10
Reservoir Fluids....................................................................................................................................... 11
Application Notes..................................................................................................................................... 12
Equipment Disposal (WEEE Directive)...................................................................................................12
Replacement Parts....................................................................................................................................13
Bath Fluids.................................................................................................................................................13
Service and Technical Support ...............................................................................................................14
Warranty.....................................................................................................................................................14
Introduction
Thank you for choosing this Water Bath. It is designed to handle a wide range of laboratory procedures, including: incubation, inactivation, and agglutination as well as most pharmaceutical, serological, biomedical, and industrial procedures.
To ensure optimum temperature uniformity, your Water Bath features an energy efficient, large-area heater and thermostatic control to provide temperature uniformity. A redundant safety thermostat is
standard on all models.
General Safety Information
When installed, operated, and maintained according to the directions in this manual and common safety procedures, your Water Bath should provide safe and reliable temperature control. Please ensure that all individuals involved in the installation, operation, or maintenance of this Water Bath read this manual thoroughly prior to working with the unit.
This symbol marks chapters and sections of this instruction manual that are particularly relevant to safety. When attached to the unit, this symbol draws attention to the relevant section of the instruction manual.
This symbol indicates that hazardous voltages may be present.
This symbol marks information that is particularly important.
This symbol indicates alternating current.
This symbol on the Power Switch / Circuit Breaker indicates that it places the unit into a fully
powered state.
This symbol on the Power Switch / Circuit Breaker indicates that it disconnects power to the unit.
This symbol on the Power Switch indicates that it places the unit in a standby mode. It DOES NOT
fully disconnect the unit from the power supply.
This symbol indicates a protective conductor terminal.
Read all instructions pertaining to safety, set-up, and operation.
Proper operation is the users’ responsibility.
Safety Recommendations
To prevent injury to personnel and/or damage to property, always follow your workplace’s safety procedures when operating this equipment. You should also comply with the following safety recommendations:
WARNING:
Always connect the power cord on this Water Bath to a grounded (3-prong) power outlet. Make
certain that the outlet is the same voltage and frequency as your unit.
Never operate the Water Bath with a damaged power cord.
Always turn the Water Bath OFF and disconnect mains power before performing any maintenance
or service.
WARNING:
Never operate the Water Bath without bath fluid in the reservoir. Periodically check the reservoir
to ensure that the liquid depth is within acceptable levels. Always refill the reservoir using the same bath fluid type that is already in the reservoir. Bath oil must not contain any water contaminants and should be preheated to the actual bath temperature before adding as there is an explosion hazard at high temperatures.
Use compatible bath fluids only.
Always drain all fluid from the reservoir before moving or lifting your Water Bath. Be sure to
follow your organization’s procedures and practices regarding the safe lifting and relocation of heavy objects.
WARNING: Always allow the bath fluid to cool to ambient temperature before draining.
WARNING: It is the user’s responsibility to properly decontaminate the unit in the event hazardous
materials are spilled on exterior or interior surfaces. Consult manufacturer if there is any doubt regarding the compatibility of decontamination or cleaning agents.
Regulatory Compliance & Testing
CSA (60 Hz units)
CAN/CSA C22.2 No. 0-M91 — General Requirement Canadian Electrical Code, Part II CAN/CSA C22.2 No. 1010.1-92 — Safety Requirements for Electrical Equipment for Measurement,
Control, and Laboratory Use; Part I: General Requirements UL Std. No. 61010A-1 — Electrical Equipment for Laboratory Use, Part I: General Requirements IEC 61010-1 — Safety Requirements for Electrical Equipment for Measurement, Control, and
Laboratory Use; Part I: General Requirements
CE (50 Hz units)
EC Low Voltage Directive 2006/95/EC EC Electromagnetic Compatibility Directive 2004/108/EC IEC 61010-1-2001 IEC 61010-2-2001 IEC 61326:2005 / EN 61326 : 2006
Unpacking Your Water Bath
r
Your water bath is shipped in a special carton. Retain the carton and all packing materials until the unit is completely assembled and working properly. Set up and run the unit immediately to confirm proper operation. Beyond one week, your unit may be warranty repaired, but not replaced. If the unit is damaged or does not operate properly, contact the transportation company, file a damage claim, then contact the company where your unit was purchased.
WARNING: Keep unit upright when moving. Be sure to follow your company’s procedures and
practices regarding the safe lifting and relocation of heavy objects.
Contents
The items included with your Water Bath are:
Water Bath
Gabled Reservoir Cover Assembly
Sample Tray
Operator’s Manual
Power Cord
Controls
Temperature Set Dial
Increases / decreases set point temperature.
Safety Thermostat
Used to adjust safety
set point temperature.
Over Temperature Safety Indicator
Lights when bath temperature exceeds safety set temperature.
Heat Indicato
Lit when heater is active.
Power Switch
Turns power to the Controller ON and OFF.